Due to several factors, wind energy becomes an essential type of electricity generation. The share of this type of energy in the network is becoming increasingly important. The objective of this work is to present the...Due to several factors, wind energy becomes an essential type of electricity generation. The share of this type of energy in the network is becoming increasingly important. The objective of this work is to present the modeling and control strategy of a grid connected wind power generation scheme using a doubly fed induction generator (DFIG) driven by the rotor. This paper is to present the complete modeling and simulation of a wind turbine driven DFIG in the second mode of operating (the wind turbine pitch control is deactivated). It will introduce the vector control, which makes it possible to control independently the active and reactive power exchanged between the stator of the generator and the grid, based on vector control concept (with stator flux or voltage orientation) with classical PI controllers. Various simula- tion tests are conducted to observe the system behavior and evaluate the performance of the control for some optimization criteria (energy efficiency and the robustness of the control). It is also interesting to play on the quality of electric power by controlling the reactive power exchanged with the grid, which will facilitate making a local correction of power factor.展开更多
Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to ac...Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to achieve high-performance decoupled control of the active and reactive powers injected to the grid from distributed energy resources (DER).The FCS-MPC scheme instantaneously searches for and applies the optimum inverter switching state that can achieve certain goals, such as minimum deviation between reference and actual power;so that both power components (P and Q) are well controlled to their reference values.In addition, an effective method to attenuate undesired cross coupling between the P and Q control loops, which occurs only during transient operation, is investigated. The proposed method is based on the variation of the weight factors of the terms of the FCS-MPC cost function, so a higher weight factor is assigned to the cost function term that is exposed to greater disturbance. Empirical formulae of optimum weight factors as functions of the reference active and reactive power signals are proposed and mathematically derived. The investigated FCS-MPC control scheme is incorporated with the LVRT function to support the grid voltage in fulfilling and accomplishing the up-to-date grid codes. The LVRT algorithm is based on a modification of the references of active and reactive powers as functions of the instantaneous grid voltage such that suitable values of P and Q are injected to the grid during voltage sag.The performance of the elaborated FCS-MPC PQ scheme is studied under various operating scenarios, including steady-state and transient conditions. Results demonstrate the validity and effectiveness of the proposed scheme with regard to the achievement of high-performance operation and quick response of grid-tied inverters during normal and fault modes.展开更多
This paper analyzes the physical meaning of the active and reactive power flow in the finite L-shaped beams and studies the active vibration control of the structures based on the active and reactive power flow.The tr...This paper analyzes the physical meaning of the active and reactive power flow in the finite L-shaped beams and studies the active vibration control of the structures based on the active and reactive power flow.The traveling wave approach is used to calculate the structural dynamic responses.Because the error of control force is inevitable in practical applications,the effects of the error of control force on the control results are studied.The study indicates that the error of control force has pronounced influence on the control results of the acceleration and reactive power flow.It is obvious that the reactive power flow can represent the vibration strength component of the complex intensity,and the active power flow strongly depends on the structural damping of the finite beams.展开更多
Load flow is an important tool used by power engineers for planning, to determine the best operation for a power system and exchange of power between utility companies. In order to have an efficient operating power sy...Load flow is an important tool used by power engineers for planning, to determine the best operation for a power system and exchange of power between utility companies. In order to have an efficient operating power system, it is necessary to determine which method is suitable and efficient for the system’s load flow analysis. A power flow analysis method may take a long time and therefore prevent achieving an accurate result to a power flow solution because of continuous changes in power demand and generations. This paper presents analysis of the load flow problem in power system planning studies. The numerical methods: Gauss-Seidel, Newton-Raphson and Fast Decoupled methods were compared for a power flow analysis solution. Simulation is carried out using Matlab for test cases of IEEE 9-Bus, IEEE 30-Bus and IEEE 57-Bus system. The simulation results were compared for number of iteration, computational time, tolerance value and convergence. The compared results show that Newton-Raphson is the most reliable method because it has the least number of iteration and converges faster.展开更多
A distributed active and reactive power control(DARPC)strategy based on the alternating direction method of multipliers(ADMM)is proposed for regional AC transmission system(TS)with wind farms(WFs).The proposed DARPC s...A distributed active and reactive power control(DARPC)strategy based on the alternating direction method of multipliers(ADMM)is proposed for regional AC transmission system(TS)with wind farms(WFs).The proposed DARPC strategy optimizes the power distribution among the WFs to minimize the power losses of the AC TS while tracking the active power reference from the transmission system operator(TSO),and minimizes the voltage deviation of the buses inside the WF from the rated voltage as well as the power losses of the WF collection system.The optimal power flow(OPF)of the TS is relaxed by using the semidefinite programming(SDP)relaxation while the branch flow model is used to model the WF collection system.In the DARPC strategy,the large-scale strongly-coupled optimization problem is decomposed by using the ADMM,which is solved in the regional TS controller and WF controllers in parallel without loss of the global optimality.The boundary information is exchanged between the regional TS controller and WF controllers.Compared with the conventional OPF method of the TS with WFs,the optimality and accuracy of the system operation can be improved.Moreover,the proposed strategy efficiently reduces the computation burden of the TS controller and eliminates the need of a central controller.The protection of the information privacy can be enhanced.A modified IEEE 9-bus system with two WFs consisting of 64 wind turbines(WTs)is used to validate the proposed DARPC strategy.展开更多
在级联H桥多电平静止无功发生器(Static Var Generator,SVG)中,H桥固有的结构特性使得角形级联SVG直流侧电容电压存在二倍频纹波,电压波动影响电能质量补偿效果甚至导致系统失调。为抑制角形级联SVG的H桥直流侧二倍频电压纹波,文中提出...在级联H桥多电平静止无功发生器(Static Var Generator,SVG)中,H桥固有的结构特性使得角形级联SVG直流侧电容电压存在二倍频纹波,电压波动影响电能质量补偿效果甚至导致系统失调。为抑制角形级联SVG的H桥直流侧二倍频电压纹波,文中提出了基于Boost型有源功率解耦(Active Power Decoupling,APD)的角形级联H桥多电平SVG的设计方案。有源功率解耦电路将波动功率和稳定功率相互分离,采用储能元件吸收波动功率,从而削弱了H桥直流侧电压波动。利用MATLAB/Simulink搭建仿真平台进行仿真,结果表明基于Boost型有源功率解耦的角形级联H桥多电平SVG能够有效抑制直流侧电容电压的二倍频纹波。展开更多
文摘Due to several factors, wind energy becomes an essential type of electricity generation. The share of this type of energy in the network is becoming increasingly important. The objective of this work is to present the modeling and control strategy of a grid connected wind power generation scheme using a doubly fed induction generator (DFIG) driven by the rotor. This paper is to present the complete modeling and simulation of a wind turbine driven DFIG in the second mode of operating (the wind turbine pitch control is deactivated). It will introduce the vector control, which makes it possible to control independently the active and reactive power exchanged between the stator of the generator and the grid, based on vector control concept (with stator flux or voltage orientation) with classical PI controllers. Various simula- tion tests are conducted to observe the system behavior and evaluate the performance of the control for some optimization criteria (energy efficiency and the robustness of the control). It is also interesting to play on the quality of electric power by controlling the reactive power exchanged with the grid, which will facilitate making a local correction of power factor.
文摘Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to achieve high-performance decoupled control of the active and reactive powers injected to the grid from distributed energy resources (DER).The FCS-MPC scheme instantaneously searches for and applies the optimum inverter switching state that can achieve certain goals, such as minimum deviation between reference and actual power;so that both power components (P and Q) are well controlled to their reference values.In addition, an effective method to attenuate undesired cross coupling between the P and Q control loops, which occurs only during transient operation, is investigated. The proposed method is based on the variation of the weight factors of the terms of the FCS-MPC cost function, so a higher weight factor is assigned to the cost function term that is exposed to greater disturbance. Empirical formulae of optimum weight factors as functions of the reference active and reactive power signals are proposed and mathematically derived. The investigated FCS-MPC control scheme is incorporated with the LVRT function to support the grid voltage in fulfilling and accomplishing the up-to-date grid codes. The LVRT algorithm is based on a modification of the references of active and reactive powers as functions of the instantaneous grid voltage such that suitable values of P and Q are injected to the grid during voltage sag.The performance of the elaborated FCS-MPC PQ scheme is studied under various operating scenarios, including steady-state and transient conditions. Results demonstrate the validity and effectiveness of the proposed scheme with regard to the achievement of high-performance operation and quick response of grid-tied inverters during normal and fault modes.
基金supported by the National Natural Science Foundation of China (Grant Nos.10672017, 10632020 and 11002045)
文摘This paper analyzes the physical meaning of the active and reactive power flow in the finite L-shaped beams and studies the active vibration control of the structures based on the active and reactive power flow.The traveling wave approach is used to calculate the structural dynamic responses.Because the error of control force is inevitable in practical applications,the effects of the error of control force on the control results are studied.The study indicates that the error of control force has pronounced influence on the control results of the acceleration and reactive power flow.It is obvious that the reactive power flow can represent the vibration strength component of the complex intensity,and the active power flow strongly depends on the structural damping of the finite beams.
文摘Load flow is an important tool used by power engineers for planning, to determine the best operation for a power system and exchange of power between utility companies. In order to have an efficient operating power system, it is necessary to determine which method is suitable and efficient for the system’s load flow analysis. A power flow analysis method may take a long time and therefore prevent achieving an accurate result to a power flow solution because of continuous changes in power demand and generations. This paper presents analysis of the load flow problem in power system planning studies. The numerical methods: Gauss-Seidel, Newton-Raphson and Fast Decoupled methods were compared for a power flow analysis solution. Simulation is carried out using Matlab for test cases of IEEE 9-Bus, IEEE 30-Bus and IEEE 57-Bus system. The simulation results were compared for number of iteration, computational time, tolerance value and convergence. The compared results show that Newton-Raphson is the most reliable method because it has the least number of iteration and converges faster.
基金supported in part by Technical University of Denmark(DTU)in part by China Scholarship Council(No.201806130202)。
文摘A distributed active and reactive power control(DARPC)strategy based on the alternating direction method of multipliers(ADMM)is proposed for regional AC transmission system(TS)with wind farms(WFs).The proposed DARPC strategy optimizes the power distribution among the WFs to minimize the power losses of the AC TS while tracking the active power reference from the transmission system operator(TSO),and minimizes the voltage deviation of the buses inside the WF from the rated voltage as well as the power losses of the WF collection system.The optimal power flow(OPF)of the TS is relaxed by using the semidefinite programming(SDP)relaxation while the branch flow model is used to model the WF collection system.In the DARPC strategy,the large-scale strongly-coupled optimization problem is decomposed by using the ADMM,which is solved in the regional TS controller and WF controllers in parallel without loss of the global optimality.The boundary information is exchanged between the regional TS controller and WF controllers.Compared with the conventional OPF method of the TS with WFs,the optimality and accuracy of the system operation can be improved.Moreover,the proposed strategy efficiently reduces the computation burden of the TS controller and eliminates the need of a central controller.The protection of the information privacy can be enhanced.A modified IEEE 9-bus system with two WFs consisting of 64 wind turbines(WTs)is used to validate the proposed DARPC strategy.
文摘在级联H桥多电平静止无功发生器(Static Var Generator,SVG)中,H桥固有的结构特性使得角形级联SVG直流侧电容电压存在二倍频纹波,电压波动影响电能质量补偿效果甚至导致系统失调。为抑制角形级联SVG的H桥直流侧二倍频电压纹波,文中提出了基于Boost型有源功率解耦(Active Power Decoupling,APD)的角形级联H桥多电平SVG的设计方案。有源功率解耦电路将波动功率和稳定功率相互分离,采用储能元件吸收波动功率,从而削弱了H桥直流侧电压波动。利用MATLAB/Simulink搭建仿真平台进行仿真,结果表明基于Boost型有源功率解耦的角形级联H桥多电平SVG能够有效抑制直流侧电容电压的二倍频纹波。