The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr...The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).展开更多
In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has...In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has emerged as a transformative tool in health care,offering rapid,sensitive,and specific identification of microorganisms.This editorial provides a comprehensive overview of LOC technology,highlighting its principles,advantages,applications,challenges,and future directions.Success studies from the field have demonstrated the practical benefits of LOC devices in clinical diagnostics,epidemiology,and food safety.Comparative studies have underscored the superiority of LOC technology over traditional methods,showcasing improvements in speed,accuracy,and portability.The future integration of LOC with biosensors,artificial intelligence,and data analytics promises further innovation and expansion.This call to action emphasizes the importance of continued research,investment,and adoption to realize the full potential of LOC technology in improving healthcare outcomes worldwide.展开更多
Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is k...Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.展开更多
Primary physical design of the Thomson scattering system for EAST, including the configuration of the system and the design considerations of different sections of the system, is presented. The expected measurability ...Primary physical design of the Thomson scattering system for EAST, including the configuration of the system and the design considerations of different sections of the system, is presented. The expected measurability of this design, namely an electron temperature of 513 eV to 5 keV and a plasma density beyond 0.5× 10^19 m^-3, fulfills the requirements of the EAST operation.展开更多
Neutron energy spectrometry diagnosis plays an important role in magnetic con- finement fusion. A new neutron time-of-flight (TOF) spectrometer with double scintillators is designed and optimized for the EAST toknma...Neutron energy spectrometry diagnosis plays an important role in magnetic con- finement fusion. A new neutron time-of-flight (TOF) spectrometer with double scintillators is designed and optimized for the EAST toknmak. A set of optimM parameters is obtained by Monte Carlo simulation, based on the GEANT4 and ROOT codes. The electronic setup of the measurement system is designed. The count rate capability is increased by introducing a flash ADC. The designed spectrometer with high resolution and efficiency is capable of being applied to fusion neutron diagnostics. Applications in mixed-energy and continuous energy neutron fields can also be considered.展开更多
The structural design of equatorial diagnostic port plug for international thermonuclear experimental reactor (ITER) was discussed in this paper. The induced electromagnetic (EM) loads of port plug and blanket shi...The structural design of equatorial diagnostic port plug for international thermonuclear experimental reactor (ITER) was discussed in this paper. The induced electromagnetic (EM) loads of port plug and blanket shielding module (BSM) were presented. The finite element analysis (FEA) and numerical calculation of the system were performed under the maximum loads. According to the American Society of Mechanical Engineers (ASME) criteria, the EM stress is far below the admissible failure boundary, which indicates that the system can resist the cooperative action of EM loads and device deadweight. The analysis could provide technical data and references for further analysis and optimized design of the system.展开更多
BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients ex...BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients exists.AIM To identify risk factors leading to prolonged diagnostic time in a German IBD cohort.METHODS Between 2012 and 2022,430 IBD patients from four Berlin hospitals were enrolled in a prospective study and asked to complete a 16-item questionnaire to determine features of the path leading to IBD diagnosis.Total diagnostic time was defined as the time from symptom onset to consulting a physician(patient waiting time)and from first consultation to IBD diagnosis(physician diagnostic time).Univariate and multivariate analyses were performed to identify risk factors for each time period.RESULTS The total diagnostic time was significantly longer in Crohn’s disease(CD)compared to ulcerative colitis(UC)patients(12.0 vs 4.0 mo;P<0.001),mainly due to increased physician diagnostic time(5.5 vs 1.0 mo;P<0.001).In a multivariate analysis,the predominant symptoms diarrhea(P=0.012)and skin lesions(P=0.028)as well as performed gastroscopy(P=0.042)were associated with longer physician diagnostic time in CD patients.In UC,fever was correlated(P=0.020)with shorter physician diagnostic time,while fatigue(P=0.011)and positive family history(P=0.046)were correlated with longer physician diagnostic time.CONCLUSION We demonstrated that CD patients compared to UC are at risk of long diagnostic delay.Future efforts should focus on shortening the diagnostic delay for a better outcome in these patients.展开更多
BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of...BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of patients remain unscreened,with>70%of cases diagnosed outside screening.Although identifying specific subgroups for whom CRC screening should be particularly recommended is crucial owing to limited resources,the association between the diagnostic routes and identification of these subgroups has been less appreciated.In the Japanese cancer registry,the diagnostic routes for groups discovered outside of screening are primarily categorized into those with comorbidities found during hospital visits and those with CRC-related symptoms.AIM To clarify the stage at CRC diagnosis based on diagnostic routes.METHODS We conducted a retrospective observational study using a cancer registry of patients with CRC between January 2016 and December 2019 at two hospitals.The diagnostic routes were primarily classified into three groups:Cancer screening,follow-up,and symptomatic.The early-stage was defined as Stages 0 or I.Multivariate and univariate logistic regressions were exploited to determine the odds of early-stage diagnosis in the symptomatic and cancer screening groups,referencing the follow-up group.The adjusted covariates were age,sex,and tumor location.RESULTS Of the 2083 patients,715(34.4%),1064(51.1%),and 304(14.6%)belonged to the follow-up,symptomatic,and cancer screening groups,respectively.Among the 2083 patients,CRCs diagnosed at an early stage were 57.3%(410 of 715),23.9%(254 of 1064),and 59.5%(181 of 304)in the follow-up,symptomatic,and cancer screening groups,respectively.The symptomatic group exhibited a lower likelihood of early-stage diagnosis than the follow-up group[P<0.001,adjusted odds ratio(aOR),0.23;95%confidence interval(95%CI):0.19-0.29].The likelihood of diagnosis at an early stage was similar between the follow-up and cancer screening groups(P=0.493,aOR for early-stage diagnosis in the cancer screening group vs follow-up group=1.11;95%CI=0.82-1.49).CONCLUSION CRCs detected during hospital visits for comorbidities were diagnosed earlier,similar to cancer screening.CRC screening should be recommended,particularly for patients without periodical hospital visits for comorbidities.展开更多
Vector of diagnostic signs(VDS)using torsional vibration(TV)signal on the main propulsion plant(MPP)is the vector of z maxima(or minima)values of the TV signal in accordance with the cylinder firing orders.The technic...Vector of diagnostic signs(VDS)using torsional vibration(TV)signal on the main propulsion plant(MPP)is the vector of z maxima(or minima)values of the TV signal in accordance with the cylinder firing orders.The technical states of the marine diesel engine(MDE)include R=z+1 classes and are presented in z-dimensional space coordinate of VDS.The presentation of Dk,k=1÷R using z diagnostic signs(Vi,i=1÷z)is nonfigurative and quite complicated.This paper aims to develop a new method for converting VDS from z-dimensional to 2-dimensional space(two-axes)based on the firing orders of the diesel cylinders,as an equivalent geometrical sign of the all diagnostic signs.The proposed model is useful for presenting a technical state Dk in two-dimensional space(x,y)for better visualization.The paper verifies the simulation of the classification illustration of the 7–state classes for the MDE 6S46-MCC,installed on the motor vessel(MV)34000DWT,using the new above mentioned method.The seven technical state classes(for 6-cylinder MDE,z=6)are drawn separately and visually in the Descartes.The received results are valuable to improve smart diagnostic system for analyzing normal/misfire states of cylinders in operation regimes.展开更多
Background: Blood eosinophilia is a common laboratory abnormality, and its characterization frequently represents a quandary for primary care physicians. Consequently, in France, specialists and particularly hematolog...Background: Blood eosinophilia is a common laboratory abnormality, and its characterization frequently represents a quandary for primary care physicians. Consequently, in France, specialists and particularly hematologists, often must investigate patients who present with blood eosinophilia that often, but not always, occurs because of allergic causes. Both the Departments of Hematology and Parasitology at Toulouse University Hospitals established a collaboration to rule out allergic causes of eosinophilia, particularly helminthiases, prior to initiating more sophisticated investigations.Methods: Since 2004, the authors employed the same protocol to investigate eosinophilic outpatients who attended the clinic of Parasitology at Toulouse University Hospitals, and they reported the performance of this diagnostic procedure that was designed to be rapid(no hospitalization required) and only moderately expensive.Results: A total of 406 patients who presented with blood eosinophilia greater than 0.5(×10~9, giga cells per litter, G/L) had an allergic etiology in 350(86.2%) cases. Among the remaining 56 subjects, 17 did not undergo a follow-up and 39 were referred to another specialized department, mostly Hematology. However, only 21 patients attended then were subsequently investigated. Non-allergic causes of eosinophilia, including 3 cases of the lymphoid variant of hypereosinophilic syndrome and 2 cases of myeloproliferative disorder, were identified in 14 patients, whereas 7 remained diagnosed as having idiopathic eosinophilia.Conclusion: This study underlines the need to investigate patients presenting with even moderate blood eosinophilia. The work-up that was employed appears to be efficient and versatile and may be used by any medical specialist, such as in hematology, infectious disease, or internal medicine departments, who needs to investigate eosinophilic patients and should initially rule out any etiology of allergic eosinophilia.展开更多
A Thomson scattering diagnostic system is under construction at the Joint Texas Experimental Tokamak(J-TEXT). A 1064 nm Nd:YAG laser with 50 Hz repetition rate is used as the laser source. We have used a software f...A Thomson scattering diagnostic system is under construction at the Joint Texas Experimental Tokamak(J-TEXT). A 1064 nm Nd:YAG laser with 50 Hz repetition rate is used as the laser source. We have used a software for careful and precise control of the laser through serial communication. A time sequence operating system has been developed to synchronize the laser control and data acquisition system with the central control system(CSS). The system operates commands from the CSS of J-TEXT and generates triggers for the laser and data acquisition system in the proper sequence. It also measures an asynchronous time value that is needed for accurate time stamping. All functions are served by a field-programmable gate array development platform that is suitable for high-speed data and signal processing applications.Several embedded peripherals, including Ethernet and USB 2.0, provide communication with the CSS and the server.展开更多
The electric field induced Lyman-a emission diagnostic aims to provide a non intrusive and precise measurement of the electric field in plasma, using a beam of hydrogen atoms prepared in the metastable 2s state. The m...The electric field induced Lyman-a emission diagnostic aims to provide a non intrusive and precise measurement of the electric field in plasma, using a beam of hydrogen atoms prepared in the metastable 2s state. The metastable particles are obtained by means of a proton beam extracted from a hydrogen plasma source, and neutralised by interaction with vaporised caesium. When a 2s atom enters a region where an electric field is present, it undergoes a transition to the 2p state (Stark mixing). It then quickly decays to the ground level, emitting Lyman-a radiation, which is collected by a photomultiplier. The 2s → 2p transition rate is proportional to the square of the magnitude of the electric field, and depends on the field oscillation frequency (with peaks around l GHz). By measuring the intensity of the Lyman-a radiation emitted by the beam it is possible to determine the magnitude of the field in a defined region. In this work, an analysis of the behaviour of the diagnostic under static or radiofrequency electric field is presented. Electric field simulations obtained with a finite element solver of Maxwell equations, combined with theoretical calculations of the Stark mixing transition rate, are used to develop a model for the interpretation of photomultiplier data. This method shows good agreement with experimental results for the static field case, and allows to measure the field magnitude for the oscillating case.展开更多
We describe the design and x-ray emission properties(temporal,spatial,and spectral)of Dry Pinch I,a portable X-pinch driver developed at Imperial College London.Dry Pinch I is a direct capacitor discharge device,30033...We describe the design and x-ray emission properties(temporal,spatial,and spectral)of Dry Pinch I,a portable X-pinch driver developed at Imperial College London.Dry Pinch I is a direct capacitor discharge device,30033003700 mm3 in size and∼50 kg in mass,that can be used as an external driver for x-ray diagnostics in high-energy-density physics experiments.Among key findings,the device is shown to reliably produce 1.1±0.3 ns long x-ray bursts that couple∼50 mJ of energy into photon energies from 1 to 10 keV.The average shot-to-shot jitter of these bursts is found to be 10±4.6 ns using a combination of x-ray and current diagnostics.The spatial extent of the x-ray hot spot from which the radiation emanates agrees with previously published results for X-pinches-suggesting a spot size of 10±6μm in the soft energy region(1–10 keV)and 190±100μm in the hard energy region(>10 keV).These characteristics mean that Dry Pinch I is ideally suited for use as a probe in experiments driven in the laboratory or at external facilities when more conventional sources of probing radiation are not available.At the same time,this is also the first detailed investigation of an X-pinch operating reliably at current rise rates of less than 1 kA/ns.展开更多
Technologies that measure activation of components of the DNA damage response (DDR) have applications in exposure assessment and personalized medicine. The DDR and associated DNA repair pathways encompass hundreds of ...Technologies that measure activation of components of the DNA damage response (DDR) have applications in exposure assessment and personalized medicine. The DDR and associated DNA repair pathways encompass hundreds of proteins, making detailed measurement of activation technically challenging and laborious. The purpose of our study was to develop protein-specific assays for certain DDR components on a high-throughput electrochemiluminescence (ECL)-based platform. We developed five working assay pairs for ataxia telangiectasia mutated (ATM), checkpoint kinase 2 (CHK2), phosphorylated-ATM S1981, phosphorylated-CHK2 T68 and phosphorylated-tumor protein p53 (p53) S15. We validated the ECL results against traditional immunoblot and γ-H2AX foci measures in cell and cancer models. In an effort to test the ECL-based technology in a clinical setting, we utilized peripheral blood mononuclear cells (PBMCs) from patients undergoing computed tomography (CT) scans. CT scans represent both a valuable medical imaging diagnostic and a controlled environmental exposure to ionizing radiation for research studies, as they deliver ~2 to 31 millisieverts (mSv) and are known to activate DDR components. In this study, we show that ECL-based technology can measure the basal and damage-induced levels of DDR components in patient PBMC samples. Using a blinded study design and patient matched pre- and post CT scan samples, we show that ECL-derived data can consistently (94% of the time, 15/16 patients) identify PBMCs that have been exposed to low dose ionizing radiation associated with CT scans. Ultimately, the results of our pilot clinical study support the idea that ECL-based technology is applicable for use in clinical and population cohorts that study components of the DDR.展开更多
In this article,we present the optical design of a novel diagnostic on the HL-2A tokamak,i.e.the 20-channel edge Lyman-alpha beam emission spectroscopy,which is a promising solution for edge density turbulence researc...In this article,we present the optical design of a novel diagnostic on the HL-2A tokamak,i.e.the 20-channel edge Lyman-alpha beam emission spectroscopy,which is a promising solution for edge density turbulence research on tokamaks,as it offers the possibility of density fluctuation measurement with a 3.3 mm spatial resolution while maintains a high temporal resolution of 1μs.The optical path,including the reflective collection optics,the high-dispersion spectrometer,and the linear detector array,is carefully optimized to obtain a good image quality and a high throughput.The maximum root mean square radius of the collection optics is 64μm.The detected photon flux is estimated to be about 1011 photons/s/channel.展开更多
The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimi...The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimize tissue fibrosis,which can lead to stricture formation.The healing process involves various phases:hemostasis and inflammation,proliferation,and remodeling.Mechanical staplers and sutures can cause inflammation and fibrosis due to the release of profibrotic chemokines.Compression anastomosis devices,including those made of nickel-titanium alloy,offer a minimally invasive option for various surgical challenges and have shown safety and efficacy.However,despite advancements,anastomotic techniques are evaluated based on leakage risk,with complications being a primary concern.Newer devices like Magnamosis use magnetic rings for compression anastomosis,demonstrating greater strength and patency compared to stapling.Magnetic technology is also being explored for other medical treatments.While there are promising results,particularly in animal models,the realworld application in humans is limited,and further research is needed to assess their safety and practicality.展开更多
The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer intervent...The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer interventions and appropriate care.Liver biopsy is currently considered the gold standard for the diagnosis and staging of MAFLD,but it has associated risks and limitations.This has spurred the exploration of non-invasive diagnostics for MAFLD,especially for steatohepatitis and fibrosis.These non-invasive approaches mostly include biomarkers and algorithms derived from anthropometric measurements,serum tests,imaging or stool metagenome profiling.However,they still need rigorous and widespread clinical validation for the diagnostic performance.展开更多
BACKGROUND Crochetage sign is a specific electrocardiographic manifestation of ostium secundum atrial septal defects(ASDs),which is associated with the severity of the left-to-right shunt.Herein,we reported a case of ...BACKGROUND Crochetage sign is a specific electrocardiographic manifestation of ostium secundum atrial septal defects(ASDs),which is associated with the severity of the left-to-right shunt.Herein,we reported a case of selective his bundle pacing(SHBP)that eliminated crochetage sign in a patient with ostium secundum ASD.CASE SUMMARY A 77-year-old man was admitted with a 2-year history of chest tightness and shortness of breath.Transthoracic echocardiography revealed an ostium secundum ASD.Twelve-lead electrocardiogram revealed atrial fibrillation with a prolonged relative risk interval,incomplete right bundle branch block,and crochetage sign.The patient was diagnosed with an ostium secundum ASD,atrial fibrillation with a second-degree atrioventricular block,and heart failure.The patient was treated with selective his bundle pacemaker implantation.After the procedure,crochetage sign disappeared during his bundle pacing on the electrocardiogram.CONCLUSION S-HBP eliminated crochetage sign on electrocardiogram.Crochetage sign may be a manifestation of a conduction system disorder.展开更多
BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated ...BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated and multifactorial;Therefore,sensitive and specific biomarkers are needed.Urinary exosome originate from diverse renal cells in nephron segments and partially mirror the pathological changes in the kidney.The microRNAs(miRNAs)in urinary exosome are remark-ably stable and highly tissue-specific for the kidney.METHODS Type 2 diabetic mellitus(T2DM)patients were recruited from the Second Hospital of Hebei Medical University and were divided into two groups:DM,diabetic pa-tients without albuminuria[urinary albumin to creatinine ratio(UACR)<30 mg/g]and DKD,diabetic patients with albuminuria(UACR≥30 mg/g).Healthy subjects were the normal control(NC)group.Urinary exosomal miR-145-5p,miR-27a-3p,and miR-29c-3p,were detected using real-time quantitative polymerase chain reaction.The correlation between exosomal miRNAs and the clinical in-dexes was evaluated.The diagnostic values of exosomal miR-145-5p and miR-27a-3p in DKD were determined using receiver operating characteristic(ROC)analysis.Biological functions of miR-145-5p were investigated by performing RESULTS Urinary exosomal expression of miR-145-5p and miR-27a-3p was more upregulated in the DKD group than in the DM group(miR-145-5p:4.54±1.45 vs 1.95±0.93,P<0.001;miR-27a-3p:2.33±0.79 vs 1.71±0.76,P<0.05)and the NC group(miR-145-5p:4.54±1.45 vs 1.55±0.83,P<0.001;miR-27a-3p:2.33±0.79 vs 1.10±0.51,P<0.001).The exosomal miR-145-5p and miR-27a-3p positively correlated with albuminuria and serum creatinine and negatively correlated with the estimated glomerular filtration rate.miR-27a-3p was also closely related to blood glucose,gly-cosylated hemoglobin A1c,and low-density lipoprotein cholesterol.ROC analysis revealed that miR-145-5p had a better area under the curve of 0.88[95%confidence interval(CI):0.784-0.985,P<0.0001]in diagnosing DKD than miR-27a-3p with 0.71(95%CI:0.547-0.871,P=0.0239).Bioinformatics analysis revealed that the target genes of miR-145-5p were located in the actin filament,cytoskeleton,and extracellular exosome and were involved in the pathological processes of DKD,including apoptosis,inflammation,and fibrosis.CONCLUSION Urinary exosomal miR-145-5p and miR-27a-3p may serve as novel noninvasive diagnostic biomarkers or promising therapeutic targets for DKD.展开更多
BACKGROUND Despite significant advancements in the medical treatment of primary hepato-cellular carcinoma(PHC)in recent years,enhancing therapeutic effects and im-proving prognosis remain substantial challenges worldw...BACKGROUND Despite significant advancements in the medical treatment of primary hepato-cellular carcinoma(PHC)in recent years,enhancing therapeutic effects and im-proving prognosis remain substantial challenges worldwide.AIM To investigate the expression levels of serum vascular endothelial growth factor(VEGF)and interleukin(IL)-17 in patients with PHC and evaluate their diagnostic value while exploring their relationship with patients’clinical characteristics.METHODS The study included 50 patients with confirmed PHC who visited Wuhan Han-yang Hospital from January 2021 to January 2022,and 50 healthy individuals from the same period served as the control group.Serum VEGF and IL-17 levels in both groups were measured by Enzyme-Linked Immunosorbent Assay,and their diagnostic value was assessed using receiver operating characteristic(ROC)curves.Pearson correlation analysis was performed to examine the relationship between serum VEGF and IL-17 levels.Pathological data of the PHC patients were analyzed to determine the relationship between serum VEGF and IL-17 levels and pathological characteristics.RESULTS Serum VEGF and IL-17 levels were significantly higher in the study group com-pared to the control group(P<0.05).No significant association was observed between serum VEGF and IL-17 levels and gender,age,combined cirrhosis,tumor diameter,or degree of differentiation(P>0.05).However,there was a significant relationship between clinical TNM stage,tumor metastasis,and serum VEGF and IL-17 levels(P<0.05).Correlation analysis revealed a positive correlation between serum VEGF and IL-17(P<0.05).ROC analysis demonstrated that both serum VEGF and IL-17 had good diagnostic efficacy for PHC.CONCLUSION Serum VEGF and IL-17 levels were significantly higher in PHC patients compared to healthy individuals.Their levels were closely related to pathological features such as tumor metastasis and clinical TNM stage,and there was a significant positive correlation between VEGF and IL-17.These biomarkers may serve as valuable reference in-dicators for the early diagnosis and treatment guidance of PHC.展开更多
基金supported by the National Key Research and Development Program of China(Nos.2019YFE03090100 and 2022YFE03100002)National Natural Science Foundation of China(No.12075241)。
文摘The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).
文摘In a recent case report in the World Journal of Clinical Cases,emphasized the crucial role of rapidly and accurately identifying pathogens to optimize patient treatment outcomes.Laboratory-on-a-chip(LOC)technology has emerged as a transformative tool in health care,offering rapid,sensitive,and specific identification of microorganisms.This editorial provides a comprehensive overview of LOC technology,highlighting its principles,advantages,applications,challenges,and future directions.Success studies from the field have demonstrated the practical benefits of LOC devices in clinical diagnostics,epidemiology,and food safety.Comparative studies have underscored the superiority of LOC technology over traditional methods,showcasing improvements in speed,accuracy,and portability.The future integration of LOC with biosensors,artificial intelligence,and data analytics promises further innovation and expansion.This call to action emphasizes the importance of continued research,investment,and adoption to realize the full potential of LOC technology in improving healthcare outcomes worldwide.
基金supported by the National Key Research&Development Program of China,Nos.2021YFC2501205(to YC),2022YFC24069004(to JL)the STI2030-Major Project,Nos.2021ZD0201101(to YC),2022ZD0211800(to YH)+2 种基金the National Natural Science Foundation of China(Major International Joint Research Project),No.82020108013(to YH)the Sino-German Center for Research Promotion,No.M-0759(to YH)a grant from Beijing Municipal Science&Technology Commission(Beijing Brain Initiative),No.Z201100005520018(to JL)。
文摘Several promising plasma biomarker proteins,such as amyloid-β(Aβ),tau,neurofilament light chain,and glial fibrillary acidic protein,are widely used for the diagnosis of neurodegenerative diseases.However,little is known about the long-term stability of these biomarker proteins in plasma samples stored at-80°C.We aimed to explore how storage time would affect the diagnostic accuracy of these biomarkers using a large cohort.Plasma samples from 229 cognitively unimpaired individuals,encompassing healthy controls and those experiencing subjective cognitive decline,as well as 99 patients with cognitive impairment,comprising those with mild cognitive impairment and dementia,were acquired from the Sino Longitudinal Study on Cognitive Decline project.These samples were stored at-80°C for up to 6 years before being used in this study.Our results showed that plasma levels of Aβ42,Aβ40,neurofilament light chain,and glial fibrillary acidic protein were not significantly correlated with sample storage time.However,the level of total tau showed a negative correlation with sample storage time.Notably,in individuals without cognitive impairment,plasma levels of total protein and tau phosphorylated protein threonine 181(p-tau181)also showed a negative correlation with sample storage time.This was not observed in individuals with cognitive impairment.Consequently,we speculate that the diagnostic accuracy of plasma p-tau181 and the p-tau181 to total tau ratio may be influenced by sample storage time.Therefore,caution is advised when using these plasma biomarkers for the identification of neurodegenerative diseases,such as Alzheimer's disease.Furthermore,in cohort studies,it is important to consider the impact of storage time on the overall results.
基金supported by National Natural Science Foundation of China (Nos. 10725523, 10721505 and 10805056)
文摘Primary physical design of the Thomson scattering system for EAST, including the configuration of the system and the design considerations of different sections of the system, is presented. The expected measurability of this design, namely an electron temperature of 513 eV to 5 keV and a plasma density beyond 0.5× 10^19 m^-3, fulfills the requirements of the EAST operation.
基金supported by the State Key Development Program for Basic Research of China(Nos.2008CB717803,2009GB107001,and2007CB209903)the Research Fund for the Doctoral Program of Higher Education of China(No.200610011023)the National Natural Science Foundation of China(No.10875002)
文摘Neutron energy spectrometry diagnosis plays an important role in magnetic con- finement fusion. A new neutron time-of-flight (TOF) spectrometer with double scintillators is designed and optimized for the EAST toknmak. A set of optimM parameters is obtained by Monte Carlo simulation, based on the GEANT4 and ROOT codes. The electronic setup of the measurement system is designed. The count rate capability is increased by introducing a flash ADC. The designed spectrometer with high resolution and efficiency is capable of being applied to fusion neutron diagnostics. Applications in mixed-energy and continuous energy neutron fields can also be considered.
文摘The structural design of equatorial diagnostic port plug for international thermonuclear experimental reactor (ITER) was discussed in this paper. The induced electromagnetic (EM) loads of port plug and blanket shielding module (BSM) were presented. The finite element analysis (FEA) and numerical calculation of the system were performed under the maximum loads. According to the American Society of Mechanical Engineers (ASME) criteria, the EM stress is far below the admissible failure boundary, which indicates that the system can resist the cooperative action of EM loads and device deadweight. The analysis could provide technical data and references for further analysis and optimized design of the system.
文摘BACKGROUND Early diagnosis is key to prevent bowel damage in inflammatory bowel disease(IBD).Risk factor analyses linked with delayed diagnosis in European IBD patients are scarce and no data in German IBD patients exists.AIM To identify risk factors leading to prolonged diagnostic time in a German IBD cohort.METHODS Between 2012 and 2022,430 IBD patients from four Berlin hospitals were enrolled in a prospective study and asked to complete a 16-item questionnaire to determine features of the path leading to IBD diagnosis.Total diagnostic time was defined as the time from symptom onset to consulting a physician(patient waiting time)and from first consultation to IBD diagnosis(physician diagnostic time).Univariate and multivariate analyses were performed to identify risk factors for each time period.RESULTS The total diagnostic time was significantly longer in Crohn’s disease(CD)compared to ulcerative colitis(UC)patients(12.0 vs 4.0 mo;P<0.001),mainly due to increased physician diagnostic time(5.5 vs 1.0 mo;P<0.001).In a multivariate analysis,the predominant symptoms diarrhea(P=0.012)and skin lesions(P=0.028)as well as performed gastroscopy(P=0.042)were associated with longer physician diagnostic time in CD patients.In UC,fever was correlated(P=0.020)with shorter physician diagnostic time,while fatigue(P=0.011)and positive family history(P=0.046)were correlated with longer physician diagnostic time.CONCLUSION We demonstrated that CD patients compared to UC are at risk of long diagnostic delay.Future efforts should focus on shortening the diagnostic delay for a better outcome in these patients.
基金the Foundation for Cancer Research supported by Kyoto Preventive Medical Center and the Japan Society for the Promotion of Science(JSPS)Grants-in-Aid KAKENHI,No.JP 22K21080.
文摘BACKGROUND Colorectal cancer(CRC)is a global health concern,with advanced-stage diagnoses contributing to poor prognoses.The efficacy of CRC screening has been well-established;nevertheless,a significant proportion of patients remain unscreened,with>70%of cases diagnosed outside screening.Although identifying specific subgroups for whom CRC screening should be particularly recommended is crucial owing to limited resources,the association between the diagnostic routes and identification of these subgroups has been less appreciated.In the Japanese cancer registry,the diagnostic routes for groups discovered outside of screening are primarily categorized into those with comorbidities found during hospital visits and those with CRC-related symptoms.AIM To clarify the stage at CRC diagnosis based on diagnostic routes.METHODS We conducted a retrospective observational study using a cancer registry of patients with CRC between January 2016 and December 2019 at two hospitals.The diagnostic routes were primarily classified into three groups:Cancer screening,follow-up,and symptomatic.The early-stage was defined as Stages 0 or I.Multivariate and univariate logistic regressions were exploited to determine the odds of early-stage diagnosis in the symptomatic and cancer screening groups,referencing the follow-up group.The adjusted covariates were age,sex,and tumor location.RESULTS Of the 2083 patients,715(34.4%),1064(51.1%),and 304(14.6%)belonged to the follow-up,symptomatic,and cancer screening groups,respectively.Among the 2083 patients,CRCs diagnosed at an early stage were 57.3%(410 of 715),23.9%(254 of 1064),and 59.5%(181 of 304)in the follow-up,symptomatic,and cancer screening groups,respectively.The symptomatic group exhibited a lower likelihood of early-stage diagnosis than the follow-up group[P<0.001,adjusted odds ratio(aOR),0.23;95%confidence interval(95%CI):0.19-0.29].The likelihood of diagnosis at an early stage was similar between the follow-up and cancer screening groups(P=0.493,aOR for early-stage diagnosis in the cancer screening group vs follow-up group=1.11;95%CI=0.82-1.49).CONCLUSION CRCs detected during hospital visits for comorbidities were diagnosed earlier,similar to cancer screening.CRC screening should be recommended,particularly for patients without periodical hospital visits for comorbidities.
文摘Vector of diagnostic signs(VDS)using torsional vibration(TV)signal on the main propulsion plant(MPP)is the vector of z maxima(or minima)values of the TV signal in accordance with the cylinder firing orders.The technical states of the marine diesel engine(MDE)include R=z+1 classes and are presented in z-dimensional space coordinate of VDS.The presentation of Dk,k=1÷R using z diagnostic signs(Vi,i=1÷z)is nonfigurative and quite complicated.This paper aims to develop a new method for converting VDS from z-dimensional to 2-dimensional space(two-axes)based on the firing orders of the diesel cylinders,as an equivalent geometrical sign of the all diagnostic signs.The proposed model is useful for presenting a technical state Dk in two-dimensional space(x,y)for better visualization.The paper verifies the simulation of the classification illustration of the 7–state classes for the MDE 6S46-MCC,installed on the motor vessel(MV)34000DWT,using the new above mentioned method.The seven technical state classes(for 6-cylinder MDE,z=6)are drawn separately and visually in the Descartes.The received results are valuable to improve smart diagnostic system for analyzing normal/misfire states of cylinders in operation regimes.
文摘Background: Blood eosinophilia is a common laboratory abnormality, and its characterization frequently represents a quandary for primary care physicians. Consequently, in France, specialists and particularly hematologists, often must investigate patients who present with blood eosinophilia that often, but not always, occurs because of allergic causes. Both the Departments of Hematology and Parasitology at Toulouse University Hospitals established a collaboration to rule out allergic causes of eosinophilia, particularly helminthiases, prior to initiating more sophisticated investigations.Methods: Since 2004, the authors employed the same protocol to investigate eosinophilic outpatients who attended the clinic of Parasitology at Toulouse University Hospitals, and they reported the performance of this diagnostic procedure that was designed to be rapid(no hospitalization required) and only moderately expensive.Results: A total of 406 patients who presented with blood eosinophilia greater than 0.5(×10~9, giga cells per litter, G/L) had an allergic etiology in 350(86.2%) cases. Among the remaining 56 subjects, 17 did not undergo a follow-up and 39 were referred to another specialized department, mostly Hematology. However, only 21 patients attended then were subsequently investigated. Non-allergic causes of eosinophilia, including 3 cases of the lymphoid variant of hypereosinophilic syndrome and 2 cases of myeloproliferative disorder, were identified in 14 patients, whereas 7 remained diagnosed as having idiopathic eosinophilia.Conclusion: This study underlines the need to investigate patients presenting with even moderate blood eosinophilia. The work-up that was employed appears to be efficient and versatile and may be used by any medical specialist, such as in hematology, infectious disease, or internal medicine departments, who needs to investigate eosinophilic patients and should initially rule out any etiology of allergic eosinophilia.
基金supported by the National Magnetic Confinement Fusion Science Program of China under Contract No.2015GB111001by National Natural Science Foundation of China(Grant No.11575067)
文摘A Thomson scattering diagnostic system is under construction at the Joint Texas Experimental Tokamak(J-TEXT). A 1064 nm Nd:YAG laser with 50 Hz repetition rate is used as the laser source. We have used a software for careful and precise control of the laser through serial communication. A time sequence operating system has been developed to synchronize the laser control and data acquisition system with the central control system(CSS). The system operates commands from the CSS of J-TEXT and generates triggers for the laser and data acquisition system in the proper sequence. It also measures an asynchronous time value that is needed for accurate time stamping. All functions are served by a field-programmable gate array development platform that is suitable for high-speed data and signal processing applications.Several embedded peripherals, including Ethernet and USB 2.0, provide communication with the CSS and the server.
文摘The electric field induced Lyman-a emission diagnostic aims to provide a non intrusive and precise measurement of the electric field in plasma, using a beam of hydrogen atoms prepared in the metastable 2s state. The metastable particles are obtained by means of a proton beam extracted from a hydrogen plasma source, and neutralised by interaction with vaporised caesium. When a 2s atom enters a region where an electric field is present, it undergoes a transition to the 2p state (Stark mixing). It then quickly decays to the ground level, emitting Lyman-a radiation, which is collected by a photomultiplier. The 2s → 2p transition rate is proportional to the square of the magnitude of the electric field, and depends on the field oscillation frequency (with peaks around l GHz). By measuring the intensity of the Lyman-a radiation emitted by the beam it is possible to determine the magnitude of the field in a defined region. In this work, an analysis of the behaviour of the diagnostic under static or radiofrequency electric field is presented. Electric field simulations obtained with a finite element solver of Maxwell equations, combined with theoretical calculations of the Stark mixing transition rate, are used to develop a model for the interpretation of photomultiplier data. This method shows good agreement with experimental results for the static field case, and allows to measure the field magnitude for the oscillating case.
基金Parts of the research detailed were funded by First Light Fusion Ltd.,the U.K.EPSRCthe U.S.Department of Energy under Cooperative Agreement Nos.DE-NA0003764 and DE-SC0018088.
文摘We describe the design and x-ray emission properties(temporal,spatial,and spectral)of Dry Pinch I,a portable X-pinch driver developed at Imperial College London.Dry Pinch I is a direct capacitor discharge device,30033003700 mm3 in size and∼50 kg in mass,that can be used as an external driver for x-ray diagnostics in high-energy-density physics experiments.Among key findings,the device is shown to reliably produce 1.1±0.3 ns long x-ray bursts that couple∼50 mJ of energy into photon energies from 1 to 10 keV.The average shot-to-shot jitter of these bursts is found to be 10±4.6 ns using a combination of x-ray and current diagnostics.The spatial extent of the x-ray hot spot from which the radiation emanates agrees with previously published results for X-pinches-suggesting a spot size of 10±6μm in the soft energy region(1–10 keV)and 190±100μm in the hard energy region(>10 keV).These characteristics mean that Dry Pinch I is ideally suited for use as a probe in experiments driven in the laboratory or at external facilities when more conventional sources of probing radiation are not available.At the same time,this is also the first detailed investigation of an X-pinch operating reliably at current rise rates of less than 1 kA/ns.
文摘Technologies that measure activation of components of the DNA damage response (DDR) have applications in exposure assessment and personalized medicine. The DDR and associated DNA repair pathways encompass hundreds of proteins, making detailed measurement of activation technically challenging and laborious. The purpose of our study was to develop protein-specific assays for certain DDR components on a high-throughput electrochemiluminescence (ECL)-based platform. We developed five working assay pairs for ataxia telangiectasia mutated (ATM), checkpoint kinase 2 (CHK2), phosphorylated-ATM S1981, phosphorylated-CHK2 T68 and phosphorylated-tumor protein p53 (p53) S15. We validated the ECL results against traditional immunoblot and γ-H2AX foci measures in cell and cancer models. In an effort to test the ECL-based technology in a clinical setting, we utilized peripheral blood mononuclear cells (PBMCs) from patients undergoing computed tomography (CT) scans. CT scans represent both a valuable medical imaging diagnostic and a controlled environmental exposure to ionizing radiation for research studies, as they deliver ~2 to 31 millisieverts (mSv) and are known to activate DDR components. In this study, we show that ECL-based technology can measure the basal and damage-induced levels of DDR components in patient PBMC samples. Using a blinded study design and patient matched pre- and post CT scan samples, we show that ECL-derived data can consistently (94% of the time, 15/16 patients) identify PBMCs that have been exposed to low dose ionizing radiation associated with CT scans. Ultimately, the results of our pilot clinical study support the idea that ECL-based technology is applicable for use in clinical and population cohorts that study components of the DDR.
基金supported by the National Key R&D Program of China(Nos.2017YFE0301201 and 2018YFE0303102)National Natural Science Foundation of China(Nos.11875124 and 12075241).
文摘In this article,we present the optical design of a novel diagnostic on the HL-2A tokamak,i.e.the 20-channel edge Lyman-alpha beam emission spectroscopy,which is a promising solution for edge density turbulence research on tokamaks,as it offers the possibility of density fluctuation measurement with a 3.3 mm spatial resolution while maintains a high temporal resolution of 1μs.The optical path,including the reflective collection optics,the high-dispersion spectrometer,and the linear detector array,is carefully optimized to obtain a good image quality and a high throughput.The maximum root mean square radius of the collection optics is 64μm.The detected photon flux is estimated to be about 1011 photons/s/channel.
文摘The development of intestinal anastomosis techniques,including hand suturing,stapling,and compression anastomoses,has been a significant advancement in surgical practice.These methods aim to prevent leakage and minimize tissue fibrosis,which can lead to stricture formation.The healing process involves various phases:hemostasis and inflammation,proliferation,and remodeling.Mechanical staplers and sutures can cause inflammation and fibrosis due to the release of profibrotic chemokines.Compression anastomosis devices,including those made of nickel-titanium alloy,offer a minimally invasive option for various surgical challenges and have shown safety and efficacy.However,despite advancements,anastomotic techniques are evaluated based on leakage risk,with complications being a primary concern.Newer devices like Magnamosis use magnetic rings for compression anastomosis,demonstrating greater strength and patency compared to stapling.Magnetic technology is also being explored for other medical treatments.While there are promising results,particularly in animal models,the realworld application in humans is limited,and further research is needed to assess their safety and practicality.
基金Supported by The National Natural Science Foundation of China,No.82104525.
文摘The population with metabolic dysfunction-associated fatty liver disease(MAFLD)is increasingly common worldwide.Identification of people at risk of progression to advanced stages is necessary to timely offer interventions and appropriate care.Liver biopsy is currently considered the gold standard for the diagnosis and staging of MAFLD,but it has associated risks and limitations.This has spurred the exploration of non-invasive diagnostics for MAFLD,especially for steatohepatitis and fibrosis.These non-invasive approaches mostly include biomarkers and algorithms derived from anthropometric measurements,serum tests,imaging or stool metagenome profiling.However,they still need rigorous and widespread clinical validation for the diagnostic performance.
文摘BACKGROUND Crochetage sign is a specific electrocardiographic manifestation of ostium secundum atrial septal defects(ASDs),which is associated with the severity of the left-to-right shunt.Herein,we reported a case of selective his bundle pacing(SHBP)that eliminated crochetage sign in a patient with ostium secundum ASD.CASE SUMMARY A 77-year-old man was admitted with a 2-year history of chest tightness and shortness of breath.Transthoracic echocardiography revealed an ostium secundum ASD.Twelve-lead electrocardiogram revealed atrial fibrillation with a prolonged relative risk interval,incomplete right bundle branch block,and crochetage sign.The patient was diagnosed with an ostium secundum ASD,atrial fibrillation with a second-degree atrioventricular block,and heart failure.The patient was treated with selective his bundle pacemaker implantation.After the procedure,crochetage sign disappeared during his bundle pacing on the electrocardiogram.CONCLUSION S-HBP eliminated crochetage sign on electrocardiogram.Crochetage sign may be a manifestation of a conduction system disorder.
基金Supported by the Nature Science Foundation of Hebei Province,No.H2023104011.
文摘BACKGROUND Diabetic kidney disease(DKD),characterized by increased urinary microalbumin levels and decreased renal function,is the primary cause of end-stage renal di-sease.Its pathological mechanisms are complicated and multifactorial;Therefore,sensitive and specific biomarkers are needed.Urinary exosome originate from diverse renal cells in nephron segments and partially mirror the pathological changes in the kidney.The microRNAs(miRNAs)in urinary exosome are remark-ably stable and highly tissue-specific for the kidney.METHODS Type 2 diabetic mellitus(T2DM)patients were recruited from the Second Hospital of Hebei Medical University and were divided into two groups:DM,diabetic pa-tients without albuminuria[urinary albumin to creatinine ratio(UACR)<30 mg/g]and DKD,diabetic patients with albuminuria(UACR≥30 mg/g).Healthy subjects were the normal control(NC)group.Urinary exosomal miR-145-5p,miR-27a-3p,and miR-29c-3p,were detected using real-time quantitative polymerase chain reaction.The correlation between exosomal miRNAs and the clinical in-dexes was evaluated.The diagnostic values of exosomal miR-145-5p and miR-27a-3p in DKD were determined using receiver operating characteristic(ROC)analysis.Biological functions of miR-145-5p were investigated by performing RESULTS Urinary exosomal expression of miR-145-5p and miR-27a-3p was more upregulated in the DKD group than in the DM group(miR-145-5p:4.54±1.45 vs 1.95±0.93,P<0.001;miR-27a-3p:2.33±0.79 vs 1.71±0.76,P<0.05)and the NC group(miR-145-5p:4.54±1.45 vs 1.55±0.83,P<0.001;miR-27a-3p:2.33±0.79 vs 1.10±0.51,P<0.001).The exosomal miR-145-5p and miR-27a-3p positively correlated with albuminuria and serum creatinine and negatively correlated with the estimated glomerular filtration rate.miR-27a-3p was also closely related to blood glucose,gly-cosylated hemoglobin A1c,and low-density lipoprotein cholesterol.ROC analysis revealed that miR-145-5p had a better area under the curve of 0.88[95%confidence interval(CI):0.784-0.985,P<0.0001]in diagnosing DKD than miR-27a-3p with 0.71(95%CI:0.547-0.871,P=0.0239).Bioinformatics analysis revealed that the target genes of miR-145-5p were located in the actin filament,cytoskeleton,and extracellular exosome and were involved in the pathological processes of DKD,including apoptosis,inflammation,and fibrosis.CONCLUSION Urinary exosomal miR-145-5p and miR-27a-3p may serve as novel noninvasive diagnostic biomarkers or promising therapeutic targets for DKD.
文摘BACKGROUND Despite significant advancements in the medical treatment of primary hepato-cellular carcinoma(PHC)in recent years,enhancing therapeutic effects and im-proving prognosis remain substantial challenges worldwide.AIM To investigate the expression levels of serum vascular endothelial growth factor(VEGF)and interleukin(IL)-17 in patients with PHC and evaluate their diagnostic value while exploring their relationship with patients’clinical characteristics.METHODS The study included 50 patients with confirmed PHC who visited Wuhan Han-yang Hospital from January 2021 to January 2022,and 50 healthy individuals from the same period served as the control group.Serum VEGF and IL-17 levels in both groups were measured by Enzyme-Linked Immunosorbent Assay,and their diagnostic value was assessed using receiver operating characteristic(ROC)curves.Pearson correlation analysis was performed to examine the relationship between serum VEGF and IL-17 levels.Pathological data of the PHC patients were analyzed to determine the relationship between serum VEGF and IL-17 levels and pathological characteristics.RESULTS Serum VEGF and IL-17 levels were significantly higher in the study group com-pared to the control group(P<0.05).No significant association was observed between serum VEGF and IL-17 levels and gender,age,combined cirrhosis,tumor diameter,or degree of differentiation(P>0.05).However,there was a significant relationship between clinical TNM stage,tumor metastasis,and serum VEGF and IL-17 levels(P<0.05).Correlation analysis revealed a positive correlation between serum VEGF and IL-17(P<0.05).ROC analysis demonstrated that both serum VEGF and IL-17 had good diagnostic efficacy for PHC.CONCLUSION Serum VEGF and IL-17 levels were significantly higher in PHC patients compared to healthy individuals.Their levels were closely related to pathological features such as tumor metastasis and clinical TNM stage,and there was a significant positive correlation between VEGF and IL-17.These biomarkers may serve as valuable reference in-dicators for the early diagnosis and treatment guidance of PHC.