Various studies have suggested several environmental,pharmacological,medical,and optical interventions and some are in use but their efficacy in myopia control may be transient,and the cellular,molecular,and biochemic...Various studies have suggested several environmental,pharmacological,medical,and optical interventions and some are in use but their efficacy in myopia control may be transient,and the cellular,molecular,and biochemical mechanisms involved unclear.Daylight exposure is currently regarded as an effective and enduring strategy in the control of myopia development and progression.However,the mechanism behind the effect of outdoor exposure and its association with genetic predisposition and other relatively more significant environmental factors on myopia is still a conundrum.This review focuses on survey-based and intervention-based studies carried out to propose a mechanism that accounts for myopia development and important for its control.展开更多
The following article has been retracted due to the fact that it cannot be accepted as Duplicate Publication. The Editorial Board takes a very strong respect to the author’s situation on this matter. This paper publi...The following article has been retracted due to the fact that it cannot be accepted as Duplicate Publication. The Editorial Board takes a very strong respect to the author’s situation on this matter. This paper published in Journal of Power and Energy Engineering Vol.3 No.4, April 2015, has been removed from this site.展开更多
Daylight is a fundamental element to obtain built environments that promote environmental comfort and energy efficiency. However, strategies that enhance the building daylight performance can affect its thermal energe...Daylight is a fundamental element to obtain built environments that promote environmental comfort and energy efficiency. However, strategies that enhance the building daylight performance can affect its thermal energetic performance. In this sense, research that addresses these aspects at the same time is considered essential. The objective of this paper was to evaluate the daylighting and thermal-energetic performance of administrative environments in a public institution, and to propose strategies that will enhance the use of daylight and lower energy consumption. Therefore, for future projects, and considering new buildings, and retrofit, this research will be an important reference. The research was developed through a case study of an administrative building model, in which the characteristics of solar orientation, light shelf use, glass type, and light and dark colors in walls were modified and combined, deriving it into models proposed. The daylighting performance evaluations were performed through dynamic simulation with the Rhinoceros for Diva software, and the thermal-energetic performance evaluations with the EnergyPlus software. The results of the work showed that a suitable solar orientation has a great impact on the automation of daylight and the energy consumption of the evaluated models, followed by the type of glass and the use of the light colors in internal walls, and that the use of artificial lighting with dimerization is fundamental as a complement to the daylight autonomy. For the boundary conditions of the study, the use of light shelves modified neither the daylight performance nor the thermal-energetic performance of the evaluated models.展开更多
Daylighting studies in buildings are key parts of environmental analysis and can be easily conducted at the early stages of design as part of environmentally responsive building design as well as to inform the final a...Daylighting studies in buildings are key parts of environmental analysis and can be easily conducted at the early stages of design as part of environmentally responsive building design as well as to inform the final architectural layout and interior design. The main aim of this study is to demonstrate how such daylighting studies can be completed at the early stages of design and, at the same time, to show the impact of window design and positioning on building indoor environments. The paper is focused on a study of window influence on room daylighting in residential buildings and computer lighting simulations in software packages: Windows Daylighting System and Autodesk Ecotect Analysis, have been carried out for different style and positioning of windows using several case studies. The main findings clearly indicated that not only the window size and style matters, but also the positioning of windows considering external walls which would make a significant influence on room daylighting levels and, therefore, such daylight studies are very important for the early stage of environmental analysis during building design.展开更多
Currently, daylighting ducts system is widely used as a daylighting device. Generally, daylighting duct system efficiently takes light from outside during the day, and conveys daylight to required location through lig...Currently, daylighting ducts system is widely used as a daylighting device. Generally, daylighting duct system efficiently takes light from outside during the day, and conveys daylight to required location through light duct manufactured by high reflectance mirror. Daylighting duct system can convey daylight to underground space that has no windows opening to external space. Daylighting system is composed of light collection part, light guide part and light emission part. Efficiency of daylighting system is depending on type of each part used in the system. However, it is very difficult to estimate exact light flow in the system considering type of the parts. Authors performed measurement experiments to make clear the light flow with real-size model and miniature model of daylighting duct system. We discussed effect of type of the parts on efficiency of daylighting duct system.展开更多
Improving daylighting strategy is a mandatory step to achieve visual enjoyment and energy saving in buildings. Psycho, physiological effects and energy performance have to be investigated in order to define a range of...Improving daylighting strategy is a mandatory step to achieve visual enjoyment and energy saving in buildings. Psycho, physiological effects and energy performance have to be investigated in order to define a range of different daylighting strategies, thanks to daylighting devices and climate based daylight modeling. Daylighting optimization ensures indoor healthier rooms, reduces electric light consumption and cuts the risk of glare. The best way to achieve these targets is to define users lighting needs, based on visual targets and to draw up some green measures to reduce electricity demands. Involving new climate-based daylight modeling metrics aims at defining proper illumination targets, in order to drastically reduce electrical lights, as well as reducing thermal loads deriving from cooling and HVAC (heating, ventilation and air conditioning) systems.展开更多
Different approaches have been introduced for the daylighting system to reduce energy consumption, but they were not populated due to complex, high cost, and insufficient designs. There has been a recent problem in ac...Different approaches have been introduced for the daylighting system to reduce energy consumption, but they were not populated due to complex, high cost, and insufficient designs. There has been a recent problem in achieving uniform distribution of sunlight at a destination deep inside the building. Therefore, we propose a system to achieve high illumination by illuminating the surface of the absorber (optical fibers) uniformly. To capture sunlight, parabolic reflector and Fresnel lens are used. Different reflectors and lenses are considered, compared, and investigated to direct uniform light, which solves the heat problem, into the optical fibers. In addition, this study includes comparison between fiber-based daylighting systems. The proposed system has been verified through simulation and experimental results.展开更多
In the subtropical zone of China, a large number of old factory buildings rich in industrial historical and cultural value have been transformed into art studios. In the existing research on building renovation, there...In the subtropical zone of China, a large number of old factory buildings rich in industrial historical and cultural value have been transformed into art studios. In the existing research on building renovation, there are still problems such as insufficient lighting, low uniformity, and ignoring the effect of glare in the lighting environment of buildings after transformation. To fill this research gap, this paper provides a daylighting design strategy for these factory buildings in subtropical zones to ensure that the transformed art studios can offer an excellent indoor daylighting environment. Through the control variable method, the window-to-wall ratio, the form of external windows, and the visible light transmittance of glass are set with quantitative and variable values, and a design strategy that meets the requirements of international general daylighting standards is obtained step by step through the simulation. The daylight factor, uniformity, daylight autonomy, and dynamic glare probability are used in this research process to measure whether the daylighting strategy meets the daylighting requirements of the CIBSE Lighting Guide for art studios. The results show that the average indoor lighting coefficient can be increased from 1.29 to 6.18, and the minimum value of the lighting coefficient can be increased from 0.4 to 4.4 by enlarging the windowed wall ratio from 1:30 to 1:3, using the combination method of the horizontal window, skylight and skylight recommended by the analysis results, and selecting veneer glass with 88% transmittance. This allows for better uniform lighting inside the building and reduces glare. This conclusion can support the lighting performance design of industrial buildings in the future.展开更多
The urgency of increasing energy efficiency in new building design and retrofits has pushed lighting simulation to play a central role in sustainable lighting design. The shape of the building and its orientation, the...The urgency of increasing energy efficiency in new building design and retrofits has pushed lighting simulation to play a central role in sustainable lighting design. The shape of the building and its orientation, the reflectances of building surfaces and glazed areas are important parameters in the daylighting design of buildings. Glazing systems can cut energy consumption and associated pollution sources, reduce peak demand, enhance daylighting performance and improve occupant comfort. This paper presents the results of a numerical and experimental comparison between the performances of an office building with and without external sunscreens. The aim was to analyse the illuminance distribution and some investigations have also been made with regards to the effect on daylight in rooms when sunscreens are used. The experimental results were obtained using an office building scale model and sky simulator. The numerical results were obtained through radiance, the ray-tracing program, to accurately predict the light levels and produce photo realistic images of the architectural space in all sky conditions: Illuminance values were obtained respectively through reference point measurements. The daylighting performances of the office building model with and without the sunscreens have been compared and analysed.展开更多
According to Chinese daylighting climate data,combined with the standard of Commission Inernationale de l'Eclairgae(CIE) general sky luminance distribution(SLD),the sky luminance distribution of typical daylightin...According to Chinese daylighting climate data,combined with the standard of Commission Inernationale de l'Eclairgae(CIE) general sky luminance distribution(SLD),the sky luminance distribution of typical daylighting climate zones in China was studied.Through the research on reference SLD of overcast,intermediate and clear types,the standards of clear and overcast SLD are consistent with CIE general sky,and the intermediate SLD has greater error with CIE general sky.The main types of Chinese sky luminance in different daylighting climate zones were obtained,which provide the basic data for simulation and forecast of China natural light,and provide reference for using the standard amendments of China future natural light.展开更多
In order to meet the requirements of indoor illumination, a LED daylight lamp model was designed, it can replace traditional fluorescent lamp without insteading additional power supply establishment. The optical prope...In order to meet the requirements of indoor illumination, a LED daylight lamp model was designed, it can replace traditional fluorescent lamp without insteading additional power supply establishment. The optical properties of the model were simulated using optical analysis software. Its luminous efficiency is about 30.4 lm/W, and the illuminance is about 38 lux when the distance is 1.5 m between the center of the model and measured spot. With the theoretically-optimized design of LED model, experiments based on the results of the optimal simulation in the laboratory were conducted to verify the performance of the proposed LED model, it reaches a power factor of about 0.8 at 6 W. The simulation results are very similar with the measured values. It is testified that simulative method is one of the effective tools for LED lighting optical design.展开更多
We investigated the link between ambulance transports and meteorological parameters of summer by using daily data in Osaka area, Japan. Daily observations for ambulance transports (from July 1 to September 30, 2009) w...We investigated the link between ambulance transports and meteorological parameters of summer by using daily data in Osaka area, Japan. Daily observations for ambulance transports (from July 1 to September 30, 2009) were obtained from Fire Department Service in Osaka. Data of meteorological parameters in Osaka area, Japan (from July 1 to September 30, 2009) were also obtained from Japan Meteorological Agency. Effect of meteorological parameters on ambulance transports was analyzed. A total of 49,526 ambulance transports were observed from July 1 to September 30, 2009 in Osaka, Japan. Ambulance transports were significantly correlated with mean air temperature (r = 0.298), the highest air temperature (r = 0.347), the lowest air temperature (r = 0.209) and daylight hours (r = 0.301). The higher air temperature was associated with higher ambulance transports of summer in Osaka area, Japan.展开更多
At the scheme design stage,the potential of daylighting is significant due to the saving for electric lighting use. There are few simple tools for architects to optimize the daylighting design. Therefore,it is useful ...At the scheme design stage,the potential of daylighting is significant due to the saving for electric lighting use. There are few simple tools for architects to optimize the daylighting design. Therefore,it is useful to develop a design guideline related to the evaluation of lighting energy saving potential and sunlight design strategies. This paper analyzes the impacts of different artificial lighting control methods and design parameters on daylighting. A direct correlation between lighting energy consumption and parameters such as orientations,window to wall ratio (WWR) and perimeter depth is established. A simplified prediction model is proposed to estimate lighting energy consumption with the given perimeter depth,WWR,and window transparency. Validation of the model is carried out compared with detailed lighting simulation software for an office building. After the variation analysis for these parameters,design advises for the daylighting design at scheme design phase are summarized.展开更多
This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typ...This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.展开更多
As part of a collaborative project,we took the window shutter—a widely used traditional facade element—and reinterpreted it for“adaptive”solutions using new,sustainable technologies.The aim was to design a modular...As part of a collaborative project,we took the window shutter—a widely used traditional facade element—and reinterpreted it for“adaptive”solutions using new,sustainable technologies.The aim was to design a modular construction kit that varies radiant energy,light and air flow to weather conditions and occupant requirements in new and existing residential and office buildings.展开更多
文摘Various studies have suggested several environmental,pharmacological,medical,and optical interventions and some are in use but their efficacy in myopia control may be transient,and the cellular,molecular,and biochemical mechanisms involved unclear.Daylight exposure is currently regarded as an effective and enduring strategy in the control of myopia development and progression.However,the mechanism behind the effect of outdoor exposure and its association with genetic predisposition and other relatively more significant environmental factors on myopia is still a conundrum.This review focuses on survey-based and intervention-based studies carried out to propose a mechanism that accounts for myopia development and important for its control.
文摘The following article has been retracted due to the fact that it cannot be accepted as Duplicate Publication. The Editorial Board takes a very strong respect to the author’s situation on this matter. This paper published in Journal of Power and Energy Engineering Vol.3 No.4, April 2015, has been removed from this site.
文摘Daylight is a fundamental element to obtain built environments that promote environmental comfort and energy efficiency. However, strategies that enhance the building daylight performance can affect its thermal energetic performance. In this sense, research that addresses these aspects at the same time is considered essential. The objective of this paper was to evaluate the daylighting and thermal-energetic performance of administrative environments in a public institution, and to propose strategies that will enhance the use of daylight and lower energy consumption. Therefore, for future projects, and considering new buildings, and retrofit, this research will be an important reference. The research was developed through a case study of an administrative building model, in which the characteristics of solar orientation, light shelf use, glass type, and light and dark colors in walls were modified and combined, deriving it into models proposed. The daylighting performance evaluations were performed through dynamic simulation with the Rhinoceros for Diva software, and the thermal-energetic performance evaluations with the EnergyPlus software. The results of the work showed that a suitable solar orientation has a great impact on the automation of daylight and the energy consumption of the evaluated models, followed by the type of glass and the use of the light colors in internal walls, and that the use of artificial lighting with dimerization is fundamental as a complement to the daylight autonomy. For the boundary conditions of the study, the use of light shelves modified neither the daylight performance nor the thermal-energetic performance of the evaluated models.
文摘Daylighting studies in buildings are key parts of environmental analysis and can be easily conducted at the early stages of design as part of environmentally responsive building design as well as to inform the final architectural layout and interior design. The main aim of this study is to demonstrate how such daylighting studies can be completed at the early stages of design and, at the same time, to show the impact of window design and positioning on building indoor environments. The paper is focused on a study of window influence on room daylighting in residential buildings and computer lighting simulations in software packages: Windows Daylighting System and Autodesk Ecotect Analysis, have been carried out for different style and positioning of windows using several case studies. The main findings clearly indicated that not only the window size and style matters, but also the positioning of windows considering external walls which would make a significant influence on room daylighting levels and, therefore, such daylight studies are very important for the early stage of environmental analysis during building design.
文摘Currently, daylighting ducts system is widely used as a daylighting device. Generally, daylighting duct system efficiently takes light from outside during the day, and conveys daylight to required location through light duct manufactured by high reflectance mirror. Daylighting duct system can convey daylight to underground space that has no windows opening to external space. Daylighting system is composed of light collection part, light guide part and light emission part. Efficiency of daylighting system is depending on type of each part used in the system. However, it is very difficult to estimate exact light flow in the system considering type of the parts. Authors performed measurement experiments to make clear the light flow with real-size model and miniature model of daylighting duct system. We discussed effect of type of the parts on efficiency of daylighting duct system.
文摘Improving daylighting strategy is a mandatory step to achieve visual enjoyment and energy saving in buildings. Psycho, physiological effects and energy performance have to be investigated in order to define a range of different daylighting strategies, thanks to daylighting devices and climate based daylight modeling. Daylighting optimization ensures indoor healthier rooms, reduces electric light consumption and cuts the risk of glare. The best way to achieve these targets is to define users lighting needs, based on visual targets and to draw up some green measures to reduce electricity demands. Involving new climate-based daylight modeling metrics aims at defining proper illumination targets, in order to drastically reduce electrical lights, as well as reducing thermal loads deriving from cooling and HVAC (heating, ventilation and air conditioning) systems.
文摘Different approaches have been introduced for the daylighting system to reduce energy consumption, but they were not populated due to complex, high cost, and insufficient designs. There has been a recent problem in achieving uniform distribution of sunlight at a destination deep inside the building. Therefore, we propose a system to achieve high illumination by illuminating the surface of the absorber (optical fibers) uniformly. To capture sunlight, parabolic reflector and Fresnel lens are used. Different reflectors and lenses are considered, compared, and investigated to direct uniform light, which solves the heat problem, into the optical fibers. In addition, this study includes comparison between fiber-based daylighting systems. The proposed system has been verified through simulation and experimental results.
文摘In the subtropical zone of China, a large number of old factory buildings rich in industrial historical and cultural value have been transformed into art studios. In the existing research on building renovation, there are still problems such as insufficient lighting, low uniformity, and ignoring the effect of glare in the lighting environment of buildings after transformation. To fill this research gap, this paper provides a daylighting design strategy for these factory buildings in subtropical zones to ensure that the transformed art studios can offer an excellent indoor daylighting environment. Through the control variable method, the window-to-wall ratio, the form of external windows, and the visible light transmittance of glass are set with quantitative and variable values, and a design strategy that meets the requirements of international general daylighting standards is obtained step by step through the simulation. The daylight factor, uniformity, daylight autonomy, and dynamic glare probability are used in this research process to measure whether the daylighting strategy meets the daylighting requirements of the CIBSE Lighting Guide for art studios. The results show that the average indoor lighting coefficient can be increased from 1.29 to 6.18, and the minimum value of the lighting coefficient can be increased from 0.4 to 4.4 by enlarging the windowed wall ratio from 1:30 to 1:3, using the combination method of the horizontal window, skylight and skylight recommended by the analysis results, and selecting veneer glass with 88% transmittance. This allows for better uniform lighting inside the building and reduces glare. This conclusion can support the lighting performance design of industrial buildings in the future.
文摘The urgency of increasing energy efficiency in new building design and retrofits has pushed lighting simulation to play a central role in sustainable lighting design. The shape of the building and its orientation, the reflectances of building surfaces and glazed areas are important parameters in the daylighting design of buildings. Glazing systems can cut energy consumption and associated pollution sources, reduce peak demand, enhance daylighting performance and improve occupant comfort. This paper presents the results of a numerical and experimental comparison between the performances of an office building with and without external sunscreens. The aim was to analyse the illuminance distribution and some investigations have also been made with regards to the effect on daylight in rooms when sunscreens are used. The experimental results were obtained using an office building scale model and sky simulator. The numerical results were obtained through radiance, the ray-tracing program, to accurately predict the light levels and produce photo realistic images of the architectural space in all sky conditions: Illuminance values were obtained respectively through reference point measurements. The daylighting performances of the office building model with and without the sunscreens have been compared and analysed.
基金Project(50908239) supported by National Natural Science Foundation of China Project(2010KB14) supported by State Key Laboratory of Subtropical Building Science of South China University of Technology, China Project(CDJZR10190006) supported by the Fundamental Research Funds for the Central Universities, China
文摘According to Chinese daylighting climate data,combined with the standard of Commission Inernationale de l'Eclairgae(CIE) general sky luminance distribution(SLD),the sky luminance distribution of typical daylighting climate zones in China was studied.Through the research on reference SLD of overcast,intermediate and clear types,the standards of clear and overcast SLD are consistent with CIE general sky,and the intermediate SLD has greater error with CIE general sky.The main types of Chinese sky luminance in different daylighting climate zones were obtained,which provide the basic data for simulation and forecast of China natural light,and provide reference for using the standard amendments of China future natural light.
基金Key Scientific and Technological Research Projects of Henan Province(072102240027) Doctor Foundationof Henan Polytechnic University(648602)Postgraduate Degree Thesis Innovation Foundation of Henan Polytechnic University(644005)
文摘In order to meet the requirements of indoor illumination, a LED daylight lamp model was designed, it can replace traditional fluorescent lamp without insteading additional power supply establishment. The optical properties of the model were simulated using optical analysis software. Its luminous efficiency is about 30.4 lm/W, and the illuminance is about 38 lux when the distance is 1.5 m between the center of the model and measured spot. With the theoretically-optimized design of LED model, experiments based on the results of the optimal simulation in the laboratory were conducted to verify the performance of the proposed LED model, it reaches a power factor of about 0.8 at 6 W. The simulation results are very similar with the measured values. It is testified that simulative method is one of the effective tools for LED lighting optical design.
文摘We investigated the link between ambulance transports and meteorological parameters of summer by using daily data in Osaka area, Japan. Daily observations for ambulance transports (from July 1 to September 30, 2009) were obtained from Fire Department Service in Osaka. Data of meteorological parameters in Osaka area, Japan (from July 1 to September 30, 2009) were also obtained from Japan Meteorological Agency. Effect of meteorological parameters on ambulance transports was analyzed. A total of 49,526 ambulance transports were observed from July 1 to September 30, 2009 in Osaka, Japan. Ambulance transports were significantly correlated with mean air temperature (r = 0.298), the highest air temperature (r = 0.347), the lowest air temperature (r = 0.209) and daylight hours (r = 0.301). The higher air temperature was associated with higher ambulance transports of summer in Osaka area, Japan.
基金Project(2006BAJ02A02) supported by the National Key Technologies R & D Program of China
文摘At the scheme design stage,the potential of daylighting is significant due to the saving for electric lighting use. There are few simple tools for architects to optimize the daylighting design. Therefore,it is useful to develop a design guideline related to the evaluation of lighting energy saving potential and sunlight design strategies. This paper analyzes the impacts of different artificial lighting control methods and design parameters on daylighting. A direct correlation between lighting energy consumption and parameters such as orientations,window to wall ratio (WWR) and perimeter depth is established. A simplified prediction model is proposed to estimate lighting energy consumption with the given perimeter depth,WWR,and window transparency. Validation of the model is carried out compared with detailed lighting simulation software for an office building. After the variation analysis for these parameters,design advises for the daylighting design at scheme design phase are summarized.
基金Sponsored by the National Project of Scientific and Technical Supporting Programs Funded by Ministry of Science & Technology of China (Grant No.2012BAJ06B04-02)
文摘This paper presents a comprehensive survey for the situation of light environment in large commercial building through architecture design information,subjective and objective fieldwork and online survey for three typical commercial building forms( centralized form, covered mall shopping center, lifestyle center).Descriptive method is used for statistical analysis which includes the evaluation of light environmental quality,subjective assessment among daylight and artificial illumination,effect of physical characteristics on subjective assessment of light environment. Based on the results of statistical analysis,the improving strategies for light environment are proposed in terms of making use of daylight,artificial lighting design and improvement of the overall light environmental quality. The design strategies which based on the consumer needs is very important can provide help for further impact prediction on the quality of light environment.
文摘As part of a collaborative project,we took the window shutter—a widely used traditional facade element—and reinterpreted it for“adaptive”solutions using new,sustainable technologies.The aim was to design a modular construction kit that varies radiant energy,light and air flow to weather conditions and occupant requirements in new and existing residential and office buildings.