Influence of thermal flow field of cooling tower on recirculation ratio of a direct air-cooled system for a power plant
1
作者 Zhao Wanli Liu Peiqing 《Engineering Sciences》 EI 2008年第4期64-70,共7页
In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get the... In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get thermal flow field of a ACC under different conditions in low velocity wind tunnel,at the same time,the recirculation ratio at cooling tower was measured,so the relationship between flow field characteristics and recirculation ratio of cooling tower can be discussed. From the results we can see that the flow field configuration around cooling tower has great effects on average recirculation ratio under cooling tower. The eddy formed around cooling tower is a key reason that recirculation produces. The eddy intensity relates to velocity magnitude and direction angle,and the configuration of eddy lies on the geometry size of cooling tower. So changing the flow field configuration around cooling tower reasonably can decrease recirculation ratio under cooling tower,and heat dispel effect of ACC can also be improved. 展开更多
关键词 direct air-cooled condenser thermal flow field characteristics recirculation ratio PIV experiment
下载PDF
The Experimental Investigation of Recirculation of Air-Cooled System for a Large Power Plant
2
作者 Wanli Zhao Qiyue Wang Peiqing Liu 《Energy and Power Engineering》 2010年第4期291-297,共7页
The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV... The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also. 展开更多
关键词 direct air-cooled condenser Thermal Flow Field Recirculation PIV EXPERIMENT Power PLANT
下载PDF
Measures against the adverse impact of natural wind on air-cooled condensers in power plant 被引量:22
3
作者 YANG LiJun,DU XiaoZe & YANG YongPing Key Laboratory of Condition Monitoring and Control for Power Plant Equipment of Ministry of Education of China,North China Electric Power University,Beijing 102206,China 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第5期1320-1327,共8页
The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant.It is of use to take various measures against the adverse effect of wind for the performance improvement of a... The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant.It is of use to take various measures against the adverse effect of wind for the performance improvement of air-cooled condensers.Based on representative 2×600 MW direct air-cooled power plant,three ways that can arrange and optimize the flow field of cooling air thus enhance the heat transfer of air-cooled condensers were proposed.The physical and mathematical models of air-cooled condensers with various flow leading measures were presented and the flow and temperature fields of cooling air were obtained by CFD simulation.The back pressures of turbine were calculated for different measures on the basis of the heat transfer model of air-cooled condensers.The results show that the performance of air-cooled condensers is improved thus the back pressure of turbine is lowered to some extent by taking measures against the adverse impact of natural wind. 展开更多
关键词 air-cooled condenser WIND SPEED and direction flow and HEAT TRANSFER BACK pressure power plant
原文传递
Influences of Lateral Double-Layered Deflectors on Cooling Performance of Air-Cooled Condenser 被引量:3
4
作者 HUANG Wenhui HUANG Xianwei +1 位作者 YANG Lijun DU Xiaoze 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第6期2164-2177,共14页
The cooling performance of air-cooled condenser(ACC)is susceptible to adverse impacts of ambient winds.In this work,three kinds of lateral double-layered deflectors installed under the ACC platform are proposed to wea... The cooling performance of air-cooled condenser(ACC)is susceptible to adverse impacts of ambient winds.In this work,three kinds of lateral double-layered deflectors installed under the ACC platform are proposed to weaken the unfavorable effects of cross winds.Through CFD simulation methods,the main parameters of thermo-flow performances of a 2×660 MW direct dry cooling system are obtained,by which it can be concluded that the deflectors can effectively reduce the inlet air temperatures while enhance the mass flow rates of upwind fans due to the guiding effect,especially at high wind speeds,while the improvement of cooling capacity of ACCs in the 0°wind direction is weak.The inclined-vertical deflectors are superior to others in performance improvement of ACCs for all cases,which can reduce the turbine back pressure by 12.15%when the wind speed is 12 m/s,so they can be applied to the performance enhancement of ACCs under windy conditions in practical engineering. 展开更多
关键词 air-cooled condenser lateral double-layered deflectors cooling capacity turbine back pressure wind speed and direction
原文传递
大型直接空冷电站的设计和运行情况 被引量:15
5
作者 谢滨 雷平和 《电力设备》 2006年第3期8-13,共6页
针对大同第二发电厂二期工程2×600MW直接空冷电站设计经验,对空冷汽轮机技术条件、空冷系统容量、风机群噪声、大风对空冷系统的影响等问题提出意见。如:留出足够的安全运行背压余量,尽量避免机组跳闸现象的发生;对汽轮机汽封设计... 针对大同第二发电厂二期工程2×600MW直接空冷电站设计经验,对空冷汽轮机技术条件、空冷系统容量、风机群噪声、大风对空冷系统的影响等问题提出意见。如:留出足够的安全运行背压余量,尽量避免机组跳闸现象的发生;对汽轮机汽封设计及汽封加热器容量应给以足够的重视;空冷机组负荷调度应符合空冷系统运行的特点。文章最后分析了汽轮发电机基座和空冷平台支撑结构安装的技术问题,目前,已开展小柱距全钢结构空冷平台的研究和应用,以降低造价,减轻施工难度。 展开更多
关键词 直接空冷 空冷凝汽器 汽轮机 设计 发电厂
下载PDF
火电厂300MW机组直接空冷系统的控制与运行
6
作者 田振宇 刘卫东 国建刚 《信息技术》 2009年第12期88-91,共4页
在分析了火电厂直接空冷系统的工艺过程和功能特点的基础上,介绍了基于DCS控制的300MW机组直接空冷控制系统的组成、测点布置及控制功能,并对系统的启动准备、启动运行、正常运行、低负荷运行、关闭运行、非正常运行、紧急运行等工况进... 在分析了火电厂直接空冷系统的工艺过程和功能特点的基础上,介绍了基于DCS控制的300MW机组直接空冷控制系统的组成、测点布置及控制功能,并对系统的启动准备、启动运行、正常运行、低负荷运行、关闭运行、非正常运行、紧急运行等工况进行了详细分析,实际运行结果表明直接空冷冬季防冻措施灵活可靠,直接空冷可通过改变风机转速或停运风机或使风机反转来调节空冷凝汽器的进风量或直至吸热风来防止空冷凝汽器冻结,调节相对灵活,效果良好。 展开更多
关键词 直接空冷 空冷凝汽器 acc 控制系统 DCS
下载PDF
国产660MW超临界直接空冷机组甩负荷试验分析
7
作者 杜建桥 曲海云 +1 位作者 唐广通 李路江 《河北电力技术》 2011年第5期21-24,共4页
分析某电厂660MW超临界直接空冷机组甩负荷试验实例,介绍试验前的必备条件和必要操作,甩负荷试验过程中的具体时间控制和各参数变化情况,提出保证甩负荷试验成功的操作要点,供同类型机组甩负荷试验借鉴和参考。
关键词 超临界 直接空冷机组 甩负荷试验 操作要点
下载PDF
1 000 MW直接空冷发电机组凝汽器传热性能试验研究 被引量:10
8
作者 张兆营 杨建国 郑立军 《中国电机工程学报》 EI CSCD 北大核心 2014年第20期3317-3323,共7页
不同工况下空冷凝汽器的换热性能,是火电直接空冷机组设计、优化和运行的主要依据。针对实际运行的1 000 MW超超临界直接空冷机组,对其凝汽器进行了夏季、冬季和秋季工况的试验研究。试验获得了夏季和冬季工况下凝汽器翅片管束迎面风速... 不同工况下空冷凝汽器的换热性能,是火电直接空冷机组设计、优化和运行的主要依据。针对实际运行的1 000 MW超超临界直接空冷机组,对其凝汽器进行了夏季、冬季和秋季工况的试验研究。试验获得了夏季和冬季工况下凝汽器翅片管束迎面风速的分布和壁面温度的分布,发现翅片管束迎面风速分布从上至下逐渐增高,而管束壁面温度分布对于顺流单元从上至下逐渐降低,对于逆流单元从上至下逐渐增高;获得了顺流翅片管束的易结冻区域;获得了秋季工况下1 000 MW空冷机组空冷凝汽器空气侧努赛尔数和雷诺数之间的无量纲关联式。 展开更多
关键词 1 000 MW超超临界机组 直接空冷电厂 空冷凝汽器 管壁温度分布 迎面风速分布 冻结 试验关联式
下载PDF
国产化直接空冷机组风机研究
9
作者 赵华阳 崔野 +1 位作者 周轶 许程 《科技传播》 2012年第4期159-161,共3页
以国产化直接空冷机组风机为研究对象,分析了风机的选型、性能试验和运行特性。同时选取机组的典型工况点,分析了风机电耗-机组发电功率净收益曲线,确定了机组的最佳运行工况点。并提出了风机运行过程中存在的问题及解决措施,有利于空... 以国产化直接空冷机组风机为研究对象,分析了风机的选型、性能试验和运行特性。同时选取机组的典型工况点,分析了风机电耗-机组发电功率净收益曲线,确定了机组的最佳运行工况点。并提出了风机运行过程中存在的问题及解决措施,有利于空冷机组及风机的经济稳定运行。 展开更多
关键词 直接空冷机组 风机 特性 运行
下载PDF
直接空冷闭环控制系统的应用和探讨
10
作者 朱军 高永亮 《华北电力技术》 CAS 2006年第A01期13-15,共3页
对漳山发电直接空冷控制系统控制、保护逻辑进行全面介绍,针对在实际运行中存在的问题,提出了相应的改进方案。
关键词 直接空冷凝汽器 变频调节 acc保护
下载PDF
燃机联合循环机组直接空冷凝气器选型优化
11
作者 邱永罡 《华电技术》 CAS 2018年第5期13-16,共4页
根据传热学基本原理,建立空冷器初始温差(ITD)和迎面风速对直接空冷凝汽器(ACC)换热面积和耗电量的影响的数学模型。以某F级一拖一联合循环项目直接空冷机组为例,计算不同的ITD和迎面风速对于电厂净出力和空冷凝汽器换热面积的影响,从... 根据传热学基本原理,建立空冷器初始温差(ITD)和迎面风速对直接空冷凝汽器(ACC)换热面积和耗电量的影响的数学模型。以某F级一拖一联合循环项目直接空冷机组为例,计算不同的ITD和迎面风速对于电厂净出力和空冷凝汽器换热面积的影响,从而获得最佳的空冷凝汽器选型参数。 展开更多
关键词 直接空冷凝汽器 传热系数 迎面风速 ITD 换热面积 净出力 acc耗电量
下载PDF
环境风作用下2×1000MW直接空冷机组空冷岛布局 被引量:11
12
作者 肖烈晖 杜小泽 +1 位作者 杨立军 席新铭 《电力建设》 北大核心 2015年第6期7-13,共7页
单机容量达到百万k W的直接空冷火电机组空冷岛具有庞大的体积和更多的空冷单元,环境风导致的系统性能空间分布不均匀性更为明显。空冷岛的结构与布局优化,为百万k W空冷机组应对环境风不利影响提供了可行的技术途径。针对2×1 000... 单机容量达到百万k W的直接空冷火电机组空冷岛具有庞大的体积和更多的空冷单元,环境风导致的系统性能空间分布不均匀性更为明显。空冷岛的结构与布局优化,为百万k W空冷机组应对环境风不利影响提供了可行的技术途径。针对2×1 000 MW直接空冷机组,建立物理数学模型,考虑环境自然风和空冷单元轴流风机输运空气流的耦合作用,采用数值模拟方法,获得空气侧流场和温度场的三维分布。特别针对实际运行中最为不利的锅炉后来风,在不同风速,以及空冷岛和主厂房不同距离条件下,从机理上解释空冷岛冷却通风流量和换热性能的变化规律。结果表明:随着环境风速增加,空冷岛的换热能力降低;距离增大,随风速增加换热性能恶化的趋势更为显著;环境风速大于6 m/s时,距离越大,热风回流率越高;相比于其他更大距离的布置方式,距离15 m布置方式流动换热性能更好;环境风速较大的情况下,紧密的空冷电站建筑布局,更有利于抵御大风的不利影响。 展开更多
关键词 直接空冷 空冷岛 流动传热特性 距离 热风回流率
原文传递
Study on heat transfer enhancement of discontinuous short wave finned flat tube 被引量:4
13
作者 FENG LiLi DU XlaoZe +1 位作者 YANG YongPing YANG LiJun 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第12期3281-3288,共8页
The typical configuration adopted by air-cooled condenser(ACC) in coal-fired power generating unit is the wave finned flat tube. The development of boundary layer between wave fins along long axis of flat tube can sup... The typical configuration adopted by air-cooled condenser(ACC) in coal-fired power generating unit is the wave finned flat tube. The development of boundary layer between wave fins along long axis of flat tube can suppress the air-side heat transfer enhancement to a great extent. It has been proved that the serrated fins can enhance heat transfer obviously by breaking the development of boundary layer periodically. In the present study,the discontinuous short wave fin was introduced to the flat tube to enhance the air-side heat transfer of ACC. Two different types of arrangements,i.e. staggered and in-line for discontinuous short wave fins on the flat tube,were designed. By numerical simulation,the heat transfer and flow performances of short wave fins were studied under different arrangements(in-line,staggered) ,and the influences on heat transfer and flow characteristics of rows of short wave fin and interrupted distance between discontinuous short wave fins were revealed numerically. The results indicated that,compared with the original continuous wave fin,the discontinuous short wave fin effectively improved the air-side heat transfer of flat tube under the air flow velocities in the practical application of engineering. Moreover,the increment of pressure loss of air-side flow was restricted for the discontinuous short wave fins because of the reduction of contact areas between the air flow and fin surface. 展开更多
关键词 fiat tube discontinuous short fin heat transfer enhancement direct air-cooled condenser