期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping, transcranial Doppler sonography and computer tomography examinations
1
作者 Dongruo He Xiaoying Xu +1 位作者 Yinghui Zhang Guochao Han 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期379-381,共3页
BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderat... BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination. 展开更多
关键词 HIE comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping transcranial Doppler sonography and computer tomography examinations
下载PDF
Quantitative detection and comparison of sulfate glycosaminoglycans content in extracellular matrix of in vitro cultured epiphyseal, articular and rib chondrocytes
2
作者 陶凌晖 《外科研究与新技术》 2003年第2期97-97,共1页
Objective To establish a method for quantitative detection of the sulfate glycosaminoglycans ( GAG) content in extracellular matrix of in vitro cultured chondrocytes so as to evaluate the biological characteristics of... Objective To establish a method for quantitative detection of the sulfate glycosaminoglycans ( GAG) content in extracellular matrix of in vitro cultured chondrocytes so as to evaluate the biological characteristics of epiphyseal, articular and rib chondrocytes. Methods Sulfate GAG content in extracellular matrix of three chondrocytes was measured by the modified dimethylmethylene blue (DMB) method. The changes of the toluidine blue (TB) stain of chondrocytes were observed by light microscope. Results Primary chondrocytes had the highest content of sulfate GAG in the extracellular matrix, ie, epiphyseal chondrocytes reached ( 70. 12 ± 7. 72 )μg/cm2, articular chondrocytes (92.00 ± 10.15) μg/cm2 and rib chondrocytes (80.61 ± 11. 40) μg/cm2, respectively. On the third pasage chondrocytes, epiphyceal chondrocytes decreased to (53.27 ± 9. 50 ) μg/cm2, articular chondrocytes to (63.88 ± 11.92) μg/cm2 and rib chondrocytes to (58.94 ±8.21) μg/cm2, respectively. The change of TB in every passage 展开更多
关键词 in of Quantitative detection and comparison of sulfate glycosaminoglycans content in extracellular matrix of in vitro cultured epiphyseal
下载PDF
Comparison of optical detection system,PVDF detection system,and PVDF needle hydrophone for optoacoustic tomography 被引量:3
3
作者 M. D. Abolhassani M. Hejazi +1 位作者 A. Ahmadian A. Amjadi 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第10期593-596,共4页
Optoacoustic tomography (PAT) is a two-dimensional medical imaging method that has the advantage of optical contrast and resolution of ultrasonic waves. The detection systems with a high sensitivity can be used for ... Optoacoustic tomography (PAT) is a two-dimensional medical imaging method that has the advantage of optical contrast and resolution of ultrasonic waves. The detection systems with a high sensitivity can be used for detecting small tumors, located deeply in human tissues, such as the breast. In this study, the sensitivity of existing ultrasonic detection systems has been compared experimentally with that by using thermoelastic waves as a broadband ultrasonic source. For the comparison, an optical stress transducer (OST), a polyvinylidene difluoride (PVDF) sheet and a calibrated PVDF needle hydrophone were used. To ensure all of the detection systems interrogated by the same ultrasonic field, a small optical instrument that fixed the generating laser head was constructed. The sensitivity was evaluated by measuring signalto-noise ratios (SNRs) and noise equivalent pressures (NEPs). The PVDF system, with a 4-kPa NEP has a 22 dB better performance than the OST. The OST showed nearly the same sensitivity as the hydrophone for detecting ultrasound waves at a 1-cm distance in water. PVDF detection system provides a useful tool for imaging of soft tissues because of its high sensitivity and broad detection range. 展开更多
关键词 PVDF comparison of optical detection system PVDF detection system and PVDF needle hydrophone for optoacoustic tomography
原文传递
Detection of HBV DNA in Extrahepatic Tissue with PCR Comparison with Immunohistochemistry and in Situ Hybridization
4
《Chinese Medical Journal》 SCIE CAS CSCD 1994年第10期79-79,共1页
Formalin-fixed paraffin-embedded tissue,including gallbladder,kidney,spleen,adrenal gland,heart,testicle,pancreas,and liver from 18 autopsied cases with HBV infection were studied with nested polymerase chain reaction
关键词 PCR HBV Detection of HBV DNA in Extrahepatic Tissue with PCR comparison with Immunohistochemistry and in Situ Hybridization DNA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部