This paper reviews the principle and application of the thermally activated desiccant cooling systems with their capability to perform efficiently in hot-humid climates.The paper first introduces the continuous increa...This paper reviews the principle and application of the thermally activated desiccant cooling systems with their capability to perform efficiently in hot-humid climates.The paper first introduces the continuous increase of thermal comfort required in building and their relation with the consumption of conventional energy sources.The importance of desiccant cooling technology and its applications has been introduced as well.The energy and environmental issues with the conventional energy supply and the demand with the environmental problems and conditions mainly related to indoor air quality have been also discussed in the second chapter of this paper.The third part of this paper deals with different techniques and systems applied for cooling and dehumidification including the principles of solid and liquid desiccant applications.Indeed,these systems perform well in hothumid climates.The result of a case study of the solid desiccant cooling system combined with solar energy for the desiccant wheel regeneration has been presented in the last chapter in this paper to show the capability of these systems once well applied in a hot-humid climate.展开更多
Characteristics of 13x molecular sieve, silica gel and DH 5 and DH 7 prepared by authors, were investigated for the solid desiccant cooling system. The adsorption isotherms of DH 5 and DH 7 were experimentally det...Characteristics of 13x molecular sieve, silica gel and DH 5 and DH 7 prepared by authors, were investigated for the solid desiccant cooling system. The adsorption isotherms of DH 5 and DH 7 were experimentally determined. The performance parameters of adsorption capacity, air humidity, regeneration temperature and cooling volume were tested and discussed in detail. The results show that the properties of new adsorbents DH 5 and DH 7 on desiccant cooling are much better than those of common desiccants. The maximum adsorption volumes of water on DH 5 and DH 7 are 0.72?kg/kg and 0.73 ?kg/kg, respectively. The desiccant cooling volumes of DH 7and DH 5 are 2.2 and 1.3 times larger than those of silica gel and 13x(molecular sieve), respectively, after regeneration at 100?℃. The cooling volume per mass unit of DH 5 is 1.9 times larger that of 13x.展开更多
This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy sys...This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy systems for buildings. The match of solar collector types and chiller types have been discussed and suggested.展开更多
文摘This paper reviews the principle and application of the thermally activated desiccant cooling systems with their capability to perform efficiently in hot-humid climates.The paper first introduces the continuous increase of thermal comfort required in building and their relation with the consumption of conventional energy sources.The importance of desiccant cooling technology and its applications has been introduced as well.The energy and environmental issues with the conventional energy supply and the demand with the environmental problems and conditions mainly related to indoor air quality have been also discussed in the second chapter of this paper.The third part of this paper deals with different techniques and systems applied for cooling and dehumidification including the principles of solid and liquid desiccant applications.Indeed,these systems perform well in hothumid climates.The result of a case study of the solid desiccant cooling system combined with solar energy for the desiccant wheel regeneration has been presented in the last chapter in this paper to show the capability of these systems once well applied in a hot-humid climate.
文摘Characteristics of 13x molecular sieve, silica gel and DH 5 and DH 7 prepared by authors, were investigated for the solid desiccant cooling system. The adsorption isotherms of DH 5 and DH 7 were experimentally determined. The performance parameters of adsorption capacity, air humidity, regeneration temperature and cooling volume were tested and discussed in detail. The results show that the properties of new adsorbents DH 5 and DH 7 on desiccant cooling are much better than those of common desiccants. The maximum adsorption volumes of water on DH 5 and DH 7 are 0.72?kg/kg and 0.73 ?kg/kg, respectively. The desiccant cooling volumes of DH 7and DH 5 are 2.2 and 1.3 times larger than those of silica gel and 13x(molecular sieve), respectively, after regeneration at 100?℃. The cooling volume per mass unit of DH 5 is 1.9 times larger that of 13x.
基金support of this research from Nation-al Key Technologies R&D Program ( No.2006BAA04B03) is gratefully acknowledged.
文摘This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy systems for buildings. The match of solar collector types and chiller types have been discussed and suggested.