In this paper,a two-layer hierarchical structure of optimization and control for polypropylene grade transition was raised to overcome process uncertain disturbances that led to the large deviation between the open-lo...In this paper,a two-layer hierarchical structure of optimization and control for polypropylene grade transition was raised to overcome process uncertain disturbances that led to the large deviation between the open-loop reference trajectory and the actual process.In the upper layer,the variant time scale based control vector parametric methods(VTS-CVP) was used for dynamic optimization of transition reference trajectory,while nonlinear model predictive controller(NMPC) based on closed-loop subspace and piece-wise linear(SSARX-PWL) model in the lower layer was tracking to the reference trajectory from the upper layer for overcoming high-frequency disturbances.Besides,mechanism about trajectory deviation detection and optimal trajectory updating online were introduced to ensure a smooth transition for the entire process.The proposed method was validated with the real data from an industrial double-loop propylene polymerization reaction process with developed dynamic mechanism mathematical model.展开更多
In the Chang'e-3 mission, the Active Particle-induced X-ray Spectrometer(APXS) on the Yutu rover is used to analyze the chemical composition of lunar soil and rock samples. APXS data are only valid are only if the ...In the Chang'e-3 mission, the Active Particle-induced X-ray Spectrometer(APXS) on the Yutu rover is used to analyze the chemical composition of lunar soil and rock samples. APXS data are only valid are only if the sensor head gets close to the target and integration time lasts long enough. Therefore, working distance and integration time are the dominant factors that affect APXS results. This study confirms the ability of APXS to detect elements and investigates the effects of distance and time on the measurements. We make use of a backup APXS instrument to determine the chemical composition of both powder and bulk samples under the conditions of different working distances and integration times. The results indicate that APXS can detect seven major elements, including Mg, Al, Si, K, Ca, Ti and Fe under the condition that the working distance is less than 30 mm and having an integration time of 30 min. The statistical deviation is smaller than 15%. This demonstrates the instrument's ability to detect major elements in the sample. Our measurements also indicate the increase of integration time could reduce the measurement error of peak area, which is useful for detecting the elements Mg, Al and Si. However, an increase in working distance can result in larger errors in measurement, which significantly affects the detection of the element Mg.展开更多
基金Supported by the Electronic Information Industry Development Foundation of China(20140806)the National Natural Science Foundation of China(61374121,61134007)
文摘In this paper,a two-layer hierarchical structure of optimization and control for polypropylene grade transition was raised to overcome process uncertain disturbances that led to the large deviation between the open-loop reference trajectory and the actual process.In the upper layer,the variant time scale based control vector parametric methods(VTS-CVP) was used for dynamic optimization of transition reference trajectory,while nonlinear model predictive controller(NMPC) based on closed-loop subspace and piece-wise linear(SSARX-PWL) model in the lower layer was tracking to the reference trajectory from the upper layer for overcoming high-frequency disturbances.Besides,mechanism about trajectory deviation detection and optimal trajectory updating online were introduced to ensure a smooth transition for the entire process.The proposed method was validated with the real data from an industrial double-loop propylene polymerization reaction process with developed dynamic mechanism mathematical model.
文摘In the Chang'e-3 mission, the Active Particle-induced X-ray Spectrometer(APXS) on the Yutu rover is used to analyze the chemical composition of lunar soil and rock samples. APXS data are only valid are only if the sensor head gets close to the target and integration time lasts long enough. Therefore, working distance and integration time are the dominant factors that affect APXS results. This study confirms the ability of APXS to detect elements and investigates the effects of distance and time on the measurements. We make use of a backup APXS instrument to determine the chemical composition of both powder and bulk samples under the conditions of different working distances and integration times. The results indicate that APXS can detect seven major elements, including Mg, Al, Si, K, Ca, Ti and Fe under the condition that the working distance is less than 30 mm and having an integration time of 30 min. The statistical deviation is smaller than 15%. This demonstrates the instrument's ability to detect major elements in the sample. Our measurements also indicate the increase of integration time could reduce the measurement error of peak area, which is useful for detecting the elements Mg, Al and Si. However, an increase in working distance can result in larger errors in measurement, which significantly affects the detection of the element Mg.