This review highlights the recent advances in X-ray microcomputed tomography (Micro-CT) applied in dental research. It summarizes Micro-CT applications in mea- surement of enamel thickness, root canal morphology, ev...This review highlights the recent advances in X-ray microcomputed tomography (Micro-CT) applied in dental research. It summarizes Micro-CT applications in mea- surement of enamel thickness, root canal morphology, evaluation of root canal preparation, craniofacial skeletalstructure, micro finite element modeling, dental tissue engineering, mineral density of dental hard tissues and about dental implants. Details of studies in each of these areas are highlighted along with the advantages of Micro-CT, and finally a summary of the future applications of Micro-CT in dental research is given.展开更多
Objective To observe the effect of high positive acceleration(+Gz) environment on dental implant osseointegration in a rabbit model and to investigate its mechanism.Methods Forty-eight New Zealand white rabbits were r...Objective To observe the effect of high positive acceleration(+Gz) environment on dental implant osseointegration in a rabbit model and to investigate its mechanism.Methods Forty-eight New Zealand white rabbits were randomly divided into 6 groups. The rabbit’s mandibular incisors were extracted and 1 implant was placed in each socket immediately. After 1 week of rest, the rabbits were exposed to a high +Gz environment, 3 times a week. The rabbits were sacrificed at 3 weeks(2 weeks +Gz exposure), 5 weeks(4 weeks +Gz exposure), and 12 weeks(4 weeks +Gz exposure and 7 weeks normal environment) after surgery, respectively. Specimens were harvested for micro-CT scanning, histological analysis, and real-time polymerase chain reaction examination.Results Compared with those in the control group, the mRNA expression levels of bone morphogenetic protein-2(BMP-2), osteopontin(OPN), and transforming growth factor-β1(TGF-β1)were significantly lower(P < 0.05), while the mRNA expression level of receptor activator of nuclear factor κB ligand(RANKL) and the RANKL/osteoprotegerin(OPG) ratio were significantly higher(P < 0.05)at 3 weeks;values of bone volume fraction, trabecular number, bone-implant contact(BIC), and TGF-β1 and OPG mRNA expression levels were significantly lower(P < 0.05), and the value of trabecular separation, RANKL mRNA expression level and RANKL/OPG ratio were significantly higher(P < 0.05) at 5 weeks;and the value of BIC was still significantly lower(P < 0.05) at 12 weeks in the experimental group.Conclusion Early exposure to the high +Gz environment after implant surgery might have an adverse effect on osseointegration, and its mechanism could be related to the inhibition of osteoblast activity and promotion of osteoclast activity.展开更多
文摘This review highlights the recent advances in X-ray microcomputed tomography (Micro-CT) applied in dental research. It summarizes Micro-CT applications in mea- surement of enamel thickness, root canal morphology, evaluation of root canal preparation, craniofacial skeletalstructure, micro finite element modeling, dental tissue engineering, mineral density of dental hard tissues and about dental implants. Details of studies in each of these areas are highlighted along with the advantages of Micro-CT, and finally a summary of the future applications of Micro-CT in dental research is given.
基金financially supported by China Postdoctoral Science Foundation [No.2016M592971]Logistics Department of the Chinese People’s Liberation Army [No.AKJ15J003]
文摘Objective To observe the effect of high positive acceleration(+Gz) environment on dental implant osseointegration in a rabbit model and to investigate its mechanism.Methods Forty-eight New Zealand white rabbits were randomly divided into 6 groups. The rabbit’s mandibular incisors were extracted and 1 implant was placed in each socket immediately. After 1 week of rest, the rabbits were exposed to a high +Gz environment, 3 times a week. The rabbits were sacrificed at 3 weeks(2 weeks +Gz exposure), 5 weeks(4 weeks +Gz exposure), and 12 weeks(4 weeks +Gz exposure and 7 weeks normal environment) after surgery, respectively. Specimens were harvested for micro-CT scanning, histological analysis, and real-time polymerase chain reaction examination.Results Compared with those in the control group, the mRNA expression levels of bone morphogenetic protein-2(BMP-2), osteopontin(OPN), and transforming growth factor-β1(TGF-β1)were significantly lower(P < 0.05), while the mRNA expression level of receptor activator of nuclear factor κB ligand(RANKL) and the RANKL/osteoprotegerin(OPG) ratio were significantly higher(P < 0.05)at 3 weeks;values of bone volume fraction, trabecular number, bone-implant contact(BIC), and TGF-β1 and OPG mRNA expression levels were significantly lower(P < 0.05), and the value of trabecular separation, RANKL mRNA expression level and RANKL/OPG ratio were significantly higher(P < 0.05) at 5 weeks;and the value of BIC was still significantly lower(P < 0.05) at 12 weeks in the experimental group.Conclusion Early exposure to the high +Gz environment after implant surgery might have an adverse effect on osseointegration, and its mechanism could be related to the inhibition of osteoblast activity and promotion of osteoclast activity.