Respiratory motion correction with an improved demons algorithm for PET images
1
作者 高娟 柴培 +3 位作者 贠明凯 刘双全 单保慈 魏龙 《Chinese Physics C》 SCIE CAS CSCD 2012年第10期1025-1030,共6页
Respiratory motion is a major factor that affects the quality of PET images of the thoracic area. The diaphragm moves about 15–20 mm due to respiratory motion, which substantially degrades the effective spatial resol... Respiratory motion is a major factor that affects the quality of PET images of the thoracic area. The diaphragm moves about 15–20 mm due to respiratory motion, which substantially degrades the effective spatial resolution of PET. In this paper, a gated acquisition method is used to correct the motion effects. In this method, an improved demons algorithm is proposed to align the gated images. The experimental results show that the quality of PET images is significantly improved when using our improved method and the proposed method has a faster convergence rate than the original demons algorithm. 展开更多
关键词 motion correction demons algorithm DISCONTINUITY PET