期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Electrochemically Reduced Graphene Oxide as Modified Electrode Material for Determination of Dihydroxybenzenes 被引量:1
1
作者 王梦梦 李曦 +4 位作者 LIU Jing XU Wenjing DONG Yulin LIU Peng 张超灿 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2017年第5期1220-1224,共5页
A simple and green method was introduced to fabricate the electrochemical sensor based on the electrochemically reduced graphene oxide(ERGO) modified electrode. It was found that the ERGO modified electrode exhibite... A simple and green method was introduced to fabricate the electrochemical sensor based on the electrochemically reduced graphene oxide(ERGO) modified electrode. It was found that the ERGO modified electrode exhibited an excellent catalytic activity toward the oxidation of dihydroxybenzenes isomers. Under the optimum conditions, in the simultaneous determination of the dihydroxybenzene isomers, the currents were linear with the concentrations of the isomers from 5 to 550 μmol/L for hydroquinone(HQ), from 6 to 400 μmol/L for catechol(CT) and from 5 to 350 μmol/L for resorcinol(RS), respectively. In addition, the proposed sensor has good stability and reproducibility. The developed method has been applied to the simultaneous determination of dihydroxybenzene isomers in real samples with a satisfactory recovery from 98% to 103%. 展开更多
关键词 graphene electrochemical reduction dihydroxybenzene simultaneous determination
下载PDF
Simultaneous determination of dihydroxybenzene isomers utilizing a thiadiazole film electrode 被引量:1
2
作者 Chang-Zhi Zhao Jun-Yu Liang +1 位作者 Xiao-Lei Gu Hui Liu 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第2期370-374,共5页
The present study reports a sensitive electro-analytical method for the simultaneous determination of dihydroxybenzene isomers by using a thiadiazole film electrode, which was readily prepared by electropolymerization... The present study reports a sensitive electro-analytical method for the simultaneous determination of dihydroxybenzene isomers by using a thiadiazole film electrode, which was readily prepared by electropolymerization of 2,5-dimercapto-1,3,4-thiadiazole on a glassy carbon electrode with cyclic voltammetry. The functionalized electrode has a distinguishable and sensitive response to dihydroxybenzene isomers. Under the optimized conditions, the linear stripping peak currents showed good linear relationships with hydroquinone, catechol and resorcinol at concentration ranges 0.50-120, 0.50-110 and 1.00-110 μmol/L, and the detection limits are 0.1, 0.1 and 0.3 μmol/L, respectively. The proposed method is applicable to the simultaneous determination of dihydroxybenzene isomers in real samples with the relative standard deviations of less than 5.7% and the recovery rates of 95.6%-106%. The constructed electrode is characterized by simple preparation, good selectivity, and high sensitivity advantages. 展开更多
关键词 Electrochemical analysis dihydroxybenzene isomers 2 5-DIMERCAPTO-1 3 4-THIADIAZOLE Elect ropolymerization
原文传递
上一页 1 下一页 到第