A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo...A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.展开更多
The diode infrared focal plane array uses the silicon diodes as a sensitive device for infrared signal measurement. By the infrared radiation, the infrared focal plane can produces small voltage signals. For the tradi...The diode infrared focal plane array uses the silicon diodes as a sensitive device for infrared signal measurement. By the infrared radiation, the infrared focal plane can produces small voltage signals. For the traditional readout circuit structures are designed to process current signals, they cannot be applied to it. In this paper, a new readout circuit for the diode un-cooled infrared focal plane array is developed. The principle of detector array signal readout and small signal amplification is given in detail. The readout circuit is designed and simulated by using the Central Semiconductor Manufacturing Corporation (CSMC) 0.5 μm complementary metal-oxide-semiconductor transistor (CMOS) technology library. Cadence Spectre simulation results show that the scheme can be applied to the CMOS readout integrated circuit (ROIC) with a larger array, such as 320×240 size array.展开更多
A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consis...A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other.展开更多
Microwave-assisted extraction(MAE)was used for extraction of effective components of sarcandra glabra(Thunb.),and then chromatographic fingerprint of sarcandra glabra(Thunb.)was studied by high performance liquid chro...Microwave-assisted extraction(MAE)was used for extraction of effective components of sarcandra glabra(Thunb.),and then chromatographic fingerprint of sarcandra glabra(Thunb.)was studied by high performance liquid chromatography/diode array detector(HPLC/DAD).The conditions of MAE were optimized by an orthogonal experiment,and then the authentication and validation of the chromatographic fingerprint were conducted.Nine peaks were identified as common peaks in the fingerprint chromatograms,and isofraxidin was considered as a reference compound and quantified.Relative standard deviations of retention time and peak area of each component were less than 3% and 8%,respectively.Similarity and difference analysis were conducted by use of PCA and relation coefficient.Twenty batches of sarcandra glabra(Thunb.)samples from two different producing areas could be classified into two different groups in the PCA model.The results showed that MAE-HPLC/DAD method was simple,efficient and stable for the study of complex chromatographic fingerprint of sarcandra glabra(Thunb.),which could provide more reliable and precise information for quality evaluation.展开更多
文摘A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.
基金supported by the Fundamental Research Funds for the Central Universities under Grant No. 2009JBM001
文摘The diode infrared focal plane array uses the silicon diodes as a sensitive device for infrared signal measurement. By the infrared radiation, the infrared focal plane can produces small voltage signals. For the traditional readout circuit structures are designed to process current signals, they cannot be applied to it. In this paper, a new readout circuit for the diode un-cooled infrared focal plane array is developed. The principle of detector array signal readout and small signal amplification is given in detail. The readout circuit is designed and simulated by using the Central Semiconductor Manufacturing Corporation (CSMC) 0.5 μm complementary metal-oxide-semiconductor transistor (CMOS) technology library. Cadence Spectre simulation results show that the scheme can be applied to the CMOS readout integrated circuit (ROIC) with a larger array, such as 320×240 size array.
文摘A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other.
基金supported the National Natural Science Foundation of China(Nos.20375050 and 20905080)National Key Technologies R&D Program of the 11th-five-year Plan(No.2006BAK03A08)Guangdong Provincial Department of Science and Technology(No.2009B010900021)
文摘Microwave-assisted extraction(MAE)was used for extraction of effective components of sarcandra glabra(Thunb.),and then chromatographic fingerprint of sarcandra glabra(Thunb.)was studied by high performance liquid chromatography/diode array detector(HPLC/DAD).The conditions of MAE were optimized by an orthogonal experiment,and then the authentication and validation of the chromatographic fingerprint were conducted.Nine peaks were identified as common peaks in the fingerprint chromatograms,and isofraxidin was considered as a reference compound and quantified.Relative standard deviations of retention time and peak area of each component were less than 3% and 8%,respectively.Similarity and difference analysis were conducted by use of PCA and relation coefficient.Twenty batches of sarcandra glabra(Thunb.)samples from two different producing areas could be classified into two different groups in the PCA model.The results showed that MAE-HPLC/DAD method was simple,efficient and stable for the study of complex chromatographic fingerprint of sarcandra glabra(Thunb.),which could provide more reliable and precise information for quality evaluation.