The exergy losses and thermodynamic efficiency of MSF plant with brine recirculation are discussed bymeans of temperature difference functions proposed by the auther.In a MSF plant,the irreversible losses are found ma...The exergy losses and thermodynamic efficiency of MSF plant with brine recirculation are discussed bymeans of temperature difference functions proposed by the auther.In a MSF plant,the irreversible losses are found mainly in irreversible heat-transfer and flash evaporationprocesses.However,the basic variables are the temperature drop from stage to stage and the temperaturedifferences between flashed vapor and cooling water.In this paper,the flash temperature difference func-tion,the heat transfer temperature difference function and the total temperature difference function are sug-gested.The proposed temperature difference functions of MSF plant provide a convenient tool to analyse theirreversible behavior and evaluate the exergetic efficiency of this system,because without such improvement thecalculation of the exergetic efficiency of a MSF plant according to the classical formula will be not onlyinconvenient but also insignificant.As a result of present analysis,the reasonable parameters based on theenergy consumption are easily chosen.The above-mentioned principles are confirmed by commercial plants and a pilot plant in Tianjin.展开更多
Subject Code:A04With the support by the National Natural Science Foundation of China and the State Key Program for Basic Research of China,the research team led by Prof.Zhu Jia(朱嘉)at the National Laboratory of Solid...Subject Code:A04With the support by the National Natural Science Foundation of China and the State Key Program for Basic Research of China,the research team led by Prof.Zhu Jia(朱嘉)at the National Laboratory of Solid State Microstructures,College of Engineering and Applied Sciences,Nanjing University,improved the efficiency of solar desalination using graphene oxide film through suppressing the conduction loss。展开更多
文摘The exergy losses and thermodynamic efficiency of MSF plant with brine recirculation are discussed bymeans of temperature difference functions proposed by the auther.In a MSF plant,the irreversible losses are found mainly in irreversible heat-transfer and flash evaporationprocesses.However,the basic variables are the temperature drop from stage to stage and the temperaturedifferences between flashed vapor and cooling water.In this paper,the flash temperature difference func-tion,the heat transfer temperature difference function and the total temperature difference function are sug-gested.The proposed temperature difference functions of MSF plant provide a convenient tool to analyse theirreversible behavior and evaluate the exergetic efficiency of this system,because without such improvement thecalculation of the exergetic efficiency of a MSF plant according to the classical formula will be not onlyinconvenient but also insignificant.As a result of present analysis,the reasonable parameters based on theenergy consumption are easily chosen.The above-mentioned principles are confirmed by commercial plants and a pilot plant in Tianjin.
文摘Subject Code:A04With the support by the National Natural Science Foundation of China and the State Key Program for Basic Research of China,the research team led by Prof.Zhu Jia(朱嘉)at the National Laboratory of Solid State Microstructures,College of Engineering and Applied Sciences,Nanjing University,improved the efficiency of solar desalination using graphene oxide film through suppressing the conduction loss。