期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Comparison of Different Culture Mode for Long-term Expansion of Neural Stem Cells
1
作者 Ke ZHENG Dan GE Tian-Qing LIU~Δ Xue-Hu MA(Stem Cell and Tissue Engineering Laboratory, Dalian University of Technology, Dalian 116024, China) 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2005年第S1期113-115,共3页
关键词 NSCS cell comparison of Different Culture Mode for Long-term Expansion of Neural Stem Cells LONG
下载PDF
Comparison of Mineral Contents in Three Different Tobacco Formulations
2
作者 HOUAS Ikram TEYEB Hassen +5 位作者 Arancha ROCHINA-MARCO DOUKI Wahiba NAJJAR Mohamed Fadhel GAHA Lotfi CERVERA MariaLuisa DE LA GUARDIA Miguel 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2017年第1期52-58,共7页
We identified and quantified a variety of mineral elements in 18 tobacco samples purchased from a Tunisian market. In total, 25 mineral elements have been measured in cigarettes, water pipe tobacco, and smokeless toba... We identified and quantified a variety of mineral elements in 18 tobacco samples purchased from a Tunisian market. In total, 25 mineral elements have been measured in cigarettes, water pipe tobacco, and smokeless tobacco using inductively coupled plasma-optical emission spectroscopy following microwave-assisted digestion. Statistical analyses were performed using SPSSTM, version 18.0. The lowest concentrations of all studied elements were observed in water pipe tobacco. Significantly higher concentrations of Al, Fe, Mg, Na, Ca, Cr, and Co were found in smokeless tobacco, while cigarettes brands contained the highest concentrations of K, Mn, Ni, Ba, and Sr. There was no significant difference between the mineral contents of local and foreign cigarettes and conventional and light cigarettes. Our findings demonstrated that local smokeless tobacco appears to be the most hazardous tobacco type. The concentration of minerals in light cigarettes was not significantly different from the concentration in conventional cigarettes. 展开更多
关键词 comparison of Mineral Contents in Three Different Tobacco Formulations
下载PDF
Comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping, transcranial Doppler sonography and computer tomography examinations
3
作者 Dongruo He Xiaoying Xu +1 位作者 Yinghui Zhang Guochao Han 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期379-381,共3页
BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderat... BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination. 展开更多
关键词 HIE comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping transcranial Doppler sonography and computer tomography examinations
下载PDF
A survey of Higher Vocational Students' upward Comparative Parenting
4
作者 Hongyang Liu Xuechuang He 《Journal of Contemporary Educational Research》 2020年第4期74-80,共7页
This study is aim at investigate the current situation of higher vocational students receiving upward comparative parenting and the differences in upward comparative parenting among higher vocational college students ... This study is aim at investigate the current situation of higher vocational students receiving upward comparative parenting and the differences in upward comparative parenting among higher vocational college students with different demographic variables.By using the self-designed upward comparative parenting questionnaire to survey 1075 higher vocational college students,the results show that:In general,higher vocational college students receive the highest frequency of upward Comparative Parenting(2.95±1.57)on the level of learning diligence,and the frequency of upward Comparative Parenting(2.62±1.27)for male higher vocational students is higher than that for female students(2.39±1.17).The subjects from urban areas(2.56±1.29)were significantly higher than those from rural areas(2.39±1.14).Conclusion:upward comparat ive parenting is a common phenomenon among higher vocational college students in China. 展开更多
关键词 Higher vocational college students Upward comparative parenting difference comparison
下载PDF
Performance comparison among three different Stokes vector direct-detection receivers
5
作者 申晓杰 霍佳皓 +7 位作者 周娴 钟康平 苑金辉 涂佳静 隆克平 余长源 刘伯涛 吕超 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第10期18-23,共6页
Stokes vectors direct detection(SV-DD) is an effective solution for short-reach optical communications. In this Letter, we investigate two-dimensional-modulation direct-detection systems based on three Stokes vector... Stokes vectors direct detection(SV-DD) is an effective solution for short-reach optical communications. In this Letter, we investigate two-dimensional-modulation direct-detection systems based on three Stokes vector receivers(SVRs). The influences of three key factors including the states-of-polarization(SOP), the splitting ratio of the coupler, and the excess loss(EL) are studied in detail. It is shown that the splitting ratio for achieving optimum performance will be changed with SOP and EL conditions. Among these SVRs, the3 × 3 coupler-based receiver with its optimal splitting ratio shows the best bit error rate performance and stability against the change of SOP. 展开更多
关键词 SC dBm Performance comparison among three different Stokes vector direct-detection receivers SOP PDM
原文传递
Comparison of Governance Structures of Chinese Enterprises with Different Types of Ownership
6
《China & World Economy》 SCIE 2001年第6期13-21,共9页
关键词 comparison of Governance Structures of Chinese Enterprises with Different Types of Ownership
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部