期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Non Ideal Schottky Barrier Diode’s Parameters Extraction and Materials Identification from Dark I-V-T Characteristics
1
作者 M. Bashahu D. Ngendabanyikwa P. Nyandwi 《Journal of Modern Physics》 2022年第3期285-300,共16页
Several parameters of a commercial Si-based Schottky barrier diode (SBD) with unknown metal material and semiconductor-type have been investigated in this work from dark forward and reverse I-V characteristics in the ... Several parameters of a commercial Si-based Schottky barrier diode (SBD) with unknown metal material and semiconductor-type have been investigated in this work from dark forward and reverse I-V characteristics in the temperature (T) range of [274.5 K - 366.5 K]. Those parameters include the reverse saturation current (I<sub>s</sub>), the ideality factor (n), the series and the shunt resistances (R<sub>s</sub> and R<sub>sh</sub>), the effective and the zero bias barrier heights (Φ<sub>B</sub> and Φ<sub>B0</sub>), the product of the electrical active area (A) and the effective Richardson constant (A**), the built-in potential (V<sub>bi</sub>), together with the semiconductor doping concentration (N<sub>A</sub> or N<sub>D</sub>). Some of them have been extracted by using two or three different methods. The main features of each approach have been clearly stated. From one parameter to another, results have been discussed in terms of structure performance, comparison on one another when extracted from different methods, accordance or discordance with data from other works, and parameter’s temperature or voltage dependence. A comparison of results on Φ<sub>B</sub>, ΦB0</sub>, n and N<sub>A</sub> or N<sub>D</sub> parameters with some available data in literature for the same parameters, has especially led to clear propositions on the identity of the analyzed SBD’s metal and semiconductor-type. 展开更多
关键词 SBD Dark Forward and Reverse I-V-T Characteristics different parameters Extraction Methods Identification of the Structure’s Metal and Semiconductor-Type
下载PDF
Comparisons and optimization of two absorption chiller types by considering heat transfer area,exergy and economy as single-objective functions
2
作者 Yida Qiu Jingkun Wang +3 位作者 Jing Han Yuzhu Chen Jun Wang Peter D.Lund 《Clean Energy》 EI CSCD 2024年第1期55-65,共11页
Absorption cooling technology is an environmentally friendly method to generate continuous chilled water making use of multiple thermal sources,such as waste heat and renewable thermal energy.In this study,two absorpt... Absorption cooling technology is an environmentally friendly method to generate continuous chilled water making use of multiple thermal sources,such as waste heat and renewable thermal energy.In this study,two absorption chillers(nominal capacity of 400 kW)with series and parallel connections are evaluated.To research the ideal configuration of chillers after thermodynamic analysis,the structures of the chillers are optimized using the particle swarm optimization algorithm by considering the heat transfer area(HTA),exergy efficiency and total annual cost as single-objective functions.The impact of temperature differences between external and internal flows,heat exchanger efficiencies and the solution allocation ratio is estimated.The optimized HTA,coefficient of perform-ance,exergy efficiency and total annual cost are 149.0 m^(2),1.56,29.44%and$229119 for the series-connected chiller,and 146.7 m^(2),1.59,31.45%and$234562 for the parallel-connected type,respectively.Under the lowest HTA condition,compared with the reference simulation results,the energy and exergy performances are improved,while the annual total cost is higher.The annual total cost is highest when maximizing the exergy efficiency,which is attributed to the increase in the HTA.The operating cost accounts for 27.42%(series type)and 26.54%(parallel type)when the annual cost is the lowest. 展开更多
关键词 absorption chiller series/parallel-connected temperature difference parameters solution allocation ratio
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部