期刊文献+
共找到24篇文章
< 1 2 >
每页显示 20 50 100
Design of small-area and high-efficiency DC-DC converter for 1 T SRAM
1
作者 LEE Jae-hyung 金丽妍 +4 位作者 余忆宁 JANG Ji-hye KIM Kwang-il HA Pan-bong KIM Young-hee 《Journal of Central South University》 SCIE EI CAS 2012年第2期417-423,共7页
The direct current-direct current (DC-DC) converter is designed for 1 T static random access memory (SRAM) used in display driver integrated circuits (ICs), which consists of positive word-line voltage (VpwL),... The direct current-direct current (DC-DC) converter is designed for 1 T static random access memory (SRAM) used in display driver integrated circuits (ICs), which consists of positive word-line voltage (VpwL), negative word-line voltage (VinyL) and half-VDD voltage (VHDo) generator. To generate a process voltage temperature (PVT)-insensitive VpWL and VNWL, a set of circuits were proposed to generate reference voltages using bandgap reference current generators for respective voltage level detectors. Also, a VOWL regulator and a VNWL charge pump were proposed for a small-area and low-power design. The proposed VpwL regulator can provide a large driving current with a small area since it regulates an input voltage (VCI) from 2.5 to 3.3 V. The VmvL charge pump can be implemented as a high-efficiency circuit with a small area and low power since it can transfer pumped charges to VNWL node entirely. The DC-DC converter for 1 T SRAM were designed with 0.11 μm mixed signal process and operated well with satisfactory measurement results. 展开更多
关键词 1 T-static random access memory direct current-direct current converter positive word-line voltage negative word-line voltage half- VDb generator
下载PDF
高压直流换流站穿墙套管的局部放电在线测量(英文) 被引量:8
2
作者 Nathan D.Jacob William M.McDermid Behzad Kordi 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2636-2642,共7页
An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insul... An online partial discharge(PD) measurement performed on a high voltage direct current(HVDC) wall bushing successfully identified the presence of internal discharges.The wall bushing is a sulfur hexafluoride gas-insulated bushing,rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge.The measurement of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment.An additional challenge is the""mixed"voltage stress on the bushing insulation,which has both ac and dc high-voltage components.There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation.As a result,the analysis and interpretation of PD data for HVDC equipment is more complex;PD pulses may occur in response to the ac,dc,or switching transient voltage stresses.In this paper,an online PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed.The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients,caused during switching,trigger some PD events.Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities.The findings from the online PD measurements are verified with physical evidence,found after the bushing was removed from service,suggested internal PD had occurred inside the bushing. 展开更多
关键词 partial discharge(PD) electrical insulation high voltage direct current(HVDC) converters SF6 electromagnetic interference electromagnetic coupling
下载PDF
Four-quadrant Force Control with Minimal Ripple for Linear Switched Reluctance Machines 被引量:5
3
作者 Xuanrui Huang Zechuan Lin Xi Xiao 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第1期27-34,共8页
Linear switch reluctance machine(LSRM)has been tried to act as an alternative generator for direct drive linear wave energy converter(WEC).Many researchers have proposed new topologies of LSRM to improve the power den... Linear switch reluctance machine(LSRM)has been tried to act as an alternative generator for direct drive linear wave energy converter(WEC).Many researchers have proposed new topologies of LSRM to improve the power density,efficiency and reliability.However,the control methods for LSRM applied in direct drive WEC have been paid little attention,especially control methods considering the wave energy generator operating characteristics.In this paper,according to the generator control requirements of the direct drive WEC,force control algorithm for LSRM operating in four quadrants without a speed closed loop is put forward.The force ripple of LSRM is suppressed using force sharing function method.The four-quadrant control is easy to realize requiring only phase currents information.Simulation results validate the proposed method and indicate that LSRM is able to be used as the generator for direct drive WEC. 展开更多
关键词 Linear switched reluctance machine direct drive wave energy converter force ripple suppression four-quadrant operation.
下载PDF
Damping controller design based on FO-PID-EMA in VSC HVDC system to improve stability of hybrid power system 被引量:2
4
作者 Nima SHAFAGHATIAN Arvin KIANI +2 位作者 Naser TAHERI Zahra RAHIMKHANI Seyyed Saeed MASOUMI 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第2期403-417,共15页
Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system... Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller. 展开更多
关键词 hybrid power system high voltage direct current based on voltage source converter(VSC HVDC) fractional order PID(FO-PID)damping controller exchange market algorithm
下载PDF
Single-ended Fault Detection Scheme Using Support Vector Machine for Multi-terminal Direct Current Systems Based on Modular Multilevel Converter
5
作者 Guangyang Zhou Xiahui Zhang +2 位作者 Minxiao Han Shaahin Filizadeh Zhi Geng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第3期990-1000,共11页
This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The sche... This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability. 展开更多
关键词 Fault detection short-circuit fault multi-terminal direct current systems based on modular multilevel converter support vector machine(SVM) wavelet transform
原文传递
Harmonic Transfer Function Based Single-input Single-output Impedance Modeling of LCC-HVDC Systems 被引量:1
6
作者 Yang Wang Fei Xia +1 位作者 Ying Wang Xianyong Xiao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1327-1332,共6页
This study presents a harmonic transfer function(HTF)based single-input single-output(SISO)impedance modeling method.The method converts an HTF from phase domain to sequence domain and then transforms it into an SISO ... This study presents a harmonic transfer function(HTF)based single-input single-output(SISO)impedance modeling method.The method converts an HTF from phase domain to sequence domain and then transforms it into an SISO impedance while preserving the frequency coupling information of different sequences and different harmonics.Applications of this method to a line-commutated converter based high-voltage direct current(LCC-HVDC)system are presented.The results demonstrate the accuracy of the derived SISO impedance,and a truncation-order selection is suggested.The case study shows that the proposed method facilitates simpler impedance measurements and associated stability analysis. 展开更多
关键词 Line-commutated converter based high-voltage direct current(LCC-HVDC) harmonic transfer function(HTF) single-input single-output(SISO)impedance frequency coupling
原文传递
High-frequency Resonance Analysis and Impedance Reshaping Control of MMC-HVDC System Based on Frequency Coupling Impedance Model
7
作者 Juanjuan Wang Wei Chen +3 位作者 Yuekun Liu Chuang Fu Yunming Ye Junjie Feng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期646-657,共12页
In recent years, high-frequency resonance (HFR) events occurred in several modular multilevel converter based high-voltage direct current (MMC-HVDC) projects. The time delay of an MMC-HVDC system is the critical facto... In recent years, high-frequency resonance (HFR) events occurred in several modular multilevel converter based high-voltage direct current (MMC-HVDC) projects. The time delay of an MMC-HVDC system is the critical factor that induces HFR. The frequency coupling affects the impedance characteristics of an MMC and further deteriorates system stability. Therefore, in this paper, a multi-input multi-output admittance model of an MMC-HVDC system is developed to analyze its frequency characteristics. The effects of current loop, power loop, phase-locked loop, and operating point on the MMC frequency coupling degree are analyzed in detail. Meanwhile, to further suppress HFR in the MMC-HVDC system, an enhanced impedance reshaping control strategy based on the equivalent single-input single-output impedance model is proposed. Finally, the accuracy of the enhanced impedance model and the effectiveness of the impedance reshaping control are verified by electromagnetic transient simulations in PSCAD. 展开更多
关键词 Modular multilevel converter based high-voltage direct current(MMC-HVDC) high-frequency resonance frequency coupling impedance model impedance reshaping control
原文传递
Damping Characteristic Analysis and Optimization of Wind-thermal-bundled Power Transmission by LCC-HVDC Systems
8
作者 Liwen Zheng Shiying Ma 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第1期299-312,共14页
With the rapid development of renewable energy,wind-thermal-bundled power transmission by line-commutated converter based high-voltage direct current(LCC-HVDC)systems has been widely developed.The dynamic interaction ... With the rapid development of renewable energy,wind-thermal-bundled power transmission by line-commutated converter based high-voltage direct current(LCC-HVDC)systems has been widely developed.The dynamic interaction mechanisms among permanent magnet synchronous generators(PMSGs),synchronous generators(SGs),and LCC-HVDC system become complex.To deal with this issue,a path analysis method(PAM)is proposed to study the dynamic interaction mechanism,and the damping reconstruction is used to analyze the damping characteristic of the system.First,based on the modular modeling,linearized models for the PMSG subsystem,the LCC-HVDC subsystem,and the SG subsystem are established.Second,based on the closed-loop transfer function diagram of the system,the disturbance transfer path and coupling relationship among subsystems are analyzed by the PAM,and the damping characteristic analysis of the SG-dominated oscillation mode is studied based on the damping reconstruction.Compared with the PAM,the small-signal model of the system is obtained and eigenvalue analysis results are presented.Then,the effect of the control parameters on the damping characteristic is analyzed and the conclusions are verified by time-domain simulations.Finally,the penalty functions of the oscillation modes and decay modes are taken as the objective function,and an optimization strategy based on the Monte Carlo method is proposed to solve the parameter optimization problem.Numerical simulation results are presented to validate the effectiveness of the proposed strategy. 展开更多
关键词 Wind-thermal-bundled power transmission line-commutated converter based high-voltage direct current(LCC-HVDC) path analysis method(PAM) damping characteristic analysis Monte Carlo method
原文传递
Impedance Model for Instability Analysis of LCC-HVDCs Considering Transformer Saturation
9
作者 Qin Jiang Ruiting Xu +4 位作者 Baohong Li Xiang Chen Yue Yin Tianqi Liu Frede Blaabjerg 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1309-1319,共11页
In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power s... In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power system.However,the nonlinear characteristics of the power grids introduced by the transformer saturation considerably limit the application of the conventional analysis methods.To address the issue,this paper derives a linear model for the transformer saturation caused by the DC current due to the converter modulation.Afterwards,the nonlinear characteristics of power grids with the transformer saturation is described by a complex valued impedance matrix.Based on the derived impedance matrix,the system harmonic stability is analyzed and the mechanism of the transformer saturation induced harmonic instability is revealed.Finally,the sensitivity analysis is conducted to find the key factors that influence the system core saturation instability.The proposed impedance model is verified by the electromagnetic transient simulation,and the simulation results corroborate the effectiveness of the proposed impedance model.Index TermsLine commutated converter based high voltage direct current(LCC-HVDC),transformer saturation,harmonic instability,impedance model. 展开更多
关键词 Line commutated converter based high voltage direct current(LCC-HVDC) transformer saturation harmonic instability impedance model
原文传递
R&D and application of voltage sourced converter based high voltage direct current engineering technology in China 被引量:56
10
作者 Guangfu TANG Zhiyuan HE Hui PANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2014年第1期1-15,共15页
As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out... As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out a deep technical research and engineering application in this area,and at present,it has been stepped into a fast growing period.This paper gives a general review over China’s VSC based HVDC in terms of engineering technology,application and future development.It comprehensively analyzes the technical difficulties and future development orientation on the aspects of the main configurations of VSC based HVDC system,topological structures of converters,control and protection technologies,flexible DC cables,converter valve tests,etc.It introduces the applicable fields and current status of China’s VSC based HVDC projects,and analyzes the application trends of VSC based HVDC projects both in China and all over the world according to the development characteristics and demands of future power grids. 展开更多
关键词 Voltage sourced converter based high voltage direct current(VSC based HVDC) Two-level converter Modular multi-level converter(MMC) Direct current grid(DC grid)
原文传递
A DC Chopper Topology to Mitigate Commutation Failure of Line Commutated Converter Based High Voltage Direct Current Transmission 被引量:5
11
作者 Chunyi Guo Bo Liu Chengyong Zhao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第2期345-355,共11页
To reduce the probability of commutation failure(CF)of a line commutated converter based high-voltage direct current(LCC-HVDC)transmission,a DC chopper topology composed of power consumption sub-modules based on thyri... To reduce the probability of commutation failure(CF)of a line commutated converter based high-voltage direct current(LCC-HVDC)transmission,a DC chopper topology composed of power consumption sub-modules based on thyristor full-bridge module(TFB-PCSM)is proposed.Firstly,the mechanism of the proposed topology to mitigate CF is analyzed,and the working modes of TFB-PCSM in different operation states are introduced.Secondly,the coordinated control strategy between the proposed DC chopper and LCC-HVDC is designed,and the voltage-current stresses of the TFB-PCSMs are investigated.Finally,the ability to mitigate the CF issues and the fault recovery performance of LCC-HVDC system are studied in PSCAD/EMTDC.The results show that the probability of CF of LCC-HVDC is significantly reduced,and the performances of fault recovery are effectively improved by the proposed DC chopper. 展开更多
关键词 Line commutated converter based high-voltage direct current(LCC-HVDC)transmission DC chopper power consumption sub-module based on thyristor full-bridge module(TFB-PCSM) commutation failure(CF) fault recovery capability
原文传递
Impact of Different AC Voltage Control Modes of Wind-farm-side MMC on Stability of MMC-HVDC with Offshore Wind Farms 被引量:3
12
作者 Hongfei Lin Tao Xue +1 位作者 Jing Lyu Xu Cai 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1687-1699,共13页
Wind-farm-side modular multilevel converters(WFMMCs) used in modular multilevel converter based highvoltage direct current(MMC-HVDC) transmission systems must be able to control the AC grid voltage in offshore wind fa... Wind-farm-side modular multilevel converters(WFMMCs) used in modular multilevel converter based highvoltage direct current(MMC-HVDC) transmission systems must be able to control the AC grid voltage in offshore wind farms. Different AC voltage control strategies can significantly affect the dynamic characteristics of WFMMCs. However, existing studies have not provided a general methodology of controller parameter design, and few comparative studies have been conducted on control performance under varying operating conditions as well as the effects of different AC voltage control modes(AVCMs) on the stability of MMC-HVDCs with offshore wind farms. This paper provides a controller parameter design method for AVCMs, which is tested in various operating scenarios. Sequence impedance models of offshore wind farms and WFMMCs under different AVCMs are then developed. The effects of AVCMs on the small-signal stability of the interconnected system are then analyzed and compared using the impedance-based method. Finally, case studies are conducted on a practical MMC-HVDC system with offshore wind farms to verify the theoretical analysis. 展开更多
关键词 Offshore wind farm modular multilevel converter based high-voltage direct current(MMC-HVDC) AC voltage control STABILITY dynamic response
原文传递
Small-signal Stability Analysis and Improvement with Phase-shift Phase-locked Loop Based on Back Electromotive Force Observer for VSC-HVDC in Weak Grids 被引量:2
13
作者 Yongqing Meng Haibo Wang +3 位作者 Ziyue Duan Feng Jia Zhengchun Du Xiuli Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第3期980-989,共10页
Voltage source converter based high-voltage direct current(VSC-HVDC)transmission technology has been extensively employed in power systems with a high penetration of renewable energy resources.However,connecting a vol... Voltage source converter based high-voltage direct current(VSC-HVDC)transmission technology has been extensively employed in power systems with a high penetration of renewable energy resources.However,connecting a voltage source converter(VSC)to an AC weak grid may cause the converter system to become unstable.In this paper,a phase-shift phaselocked loop(PS-PLL)is proposed wherein a back electromotive force(BEMF)observer is added to the conventional phaselocked loop(PLL).The BEMF observer is used to observe the voltage of the infinite grid in the stationaryαβframe,which avoids the problem of inaccurate observations of the grid voltage in the dq frame that are caused by the output phase angle errors of the PLL.The VSC using the PS-PLL can operate as if it is facing a strong grid,thus enhancing the stability of the VSC-HVDC system.The proposed PS-PLL only needs to be properly modified on the basis of a traditional PLL,which makes it easy to implement.In addition,because it is difficult to obtain the exact impedance of the grid,the influence of shortcircuit ratio(SCR)estimation errors on the performance of the PS-PLL is also studied.The effectiveness of the proposed PSPLL is verified by the small-signal stability analysis and timedomain simulation. 展开更多
关键词 Phase-locked loop(PLL) small-signal model stability improvement voltage source converter based high-voltage direct current(VSC-HVDC) weak grid
原文传递
A Similarity Comparison Based Pilot Protection Scheme for VSC-HVDC Grids Considering Fault Current Limiting Strategy 被引量:1
14
作者 Keao Chen Jinghan He +3 位作者 Meng Li Yong Tang Ming Nie Chenguang Liang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第4期1305-1315,共11页
In the voltage source converter based high-voltage direct current(VSC-HVDC)grids,fast and reliable protections are the key technologies.The traditional protection schemes are easily affected by fault resistance,line d... In the voltage source converter based high-voltage direct current(VSC-HVDC)grids,fast and reliable protections are the key technologies.The traditional protection schemes are easily affected by fault resistance,line distributed capacitance,etc.Meanwhile,the influence of fault current limiting strategy(FCLS)has not been fully considered.In this paper,the fault characteristics under FCLS and the feasibility of traditional travelling wave protections are analyzed.To improve the reliability and sensibility,a similarity comparison based pilot protection scheme is proposed,which focuses on the relationship between the fault characteristics and the state of the protected transmission line,with the establishment of a precise frequencydependent transmission line model.The criteria based on the similarity comparison calculated by cross-wavelet can identify the fault effectively.Meanwhile,the protection scheme can also endure the influence of error synchronization.Finally,the protection performance is verified in the PSCAD/EMTDC under different fault conditions. 展开更多
关键词 Voltage source converter based high voltage direct current(VSC-HVDC) fault current limiting strategy(FCLS) fault characteristic pilot protection similarity comparison frequency-dependent transmission line model
原文传递
A Comprehensive Power Flow Approach for Multi-terminal VSC-HVDC System Considering Cross-regional Primary Frequency Responses 被引量:12
15
作者 Yida Ye Ying Qiao +1 位作者 Le Xie Zongxiang Lu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第2期238-248,共11页
For the planning,operation and control of multiterminal voltage source converter(VSC)based high-voltage direct current(HVDC)(VSC-MTDC)systems,an accurate power flow formulation is a key starting point.Conventional pow... For the planning,operation and control of multiterminal voltage source converter(VSC)based high-voltage direct current(HVDC)(VSC-MTDC)systems,an accurate power flow formulation is a key starting point.Conventional power flow formulations assume the constant frequencies for all asynchronous AC systems.Therefore,a new feature about the complex coupling relations between AC frequencies,DC voltages and the exchanged power via VSC stations cannot be characterized if VSC-MTDC systems are required to provide cross-regional frequency responses.To address this issue,this paper proposes a comprehensive frequency-dependent power flow formulation.The proposed approach takes the frequencies of asynchronous AC systems as explicit variables,and investigates the novel bus models of the interlinking buses of VSC stations.The proposed approach accommodates different operation modes and frequency droop strategies of VSC stations,and considers the power losses of VSC stations.The effectiveness and generality of the developed approach are validated by a 6-terminal VSC-HVDC test system.The test system presents the characteristics of the coexistence of numerous VSC operation modes,the absence of slack buses in both AC and DC subsystems,and diversified grid configurations such as point-to-point integration of renewable energy sources and one AC system integrated with multiple VSC stations. 展开更多
关键词 Voltage source converter based high-voltage direct current(VSC-HVDC) multi-terminal VSC based HVDC(VSC-MTDC) cross-regional frequency response power flow formulation VSC operation mode
原文传递
A sensorless and simple controller for VSC based HVDC systems 被引量:4
16
作者 E. ABIRI A. RAHMATI A. ABRISHAMIFAR 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2009年第12期1824-1834,共11页
Voltage source converter high-voltage direct current (VSC-HVDC) is a new power transmission technology pref- erable in small or medium power transmission. In this paper we discuss a new control system based on space... Voltage source converter high-voltage direct current (VSC-HVDC) is a new power transmission technology pref- erable in small or medium power transmission. In this paper we discuss a new control system based on space vector modulation (SVM) without any voltage line sensors. Using direct power control (DPC) SVM and a new double synchronous reference frame phase-locked loop (DSRF-PLL) approach, the control system is resistant to the majority of line voltage disturbances. Also, the system response has accelerated by using a feed forward power decoupled loop. The operation of this control strategy was verified in a SIMULINK/MATLAB simulation environment. To validate this control system, a 5 kV.A prototype system was constructed. Compared to the original controllers, the current total harmonic distortion (THD), the active and reactive deviations and the DC voltage overshoot were lowered by 2.5%, 6.2% and 8%, respectively. The rectifier power factor in the worst condition was 0.93 and the DC voltage settling time was 0.2 s. 展开更多
关键词 Voltage source converter high-voltage direct current (VSC-HVDC) Space vector modulation (SVM) Direct power control (DPC) HVDC Light
原文传递
An End-to-end Transient Recognition Method for VSC-HVDC Based on Deep Belief Network 被引量:3
17
作者 Guomin Luo Jiaxin Hei +2 位作者 Changyuan Yao Jinghan He Meng Li 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2020年第6期1070-1079,共10页
Lightning is one of the most common transient interferences on overhead transmission lines of high-voltage direct current(HVDC)systems.Accurate and effective recognition of faults and disturbances caused by lightning ... Lightning is one of the most common transient interferences on overhead transmission lines of high-voltage direct current(HVDC)systems.Accurate and effective recognition of faults and disturbances caused by lightning strokes is crucial in transient protections such as traveling wave protection.Traditional recognition methods which adopt feature extraction and classification models rely heavily on the performance of signal processing and practical operation experiences.Misjudgments occur due to the poor generalization performance of recognition models.To improve the recognition rates and reliability of transient protection,this paper proposes a transient recognition method based on the deep belief network.The normalized line-mode components of transient currents on HVDC transmission lines are analyzed by a deep belief network which is properly designed.The feature learning process of the deep belief network can discover the inherent characteristics and improve recognition accuracy.Simulations are carried out to verify the effectiveness of the proposed method.Results demonstrate that the proposed method performs well in various scenarios and shows higher potential in practical applications than traditional machine learning based ones. 展开更多
关键词 Deep belief network transient recognition machine learning voltage source converter based high-voltage direct current(VSC-HVDC)
原文传递
Commutation Failure Mitigation Method Based on Imaginary Commutation Process 被引量:3
18
作者 Renlong Zhu Xiaoping Zhou +4 位作者 Haitao Xia Lerong Hong Hanhang Yin Lingfeng Deng Yifeng Liu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1413-1422,共10页
The commutation failure(CF) mitigation effectiveness is normally restricted by the delay of extinction angle(EA)measurement or the errors of existing prediction methods for EA or firing angle(FA). For this purpose, th... The commutation failure(CF) mitigation effectiveness is normally restricted by the delay of extinction angle(EA)measurement or the errors of existing prediction methods for EA or firing angle(FA). For this purpose, this paper proposes a CF mitigation method based on the imaginary commutation process. For each sample point, an imaginary commutation process is constructed to simulate the actual commutation process.Then, the imaginary EA is calculated by comparing the imaginary supply voltage-time area and the imaginary demand voltage-time area, which can update the imaginary EA earlier than the measured EA. In addition, the proposed method considers the impacts of commutation voltage variation, DC current variation, and phase angle shift of commutation voltage on the commutation process, which can ensure a more accurate EA calculation. Moreover, the DC current prediction is proposed to improve the CF mitigation performance under the single-phase AC faults. Finally, the simulation results based on CIGRE model prove that the proposed method has a good performance in CF mitigation. 展开更多
关键词 Commutation failure(CF) commutation failure mitigation extinction angle line commutated converter based high-voltage direct current(LCC-HVDC)
原文传递
A Commutation Failure Prediction and Mitigation Method 被引量:2
19
作者 Renlong Zhu Xiaoping Zhou +2 位作者 Haitao Xia Lerong Hong Hanhang Yin 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第3期779-787,共9页
The mitigation of commutation failure(CF)depends on the accuracy of CF prediction.In terms of the large error of the existing extinction angle(EA)calculation during the fault transient period,a method for CF predictio... The mitigation of commutation failure(CF)depends on the accuracy of CF prediction.In terms of the large error of the existing extinction angle(EA)calculation during the fault transient period,a method for CF prediction and mitigation is proposed.Variations in both DC current and overlap angle(OA)are considered in the proposed method to predict the EA rapidly.In addition,variations in critical EA and the effect of firing angle(FA)on both DC current and OA are considered in the proposed method to obtain the accurate FA order for the control system.The proposed method can achieve good performance in terms of CF mitigation and reduce reactive consumption at the inverter side when a fault occurs.Simulation results based on the PSCAD/EMTDC show that the proposed method predicts CF rapidly and exhibits good performance in terms of CF mitigation. 展开更多
关键词 Commutation failure prediction commutation failure mitigation line commutated converter based high-voltage direct current(LCC-HVDC) extinction angle(EA) overlap angle(OA) firing angle(FA)
原文传递
Integrated Optimal Siting and Sizing for VSCHVDC-link-based Offshore Wind Farms and Shunt Capacitors 被引量:4
20
作者 Yong Li Xuebo Qiao +5 位作者 Chun Chen Yi Tan Wenchao Tian Qiuping Xia Yijia Cao Kwang Y.Lee 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第2期274-284,共11页
It is economic and secure to determine the optimal siting and sizing of the offshore wind farms(OWFs)integrated into the AC system through voltage-source converter high-voltage direct current(VSC-HVDC)links.In this pa... It is economic and secure to determine the optimal siting and sizing of the offshore wind farms(OWFs)integrated into the AC system through voltage-source converter high-voltage direct current(VSC-HVDC)links.In this paper,an integrated planning model for the VSC-HVDC-link-based OWFs and the capacitors is proposed,where a decomposition technique is presented to solve the proposed mixed-integer nonlinear programming(MINLP)problem and obtain the optimal solution.This model can optimize the siting and sizing of the OWFs to improve the voltage profile and reduce the adverse influence of the reactive power of the OWFs.With the proposed planning model,the total investment costs,operation costs and maintenance costs of the OWFs,VSC-HVDC links,and the capacitors can be minimized.Simulations on the modified IEEE 118-bus system show that the proposed integrated planning model can provide more economic scheme than the independent planning scheme,in which the capacitors are planned after the OWFs.Besides,a series of sensitivity analysis on certain equipment costs are studied to obtain the regular pattern for sizing VSC stations. 展开更多
关键词 CAPACITOR installed capacity point of common coupling(PCC) offshore wind farm(OWF) voltage-source converter high-voltage direct current(VSC-HVDC)link
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部