Four types of seismic design details were tested using 11 transfer column specimens and one comparison specimen of RC under low cyclic reversed loading. Test results show that diagonal cracks control the failure patte...Four types of seismic design details were tested using 11 transfer column specimens and one comparison specimen of RC under low cyclic reversed loading. Test results show that diagonal cracks control the failure pattern and damage occurs mainly in the RC section with weak shear capacity in the transfer columns. There is a large difference in the bearing capacity and ductility of the transfer columns according to the test results, which indicates that the strengthening effect of diverse structural measures is quite different. The section ratio of I-section-encased steel and the axial compression ratio also have a great influence on the bearing capacity and ductility. Although the bearing capacity of transfer columns with additional longitudinal bars and additional X bars is relatively large, they have poor deformation capacity. Setting more stirrups along the columns is the best structural measure to enhance the seismic performance. The studs on the I-sectionencased steel by welding can help to complete the stress transfer between the steel and concrete, and avoid performance degradation of the two materials due to bonding failure.展开更多
Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in th...Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in the present work.Detailed design for pilot DWC was performed and five control structures,i.e.composition control(CC),temperature control(TC),composition-temperature control(CC-TC),temperature difference control(TDC),double temperature difference control(DTDC)were proposed to circumvent feed disturbance.Sensitivity analysis and singular value decomposition(SVD)were used as criterion to select the controlled temperature locations in TC,CC-TC,TDC and DTDC control loops.The steady simulation result demonstrates that 25.7% and 30.2% duty can be saved for condenser and reboiler by substituting conventional column sequence with DWC,respectively.As for control structure selection,TC and TDC perform better than other three control schemes with smaller maximum deviation and shorter settling time.展开更多
基金Supported by:National Natural Science Foundation of China under Grant No.51208175the Fundamental Research Funds for the Central Universities under Grant Nos.2015B17514 and 2016B20514
文摘Four types of seismic design details were tested using 11 transfer column specimens and one comparison specimen of RC under low cyclic reversed loading. Test results show that diagonal cracks control the failure pattern and damage occurs mainly in the RC section with weak shear capacity in the transfer columns. There is a large difference in the bearing capacity and ductility of the transfer columns according to the test results, which indicates that the strengthening effect of diverse structural measures is quite different. The section ratio of I-section-encased steel and the axial compression ratio also have a great influence on the bearing capacity and ductility. Although the bearing capacity of transfer columns with additional longitudinal bars and additional X bars is relatively large, they have poor deformation capacity. Setting more stirrups along the columns is the best structural measure to enhance the seismic performance. The studs on the I-sectionencased steel by welding can help to complete the stress transfer between the steel and concrete, and avoid performance degradation of the two materials due to bonding failure.
基金Supported by Open Research Project of State Key Laboratory of Chemical Engineering(Grant No.SKL-Ch E-16B06)
文摘Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in the present work.Detailed design for pilot DWC was performed and five control structures,i.e.composition control(CC),temperature control(TC),composition-temperature control(CC-TC),temperature difference control(TDC),double temperature difference control(DTDC)were proposed to circumvent feed disturbance.Sensitivity analysis and singular value decomposition(SVD)were used as criterion to select the controlled temperature locations in TC,CC-TC,TDC and DTDC control loops.The steady simulation result demonstrates that 25.7% and 30.2% duty can be saved for condenser and reboiler by substituting conventional column sequence with DWC,respectively.As for control structure selection,TC and TDC perform better than other three control schemes with smaller maximum deviation and shorter settling time.