Kinesin-1 motor protein is a homodimer containing two identical motor domains connected by a common long coiledcoil stalk via two flexible neck linkers. The motor can step on a microtubule with a velocity of about 1 ...Kinesin-1 motor protein is a homodimer containing two identical motor domains connected by a common long coiledcoil stalk via two flexible neck linkers. The motor can step on a microtubule with a velocity of about 1 μm·s-1and an attachment duration of about 1 s under physiological conditions. The available experimental data indicate a tradeoff between velocity and attachment duration under various experimental conditions, such as variation of the solution temperature,variation of the strain between the two motor domains, and so on. However, the underlying mechanism of the tradeoff is unknown. Here, the mechanism is explained by a theoretical study of the dynamics of the motor under various experimental conditions, reproducing quantitatively the available experimental data and providing additional predictions. How the various experimental conditions lead to different decreasing rates of attachment duration versus velocity is also explained.展开更多
The Sonid Zuoqi ductile detachment zone is located at the southeastern margin of the Central Asian orogenic belt(CAOB),striking EW and dipping to the S.The major rock type of the Sonid Zuoqi ductile detachment zone is...The Sonid Zuoqi ductile detachment zone is located at the southeastern margin of the Central Asian orogenic belt(CAOB),striking EW and dipping to the S.The major rock type of the Sonid Zuoqi ductile detachment zone is mylonite derived from granite.The sequence of mylonite features is:(1)S and C foliations of mylonite,and(2)extensional crenulation cleavage(ecc)or C′and the kinematic vorticity(Wk)value changed from 0.70 to 0.95 and from 0.37 to 0.69,respectively;the strain type of the mylonites within the Sonid Zuoqi ductile detachment zone is compressional to planar strain.The strong deformation mylonite and Halatu plutons yielded a zircon U-Pb age of 244 Ma and a zircon(U-Th)/He age of 214 Ma,respectively.Based on the strain and kinematic vorticity analysis,together with the zircon U-Pb and zircon(U-Th)/He ages and the regional tectonic background,the study area experienced three stage evolution:tangential simpleshear(244 Ma),simple-shear-dominated general shear represented by upper crustal extension(224 Ma)and pure-shear-dominated general shear represented by the Halatu pluton doming(214 Ma),which constrained the early Mesozoic NE-SW crustal extension at the southeastern margin of the CAOB.This NE-SW extension probably originated from the postorogenic extensional collapse of the CAOB,subsequent exhumation being controlled by the far afield effects of the closure of the Mongol-Okhotsk belt.展开更多
On J-TEXT,the temporal evolution of heat flux distribution on the high-field side(HFS)divertor plate has been measured by an infrared(IR)camera during the plasma operation with an island divertor configuration.In expe...On J-TEXT,the temporal evolution of heat flux distribution on the high-field side(HFS)divertor plate has been measured by an infrared(IR)camera during the plasma operation with an island divertor configuration.In experiments,the island divertor configuration is an edge magnetic island chain structure surrounded by stochastic layers,which can be induced by resonant magnetic perturbations(RMPs).The experimental results show that the heat flux distribution on the HFS target plate depends significantly on the edge magnetic topology.Furthermore,the impact of hydrogen fueling using supersonic molecular beam injection(SMBI)on the divertor heat flux distributions is studied on J-TEXT with an island divertor configuration.It has been observed that power detachment can be achieved when the radiation front approaches the last closed flux surface(LCFS)after each SMBI pulse.This result may provide a method of access for divertor detachment on a fusion device with a three-dimensional(3D)boundary magnetic structure.展开更多
Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute...Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute extreme ultraviolet(AXUV)photodiodes have been used to quantify the radiated power.This article introduces the latest improvement of the bolometer diagnostic system on EAST.It also details the successful design and installation of new divertor AXUV cameras,which are dedicated to the investigation of divertor physics.The shielding components of the bolometer detector have been refined,and the article provides a detailed exposition of the double shielding structures that have been verified as effective in microwave shielding.Additionally,the changes in the radiated power distribution in the divertor region during the plasma detachment process are measured using the divertor AXUV camera.Finally,the radiated power measured by the AXUV detector and metal foil resistive bolometer are compared,and different detector performances are presented.展开更多
AIM:To analyze if a relationship between levels ofinflammatory serum biomarkers and severity of primaryproliferative vitreoretinopathy(PVR)exists.METHODS:A retrospective case-control study.Thehealthy adult patients wi...AIM:To analyze if a relationship between levels ofinflammatory serum biomarkers and severity of primaryproliferative vitreoretinopathy(PVR)exists.METHODS:A retrospective case-control study.Thehealthy adult patients with rhegmatogenous retinaldetachment and primary PVR were included in the PVRgroup.For the control group,healthy adults who underwentcataract surgery were included.The grade of PVR wasclassified according to the Retinal Society TerminologyCommittee.Blood samples were obtained before surgery,and processed in MYTHIC 18.Measures of interest wereneutrophil-to-lymphocyte ratio(NLR),platelet-to-lymphocyteratio(PLR),and lymphocyte-to-monocyte ratio(LMR),thetime between the decrease in visual acuity and surgery,PVRgrade,type of surgery,final best corrected visual acuity,andrate of re-detachment.RESULTS:Totally 240 patients were included,120 ineach group,79(65.8%)and 56(46.7%)were male in thePVR and control group,respectively.PVR A had greaterlevels of monocytes(0.28±0.18 vs 0.12±0.32,P=0.002),neutrophils(4.59±1.51 vs 3.92±1.27,P=0.006),and LMR(9.32±4.42 vs 7.43±3.90,P=0.01).PVR B had a greatermonocyte count(0.30±0.13 vs 0.12±0.32,P=0.001),andPVR C demonstrated higher levels in monocytes(0.27±0.12vs 0.12±0.32,P=0.004),neutrophils(4.39±1.13 vs3.92±1.27,P=0.004),and LMR(9.63±3.24 vs 7.43±3.90,P=0.002)compared to control,respectively.An LMR cut-offvalue of 9.38 predicted PVR with a sensibility of 54.2%andspecificity of 77.5%and NLR cut-off of 1.70 predicted PVRwith a sensibility of 62%and specificity of 54.2%.CONCLUSION:Patients with primary PVR demonstrategreater neutrophil,monocyte,and LMR levels than thecontrol group.Cut-off values obtained from ratios could beuseful in a clinical setting when no posterior view of thefundus is possible due to media opacity.展开更多
Achieving the detachment of divertor can help to alleviate excessive heat load and sputtering problems on the target plates,thereby extending the lifetime of divertor components for fusion devices.In order to provide ...Achieving the detachment of divertor can help to alleviate excessive heat load and sputtering problems on the target plates,thereby extending the lifetime of divertor components for fusion devices.In order to provide a fast but relatively reliable prediction of plasma parameters along the flux tube for future device design,a one-dimensional(1D)modeling code for the operating point of impurity seeded detached divertor is developed based on Python language,which is a fluid model based on previous work(Plasma Phys.Control.Fusion 58045013(2016)).The experimental observation of the onset of divertor detachment by neon(Ne)and argon(Ar)seeding in EAST is well reproduced by using the 1D modeling code.The comparison between the 1D modeling and two-dimensional(2D)simulation by the SOLPS-ITER code for CFETR detachment operation with Ne and Ar seeding also shows that they are in good agreement.We also predict the radiative power loss and corresponding impurity concentration requirement for achieving divertor detachment via different impurity seeding under high heating power conditions in EAST and CFETR phase II by using the 1D model.Based on the predictions,the optimized parameter space for divertor detachment operation on EAST and CFETR is also determined.Such a simple but reliable 1D model can provide a reasonable parameter input for a detailed and accurate analysis by 2D or three-dimensional(3D)modeling tools through rapid parameter scanning.展开更多
AIM:To evaluate the efficacy and safety of perfluoro-n-octane(PFO)for ophthalmic surgery versus F-Octane as an intraoperative tamponade in pars plana vitrectomy(PPV)in management of retinal detachment.METHODS:This mul...AIM:To evaluate the efficacy and safety of perfluoro-n-octane(PFO)for ophthalmic surgery versus F-Octane as an intraoperative tamponade in pars plana vitrectomy(PPV)in management of retinal detachment.METHODS:This multicenter,prospective,randomized,double-masked,parallel-controlled,non-inferiority trial was conducted in three ophthalmology clinical centers in China.Patients with retinal detachment,who were eligible for PPV were consecutively enrolled.Participants were assigned to PFO for ophthalmic surgery or F-Octane for intraocular tamponade in a 1:1 ratio.Best-corrected visual acuity(BCVA),intraocular pressure(IOP)measurement,and dilated fundus examination were performed preoperatively and at 1,7±1,28±3d postoperatively.The primary outcome was complete retinal reattachment rate at postoperative day one.The non-inferiority margin was set at 9.8%.The secondary outcomes included intraoperative retinal reattachment rate,and mean changes in IOP and BCVA from baseline to 1,7±1,28±3d postoperatively,respectively.Safety analyses were presented for all randomly assigned participates in this study.RESULTS:Totally 124 eligible patients completed the study between Mar.14,2016 and Jun.7,2017.Sixty of them were randomly assigned to the PFO for ophthalmic surgery group,and 64 were assigned to the F-Octane group.Baseline characteristics were comparable between the two groups.Both groups achieved 100%retinal reattachment at postoperative day one(difference 0,95%CI:-6.21%to 5.75%,P=1).The pre-defined noninferiority criterion was met.No significant difference was observed in intraoperative retinal reattachment rate(difference 1.77%,P=0.61),mean changes in IOP(difference 0.36,-0.09,2.22 mm Hg at 1,7±1,28±3d postoperatively,with all P>0.05)and BCVA(difference 0.04,-0.02,0.06 logMAR at 1,7±1,28±3d postoperatively,all P>0.05)between the two groups.No apparent adverse events related to the utilization of PFO were reported.CONCLUSION:In patients with retinal detachment undergoing PPV,PFO for ophthalmic surgery is non-inferior to F-Octane as an intraocular tamponade,and both are safe and well-tolerated.展开更多
AIM:To assess the utility and efficiency of endoscopyassisted vitrectomy(EAV)for the treatment of corneal opacity in severe ocular trauma.METHODS:Patients who underwent fundus examination using a preoperative slit lam...AIM:To assess the utility and efficiency of endoscopyassisted vitrectomy(EAV)for the treatment of corneal opacity in severe ocular trauma.METHODS:Patients who underwent fundus examination using a preoperative slit lamp and intraoperative endoscopy,followed by EAV and additional surgery were retrospectively recruited.Silicone oil removal and penetrating keratoplasty were used in selected eyes at postoperative follow-ups.Outcome measurements included the best corrected visual acuity(BCVA),intraocular pressure(IOP),findings of endoscopic fundus examination,and postoperative complications.RESULTS:Twenty-one eyes with severe ocular trauma and corneal opacity were followed up for 24-36mo.Retinal detachment(RD)and vitreous haemorrhage(VH)were identified in 16 eyes(76.2%),RD only in four eyes(19.0%),and VH combined with intraocular foreign body in one eye(4.8%).All eyes underwent at least three surgeries.Stage-Ⅰ surgeries involved wound closure(100%),lens extraction(76.2%),and anterior vitrectomy(14.3%).Stage-Ⅱ surgeries involved scleral buckling(28.6%),membrane peeling(47.6%),retinal laser photocoagulation(100%)and silicone oil tamponade(100%)using EAV.Stage-Ⅲ surgeries were conducted using endoscopy including silicone oil removal(52.4%),retinal laser photocoagulation(52.4%)and penetrating keratoplasty(28.6%).Nearly all eyes showed improvements in BCVA and IOP.Although there were no severe complications,glaucoma was noted in one eye,chronic hypotony in another eye,and band keratopathy in three eyes.CONCLUSION:EAV is an effective adjunct for restoring ocular anatomical structures and visual function in the case of corneal opacity after severe ocular trauma.展开更多
AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.MET...AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.展开更多
●AIM:To evaluate the efficacy of pneumatic retinopexy(PR)in patients undergoing PR as primary treatment for rhegmatogenous retinal detachment(RRD)and analyze the factors associated with success and failure in the stu...●AIM:To evaluate the efficacy of pneumatic retinopexy(PR)in patients undergoing PR as primary treatment for rhegmatogenous retinal detachment(RRD)and analyze the factors associated with success and failure in the studied population.●METHODS:A retrospective chart review was done of patients with RRD treated with PR as primary management method treated at New York Eye and Ear Infirmary of Mount Sinai between January 2017 and December 2021.Primary outcome measured success or failure of PR.Secondary outcome measured best corrected visual acuity(BCVA)after PR.A separate risk analysis was done to identify and stratify risks associated with success and failure of PR.●RESULTS:A total of 179 eyes from 179 patients were included for final analysis.The 83 patients(46.37%)achieved anatomical reattachment of the retina after primary PR with no need for additional surgery.The 96 patients(53.63%)had a failed primary PR and required a PPV and 6 of them required pars plana vitrectomy(PPV)with scleral buckle(SB).In total,19 cases(10.61%)were done as temporizing pneumatics,18(94.74%)underwent PPV,and 1(5.26%)did not require further intervention.The visual acuities at postoperative month 1(POM1)for patients who underwent primary PR successfully and for those that underwent PPV after,were 0.58(20/80)and 1.03(20/200)respectively.Patients who met Pneumatic Retinopexy Versus Vitrectomy for the Management of Primary Rhegmatogenous Retinal Detachment Outcomes Randomized Trial(PIVOT)criteria had a statistically significant decreased risk of primary PR failing(hazard ratio 0.29,P=0.00).Majority of missed or new breaks were found superotemporally.●CONCLUSION:PR is a good treatment option for treating RRDs in patients that meet PIVOT criteria and can be conducted as a temporizing measure.PIVOT criteria and fovea on status decrease the risk of PR failure.展开更多
●AIM:To evaluate the effectiveness and safety of scleral buckling for the treatment of rhegmatogenous retinal detachment(RRD)using a novel foldable capsular buckle(FCB).●METHODS:This was a series of case observation...●AIM:To evaluate the effectiveness and safety of scleral buckling for the treatment of rhegmatogenous retinal detachment(RRD)using a novel foldable capsular buckle(FCB).●METHODS:This was a series of case observation studies.Eighteen patients(18 eyes)who visited our ophthalmology department between August 2020 and August 2022 and were treated for RRD with scleral buckling using FCB were included.The procedure was similar to conventional scleral buckling,while a balloon-like FCB was placed onto the retinal break with balanced salt solution filling for a broad,external indentation instead of the silicone buckle.The retinal reattachment rate,best corrected visual acuity(BCVA),intraocular pressure(IOP),refractive dioptre and astigmatism degree,and complications were evaluated and recorded.●RESULTS:There were 7 males and 11 females aged 19-58y.The average time course of RRD was 12d,ranging from 7-20d.The retinal break was located in the superior quadrants in 8 eyes and in the inferior quadrants in 10 eyes,with macula-off detachments in 12 eyes.The patients were followed-up for at least 6mo.The final retinal reattachment rate was 100%.The BCVA was significantly improved compared with the baseline(P<0.05).There was no significant change in refractive dioptre or astigmatism degree at each follow-up(all P>0.05).Three patients had transiently high IOPs within one week after surgery.Mild diplopia occurred in 5 patients after surgery and then disappeared after the balloon fluid was removed.●CONCLUSION:The success rate of FCB scleral buckling for RRD is satisfactory.This procedure can be expected to be applied in new,uncomplicated cases of RRD.展开更多
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv...AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes.展开更多
BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innova...BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innovatively used ultrasound guidance combined with digital subtraction angiography(DSA)to completely remove the occluder,accumulating some experience.CASE SUMMARY The patient underwent left atrial appendage occlusion surgery in our hospital due to atrial fibrillation.After the surgery,the occluder fell off and became free in the left ventricle,which is very dangerous.We innovatively used ultrasound guidance,combined with DSA,and interventional surgery to successfully capture the free occluder using a catcher,completely remove it,and then re implant a new left atrial appendage occluder.After the surgery,the patient recovered very well.CONCLUSION The size selection of the occluder is slightly conservative,and the shape of the left atrial appendage opening is irregular.展开更多
In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable st...In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable stent(BRS)during percutaneous coronary intervention(PCI)in a male patient.The unloading of BRS was detected via angiography and intravascular ultrasound(IVUS)imaging of the left coronary artery and left anterior descending artery.Although this case is interesting,the authors’report lacked crucial details.Specifically,insufficient information about the type of BRS used,potential causes of BRS unloading,or whether optical coherence tomography(OCT)imaging for coronary arteries was performed before,during,or after PCI.The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS.In addition,despite detecting myocardial bridging during the PCI,the authors did not provide any details regarding this variation.Here we discuss the various types of BRS,the importance of OCT in PCI,and the clinical relevance of myocardial bridging.展开更多
Sickle cell disease(SCD)is a widespread hemoglobinopathy that results in significant patient morbidity and mortality.Vascular occlusion can cause acute pain,acute chest syndrome,and avascular necrosis,while hemolysis ...Sickle cell disease(SCD)is a widespread hemoglobinopathy that results in significant patient morbidity and mortality.Vascular occlusion can cause acute pain,acute chest syndrome,and avascular necrosis,while hemolysis and endothelial disruption can cause ischemic stroke,leg ulcers,pulmonary hypertension,and priapism.All ocular and orbital structures can be affected by SCD ischemic events,including orbital bone infarction,ischemic optic neuropathy,retinal artery occlusion,hyphema,secondary glaucoma,sickle cell maculopathy,and sickle cell retinopathy.Proliferative sickle cell retinopathy(PSR)is the most common cause of vision loss.Untreated PSR can lead to macular ischemia,vitreous hemorrhage,and tractional retinal detachment.Ophthalmic screening exams and multimodal imaging can lead to earlier detection of sickle cell retinopathy and improved patient outcomes.SCD patients undergoing vitreoretinal surgery may require coordination of care with hematologists to avoid ischemic complications.While hydroxyurea was the only United States Food and Drug Administration approved treatment for several decades,patients with SCD now have several more treatment options.Despite the United States screening all infants for SCD,there can be delays in diagnosis and treatment.This review article aims to provide an overview of sickle disease for the ophthalmologist,and to discuss emerging treatment options and current management of SCD ocular complications.展开更多
The wavelength dependence of photoelectron angular distributions (PADs) of two-photon detachment of Cu^- has been directly studied by using the photoelectron map imaging. Results show that for the laser field intens...The wavelength dependence of photoelectron angular distributions (PADs) of two-photon detachment of Cu^- has been directly studied by using the photoelectron map imaging. Results show that for the laser field intensity of 6.0×10^10W/cm^2, PADs exhibit dramatic change with the external field wavelength. Comparison between the experimental observation and the lowest-order perturbation theory prediction indicates that the pattern of PADs can be explained by the interference of the s and d partial waves in the final state. Relative contri- butions of s and d partial waves in the two-photon detachment at different laser wavelengths are obtained.展开更多
文摘Kinesin-1 motor protein is a homodimer containing two identical motor domains connected by a common long coiledcoil stalk via two flexible neck linkers. The motor can step on a microtubule with a velocity of about 1 μm·s-1and an attachment duration of about 1 s under physiological conditions. The available experimental data indicate a tradeoff between velocity and attachment duration under various experimental conditions, such as variation of the solution temperature,variation of the strain between the two motor domains, and so on. However, the underlying mechanism of the tradeoff is unknown. Here, the mechanism is explained by a theoretical study of the dynamics of the motor under various experimental conditions, reproducing quantitatively the available experimental data and providing additional predictions. How the various experimental conditions lead to different decreasing rates of attachment duration versus velocity is also explained.
基金supported by the National Natural Science Foundation of China(Grant No.41662014)。
文摘The Sonid Zuoqi ductile detachment zone is located at the southeastern margin of the Central Asian orogenic belt(CAOB),striking EW and dipping to the S.The major rock type of the Sonid Zuoqi ductile detachment zone is mylonite derived from granite.The sequence of mylonite features is:(1)S and C foliations of mylonite,and(2)extensional crenulation cleavage(ecc)or C′and the kinematic vorticity(Wk)value changed from 0.70 to 0.95 and from 0.37 to 0.69,respectively;the strain type of the mylonites within the Sonid Zuoqi ductile detachment zone is compressional to planar strain.The strong deformation mylonite and Halatu plutons yielded a zircon U-Pb age of 244 Ma and a zircon(U-Th)/He age of 214 Ma,respectively.Based on the strain and kinematic vorticity analysis,together with the zircon U-Pb and zircon(U-Th)/He ages and the regional tectonic background,the study area experienced three stage evolution:tangential simpleshear(244 Ma),simple-shear-dominated general shear represented by upper crustal extension(224 Ma)and pure-shear-dominated general shear represented by the Halatu pluton doming(214 Ma),which constrained the early Mesozoic NE-SW crustal extension at the southeastern margin of the CAOB.This NE-SW extension probably originated from the postorogenic extensional collapse of the CAOB,subsequent exhumation being controlled by the far afield effects of the closure of the Mongol-Okhotsk belt.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China(No.2018YFE0309103)National Natural Science Foundation of China(Nos.12305243 and 51821005)。
文摘On J-TEXT,the temporal evolution of heat flux distribution on the high-field side(HFS)divertor plate has been measured by an infrared(IR)camera during the plasma operation with an island divertor configuration.In experiments,the island divertor configuration is an edge magnetic island chain structure surrounded by stochastic layers,which can be induced by resonant magnetic perturbations(RMPs).The experimental results show that the heat flux distribution on the HFS target plate depends significantly on the edge magnetic topology.Furthermore,the impact of hydrogen fueling using supersonic molecular beam injection(SMBI)on the divertor heat flux distributions is studied on J-TEXT with an island divertor configuration.It has been observed that power detachment can be achieved when the radiation front approaches the last closed flux surface(LCFS)after each SMBI pulse.This result may provide a method of access for divertor detachment on a fusion device with a three-dimensional(3D)boundary magnetic structure.
基金supported by the National MCF Energy R&D Program of China(Nos.2022YFE03040003 and 2019YFE03010003).
文摘Measurements of the total radiated power and its spatial distribution are crucial for fusion research.On the experimental advanced superconducting tokamak(EAST),both the metal foil resistive bolometer and the absolute extreme ultraviolet(AXUV)photodiodes have been used to quantify the radiated power.This article introduces the latest improvement of the bolometer diagnostic system on EAST.It also details the successful design and installation of new divertor AXUV cameras,which are dedicated to the investigation of divertor physics.The shielding components of the bolometer detector have been refined,and the article provides a detailed exposition of the double shielding structures that have been verified as effective in microwave shielding.Additionally,the changes in the radiated power distribution in the divertor region during the plasma detachment process are measured using the divertor AXUV camera.Finally,the radiated power measured by the AXUV detector and metal foil resistive bolometer are compared,and different detector performances are presented.
文摘AIM:To analyze if a relationship between levels ofinflammatory serum biomarkers and severity of primaryproliferative vitreoretinopathy(PVR)exists.METHODS:A retrospective case-control study.Thehealthy adult patients with rhegmatogenous retinaldetachment and primary PVR were included in the PVRgroup.For the control group,healthy adults who underwentcataract surgery were included.The grade of PVR wasclassified according to the Retinal Society TerminologyCommittee.Blood samples were obtained before surgery,and processed in MYTHIC 18.Measures of interest wereneutrophil-to-lymphocyte ratio(NLR),platelet-to-lymphocyteratio(PLR),and lymphocyte-to-monocyte ratio(LMR),thetime between the decrease in visual acuity and surgery,PVRgrade,type of surgery,final best corrected visual acuity,andrate of re-detachment.RESULTS:Totally 240 patients were included,120 ineach group,79(65.8%)and 56(46.7%)were male in thePVR and control group,respectively.PVR A had greaterlevels of monocytes(0.28±0.18 vs 0.12±0.32,P=0.002),neutrophils(4.59±1.51 vs 3.92±1.27,P=0.006),and LMR(9.32±4.42 vs 7.43±3.90,P=0.01).PVR B had a greatermonocyte count(0.30±0.13 vs 0.12±0.32,P=0.001),andPVR C demonstrated higher levels in monocytes(0.27±0.12vs 0.12±0.32,P=0.004),neutrophils(4.39±1.13 vs3.92±1.27,P=0.004),and LMR(9.63±3.24 vs 7.43±3.90,P=0.002)compared to control,respectively.An LMR cut-offvalue of 9.38 predicted PVR with a sensibility of 54.2%andspecificity of 77.5%and NLR cut-off of 1.70 predicted PVRwith a sensibility of 62%and specificity of 54.2%.CONCLUSION:Patients with primary PVR demonstrategreater neutrophil,monocyte,and LMR levels than thecontrol group.Cut-off values obtained from ratios could beuseful in a clinical setting when no posterior view of thefundus is possible due to media opacity.
基金Project supported by the National Key Research and Development Program of China (Grant No.2022YFE03030001)the National Natural Science Foundation of China (Grant No.12075283)。
文摘Achieving the detachment of divertor can help to alleviate excessive heat load and sputtering problems on the target plates,thereby extending the lifetime of divertor components for fusion devices.In order to provide a fast but relatively reliable prediction of plasma parameters along the flux tube for future device design,a one-dimensional(1D)modeling code for the operating point of impurity seeded detached divertor is developed based on Python language,which is a fluid model based on previous work(Plasma Phys.Control.Fusion 58045013(2016)).The experimental observation of the onset of divertor detachment by neon(Ne)and argon(Ar)seeding in EAST is well reproduced by using the 1D modeling code.The comparison between the 1D modeling and two-dimensional(2D)simulation by the SOLPS-ITER code for CFETR detachment operation with Ne and Ar seeding also shows that they are in good agreement.We also predict the radiative power loss and corresponding impurity concentration requirement for achieving divertor detachment via different impurity seeding under high heating power conditions in EAST and CFETR phase II by using the 1D model.Based on the predictions,the optimized parameter space for divertor detachment operation on EAST and CFETR is also determined.Such a simple but reliable 1D model can provide a reasonable parameter input for a detailed and accurate analysis by 2D or three-dimensional(3D)modeling tools through rapid parameter scanning.
基金Supported by the Program of Shanghai Academic/Technology Research Leader(No.21XD1402700)the Clinical Research Plan of Shenkang Hospital Development Center of Shanghai(No.SHDC2022CRD001).
文摘AIM:To evaluate the efficacy and safety of perfluoro-n-octane(PFO)for ophthalmic surgery versus F-Octane as an intraoperative tamponade in pars plana vitrectomy(PPV)in management of retinal detachment.METHODS:This multicenter,prospective,randomized,double-masked,parallel-controlled,non-inferiority trial was conducted in three ophthalmology clinical centers in China.Patients with retinal detachment,who were eligible for PPV were consecutively enrolled.Participants were assigned to PFO for ophthalmic surgery or F-Octane for intraocular tamponade in a 1:1 ratio.Best-corrected visual acuity(BCVA),intraocular pressure(IOP)measurement,and dilated fundus examination were performed preoperatively and at 1,7±1,28±3d postoperatively.The primary outcome was complete retinal reattachment rate at postoperative day one.The non-inferiority margin was set at 9.8%.The secondary outcomes included intraoperative retinal reattachment rate,and mean changes in IOP and BCVA from baseline to 1,7±1,28±3d postoperatively,respectively.Safety analyses were presented for all randomly assigned participates in this study.RESULTS:Totally 124 eligible patients completed the study between Mar.14,2016 and Jun.7,2017.Sixty of them were randomly assigned to the PFO for ophthalmic surgery group,and 64 were assigned to the F-Octane group.Baseline characteristics were comparable between the two groups.Both groups achieved 100%retinal reattachment at postoperative day one(difference 0,95%CI:-6.21%to 5.75%,P=1).The pre-defined noninferiority criterion was met.No significant difference was observed in intraoperative retinal reattachment rate(difference 1.77%,P=0.61),mean changes in IOP(difference 0.36,-0.09,2.22 mm Hg at 1,7±1,28±3d postoperatively,with all P>0.05)and BCVA(difference 0.04,-0.02,0.06 logMAR at 1,7±1,28±3d postoperatively,all P>0.05)between the two groups.No apparent adverse events related to the utilization of PFO were reported.CONCLUSION:In patients with retinal detachment undergoing PPV,PFO for ophthalmic surgery is non-inferior to F-Octane as an intraocular tamponade,and both are safe and well-tolerated.
基金Supported by the Guangdong Province Natural Science Foundation(No.2019A1515011732)Guangzhou Science and Technology Foundation of Guangdong Province(No.202002030413)Science and Technology Project of General Hospital of Southern Theater Command of PLA(No.2023NZB010).
文摘AIM:To assess the utility and efficiency of endoscopyassisted vitrectomy(EAV)for the treatment of corneal opacity in severe ocular trauma.METHODS:Patients who underwent fundus examination using a preoperative slit lamp and intraoperative endoscopy,followed by EAV and additional surgery were retrospectively recruited.Silicone oil removal and penetrating keratoplasty were used in selected eyes at postoperative follow-ups.Outcome measurements included the best corrected visual acuity(BCVA),intraocular pressure(IOP),findings of endoscopic fundus examination,and postoperative complications.RESULTS:Twenty-one eyes with severe ocular trauma and corneal opacity were followed up for 24-36mo.Retinal detachment(RD)and vitreous haemorrhage(VH)were identified in 16 eyes(76.2%),RD only in four eyes(19.0%),and VH combined with intraocular foreign body in one eye(4.8%).All eyes underwent at least three surgeries.Stage-Ⅰ surgeries involved wound closure(100%),lens extraction(76.2%),and anterior vitrectomy(14.3%).Stage-Ⅱ surgeries involved scleral buckling(28.6%),membrane peeling(47.6%),retinal laser photocoagulation(100%)and silicone oil tamponade(100%)using EAV.Stage-Ⅲ surgeries were conducted using endoscopy including silicone oil removal(52.4%),retinal laser photocoagulation(52.4%)and penetrating keratoplasty(28.6%).Nearly all eyes showed improvements in BCVA and IOP.Although there were no severe complications,glaucoma was noted in one eye,chronic hypotony in another eye,and band keratopathy in three eyes.CONCLUSION:EAV is an effective adjunct for restoring ocular anatomical structures and visual function in the case of corneal opacity after severe ocular trauma.
基金Supported by National Natural Science Foundation of China(No.81700884)Scientific Research Foundation of National Health and Health Commission(No.WKJ-ZJ-2037)+1 种基金Zhejiang Public Welfare Technology Application Project(No.LGF21H120005)Science and Technology Project of Wenzhou(No.Y20190649).
文摘AIM:To evaluate scleral buckling(SB)surgery using a noncontact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil(SO)-filled eyes.METHODS:Totally 9 patients(9 eyes)with retinal detachment in SO-filled eyes were retrospectively analyzed.All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination.SO was removed at an appropriate time based on recovery.The patients were followed up for at least 3mo after SO removal.Retinal reattachment,complications,visual acuity and intraocular pressure(IOP)before and after surgery were observed.RESULTS:Patients were followed up for a mean of 8.22mo(3-22mo)after SO removal.All patients had retinal reattachment.At the final follow-up,visual acuity showed improvement for 8 patients,and no change for 1 patient.The IOP was high in 3 patients before surgery,but it stabilized after treatment;it was not affected in the other patients.None of the patients had infections,hemorrhage,anterior ischemia,or any other complication.CONCLUSION:This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.
文摘●AIM:To evaluate the efficacy of pneumatic retinopexy(PR)in patients undergoing PR as primary treatment for rhegmatogenous retinal detachment(RRD)and analyze the factors associated with success and failure in the studied population.●METHODS:A retrospective chart review was done of patients with RRD treated with PR as primary management method treated at New York Eye and Ear Infirmary of Mount Sinai between January 2017 and December 2021.Primary outcome measured success or failure of PR.Secondary outcome measured best corrected visual acuity(BCVA)after PR.A separate risk analysis was done to identify and stratify risks associated with success and failure of PR.●RESULTS:A total of 179 eyes from 179 patients were included for final analysis.The 83 patients(46.37%)achieved anatomical reattachment of the retina after primary PR with no need for additional surgery.The 96 patients(53.63%)had a failed primary PR and required a PPV and 6 of them required pars plana vitrectomy(PPV)with scleral buckle(SB).In total,19 cases(10.61%)were done as temporizing pneumatics,18(94.74%)underwent PPV,and 1(5.26%)did not require further intervention.The visual acuities at postoperative month 1(POM1)for patients who underwent primary PR successfully and for those that underwent PPV after,were 0.58(20/80)and 1.03(20/200)respectively.Patients who met Pneumatic Retinopexy Versus Vitrectomy for the Management of Primary Rhegmatogenous Retinal Detachment Outcomes Randomized Trial(PIVOT)criteria had a statistically significant decreased risk of primary PR failing(hazard ratio 0.29,P=0.00).Majority of missed or new breaks were found superotemporally.●CONCLUSION:PR is a good treatment option for treating RRDs in patients that meet PIVOT criteria and can be conducted as a temporizing measure.PIVOT criteria and fovea on status decrease the risk of PR failure.
基金Supported by Xuzhou Health Outstanding Talents Project(No.XWJC001)Critical Special Project for Social Development of Xuzhou(No.KC21153)+1 种基金Science and Technology Innovation Project of Xuzhou Municipal Health Commission(No.XWKYHT20230039)Applied Basic Research Project of Xuzhou(No.KC23016).
文摘●AIM:To evaluate the effectiveness and safety of scleral buckling for the treatment of rhegmatogenous retinal detachment(RRD)using a novel foldable capsular buckle(FCB).●METHODS:This was a series of case observation studies.Eighteen patients(18 eyes)who visited our ophthalmology department between August 2020 and August 2022 and were treated for RRD with scleral buckling using FCB were included.The procedure was similar to conventional scleral buckling,while a balloon-like FCB was placed onto the retinal break with balanced salt solution filling for a broad,external indentation instead of the silicone buckle.The retinal reattachment rate,best corrected visual acuity(BCVA),intraocular pressure(IOP),refractive dioptre and astigmatism degree,and complications were evaluated and recorded.●RESULTS:There were 7 males and 11 females aged 19-58y.The average time course of RRD was 12d,ranging from 7-20d.The retinal break was located in the superior quadrants in 8 eyes and in the inferior quadrants in 10 eyes,with macula-off detachments in 12 eyes.The patients were followed-up for at least 6mo.The final retinal reattachment rate was 100%.The BCVA was significantly improved compared with the baseline(P<0.05).There was no significant change in refractive dioptre or astigmatism degree at each follow-up(all P>0.05).Three patients had transiently high IOPs within one week after surgery.Mild diplopia occurred in 5 patients after surgery and then disappeared after the balloon fluid was removed.●CONCLUSION:The success rate of FCB scleral buckling for RRD is satisfactory.This procedure can be expected to be applied in new,uncomplicated cases of RRD.
基金Supported by the Fundamental Research Funds of the State Key Laboratory of Ophthalmology(No.303060202400201203).
文摘AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes.
文摘BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innovatively used ultrasound guidance combined with digital subtraction angiography(DSA)to completely remove the occluder,accumulating some experience.CASE SUMMARY The patient underwent left atrial appendage occlusion surgery in our hospital due to atrial fibrillation.After the surgery,the occluder fell off and became free in the left ventricle,which is very dangerous.We innovatively used ultrasound guidance,combined with DSA,and interventional surgery to successfully capture the free occluder using a catcher,completely remove it,and then re implant a new left atrial appendage occluder.After the surgery,the patient recovered very well.CONCLUSION The size selection of the occluder is slightly conservative,and the shape of the left atrial appendage opening is irregular.
文摘In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable stent(BRS)during percutaneous coronary intervention(PCI)in a male patient.The unloading of BRS was detected via angiography and intravascular ultrasound(IVUS)imaging of the left coronary artery and left anterior descending artery.Although this case is interesting,the authors’report lacked crucial details.Specifically,insufficient information about the type of BRS used,potential causes of BRS unloading,or whether optical coherence tomography(OCT)imaging for coronary arteries was performed before,during,or after PCI.The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS.In addition,despite detecting myocardial bridging during the PCI,the authors did not provide any details regarding this variation.Here we discuss the various types of BRS,the importance of OCT in PCI,and the clinical relevance of myocardial bridging.
文摘Sickle cell disease(SCD)is a widespread hemoglobinopathy that results in significant patient morbidity and mortality.Vascular occlusion can cause acute pain,acute chest syndrome,and avascular necrosis,while hemolysis and endothelial disruption can cause ischemic stroke,leg ulcers,pulmonary hypertension,and priapism.All ocular and orbital structures can be affected by SCD ischemic events,including orbital bone infarction,ischemic optic neuropathy,retinal artery occlusion,hyphema,secondary glaucoma,sickle cell maculopathy,and sickle cell retinopathy.Proliferative sickle cell retinopathy(PSR)is the most common cause of vision loss.Untreated PSR can lead to macular ischemia,vitreous hemorrhage,and tractional retinal detachment.Ophthalmic screening exams and multimodal imaging can lead to earlier detection of sickle cell retinopathy and improved patient outcomes.SCD patients undergoing vitreoretinal surgery may require coordination of care with hematologists to avoid ischemic complications.While hydroxyurea was the only United States Food and Drug Administration approved treatment for several decades,patients with SCD now have several more treatment options.Despite the United States screening all infants for SCD,there can be delays in diagnosis and treatment.This review article aims to provide an overview of sickle disease for the ophthalmologist,and to discuss emerging treatment options and current management of SCD ocular complications.
基金ACKNOWLEDGMENTS This work was supported by the National Natural Science Foundation of China (No.21073188).
文摘The wavelength dependence of photoelectron angular distributions (PADs) of two-photon detachment of Cu^- has been directly studied by using the photoelectron map imaging. Results show that for the laser field intensity of 6.0×10^10W/cm^2, PADs exhibit dramatic change with the external field wavelength. Comparison between the experimental observation and the lowest-order perturbation theory prediction indicates that the pattern of PADs can be explained by the interference of the s and d partial waves in the final state. Relative contri- butions of s and d partial waves in the two-photon detachment at different laser wavelengths are obtained.