The photocatalytic activity of CdS can be greatly improved by co-modification of NiS and TiO_2 materials; furthermore the order of connection affects much. A directional electron transfer route via CdS → TiO_2→ NiS ...The photocatalytic activity of CdS can be greatly improved by co-modification of NiS and TiO_2 materials; furthermore the order of connection affects much. A directional electron transfer route via CdS → TiO_2→ NiS is found crucial to the enhancement of ternary catalyst, where TiO_2 acts as an electron reservoir and Ni S works as an effective cocatalyst. Cd S/TiO_2@Ni S with Ni S loaded on TiO_2 has an activity of H_2 evolution 2.5 times higher than NiS@Cd S/TiO_2 with Ni S pre-loaded on Cd S. Faster e-/h+separation rates is obtained of Cd S/TiO_2@Ni S under visible light than under extra UV light irradiation, which in turn demonstrates the importance of directional electron transfer route.展开更多
Functionalized nano-PbS has been prepared and characterized. The functionalized nanoparticles have good dispersibility in water. Reaction of functionalized nanoPbS with gglobulin (gIgG) results an enhanced resonance...Functionalized nano-PbS has been prepared and characterized. The functionalized nanoparticles have good dispersibility in water. Reaction of functionalized nanoPbS with gglobulin (gIgG) results an enhanced resonance light scattering (RLS) around 385 nm. However, when the content of HSA is lower than 0.5 mg ml-1 the RLS enhancement is very weak and is nonlinear to concentration of HSA. Based on these results, a new direct quantitative determination method for gglobulin in blood serum samples without separation is established. Under optimal conditions, the enhanced RLS intensity is in proportion to the gIgG concentration in the range 10500 ng/mL. The limit of detection is 2.75 ng/mL. This method is proved to be very sensitive, rapid, simple and selective for detection of gIgG in blood serum.展开更多
This paper proposes a novel indoor positioning scheme based on visible light communication(VLC).A new indoor VLC positioning scheme using fingerprint database with multi-parameters have been raised.We conduct simulati...This paper proposes a novel indoor positioning scheme based on visible light communication(VLC).A new indoor VLC positioning scheme using fingerprint database with multi-parameters have been raised.We conduct simulation and experimental research on the illumination intensity distribution of several direction parameters.In the experiment,four LED matrixes are identified by LED-ID with room dimensions of 3.75×4.00×2.7 m^3.The results show that the mean of the location error is 0.22 m in the receiving plane,verifying the correctness and feasibility of the positioning scheme.展开更多
基金Supported by the Scientific Research Starting Foundation for Doctors(trxyD H1512)the Foundation for Youth Talent Growth Project in the Ministry of Science and Technology of China(20171184)the Mutual Foundation in the Ministry of Science and Technology of China(20177315)
文摘The photocatalytic activity of CdS can be greatly improved by co-modification of NiS and TiO_2 materials; furthermore the order of connection affects much. A directional electron transfer route via CdS → TiO_2→ NiS is found crucial to the enhancement of ternary catalyst, where TiO_2 acts as an electron reservoir and Ni S works as an effective cocatalyst. Cd S/TiO_2@Ni S with Ni S loaded on TiO_2 has an activity of H_2 evolution 2.5 times higher than NiS@Cd S/TiO_2 with Ni S pre-loaded on Cd S. Faster e-/h+separation rates is obtained of Cd S/TiO_2@Ni S under visible light than under extra UV light irradiation, which in turn demonstrates the importance of directional electron transfer route.
文摘Functionalized nano-PbS has been prepared and characterized. The functionalized nanoparticles have good dispersibility in water. Reaction of functionalized nanoPbS with gglobulin (gIgG) results an enhanced resonance light scattering (RLS) around 385 nm. However, when the content of HSA is lower than 0.5 mg ml-1 the RLS enhancement is very weak and is nonlinear to concentration of HSA. Based on these results, a new direct quantitative determination method for gglobulin in blood serum samples without separation is established. Under optimal conditions, the enhanced RLS intensity is in proportion to the gIgG concentration in the range 10500 ng/mL. The limit of detection is 2.75 ng/mL. This method is proved to be very sensitive, rapid, simple and selective for detection of gIgG in blood serum.
基金supported by ZTE Industry-Academia-Research Cooperation Funds under Grant No.2014ZTE02-12
文摘This paper proposes a novel indoor positioning scheme based on visible light communication(VLC).A new indoor VLC positioning scheme using fingerprint database with multi-parameters have been raised.We conduct simulation and experimental research on the illumination intensity distribution of several direction parameters.In the experiment,four LED matrixes are identified by LED-ID with room dimensions of 3.75×4.00×2.7 m^3.The results show that the mean of the location error is 0.22 m in the receiving plane,verifying the correctness and feasibility of the positioning scheme.