A technology of ultrasonic-electric united desalting and dewatering of crude oil is studied. The ultrasonic setup is designed to form a standing-wave field, which is more efficient for agglomeration of water particles...A technology of ultrasonic-electric united desalting and dewatering of crude oil is studied. The ultrasonic setup is designed to form a standing-wave field, which is more efficient for agglomeration of water particles. The desalting and dewatering results of the ultrasonic-electric united process are compared with those of the electric process. For high salt-contenting crude oil (40-70 mg·L ^-1), the salt content is still above 10.0 mg·L^-1 after crude oil has been treated by two-stage electric desalting process in refinery, which cannot meet the need of refinery. Ultrasonic-electric united process is a novel technology for treating the high salt-contenting oil. On the optimal operating conditions of the ultrasonic-electric united process, the salt content of crude oil can be reduced from 67 5 mg·L^-1 to 3.97 mg·L ^-1 by one-stage ultrasonic-electric united process, and the water content falls below 0.3% (by volume). The results show that the ultrasonic-electric united process is more effective than the electric process in high salt-contenting oil desalting. This technology should be useful in the refinery process.展开更多
Online measurement of water volume fraction (WVF) in dehydrated crude oil is a difficult task due to very little water in dehydrated crude oil and high precision requirements. We presents a method to measure water vol...Online measurement of water volume fraction (WVF) in dehydrated crude oil is a difficult task due to very little water in dehydrated crude oil and high precision requirements. We presents a method to measure water volume fraction in dehydrated crude oil with γ-ray densitometry. The Monte Carlo computer simulation packet GEANT4 was used to analyze the WVF measuring sensitivity of the γ-ray densitometry at different γ-ray energies, and effects of temperature, pressure, salinity and oil components on WVF measurement. The results show that the γ-ray densitometry has high sensitivity in γ-ray energy ranges of 16~25keV, and it can distinguish WVF changes of 0.0005. The calculated WVF decreases about 0.0002 with 1℃ of temperature increase and they have approximately linear relation with temperature when water volume fraction remains the same. Effects of pressure, salinity and oil components on water volume fraction can be neglected. Experiments were done to analyze sensitivity of the γ-ray densitometry. The results , as compared with simulations, demonstrate that simulation method is reliable and it is feasible to gauge low water volume fraction using low energy γ-rays.展开更多
Removal of water contained in extra-viscous crude oil is quite difficult because of the high viscosity and high resins content of heavy oil.The microwave technology was introduced for the separation of water from high...Removal of water contained in extra-viscous crude oil is quite difficult because of the high viscosity and high resins content of heavy oil.The microwave technology was introduced for the separation of water from high-viscosity crude oil in the presence of sodium acetate.The decrease in zeta-potential of interface and the viscosity of crude oil are responsible for the accelerated separation of water under microwave irradiation.The influences of the concentration of sodium acetate in sample,irradiation pressure,irradiation time and irradiation power on the separation efficiency were investigated.The optimum technological condition for the refining process was determined.Upon treating the sample 1 (with a water concentration of 50%),the water removal rate was 98.44%,when the optimum conditions were identified to be a sodium acetate concentration of 2%,an irradiation pressure of 0.1 MPa,an irradiation time of 2 min,and an irradiation power of 225 W,with the recovery of sodium acetate reaching 97.88%.Upon treating the sample 2 (the concentration of water was 20%),the water removal rate was 93.85%,when the optimum conditions were determined to be a sodium acetate concentration of 3%,an irradiation pressure of 0.1 MPa,an irradiation time of 4 min,and an irradiation power of 375 W,with the recovery of sodium acetate reaching 93.54%.By using this method,the dehydration efficiency was increased rapidly.展开更多
文摘A technology of ultrasonic-electric united desalting and dewatering of crude oil is studied. The ultrasonic setup is designed to form a standing-wave field, which is more efficient for agglomeration of water particles. The desalting and dewatering results of the ultrasonic-electric united process are compared with those of the electric process. For high salt-contenting crude oil (40-70 mg·L ^-1), the salt content is still above 10.0 mg·L^-1 after crude oil has been treated by two-stage electric desalting process in refinery, which cannot meet the need of refinery. Ultrasonic-electric united process is a novel technology for treating the high salt-contenting oil. On the optimal operating conditions of the ultrasonic-electric united process, the salt content of crude oil can be reduced from 67 5 mg·L^-1 to 3.97 mg·L ^-1 by one-stage ultrasonic-electric united process, and the water content falls below 0.3% (by volume). The results show that the ultrasonic-electric united process is more effective than the electric process in high salt-contenting oil desalting. This technology should be useful in the refinery process.
文摘Online measurement of water volume fraction (WVF) in dehydrated crude oil is a difficult task due to very little water in dehydrated crude oil and high precision requirements. We presents a method to measure water volume fraction in dehydrated crude oil with γ-ray densitometry. The Monte Carlo computer simulation packet GEANT4 was used to analyze the WVF measuring sensitivity of the γ-ray densitometry at different γ-ray energies, and effects of temperature, pressure, salinity and oil components on WVF measurement. The results show that the γ-ray densitometry has high sensitivity in γ-ray energy ranges of 16~25keV, and it can distinguish WVF changes of 0.0005. The calculated WVF decreases about 0.0002 with 1℃ of temperature increase and they have approximately linear relation with temperature when water volume fraction remains the same. Effects of pressure, salinity and oil components on water volume fraction can be neglected. Experiments were done to analyze sensitivity of the γ-ray densitometry. The results , as compared with simulations, demonstrate that simulation method is reliable and it is feasible to gauge low water volume fraction using low energy γ-rays.
基金the financial support of Liaoning Province Education Department Project(2004D06)
文摘Removal of water contained in extra-viscous crude oil is quite difficult because of the high viscosity and high resins content of heavy oil.The microwave technology was introduced for the separation of water from high-viscosity crude oil in the presence of sodium acetate.The decrease in zeta-potential of interface and the viscosity of crude oil are responsible for the accelerated separation of water under microwave irradiation.The influences of the concentration of sodium acetate in sample,irradiation pressure,irradiation time and irradiation power on the separation efficiency were investigated.The optimum technological condition for the refining process was determined.Upon treating the sample 1 (with a water concentration of 50%),the water removal rate was 98.44%,when the optimum conditions were identified to be a sodium acetate concentration of 2%,an irradiation pressure of 0.1 MPa,an irradiation time of 2 min,and an irradiation power of 225 W,with the recovery of sodium acetate reaching 97.88%.Upon treating the sample 2 (the concentration of water was 20%),the water removal rate was 93.85%,when the optimum conditions were determined to be a sodium acetate concentration of 3%,an irradiation pressure of 0.1 MPa,an irradiation time of 4 min,and an irradiation power of 375 W,with the recovery of sodium acetate reaching 93.54%.By using this method,the dehydration efficiency was increased rapidly.