期刊文献+
共找到297篇文章
< 1 2 15 >
每页显示 20 50 100
Impact of Dentinal Tubule Orientation on Dentin Bond Strength
1
作者 Jing GUO Li-ping WANG +2 位作者 Jia ZHU Jian YANG Hong-shui ZHU 《Current Medical Science》 SCIE CAS 2018年第4期721-726,共6页
This study aimed to determine the impact of dentinal tubule orientation on dentin bond strength to provide a reference for clinical cavity preparation in resin-bonded restoration. Patients aged 13-16 years were select... This study aimed to determine the impact of dentinal tubule orientation on dentin bond strength to provide a reference for clinical cavity preparation in resin-bonded restoration. Patients aged 13-16 years were selected, including 18 males and 21 females. Forty-eight human maxillary first premolars from orthodontic extractions were chosen to prepare the test models with the dentinal tubule orientations perpendicular and parallel to the bonding substrate. The test models in the vertical and parallel groups were divided into three groups: total-etching with 20% phosphoric acid, total-etching with 35% phosphoric acid and self-etching, with the dentinal tubule surfaces bonded with composite resin blocks in each group. After the standard test models of dentinal tubule-composite resin blocks were placed in distilled water and stored at 37℃ for 24 h, shearing tests were performed using a universal material testing machine at a crosshead speed of 0.5 mm/min. The bond strength values in the vertical group were 19.33+1.59 MPa for the 20% phosphoric acid group, 21.39±2.34 MPa for the 35% phosphoric acid group, and 16.88±1.54 MPa for the self-etching group. The bond strength values in the parallel group were 24.53±1.99 MPa for the 20% phosphoric acid group, 25.16+2.88 MPa for the 35% phosphoric acid group, and 20.83±1.99 for the self-etching group. After using same total-etching adhesive, the shear bond strength of the parallel group was higher than that of the vertical group, and the difference was statistically significant (P〈0.05). Regardless of vertical group or parallel group, the difference in the bond strength value between the total-etching groups and the self-etching group was statistically significant (P〈0.05). It was concluded that the dentin bonding substrate which was parallel to the direction of the dentin tubule achieved an improved bond strength; the total-etching adhesives achieved higher bond strengths in dentin bond than the self-etching adhesives. 展开更多
关键词 dentinal tubule orientation bonding substrate shear bond strength
下载PDF
Isotropic shear bond strength behavior of superficial bovine dentin: A pilot study 被引量:1
2
作者 Camila Sabatini Sebastiano Andreana 《Open Journal of Stomatology》 2013年第1期1-7,共7页
The aim of this pilot study was to evaluate the shear bond strength of superficial bovine incisor dentin in different crown regions. Bonding was performed to the incisal, middle and cervical thirds of superficial bovi... The aim of this pilot study was to evaluate the shear bond strength of superficial bovine incisor dentin in different crown regions. Bonding was performed to the incisal, middle and cervical thirds of superficial bovine coronal dentin (n = 20) with a two-step etch-and-rinse adhesive (Optibond Solo Plus) and resin composite (Z100). Shear bond strength was evaluated at 24 h and failure modes of representative specimens wereobserved with FE-SEM. Non-parametric Kruskal-Wallis test with a significance level of 0.05 was used for data analysis. Mean shear bond strength values for the incisal, middle, and cervical thirds were 36.9 (3.1), 42.6 (2.6), and 37.1 (2.1) respectively with no significant differences evidenced between the crown thirds (p = 0.19). Observation of the failure mode of representative specimens demonstrated that specimens with high bond strength values exhibited predominantly mixed-type failures whereas low strength specimens exhibited adhesive failures between the dentin and adhesive. The absence of significant differences in shear bond strength between crown thirds indicate that, regardless of tubule orientation, any crown region can be used when superficial bovine incisor dentin is used for shear bond strength testing. 展开更多
关键词 Adhesion SHEAR bond strength BOVINE dentin ISOTROPIC Properties Failure Mode
下载PDF
Immediate and delayed micro-tensile bond strength of different luting resin cements to different regional dentin 被引量:1
3
作者 Abdelraheem Mohamed Ali Ibrahim Mohamed Hamouda +1 位作者 Mohamed Hamed Ghazy Manal Mohamed Abo-Madina 《The Journal of Biomedical Research》 CAS 2013年第2期151-158,共8页
We sought to evaluate immediate and delayed micro-tensile bond strength of Panavia F2.0 and Multilink Sprint resin cement to superficial, deep and cervical dentin. Thirty-six freshly extracted non-carious human molars... We sought to evaluate immediate and delayed micro-tensile bond strength of Panavia F2.0 and Multilink Sprint resin cement to superficial, deep and cervical dentin. Thirty-six freshly extracted non-carious human molars were sectioned in the mesiodistal direction to expose three different dentin regions including superficial dentin (1 mm below the dentine-enamel junction), deep dentin (1 mm above the highest pulp horn) and cervical dentin (0.5 mm above the cemento-enamel junction and 0.5 mm below the dentine-enamel junction). Resin cements were applied on dentin surfaces and composite blocks were luted under constant seating pressure. Each group was divided into three subgroups according to time intervals. Specimens were sectioned to obtain sticks of 1 mm2 in diameter and subjected to microtensile bond strength testing at a cross head speed of 1 mrn/min. Both resin cements showed higher micro-tensile bond strength to superficial dentin than that to deep or cervical dentin (P 〈 0.001). Micro-ten- sile bond strengths of Panavia F2.0 were higher than those of Multilink Sprint at different dentin regions (P 〈 0.001). Immediate "micro-tensile bond strengths were higher than those of delayed micro-tensile bond strengths for both resin cements (P 〈 0.001). It was concluded that resin cements with different chemical formulations and applications yield significantly different micro-tensile bond strengths to different dentin regions. 展开更多
关键词 immediate and delayed micro-tensile bond strength luting resin cements regional dentin
下载PDF
Comparison of Two Methods of Chlorhexidine Application of Shear Bond Strength Degradation between Composite Resin and Dentin
4
作者 Endang Suprastiwi Itja Risanti Nila Kesuma Djauharie 《Open Journal of Stomatology》 2015年第8期211-216,共6页
Background: Chlorhexidine could have effect on shear bond strength of composite resin-dentin. Objective: The purpose of this study is to compare two methods of chlorhexidine application of shear bond strength degradat... Background: Chlorhexidine could have effect on shear bond strength of composite resin-dentin. Objective: The purpose of this study is to compare two methods of chlorhexidine application of shear bond strength degradation between composite resin and dentin. Methods: Thirty samples of dentin were taken from the crown of premolars and then divided into three groups (n = 10). Group 1 were applied bonding without chlorhexidine, group 2 were applied with liquid chlorhexidine and followed by bonding, group 3 were applied bonding which contains chlorhexidine. Each group was divided into two sub-groups (n = 5): the group with and without 10% NaOCl immersion for one hour. Then, 4 samples in each sub-group were used to measure shear bond strength using Universal Testing Machine, and 1 sample was examined with Scanning Electron Microscope (SEM). Data were analyzed using SPSS 17 by Mann-Whitney and Kruskal Wallis test. Results: The highest mean shear bond strength without 10% NaOCl immersion was in group 1, while the highest mean with 10% NaOCl immersion was in group 3. Significant differences occurred between the groups 1 and 2, groups 2 and 3. Conclusion: Method of using bonding contains chlorhexidine can increase and inhibit degradation shear bond strength between composite resin and dentin. 展开更多
关键词 CHLORHEXIDINE Composite RESIN dentin SHEAR bond strength
下载PDF
Surface preparation and isotropic shear bond strength properties of superficial bovine dentin
5
作者 Camila Sabatini Sebastiano Andreana Zhe Wu 《Open Journal of Stomatology》 2013年第4期273-280,共8页
The effect of different types of surface preparation with SiC abrasive paper on the shear bond strength (SBS) of superficial bovine dentin obtained from the incisal, middle and cervical thirds were evaluated. Dentin s... The effect of different types of surface preparation with SiC abrasive paper on the shear bond strength (SBS) of superficial bovine dentin obtained from the incisal, middle and cervical thirds were evaluated. Dentin substrates were obtained with twenty specimens for each locationgrit combination. Superficial dentin was exposed and prepared to 120-, 320-, or 600-grit SiC;the dentin surfaces were treated with Optibond Solo Plus (Kerr) and polymerized for 20 s. The specimens were placed in a jig, filled with resin composite Z100 (3M-ESPE), polymerized for 40 s according to manufacturer’s instructions, and stored for 24 h at 37℃ and 100% humidity. After 24 h, SBS was measured using a loading testing machine (Ul-tradent) and expressed in megapascals. A two-way ANOVA and Tukey test were used for data analysis. No statistically significant effect of the location (P = 0.254) or interaction grit-location (P = 0.629) were observed on SBS. Statistically significant effect of the grit on the SBS was detected (P < 0.001) with 320-grit being statistically different from 600-grit (P = 0.011) and 120-grit (P < 0.001). No significant differences were observed between 600-grit and 120-grit (P = 0.413). Regardless of the location, 320-grit consistently showed the lowest SBS indicating that different surface grit preparations have an effect on dentin SBS values. 展开更多
关键词 RESIN Composite dentin Adhesion bond strength ISOTROPIC Surface Preparation Failure Mode
下载PDF
Influence of Phosphoric Acid Etching on the Bond Strength of a Universal Adhesive System to Caries-Affected Dentin 被引量:1
6
作者 Renata Pavanello Sérgio Luiz Pinheiro 《Advances in Biological Chemistry》 2018年第3期37-46,共10页
The purpose of this study was to evaluate the influence of acid etching on the bond strength of a universal adhesive system (Single Bond Universal, 3M) to caries-affected dentin. Forty permanent third molars were sele... The purpose of this study was to evaluate the influence of acid etching on the bond strength of a universal adhesive system (Single Bond Universal, 3M) to caries-affected dentin. Forty permanent third molars were selected and carious lesions were induced by the microbiological method with?S. mutans?ATCC25175. Teeth were allocated randomly across four experimental designs (n?=?10): PA-I: phosphoric acid etching and application of the adhesive system, followed by immediate microtensile bond strength testing;PA-CC: phosphoric acid etching and application of the adhesive system, followed by microtensile bond strength testing after a 14-day cariogenic challenge;NPA-I: application of the adhesive system without acid etching, followed by immediate bond strength testing and NPA-CC: application of the adhesive system without acid etching followed by bond strength testing after 14-day cariogenic challenge. For microtensile bond strength testing,?a restoration with Charisma composite resin was made and each specimen was sectioned with a cross-sectional area of 1 mm2. Only adhesive and mixed fractures were considered for bond strength calculation. Results were evaluated by the Kruskal-Wallis and Friedman tests. The highest bond strengths were observed in the phosphoric acid etching groups (p??0.05). Cariogenic challenge did not affect bond strength (p?>?0.05). The predominant fracture type was adhesive. We conclude that phosphoric acid increased the bond strength of the Single Bond Universal system to caries-affected dentin, and that cariogenic challenge did not interfere with this bond strength. 展开更多
关键词 Caries-Affected dentin UNIVERSAL Adhesives Hybrid Layer Collagen Fibers MICROTENSILE bond strength
下载PDF
Push-out Bond Strength of Self-adhesive Methacrylate Resin-based Sealers to Root Dentin
7
作者 孙燕 李宇红 樊明文 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第1期108-113,共6页
This study examined the adhesive strength of two self-adhesive methacrylate resin-based sealers(MetaSEAL and RealSeal SE) to root dentin and compared them with RealSeal and AH Plus in properties. A total of 48 extra... This study examined the adhesive strength of two self-adhesive methacrylate resin-based sealers(MetaSEAL and RealSeal SE) to root dentin and compared them with RealSeal and AH Plus in properties. A total of 48 extracted human single-rooted teeth were used to prepare the 0.9-mm thick longitudinal tooth slice(each per tooth). Standardized simulated canal spaces of uniform dimensions were prepared in the middle of radicular dentin. After treated with 5.25% sodium hypochlorite(NaOCl) and 17% EDTA, tooth slices were allocated randomly to four groups(n=12) in terms of different sealers used: MetaSEAL, RealSeal SE, RealSeal, and AH plus groups. The simulated canal spaces were obturated with different sealers in each group. There were 10 slabs with 20 simulated canal spaces(n=20) used in each group for push-out testing. The failure modes and the ultrastructures of fractured sealer-dentin interfaces were examined. The remaining 2 slabs in each group underwent partial demineralization for observation of the ultrastructure of resin tags. The results showed that the push-out bond strength was 12.01±4.66 MPa in MetaSEAL group, significantly higher than that in the other three groups(P0.05). Moreover, no statistically significant differences were noted in the push-out bond strength between RealSeal SE(5.43±3.68 MPa) and AH Plus(7.34±2.83 MPa) groups and between RealSeal SE and RealSeal(2.93±1.76 MPa) groups(P0.05). Mixed failures were predominant in the fractured sealer-dentin interfaces in MetaSEAL and AH Plus groups, while adhesive failures were frequently seen in RealSeal SE and RealSeal groups. In conclusion, after complete removal of the smear layer, MetaSEAL showed superior bond ability to root dentin. The RealSeal SE is applicable in clinical practice, with its adhesive strength similar to that of AH Plus. The self-adhesive methacrylate resin-based sealer holds promise for use in endodontic treatment. 展开更多
关键词 endodontic sealer push-out bond strength adhesive interface raidicular dentin
下载PDF
Bonding Efficacy of a Self-adhesive Resin Cement to Enamel and Dentin 被引量:1
8
作者 王林虎 XU Haixing +4 位作者 LI Songyang 施斌 LI Rong YE Mingfu YANG Jing 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2014年第6期1307-1312,共6页
With the objective to evaluate the bonding efficacy of a new self-adhesive resin cement(RelyX Unicem, 3M ESPE) to enamel and dentin using a shear bonding strengths test with or without acid etching pretreatment, fla... With the objective to evaluate the bonding efficacy of a new self-adhesive resin cement(RelyX Unicem, 3M ESPE) to enamel and dentin using a shear bonding strengths test with or without acid etching pretreatment, flat buccal dentin surface and mesial/distal enamel surface were made using a high-speed diamond bur. Copper rings were luted using Rely X Unicem(RU; 3M ESPE), Panavia F(PF; Kuraray) or Vitique(VI; DMG). For RU, the shear bonding strengths using GL(Gluma Etch, Heraeus) acid etching pretreatment were also tested. The teeth were placed into copper rings(inner diameter: 16 mm, height: 4mm) and embedded in methylmethacrylate resin. The specimens were stored for 24 h in distilled water at 37 ℃ prior to shear bonding strengths testing. In addition, bond failures were examined by optical microscope and categorized as 4 models such as different adhesive, cohesive, or mixed. Shear bonding strengths were calculated by dividing the maximum debonding force over the cross sectional area of each specimen. The Kruskal-Wallis test was used to determine pairwise statistical differences(P 〈 0.05) in SBS between the experimental groups. For dentin bonding strength, statistical analysis showed that there was no significant difference among RU(12.84 MPa), PF(14.93 MPa) and VI(11.03 MP); and the bonding strengths of them were higher than RU with acid etching pretreatment(9.12 MP). When bonded to enamel, PF(17.99 MP) and VI(17.58 MP) scored significantly higher than RU efficacy.The use of self-adhesive cement Rely X Unicem can obtain the bonding strengths to dentin similar to traditional resin cements. Phosphoric acid etching can improve the bonding strengths of the selfadhesive resin cement to enamel, but was negative for dentin. 展开更多
关键词 RelyX Unicem dentin enamel shear bond strength
下载PDF
An in Vitro Comparison of Bonding Effectiveness of Different Adhesive Strategies on Erbium:Yttrium-Alluminum-Garnet Laser Irradiated Dentin 被引量:1
9
作者 Daniele Scaminaci Russo Jacopo Buti Luca Giachetti 《Open Journal of Stomatology》 2016年第1期1-11,共11页
Background: To date there is not a material considered ideal for the lased dentin. Objective: To compare the bond strength to human lased dentin of self-etch and etch-and-rinse adhesive systems, a self-adhesive resin ... Background: To date there is not a material considered ideal for the lased dentin. Objective: To compare the bond strength to human lased dentin of self-etch and etch-and-rinse adhesive systems, a self-adhesive resin composite and a glass-ionomer cement. Methods: Forty human molars were sectioned to obtain a 2 mm-thick slab of mid-coronal dentin. The occlusal surface of each slab was polished by SiC paper (P600) for 10 s. Then an half part of dentin slabs was randomly selected for receiving treatment with 2.94 μm Er:YAG laser (DEKA, Smart 2940D Plus) with 10 Hz at 100 mJ, pulse duration of 230 μs with contact tip. Dentin slabs were randomly divided into four groups (n = 10). Six conical frustum-shaped build-ups were constructed on the occlusal surface of each dentin slab using bonding agents (OptiBond Solo Plus Group 1;OptiBond All-in-one Group 2) combined with a resin composite (Premise Flow), self-adhesive resin composites (Vertise Flow Group 3) and a glass-ionomer cement (Ketac-Fil Group 4). Specimens were subjected to μSBS test. Data were analyzed by a mixed model and Tukey’s test. Results: Measured bond strengths were (mean ± standard deviation): 20.8 ± 5.5 MPa (laser treatment) and 15.6 ± 4.5 MPa (SiC paper) for Group 1, 18.9 ± 5.3 MPa (laser treatment) and 14.0 ± 4.3 MPa (SiC paper) for Group 2, 7.9 ± 2.8 MPa (laser treatment) and 4.3 ± 2.2 MPa (SiC paper) for Group 3, 4.7 ± 1.9 MPa (laser treatment) and 2.6 ± 1.2 MPa (SiC paper) for Group 4. The inferential analysis showed that the dentin laser treatment significantly affected the bond strength within each individual group. On dentin treated with laser the bond strengths recorded for build-ups constructed with etch and rinse and self-etch adhesive systems were significantly higher than those recorded for build-ups constructed with self-adhesive resin composite and glass-ionomer cement (p < 0.0001). Similarly, on dentin treated with SiC paper the bond strengths recorded for build-ups constructed with etch and rinse and self-etch adhesive systems were significantly higher than those recorded for build-ups constructed with self-adhesive resin composite and glass-ionomer cement (p < 0.0001). Conclusion: Er:YAG laser treatment has increased the shear bond strength of all the adhesive materials used. 展开更多
关键词 Adhesion Micro Shear bond strength Test dentin Restorative Materials
下载PDF
Multiple Coatings can Improve the Bond Durability of One-step Self-etching Adhesive to Primary Dentin
10
作者 Lin Ma Jian-feng Zhou +2 位作者 Quan Jing Ji-zhi Zhao Kuo Wan 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第2期106-111,共6页
Objective To investigate whether multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin.Methods Twelve caries-free human primary molars were randomly divided into 2 group... Objective To investigate whether multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin.Methods Twelve caries-free human primary molars were randomly divided into 2 groups.In group 1,each tooth was hemisected into 2 halves.One half was assigned to the control subgroup 1,which was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instructions;the other half was assigned to experimental subgroup 1,in which the adhesive was applied three times before light curing.In group 2,one split half tooth was bonded with a commercially available one-step self-etching adhesive according to the manufacturer's instructions;for the other half,three layers of adhesive were applied with each successive layer of light curing.Specimens were stored in 0.9% NaCl containing 0.02% sodium azide at 37℃ for 18 months and then were subjected to microtensile bond strength test and the fracture mode analysis.Results When the adhesive was applied three times before light curing,the bond strength of the experimental subgroup 1 was significantly higher than that of the control subgroup 1(47.46±13.91 vs.38.12±11.21 MPa,P<0.05).When using the technique of applying multiple layers of adhesive with each successive layer of light curing,no difference was observed in bond strength between the control subgroup and the experimental subgroup(39.40±8.87 vs.40.87±9.33 MPa,P>0.05).Conclusion Multiple coatings can improve the bond durability of one-step self-etching adhesive to primary dentin when using the technique of light-curing after applying 3 layers of adhesive. 展开更多
关键词 耐久性 牙本质 酸蚀 粘接 债券 涂料 光固化胶粘剂 原发性
下载PDF
Er:YAG激光和传统车针去龋后牙本质粘接强度的比较
11
作者 黄莉莉 张佳钰 《医疗卫生装备》 CAS 2024年第4期56-60,共5页
目的:比较使用不同模式Er:YAG激光以及传统车针去龋后牙本质与复合树脂的粘接强度。方法:选用人类离体磨牙模拟龋坏,分别采用Er:YAG激光中短脉冲(medium short pulse,MSP)模式、Er:YAG激光超短脉冲(super short pulse,SSP)模式和传统车... 目的:比较使用不同模式Er:YAG激光以及传统车针去龋后牙本质与复合树脂的粘接强度。方法:选用人类离体磨牙模拟龋坏,分别采用Er:YAG激光中短脉冲(medium short pulse,MSP)模式、Er:YAG激光超短脉冲(super short pulse,SSP)模式和传统车针去除模拟的龋坏后,采用自酸蚀粘接剂将牙体标本与复合树脂粘接制成试件。使用万能试验机对试件进行拉伸试验,测得断裂负荷和粘接强度,并采用单因素方差分析和Tukey多重比较进行统计学分析。采用扫描电子显微镜观察3种不同去龋方式处理后的牙本质表面形态,以及涂布自酸蚀粘接剂并固化后试件的横截面形态。结果:使用Er:YAG激光MSP模式处理后牙本质与复合树脂的粘接强度最高,SSP模式处理后次之,传统车针处理后最低,但差异无统计学意义(P>0.05)。扫描电子显微镜图像显示,Er:YAG激光MSP模式处理后的牙本质表面较平坦,牙本质小管内几乎没有残屑;Er:YAG激光SSP模式处理后的牙本质表面呈现鳞片状,牙本质小管内可见少量碎屑;而传统车针处理后牙本质小管大部分处于被表面牙本质部分甚至完全遮盖的状态,牙本质小管内充满残屑。结论:使用Er:YAG激光去龋相比传统车针去龋可以获得较好的牙本质粘接强度,且对牙本质小管的处理深度和洁净度明显优于传统车针去龋,其中MSP模式更佳。 展开更多
关键词 ER:YAG激光 传统车针 去龋 牙本质 粘接强度
下载PDF
Primer containing dimethylaminododecyl methacrylate kills bacteria impregnated in human dentin blocks 被引量:4
12
作者 Chen Chen Lei Cheng +4 位作者 Michael D Weir Nancy J Lin Sheng Lin-Gibson Xue-Dong Zhou Hockin HK Xu 《International Journal of Oral Science》 SCIE CAS CSCD 2016年第4期239-245,共7页
Antibacterial dimethylaminododecyl methacrylate (DMADDM) was recently synthesized. The objectives of this study were to: (1) investigate antibacterial activity of DMADDM-containing primer on Streptococcus mutans ... Antibacterial dimethylaminododecyl methacrylate (DMADDM) was recently synthesized. The objectives of this study were to: (1) investigate antibacterial activity of DMADDM-containing primer on Streptococcus mutans impregnated into dentin blocks for the first time, and (2) compare the antibacterial efficacy of DMADDM with a previous quaternary ammonium dimethacrylate (QADM). Scotchbond Multi-Purpose (SBMP) bonding agent was used. DMADDM and QADM were mixed into SBMP primer. Six primers were tested: SBMP control primer P, P+2.5% DMADDM, P+5% DMADDM, P+7.5% DMADDM, P+10% DMADDM, and P+10% QADM. S. mutans were impregnated into human dentin blocks, and each primer was applied to dentin to test its ability to kill bacteria in dentinal tubules. Bacteria in dentin were collected via a sonication method, and the colony-forming units (CFU) and inhibition zones were measured. The bacterial inhibition zone of P+10% DMADDM was 10 times that of control primer (P〈0.05). CFU in dentin with P+10% DMADDM was reduced by three orders of magnitude, compared with control. DMADDM had a much stronger antibacterial effect than QADM, and antibacterial efficacy increased with increasing DMADDM concentration. Dentin shear bond strengths were similar among all groups (P〉0.1). In conclusion, antibacterial DMADDM-containing primer was validated to kill bacteria inside dentin blocks, possessing a much stronger antibacterial potency than the previous QADM. DMADDM-containing bonding agent was effective in eradicating bacteria in dentin, and its efficacy was directly proportional to DMADDM mass fraction. Therefore, DMADDM may be promisine for use in bonding agents as well as in other restorative and oreventive materials to inhibit bacteria. 展开更多
关键词 antibacterial bonding agent dental restoration dentin bond strength dimethylaminododecyl methacrylate kil]ing bacteriain dentin Streptococcus mutans
下载PDF
Single Bond Universal牙本质粘结强度及牙本质保护作用的实验研究 被引量:2
13
作者 崔蜜 周秦 +3 位作者 郭忠军 杜阳 马惠珍 逯宜 《中国美容医学》 CAS 2017年第2期90-93,共4页
目的:探讨通用型粘结剂(Single Bond Universal,SBU)对牙本质的粘结强度。方法:选取A组(SBU)、B组(S3bond)和C组(hybrid coat,Hy C)三组不同类型处理剂,分别比较A组与B、C两组的牙本质微拉伸粘结强度。各组样本数量相同(n=30),结果通过... 目的:探讨通用型粘结剂(Single Bond Universal,SBU)对牙本质的粘结强度。方法:选取A组(SBU)、B组(S3bond)和C组(hybrid coat,Hy C)三组不同类型处理剂,分别比较A组与B、C两组的牙本质微拉伸粘结强度。各组样本数量相同(n=30),结果通过两独立样本t检验进行统计学分析(α=0.05),通过扫描电镜观察断裂模式。结果:A组拉伸强度约23.371MP,与B组间无统计学差异,显示了与B组同等的粘结强度;与C组(17.314MP)比较,A组显示了较高的粘结强度,两组间有显著的统计学差异。断裂模式显示,三组断裂都主要以界面断裂为主,A、B两组样本断面可见牙本质小管结构,C组可见极少量牙本质小管结构。结论:通用型粘结剂Single Bond Universal具备与传统自酸一步法粘结剂同等的粘结强度,可以满足临床粘结要求;Single Bond Universal作为牙本质保护膜用于即刻牙本质封闭时,对牙本质小管有一定的封闭作用,并且可以获得较hybrid coat牙本质保护膜更高的粘结力,但其对牙本质小管的封闭效果还有待进一步实验研究。 展开更多
关键词 牙本质 粘结 牙本质保护膜 微拉伸强度
下载PDF
铒激光预处理对牙本质、牙釉质粘结强度及CAD/CAM玻璃陶瓷嵌体修复牙体缺损边缘微渗漏的影响
14
作者 杨华旋 陈任生 +2 位作者 黄家辉 孔海影 张林林 《上海口腔医学》 CAS 2024年第3期245-249,共5页
目的:探讨铒激光预处理对牙本质、牙釉质粘结强度及CAD/CAM玻璃陶瓷嵌体修复牙体缺损边缘微渗漏的影响。方法:收集2020年1月—2023年1月口腔外科门诊拔除的新鲜、无龋坏变色、无隐裂智齿62颗,根据预处理方式不同,随机分为铒激光组和磷酸... 目的:探讨铒激光预处理对牙本质、牙釉质粘结强度及CAD/CAM玻璃陶瓷嵌体修复牙体缺损边缘微渗漏的影响。方法:收集2020年1月—2023年1月口腔外科门诊拔除的新鲜、无龋坏变色、无隐裂智齿62颗,根据预处理方式不同,随机分为铒激光组和磷酸组,每组31颗,每组再随机分为2份,分别用于粘结强度测试(16颗)和微渗漏测试(15颗)。比较2组牙釉质、牙本质抗剪切粘结强度和微渗漏程度及微渗漏评分分布情况。采用SPSS 17.0软件包对数据进行统计学分析。结果:铒激光组牙釉质、牙本质抗剪切粘结强度显著高于磷酸组(P<0.05);铒激光组侧壁、龈壁微渗漏程度显著低于磷酸组(P<0.05),铒激光组侧壁微渗漏评分主要为1分和2分,磷酸组侧壁微渗漏评分主要为2分,2组侧壁微渗漏评分分布相比,差异有统计学意义(P<0.05);铒激光组龈壁微渗漏评分主要为1分和2分,磷酸组龈壁微渗漏评分主要为2分和3分,2组龈壁微渗漏评分分布相比,差异有统计学意义(P<0.05)。结论:铒激光预处理可提高瓷嵌体与牙本质、牙釉质粘结强度,同时还可减少CAD/CAM玻璃陶瓷嵌体微渗漏,增强嵌体边缘密合性。 展开更多
关键词 铒激光 牙本质 牙釉质 粘结强度 CAD/CAM 玻璃陶瓷嵌体 微渗漏
下载PDF
诺丽对冠部牙本质粘接强度及纳米渗漏的影响
15
作者 周可莹 李艳萍 +3 位作者 李海清 何丽娜 潘爽 牛玉梅 《口腔疾病防治》 2024年第6期420-427,共8页
目的探讨诺丽(Morinda citrifolia juice,MCJ)联合乙二胺四乙酸盐(ethylene diaminete traacetic acid,EDTA)根管冲洗对冠部牙本质粘接强度及纳米渗漏的影响,并与临床上最常用的根管冲洗液次氯酸钠(sodi⁃um hypochlorite,NaClO)相比较,... 目的探讨诺丽(Morinda citrifolia juice,MCJ)联合乙二胺四乙酸盐(ethylene diaminete traacetic acid,EDTA)根管冲洗对冠部牙本质粘接强度及纳米渗漏的影响,并与临床上最常用的根管冲洗液次氯酸钠(sodi⁃um hypochlorite,NaClO)相比较,为临床应用提供参考。方法本研究已通过单位伦理审查委员会批准。选取63颗因正畸拔除的人前磨牙,去除表面釉质暴露牙本质平面后,根据冲洗液不同随机分为对照组(蒸馏水组)和6个实验组,即:A组2.5%NaClO、B组5.25%NaClO、C组6%MCJ、D组2.5%NaClO⁃17%EDTA、E组5.25%NaClO⁃17%EDTA和F组6%MCJ⁃17%EDTA(n=9),分别用相应冲洗液浸泡20 min后,在其表面分层堆积4 mm×4 mm×3 mm的Z350树脂块,每组选取6个样本,低速切割机将每个样本切割成1 mm×1 mm×8 mm的试件条,进行微拉伸粘接强度测试,随后在体视显微镜下观察断裂类型;每组剩余的3个样本经老化后切割成1 mm厚的薄片,进行界面纳米渗漏测试以及扫描电子显微镜下观察树脂⁃牙本质粘接界面。结果各组微拉伸粘接强度测试值均有显著性差异(P<0.05),对照组粘接强度最高。实验组中,B组粘接强度最低,以粘接界面破坏为主;F组粘接强度最高,以混合破坏为主。各组纳米渗漏值均有显著性差异(P<0.05),对照组纳米渗漏值最低。实验组中,B组纳米渗漏值最高、树脂突较细,F组纳米渗漏值最低、树脂突粗大且密集。结论NaClO浓度越高,冠部牙本质的粘接强度及边缘封闭性越差;MCJ联合EDTA根管冲洗对冠部牙本质的粘接强度和边缘封闭性的影响小于NaClO联合EDTA根管冲洗。 展开更多
关键词 牙本质 诺丽 次氯酸钠 复合树脂 微拉伸粘接强度 纳米渗漏 粘接界面 场发射扫描电子显微镜
下载PDF
不同浓度EDTA预处理对牙颈部非龋性硬化牙本质粘接性能的影响 被引量:2
16
作者 孙诚 董红 《湖北医药学院学报》 CAS 2023年第1期52-56,62,共6页
目的:研究不同浓度的乙二胺四乙酸(ethylenediamine tetraacetic acid,EDTA)预处理对牙颈部非龋性硬化牙本质粘接性能的影响。方法:收集60颗因重度牙周炎而拔除的符合纳入标准的前磨牙,随机分为4组(对照组、10%EDTA组、15%EDTA组、20%E... 目的:研究不同浓度的乙二胺四乙酸(ethylenediamine tetraacetic acid,EDTA)预处理对牙颈部非龋性硬化牙本质粘接性能的影响。方法:收集60颗因重度牙周炎而拔除的符合纳入标准的前磨牙,随机分为4组(对照组、10%EDTA组、15%EDTA组、20%EDTA组),每组各15颗,分别进行如下的3个实验,实验⑴:(1)对照组不作处理,其余三组分别用10%、15%、20%的EDTA处理60 s;(2)用第7代自酸蚀粘接剂可乐丽菲露粘接,分层充填树脂并光照(充填物高于洞缘5 mm),冷热循环5000次后制备微拉伸试件,进行微拉伸粘接强度测试后观察分析各组粘接界面的断裂模式和粘接强度。实验⑵:(1)同前;(2)将0.1%罗丹明B溶入可乐丽菲露粘接剂中,粘接、分层充填树脂并光照;(3)精密切割机切片后用倒置荧光显微镜观察、测量各组混合层厚度和树脂突长度。实验⑶:(1)同前;(2)可乐丽菲露粘接剂粘接,分层充填树脂并光照;(3)流体树脂封闭根尖、距充填物边缘1 mm均匀涂布2层指甲油后浸泡于0.1%罗丹明B的50%酒精溶液中冷热循环5000次;(4)精密切割机切片后倒置荧光显微镜观察分析各组微渗漏长度。结果:EDTA浓度愈大,树脂材料与牙颈部非龋性硬化牙本质间的微拉伸粘接强度越高、所形成的树脂突和混合层质量越高、粘接界面微渗漏的长度越小,即各组间差异存在统计学意义(P<0.05)。结论:EDTA可增强牙颈部非龋性硬化牙本质的粘接性能,且其浓度愈高,增强效果愈明显。 展开更多
关键词 乙二胺四乙酸 牙颈部非龋性硬化牙本质 粘接性能
下载PDF
氩气源低温常压等离子体改善牙本质⁃自酸蚀粘接界面粘接效果的体外研究 被引量:1
17
作者 王丹杨 刘增瑞 +3 位作者 李璇 丁鹏 谢娜 王路明 《口腔疾病防治》 2023年第1期23-27,共5页
目的探讨氩气源低温常压等离子体(nonthermal argonatmos phericpressure plasma,NTAPP)射流处理不同时间对牙本质⁃自酸蚀粘接剂粘接界面粘接强度及牙本质润湿性的影响。方法使用NTAPP发生装置(放电输入功率:9 W,氩气气体流量:5 L/min)... 目的探讨氩气源低温常压等离子体(nonthermal argonatmos phericpressure plasma,NTAPP)射流处理不同时间对牙本质⁃自酸蚀粘接剂粘接界面粘接强度及牙本质润湿性的影响。方法使用NTAPP发生装置(放电输入功率:9 W,氩气气体流量:5 L/min),分别处理5组(n=6)人牙本质试件(0、5、10、15、20 s)后,使用S3 Bond粘接剂处理牙面,制作微拉伸粘接试件并测量各组即刻粘接强度。同样参数、同样分组条件下处理牙本质面后测量牙本质表面接触角。结果随着NTAPP处理时间延长,牙本质即刻粘接强度呈显著上升趋势,以处理15 s组粘接强度最高(31.82±2.80)MPa。随着NTAPP处理时间延长,与阴性对照组牙本质表面接触角(75.57°±1.45°)相比,各实验组牙本质表面接触角均显著减小,以处理15 s组牙本质表面接触角(33.56°±2.14°)最低,湿润性最大。结论NTAPP处理可显著增加牙本质表面湿润性,提高与自酸蚀粘接剂粘接界面的粘接强度,这与处理时间相关。 展开更多
关键词 低温等离子体 氩气 自酸蚀粘接剂 牙本质 粘接界面 粘接强度 接触角 润湿性
下载PDF
乙醇酸对牙釉质和牙本质进行酸蚀的研究进展
18
作者 林令康 朱松 《口腔医学研究》 CAS CSCD 北大核心 2023年第11期952-955,共4页
在树脂粘接修复的过程中,牙釉质和牙本质的表面处理是关键步骤。目前,传统酸蚀剂常用的磷酸是一种强酸,容易对牙本质造成侵蚀性脱矿,影响树脂-牙本质粘接界面的长期稳定性。近年来,有研究将乙醇酸作为一种替代酸蚀剂,本文将介绍乙醇酸... 在树脂粘接修复的过程中,牙釉质和牙本质的表面处理是关键步骤。目前,传统酸蚀剂常用的磷酸是一种强酸,容易对牙本质造成侵蚀性脱矿,影响树脂-牙本质粘接界面的长期稳定性。近年来,有研究将乙醇酸作为一种替代酸蚀剂,本文将介绍乙醇酸的应用背景和酸蚀原理,重点针对使用乙醇酸酸蚀牙釉质和牙本质的酸蚀效果及与传统磷酸酸蚀相比的优势做一综述,以期为后续的临床研究提供参考。 展开更多
关键词 乙醇酸 酸蚀剂 牙釉质 牙本质 粘接强度
下载PDF
钻针类型对自酸蚀牙本质粘接强度的影响
19
作者 张玉玮 王文洁 +2 位作者 栗智 李冬雪 伍小臻 《医学研究杂志》 2023年第1期125-129,共5页
目的研究3种不同类型钻针牙体预备对自酸蚀牙本质粘接强度的影响。方法选用新鲜拔除的人第三磨牙,去除面釉质及浅层牙本质,暴露中层牙本质,制得牙本质平面试件。采用随机数字表法将试件分为3组,分别使用牙体预备用金刚砂钻针、磨光用金... 目的研究3种不同类型钻针牙体预备对自酸蚀牙本质粘接强度的影响。方法选用新鲜拔除的人第三磨牙,去除面釉质及浅层牙本质,暴露中层牙本质,制得牙本质平面试件。采用随机数字表法将试件分为3组,分别使用牙体预备用金刚砂钻针、磨光用金刚砂钻针和牙体预备用钨钢钻针进行牙本质表面预备,3种钻针的形态、直径和尖端设计相同。分别使用自酸蚀树脂粘接水门汀和自粘接树脂粘接水门汀进行粘接,测量牙本质粘接强度,观察其断裂模式。结果钨钢钻针组牙本质粘接强度(13.06±1.35MPa)最高,两种金刚砂钻针组之间牙本质粘接强度比较,差异无统计学意义(P>0.05)。结论两种金刚砂钻针比较,钨钢钻针预备的牙本质表面与自酸蚀类树脂粘接水门汀的粘接强度更高。 展开更多
关键词 牙本质 金刚砂 钨钢 粘接强度
下载PDF
原花青素对漂白后牙本质与复合树脂粘接强度的影响 被引量:1
20
作者 李姝宏 陈虹西 +2 位作者 周利平 杨倩 谢翠柳 《口腔疾病防治》 2023年第4期245-251,共7页
目的探讨原花青素对过氧化脲漂白后牙本质与复合树脂粘接强度的影响。方法按照牙本质粘接界面不同处理方法,将120颗人离体第三磨牙随机分为12组(n=10);W组(无漂白+去离子水)、Wa组(无漂白+去离子水+老化)、WT1组(无漂白+5%原花青素1 min... 目的探讨原花青素对过氧化脲漂白后牙本质与复合树脂粘接强度的影响。方法按照牙本质粘接界面不同处理方法,将120颗人离体第三磨牙随机分为12组(n=10);W组(无漂白+去离子水)、Wa组(无漂白+去离子水+老化)、WT1组(无漂白+5%原花青素1 min)、WT1a组(无漂白+5%原花青素1 min+老化)、WT2组(无漂白+5%原花青素5 min)、WT2a组(无漂白+5%原花青素5 min+老化)、C组(过氧化脲+去离子水)、Ca组(过氧化脲+去离子水+老化)、CT1组(过氧化脲+5%原花青素1 min)、CT1a组(过氧化脲+5%原花青素1 min+老化)、CT2组(过氧化脲+5%原花青素5 min)、CT2a组(过氧化脲+5%原花青素5 min+老化);上述各组在即刻或冷热循环老化后,万能力学试验机测试粘接强度,扫描电镜观察粘接界面微观形貌和纳米渗漏。结果CT1组经原花青素处理1 min(P<0.001)和CT2组经原花青素处理5 min(P<0.001)的漂白即刻组粘接强度均高于对照组C组,差异具有统计学意义,但CT1与CT2之间差异无统计学意义(P=1.000);冷热循环处理后各组粘接强度均下降,W与Wa(P<0.001)、C与Ca(P<0.001)的差异具有统计学意义,但CT1与CT1a(P=0.052)、CT2与CT2a(P=0.053)之间的差异无统计学意义。“漂白”(P<0.001)、“老化”(P<0.001)、“原花青素”(P<0.001)主效应和二阶交互效应“漂白*原花青素”(P=0.008)、“漂白*老化”(P=0.024)、“老化*原花青素”(P<0.001)均有统计学意义。扫描电镜示即刻组C、CT1和CT2组混合层欠清晰,老化组Ca、CT1a和CT2a组混合层局部破坏崩解,背散射模式下Ca组混合层存在大量硝酸银颗粒,CT1a、CT2a组混合层残留银离子减少。结论5%原花青素预处理1 min即可提高过氧化脲漂白后牙本质与复合树脂的即刻粘接强度并改善粘接耐久性。 展开更多
关键词 原花青素 牙齿漂白 过氧化脲 牙本质粘接 复合树脂 粘接强度 微观形貌 纳米渗漏 粘接耐久性
下载PDF
上一页 1 2 15 下一页 到第
使用帮助 返回顶部