In the first part of this article a more general DEI equation was derived using simple concepts. Not only does the new DEI equation explain all the problems that can be done by the DEI equation proposed by Chapman, bu...In the first part of this article a more general DEI equation was derived using simple concepts. Not only does the new DEI equation explain all the problems that can be done by the DEI equation proposed by Chapman, but also explains the problem that can not be explained with the old DEI equation, such as the noise background caused by the small angle scattering reflected by the analyzer. In the second part, a DEI-PI-CT formula has been proposed and the contour contrast caused by the extinction of refraction beam has been qualitatively explained, and then based on the work of Ando's group two formulae of refraction CT with DEI method has been proposed. Combining one refraction CT formula proposed by Dilmanian with the two refraction CT formulae proposed by us, the whole framework of CT algorithm can be made to reconstruct three components of the gradient of refractive index.展开更多
Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of hu...Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroids and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method.展开更多
X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low- Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) ite...X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low- Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging (DEI-CT). An Ordered Subsets (OS) technique is used to accelerate the ART reconstruction. Few-view reconstruction is also studied, and a partial differential equation (PDE) type filter which has the ability of edge-preserving and denoising is used to improve the image quality and eliminate the artifacts. The proposed algorithm is validated with both the numerical simulations and the experiment at the Beijing synchrotron radiation facility (BSRF).展开更多
Neovascularization is correlative with many processes of diseases, especially for tumor growth, invasion, and metastasis. What is more, these tumor microvessels are totally different from normal vessels in morphology....Neovascularization is correlative with many processes of diseases, especially for tumor growth, invasion, and metastasis. What is more, these tumor microvessels are totally different from normal vessels in morphology. Therefore, observation of the morphologic distribution of microvessels is one of the key points for many researchers in the field. Using diffraction enhanced imaging (DEI), we observed the mirocvessles with diameter of about 40 μm in mouse liver. Moreover, the refraction image obtained from DEI shows higher image contrast and exhibits potential use for medical applications.展开更多
X-ray diffraction sorbing low-Z sample. How enhanced imaging (DEI) is applied to extract phase information from to inspect internal structures of weakly abraw images measured in different positions of rocking curve ...X-ray diffraction sorbing low-Z sample. How enhanced imaging (DEI) is applied to extract phase information from to inspect internal structures of weakly abraw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is compared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method.展开更多
Different configurations for the monochroma-tor crystals and the analyzer crystals have been used in hard X-ray diffraction enhanced imaging (DEI) methods to over-come the complex task to adjust each of them to the id...Different configurations for the monochroma-tor crystals and the analyzer crystals have been used in hard X-ray diffraction enhanced imaging (DEI) methods to over-come the complex task to adjust each of them to the ideal position. Here we present a very compact DEI configuration, and preliminary results of experiments performed at the Beijing Synchrotron Radiation Facility (BSRF) using only two crystals: the first one acting as monochromator and the second one as analyzer in the Bragg geometry. Refraction contrast images characterized by high contrast and spatial resolution are obtained and compared with absorption im-ages. Differences among these images will be outlined and discussed emphasizing the potential capabilities of this very simple layout that guarantees a high transmission efficiency.展开更多
作为 X 射线相衬成像的方法之一,衍射增强成像方法由于能获得较高的信噪比及分辨率而引起了人们的研究兴趣。北京同步辐射装置(BSRF)形貌学实验站也开展了该方法的探索研究。此前的衍射增强成像方法中,当白光 X 射线光束横截面尺寸为 20...作为 X 射线相衬成像的方法之一,衍射增强成像方法由于能获得较高的信噪比及分辨率而引起了人们的研究兴趣。北京同步辐射装置(BSRF)形貌学实验站也开展了该方法的探索研究。此前的衍射增强成像方法中,当白光 X 射线光束横截面尺寸为 20 mm×10 mm 时,经过双晶单色器后最大只能获得横截面尺寸为20 mm×4 mm 的均匀单色 X 射线,从而造成成像区域减小。在对通常衍射增强成像光路排列分析的基础上,提出了一种新的光学排列几何并进行了衍射增强实验。应用新光学排列几何首次获得了与入射白光 X 射线尺寸相当的、大的成像光斑均匀区域,因而新光学排列几何更适合于大尺寸样品的研究工作。同时,该光学排列几何成像分辨率可以达到微米量级并且更方便于实验操作。展开更多
基金Supported by the National Outstanding Youth Fund (10125523 to Z.Wu.)the Key Important Nano-Research Project (90206032)+1 种基金the Key Important Project of the National Natural Science Foundation of China (10490190,10490194) by Knowledge Innovation Fund of IHEP.
文摘In the first part of this article a more general DEI equation was derived using simple concepts. Not only does the new DEI equation explain all the problems that can be done by the DEI equation proposed by Chapman, but also explains the problem that can not be explained with the old DEI equation, such as the noise background caused by the small angle scattering reflected by the analyzer. In the second part, a DEI-PI-CT formula has been proposed and the contour contrast caused by the extinction of refraction beam has been qualitatively explained, and then based on the work of Ando's group two formulae of refraction CT with DEI method has been proposed. Combining one refraction CT formula proposed by Dilmanian with the two refraction CT formulae proposed by us, the whole framework of CT algorithm can be made to reconstruct three components of the gradient of refractive index.
基金Supported by National Natural Science Foundation (10490195)Key Project of Chinese National Programs for Fundamental Research and Development (973 program) (2006cb500700)Natural Science and Technology Foundation of Guangdong Province(04009356,2008B030301320)
文摘Diffraction enhanced imaging (DEI) with edge enhancement is suitable for the observation of weakly absorbing objects. The potential ability of the DEI was explored for displaying the microanatomy and pathology of human eyeball in this work. The images of surgical specimens from malignant intraocular tumor of hospitalized patients were taken using the hard X-rays from the topography station of Beamline 4W1A at Beijing Synchrotron Radiation Facility (BSRF). The obtained radiographic images were analyzed in correlation with those of pathology. The results show that the anatomic and pathologic details of intraocular tumors in human beings can be observed clearly by DEI for the first time, with good visualization of the microscopic details of eyeball ring such as sclera, choroids and other details of intraocular organelles. And the best resolution of DEI images reaches up to the magnitude of several tens of μm. The results suggest that it is capable of exhibiting clearly the details of intraocular tumor using DEI method.
基金Supported by National Natural Science Foundation of China (10875066)Program for New Century Excellent Talents in University (NCET-05-0060)
文摘X-ray diffraction enhanced imaging (DEI) has extremely high sensitivity for weakly absorbing low- Z samples in medical and biological fields. In this paper, we propose an Algebra Reconstruction Technique (ART) iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging (DEI-CT). An Ordered Subsets (OS) technique is used to accelerate the ART reconstruction. Few-view reconstruction is also studied, and a partial differential equation (PDE) type filter which has the ability of edge-preserving and denoising is used to improve the image quality and eliminate the artifacts. The proposed algorithm is validated with both the numerical simulations and the experiment at the Beijing synchrotron radiation facility (BSRF).
基金Supported by National Natural Science Foundation of China (30471652)
文摘Neovascularization is correlative with many processes of diseases, especially for tumor growth, invasion, and metastasis. What is more, these tumor microvessels are totally different from normal vessels in morphology. Therefore, observation of the morphologic distribution of microvessels is one of the key points for many researchers in the field. Using diffraction enhanced imaging (DEI), we observed the mirocvessles with diameter of about 40 μm in mouse liver. Moreover, the refraction image obtained from DEI shows higher image contrast and exhibits potential use for medical applications.
基金Supported by National Natural Science Foundation of China (10875066, 30770618)Program for New Century Excellent Talents in University (NCET-05-0060)
文摘X-ray diffraction sorbing low-Z sample. How enhanced imaging (DEI) is applied to extract phase information from to inspect internal structures of weakly abraw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is compared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method.
文摘Different configurations for the monochroma-tor crystals and the analyzer crystals have been used in hard X-ray diffraction enhanced imaging (DEI) methods to over-come the complex task to adjust each of them to the ideal position. Here we present a very compact DEI configuration, and preliminary results of experiments performed at the Beijing Synchrotron Radiation Facility (BSRF) using only two crystals: the first one acting as monochromator and the second one as analyzer in the Bragg geometry. Refraction contrast images characterized by high contrast and spatial resolution are obtained and compared with absorption im-ages. Differences among these images will be outlined and discussed emphasizing the potential capabilities of this very simple layout that guarantees a high transmission efficiency.
文摘作为 X 射线相衬成像的方法之一,衍射增强成像方法由于能获得较高的信噪比及分辨率而引起了人们的研究兴趣。北京同步辐射装置(BSRF)形貌学实验站也开展了该方法的探索研究。此前的衍射增强成像方法中,当白光 X 射线光束横截面尺寸为 20 mm×10 mm 时,经过双晶单色器后最大只能获得横截面尺寸为20 mm×4 mm 的均匀单色 X 射线,从而造成成像区域减小。在对通常衍射增强成像光路排列分析的基础上,提出了一种新的光学排列几何并进行了衍射增强实验。应用新光学排列几何首次获得了与入射白光 X 射线尺寸相当的、大的成像光斑均匀区域,因而新光学排列几何更适合于大尺寸样品的研究工作。同时,该光学排列几何成像分辨率可以达到微米量级并且更方便于实验操作。