Based on the current situation of studying the thermodynamic property of Fe-C-Cr melt using the carbon saturated solubility, an experimental data treatment method of the carbon saturated solubility was put forward. Wi...Based on the current situation of studying the thermodynamic property of Fe-C-Cr melt using the carbon saturated solubility, an experimental data treatment method of the carbon saturated solubility was put forward. With this method a linear relationship ex- pression of the carbon saturated solubility in Fe-C-Cr melt was obtained, which intercept is dependent on temperature and independent of third component [Cr], but which slope is dependent on third component [Cr] and independent of temperature. Through this expression activity interaction coefficients at different temperatures were calculated and the relationship between activity interaction coefficients and temperature is also obtained.展开更多
Hepatocellular carcinoma(HCC)is a leading cause of morbidity and mortality worldwide,with rising clinical and economic burden as incidence increases.There are a multitude of evolving treatment options,including locore...Hepatocellular carcinoma(HCC)is a leading cause of morbidity and mortality worldwide,with rising clinical and economic burden as incidence increases.There are a multitude of evolving treatment options,including locoregional therapies which can be used alone,in combination with each other,or in combination with systemic therapy.These treatment options have shown to be effective in achieving remission,controlling tumor progression,improving disease free and overall survival in patients who cannot undergo resection and providing a bridge to transplant by debulking tumor burden to downstage patients.Following locoregional therapy(LRT),it is crucial to provide treatment response assessment to guide management and liver transplant candidacy.Therefore,Liver Imaging Reporting and Data Systems(LI-RADS)Treatment Response Algorithm(TRA)was created to provide a standardized assessment of HCC following LRT.LIRADS TRA provides a step by step approach to evaluate each lesion independently for accurate tumor assessment.In this review,we provide an overview of different locoregional therapies for HCC,describe the expected post treatment imaging appearance following treatment,and review the LI-RADS TRA with guidance for its application in clinical practice.Unique to other publications,we will also review emerging literature supporting the use of LI-RADS for assessment of HCC treatment response after LRT.展开更多
Computer simulation for materials processing needs a huge database containing a great deal of various physical properties of materials. In order to employ the accumulated large data on materials heat treatment in the ...Computer simulation for materials processing needs a huge database containing a great deal of various physical properties of materials. In order to employ the accumulated large data on materials heat treatment in the past years, it is significant to develop an intelligent database system. Based on the data mining technology for data analysis, an intelligent database web tool system of computer simulation for heat treatment process named as IndBASEweb-HT was built up. The architecture and the arithmetic of this system as well as its application were introduced.展开更多
Process data compression and trending are essential for improving control system performances. Swing Door Trending (SDT) algorithm is well designed to adapt the process trend while retaining the merit of simplicity. B...Process data compression and trending are essential for improving control system performances. Swing Door Trending (SDT) algorithm is well designed to adapt the process trend while retaining the merit of simplicity. But it cannot handle outliers and adapt to the fluctuations of actual data. An Improved SDT (ISDT) algorithm is proposed in this paper. The effectiveness and applicability of the ISDT algorithm are demonstrated by computations on both synthetic and real process data. By applying an adaptive recording limit as well as outliers-detecting rules, a higher compression ratio is achieved and outliers are identified and eliminated. The fidelity of the algorithm is also improved. It can be used both in online and batch mode, and integrated into existing software packages without change.展开更多
The development of simulation model and benchmark work have expanded in the past decade and many models and soft ware are introduced. The leading software "Hearts’ developed by Prof Inoue[1] and several other ha...The development of simulation model and benchmark work have expanded in the past decade and many models and soft ware are introduced. The leading software "Hearts’ developed by Prof Inoue[1] and several other have proved the effectiveness as the pre-production simulation work at many part of heat treatment processes[2-10]. Although, numerous other models and simulation studies dealt with many fundamental factors are reported at many conferences except very few models have not completed three dimensional computation methods, or lack of validation work to evaluate their tools exactly. In this paper, several distortion case studies will be introduced and the needs of fundamental study of distortion and internationally collaborative program on model evaluation and construction of materials database are proposed.展开更多
Recently published Medical Physics Practice Guideline 5.a. (MPPG 5.a.) by American Association of Physicists in Medicine (AAPM) sets the minimum requirements for treatment planning system (TPS) dose algorithm commissi...Recently published Medical Physics Practice Guideline 5.a. (MPPG 5.a.) by American Association of Physicists in Medicine (AAPM) sets the minimum requirements for treatment planning system (TPS) dose algorithm commissioning and quality assurance (QA). The guideline recommends some validation tests and tolerances based primarily on published AAPM task group reports and the criteria used by IROC Houston. We performed the commissioning and validation of the dose algorithms for both megavoltage photon and electron beams on three linacs following MPPG 5.a. We designed the validation experiments in an attempt to highlight the evaluation method and tolerance criteria recommended by the guideline. It seems that comparison of dose profiles using in-water scan is an effective technique for basic photon and electron validation. IMRT/VMAT dose calculation is recommended to be tested with some TG-119 and clinical cases, but no consensus of the tolerance exists. Extensive validation tests have provided the better understanding of the accuracy and limitation of a specific dose calculation algorithm. We believe that some tests and evaluation criteria given in the guideline can be further refined.展开更多
文摘Based on the current situation of studying the thermodynamic property of Fe-C-Cr melt using the carbon saturated solubility, an experimental data treatment method of the carbon saturated solubility was put forward. With this method a linear relationship ex- pression of the carbon saturated solubility in Fe-C-Cr melt was obtained, which intercept is dependent on temperature and independent of third component [Cr], but which slope is dependent on third component [Cr] and independent of temperature. Through this expression activity interaction coefficients at different temperatures were calculated and the relationship between activity interaction coefficients and temperature is also obtained.
文摘Hepatocellular carcinoma(HCC)is a leading cause of morbidity and mortality worldwide,with rising clinical and economic burden as incidence increases.There are a multitude of evolving treatment options,including locoregional therapies which can be used alone,in combination with each other,or in combination with systemic therapy.These treatment options have shown to be effective in achieving remission,controlling tumor progression,improving disease free and overall survival in patients who cannot undergo resection and providing a bridge to transplant by debulking tumor burden to downstage patients.Following locoregional therapy(LRT),it is crucial to provide treatment response assessment to guide management and liver transplant candidacy.Therefore,Liver Imaging Reporting and Data Systems(LI-RADS)Treatment Response Algorithm(TRA)was created to provide a standardized assessment of HCC following LRT.LIRADS TRA provides a step by step approach to evaluate each lesion independently for accurate tumor assessment.In this review,we provide an overview of different locoregional therapies for HCC,describe the expected post treatment imaging appearance following treatment,and review the LI-RADS TRA with guidance for its application in clinical practice.Unique to other publications,we will also review emerging literature supporting the use of LI-RADS for assessment of HCC treatment response after LRT.
文摘Computer simulation for materials processing needs a huge database containing a great deal of various physical properties of materials. In order to employ the accumulated large data on materials heat treatment in the past years, it is significant to develop an intelligent database system. Based on the data mining technology for data analysis, an intelligent database web tool system of computer simulation for heat treatment process named as IndBASEweb-HT was built up. The architecture and the arithmetic of this system as well as its application were introduced.
基金The authors would like to acknowledge the support from Project“973”of the State Key Fundamental Research under grant G1998030415.
文摘Process data compression and trending are essential for improving control system performances. Swing Door Trending (SDT) algorithm is well designed to adapt the process trend while retaining the merit of simplicity. But it cannot handle outliers and adapt to the fluctuations of actual data. An Improved SDT (ISDT) algorithm is proposed in this paper. The effectiveness and applicability of the ISDT algorithm are demonstrated by computations on both synthetic and real process data. By applying an adaptive recording limit as well as outliers-detecting rules, a higher compression ratio is achieved and outliers are identified and eliminated. The fidelity of the algorithm is also improved. It can be used both in online and batch mode, and integrated into existing software packages without change.
文摘The development of simulation model and benchmark work have expanded in the past decade and many models and soft ware are introduced. The leading software "Hearts’ developed by Prof Inoue[1] and several other have proved the effectiveness as the pre-production simulation work at many part of heat treatment processes[2-10]. Although, numerous other models and simulation studies dealt with many fundamental factors are reported at many conferences except very few models have not completed three dimensional computation methods, or lack of validation work to evaluate their tools exactly. In this paper, several distortion case studies will be introduced and the needs of fundamental study of distortion and internationally collaborative program on model evaluation and construction of materials database are proposed.
文摘Recently published Medical Physics Practice Guideline 5.a. (MPPG 5.a.) by American Association of Physicists in Medicine (AAPM) sets the minimum requirements for treatment planning system (TPS) dose algorithm commissioning and quality assurance (QA). The guideline recommends some validation tests and tolerances based primarily on published AAPM task group reports and the criteria used by IROC Houston. We performed the commissioning and validation of the dose algorithms for both megavoltage photon and electron beams on three linacs following MPPG 5.a. We designed the validation experiments in an attempt to highlight the evaluation method and tolerance criteria recommended by the guideline. It seems that comparison of dose profiles using in-water scan is an effective technique for basic photon and electron validation. IMRT/VMAT dose calculation is recommended to be tested with some TG-119 and clinical cases, but no consensus of the tolerance exists. Extensive validation tests have provided the better understanding of the accuracy and limitation of a specific dose calculation algorithm. We believe that some tests and evaluation criteria given in the guideline can be further refined.