期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Deep oxidation in propane oxidative dehydrogenation to propene over V_2O_5/γ-Al_2O_3 studied by in-situ DRIFTS
1
作者 Yunbing He Hongbing Ji Jianhua Xu Lefu Wang 《Journal of Natural Gas Chemistry》 EI CAS CSCD 2009年第3期359-364,共6页
In-situ DRIFTS was used to study the deep oxidation of propane, a side reaction during propane oxidative dehydrogenation to propene. Strong adsorption of propene was supposed to be the main reason for the deep oxidati... In-situ DRIFTS was used to study the deep oxidation of propane, a side reaction during propane oxidative dehydrogenation to propene. Strong adsorption of propene was supposed to be the main reason for the deep oxidation. It was found that gaseous oxygen in the feed and the reaction temperature had great influence on the reaction. To obtain a relative high selectivity to propene, the reaction temperature should be maintained at 150-250℃ with a proper content of gaseous oxygen in the feed for a certain catalyst and some modifiers which could weaken the adsorption of propene on the catalyst surface would be favorable. 展开更多
关键词 PROPANE PROPENE oxidative dehydrogenation in-situ DRIFTS deep oxidation
下载PDF
Laser-Induced Single Event Transients in Local Oxidation of Silicon and Deep Trench Isolation Silicon-Germanium Heterojunction Bipolar Transistors 被引量:2
2
作者 李培 郭红霞 +2 位作者 郭旗 张晋新 魏莹 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第8期204-207,共4页
We present a study on the single event transient (SET) induced by a pulsed laser in different silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs) with the structure of local oxidation of silicon ... We present a study on the single event transient (SET) induced by a pulsed laser in different silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs) with the structure of local oxidation of silicon (LOCOS) and deep trench isolation (DTI). The experimental results are discussed in detail and it is demonstrated that a SiGe HBT with the structure of LOCOS is more sensitive than the DTI SiGe HBT in the SET. Because of the limitation of the DTI structure, the charge collection of diffusion in the DTI SiGe HBT is less than that of the LOCOS SiGe HBT. The SET sensitive area of the LOCOS SiGe HBT is located in the eollector-substrate (C/S) junction, while the sensitive area of the DTI SiGe HBT is located near to the collector electrodes. 展开更多
关键词 LOCOS DTI HBT Laser-Induced Single Event Transients in Local oxidation of Silicon and deep Trench Isolation Silicon-Germanium Heterojunction Bipolar Transistors
下载PDF
Analysis of anticancer compound,indole-3-carbinol,in broccoli using a new ultrasound-assisted dispersive-filter extraction method based on poly(deep eutectic solvent)-graphene oxide nanocomposite
3
作者 Yanan Yuan Huanhuan Chen +2 位作者 Yehong Han Fengxia Qiao Hongyuan Yan 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第2期301-307,共7页
Indole-3-carbinol(I3C),an important anticancer compound found in broccoli,has attracted considerable attention.The rapid extraction and accurate analysis of I3C in the pharmaceutical industry in broccoli is challengin... Indole-3-carbinol(I3C),an important anticancer compound found in broccoli,has attracted considerable attention.The rapid extraction and accurate analysis of I3C in the pharmaceutical industry in broccoli is challenging as I3C is unstable at low pH and high temperature.In this study,a rapid,accurate,and lowcost ultrasound-assisted dispersive-filter extraction(UADFE)technique based on poly(deep eutectic solvent)-graphene oxide(PDES-GO)adsorbent was developed for the isolation and analysis of I3C in broccoli for the first time.PDES-GO with multiple adsorption interactions and a fast mass transfer rate was synthesized to accelerate adsorption and desorption.UADFE was developed by combining dispersive solid-phase extraction(DSPE)and filter solid-phase extraction(FSPE)to realize rapid extraction and separation.Based on the above two strategies,the proposed PDES-GO-UADFE method coupled with high-performance liquid chromatography(HPLC)allowed the rapid(15-16 min),accurate(84.3%-96.4%),and low-cost(adsorbent:3.00 mg)analysis of I3C in broccoli and was superior to solid-phase extraction,DSPE,and FSPE methods.The proposed method showed remarkable linearity(r=0.9998;range:0.0840-48.0 mg/g),low limit of quantification(0.0840 mg/g),and high precision(relative standard deviation<5.6%).Therefore,the PDES-GO-UADFE-HPLC method shows significant potential in the field of pharmaceutical analysis for the separation and analysis of anti-cancer compounds in complex plant samples. 展开更多
关键词 INDOLE-3-CARBINOL BROCCOLI Poly(deep eutectic solvent)-graphene oxide Ultrasound-assisted dispersive-filter extraction Rapid analysis
下载PDF