期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
The Improved Design of Multi-channel Thin Gap Chamber Simulation Signal Source for the ATLAS Detector Upgrade
1
作者 胡坤 路后兵 +3 位作者 王旭 李锋 韩良 金革 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第8期35-39,共5页
We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can rand... We develop an improved design of thin gap chamber (TGC) simulation signal source. To further simulate the feature of TGC detector, a novel thought is proposed. The TGC source has 256 channels. Every channel can randomly output the signal in 25 ns. The design is based on true random number generator (TRNG). Considering the electrical connection between the TGC source and the developing trigger electronics, the GFZ connector is used. The experimental results show that the improved TGC simulation signal source can uniformly output the random signal in every channel. The output noise is less than 3 mVrms. 展开更多
关键词 TGC The Improved design of Multi-channel Thin Gap Chamber Simulation Signal source for the ATLAS Detector Upgrade ATLAS
下载PDF
Optimization of Selecting Air Conditioning Cold/Heat Sources with Grey Relation Analysis
2
作者 曹国庆 涂光备 《Transactions of Tianjin University》 EI CAS 2006年第3期229-234,共6页
Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categor... Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces. 展开更多
关键词 air conditioning cold/heat sources: design scheme: optimal selection: grey relation analysis evaluation factor
下载PDF
Design and validation on a multiple sound source fast-measurement system of near-field head-related transfer functions 被引量:1
3
作者 YU Guangzheng LIU Yu XIE Bosun 《Chinese Journal of Acoustics》 CSCD 2018年第2期219-240,共22页
Near-field head-related transfer functions (HRTFs) are essential to scientific re- searches of binaural hearing and practical applications of virtual auditory display. High ef- ficiency, accuracy and repeatability a... Near-field head-related transfer functions (HRTFs) are essential to scientific re- searches of binaural hearing and practical applications of virtual auditory display. High ef- ficiency, accuracy and repeatability are required in a near-field HRTF measurement. Hence, there is no reference which intents on solving the measuring difficulties of near-field HRTF for human subjects. In present work, an efficient near-field HRTF measurement system based on computer control is designed and implemented, and a fast calibration method for the system is proposed to first solve the measurement of near-field HRTF for human subjects. The efficiency of measurement is enhanced by a comprehensive design on the acoustic, electronic and mechanical parts of the system. And the accuracy and repeatability of the measurement are greatly im- proved by carefully calibrating the positions of sound source, subject and binaural microphones. This system is suitable for near-field HRTF measurement at various source distances within 1.0 m, for both human subject and artificial head. The time costs of HRTF measurement at a single sound source distance and full directions has been reduced to less than 20 minutes. The measurement results indicate that the accuracy of the system satisfies the actual requirements. The system is applicable to scientific research and can be used to establish an individualized near-field HRTF database for human subjects. 展开更多
关键词 design and validation on a multiple sound source fast-measurement system of near-field head-related transfer functions
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部