This paper deals with flexural concrete members reinforced longitudinally but without transverse reinforcement. The conducted experimental investigations have shown that beams without web reinforcement may fail withou...This paper deals with flexural concrete members reinforced longitudinally but without transverse reinforcement. The conducted experimental investigations have shown that beams without web reinforcement may fail without attaining their full flexural capacity and then shear governs their failure. In the paper, there are presented recent results of the author's own experiments, which aimed at disclosing some aspects of the propagation of cracks in longitudinally reinforced concrete beams without stirrups. The experimental program has been designed especially to investigate the influence of the shear span-to-depth ratio on diagonal crack propagation and load carrying capacity of tested beams.展开更多
Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan.The analysis results show that this kind of composite wall panel works very w...Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan.The analysis results show that this kind of composite wall panel works very well,and can be regarded as a solid panel.The composite wall panel with a hidden frame is essential for bringing its effect on shear resistance into full play.Comprehensive analysis of the shear-resistant behavior of the composite wall panel suggests that the shear of the composite shear wall panel can be controlled by the cracking strength of the web shearing diagonal crack.展开更多
Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan in this paper. The analysis results show that this kind of composite wall pa...Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan in this paper. The analysis results show that this kind of composite wall panel works very well, and can be regarded as a solid panel. The composite wall panel with a hidden frame is essential for bringing its effect on shear resistance into full play. Comprehensive analysis of the shear-resistant behavior of the composite wall panel suggests that the shear of the composite shear wall panel can be controlled by the cracking strength of the web shearing diagonal crack.展开更多
文摘This paper deals with flexural concrete members reinforced longitudinally but without transverse reinforcement. The conducted experimental investigations have shown that beams without web reinforcement may fail without attaining their full flexural capacity and then shear governs their failure. In the paper, there are presented recent results of the author's own experiments, which aimed at disclosing some aspects of the propagation of cracks in longitudinally reinforced concrete beams without stirrups. The experimental program has been designed especially to investigate the influence of the shear span-to-depth ratio on diagonal crack propagation and load carrying capacity of tested beams.
基金Project(50948036)supported by the National Natural Science Foundation of ChinaProject(2012H0028)supported by Key Scientific and Technological Planning Project of Fujian Province,China+2 种基金Projects(2013J01192,2013J01196)supported by Natural Science Foundation Planning Project of Fujian Province,ChinaProject(2013Z37)supported by Key Scientific and Technological Planning Project of Quanzhou City,ChinaProject(2014KJTD05)supported by Program for Scientific and Technological Innovation Team and Leading Talent of Huaqiao University,China
文摘Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan.The analysis results show that this kind of composite wall panel works very well,and can be regarded as a solid panel.The composite wall panel with a hidden frame is essential for bringing its effect on shear resistance into full play.Comprehensive analysis of the shear-resistant behavior of the composite wall panel suggests that the shear of the composite shear wall panel can be controlled by the cracking strength of the web shearing diagonal crack.
基金Supported by Science and Technology Developm entFund of Tianjin Institutions of Higher L earning(0 1- 2 0 2 12 )
文摘Shear test results for a composite wall panel in a light composite structure system are compared with test results for shear walls in Japan in this paper. The analysis results show that this kind of composite wall panel works very well, and can be regarded as a solid panel. The composite wall panel with a hidden frame is essential for bringing its effect on shear resistance into full play. Comprehensive analysis of the shear-resistant behavior of the composite wall panel suggests that the shear of the composite shear wall panel can be controlled by the cracking strength of the web shearing diagonal crack.