Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine gro...Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine groundwater discharge.Here we developed a new approach to measure^(222)Rn in discrete water samples with a wide range of^(222)Rn concentrations using a Pulsed Ionization Chamber(PIC)Radon Detector.The sensitivity of the new PIC system is evaluated at 6.06 counts per minute for 1 Bq/L when a 500 mL water sample volume is used.A robust logarithmic correlation between sample volumes,ranging from 250 mL to 5000 mL,and system sensitivity obtained in this study strongly suggests that this approach is suitable for measuring radon concentration levels in various natural waters.Compared to the currently available methods for measuring radon in grab samples,the PIC system is cheaper,easier to operate and does not require extra accessories(e.g.,drying tubes etc.)to maintain stable measurements throughout the counting procedure.展开更多
The issues of how to quickly collect seawater samples and of how to make sure that those samples truly reflect the in-situ information on gas composition and concentration have therefore become a hot but difficult top...The issues of how to quickly collect seawater samples and of how to make sure that those samples truly reflect the in-situ information on gas composition and concentration have therefore become a hot but difficult topic in the field of ocean technology.Most conventional seawater samplers only focus on collecting seawater itself,but take little consideration on gas preservation.A set of new oceanographic tools are presented for ocean resource exploration such as hydrothermal sulfide and gas hydrate,and for investigations on the processes and mechanisms of marine physical,chemical and biological evolutions.A gas-tight deep-sea water sampling system(GTWSS) is designed for the collection of deep-sea geochemical samples.This set of tools mainly consists of a conductivity temperature depth profiler(CTD),release devices and gas-tight deep-sea water samplers(GTWS).The GTWS is able to hold the gases in deep-sea water samples tightly,providing in-situ information on gas contents in the seawater samples and can be deployed on a routine wire-deployed CTD sampler for multi-layer discrete sampling of gas-tight seawater.Sea trials are performed successfully in 2008 and 2009,on a research vessel named HaiYang Si Hao in South China Sea,with the deepest trial depth 3 930 m.GTWSS is capable of quickly sampling 12 discrete gas-tight seawater samples(8.3 L per sample) during its single deployment.The head space method is employed to separate the gases from the seawater samples immediately after recovery of the seawater samples on the vessel.Field geochemical analysis is carried out by gaseous hydrocarbon sensors and an infrared gas analyzer.Results show that the concentrations of CH4 and CO2 in the seawater sampled by GTWSS are higher than those sampled by general non-gas-tight water samplers,thus confirming the gas tightness of GTWSS.Seawater samples can be collected quickly by using GTWSS,and GTWSS can keep the samples' integrity quite well.展开更多
In this paper, the evaluation of discretely sampled Asian options was considered by numerically solving the associated partial differential equations with the Legendre spectral method. Double average options were disc...In this paper, the evaluation of discretely sampled Asian options was considered by numerically solving the associated partial differential equations with the Legendre spectral method. Double average options were discussed as examples. The problem is a parabolic one on a finite domain whose equation degenerates into ordinary differential equations on the boundaries. A fully discrete scheme was established by using the Legendre spectral method in space and the Crank-Nicolson finite difference scheme in time. The stability and convergence of the scheme were analyzed. Numerical results show that the method can keep the spectral accuracy in space for such degenerate problems.展开更多
This paper shows that for DEM simulations of triaxial tests using samples with a grading that is repre- sentative of a real soil, the sample size significantly influences the observed material response. Four DEM sampl...This paper shows that for DEM simulations of triaxial tests using samples with a grading that is repre- sentative of a real soil, the sample size significantly influences the observed material response. Four DEM samples with identical initial states were produced: three cylindrical samples bounded by rigid wails and one bounded by a cubical periodic cell, When subjected to triaxial loading, the samples with rigid boundaries were more dilative, stiffer and reached a higher peak stress ratio than the sample enclosed by periodic boundaries. For the rigid-wall samples, dilatancy increased and stiffness decreased with increasing sample size, The periodic sample was effectively homogeneous, The void ratio increased and the contact density decreased close to the rigid walls, This heterogeneity reduced with increasing sample size. The positions of the critical state lines (CSLs) of the overall response in e-log p' space were sensitive to the sample size, although no difference was observed between their slopes. The critical states of the interior regions of the rigid-wall-bounded samples approached that of the homogeneous periodic sample with increasing sample size. The ultimate strength of the material at the critical state is independent of sample size.展开更多
The representative elementary volume (REV) for three-dimensional polydisperse granular packings was determined using discrete element method simulations. Granular mixtures of various sizes and particle size distribu...The representative elementary volume (REV) for three-dimensional polydisperse granular packings was determined using discrete element method simulations. Granular mixtures of various sizes and particle size distributions were poured into a cuboid chamber and subjected to uniaxial compression, Findings showed that the minimum REV for porosity was larger compared with the REV for parameters such as coordination number, effective elastic modulus, and pressure ratio. The minimum REV for porosity and other parameters was found to equal 15,10, and 5 times the average grain diameter, respectively. A study of the influence of sample size on energy dissipation in random packing of spheres has also confirmed that the REV size is about 15 times the average grain diameter. The heterogeneity of systems was found to have no effect on the REV for the parameters of interest for the narrow range of coefficient of uniformity analyzed in this paper. As the REV approach is commonly applied in both experimental and numerical studies, determining minimum REV size for polydisperse granular packings remains a crucial issue.展开更多
基金The National Natural Science Foundation of China under contract Nos 42130410,41876075 and U1906210the Fundamental Research Funds for the Central Universities under contract No.201962003.
文摘Radon(Rn)is a naturally occurring radioactive inert gas in nature,and^(222)Rn has been routinely used as a powerful tracer in various aquatic environmental research on timescales of hours to days,such as submarine groundwater discharge.Here we developed a new approach to measure^(222)Rn in discrete water samples with a wide range of^(222)Rn concentrations using a Pulsed Ionization Chamber(PIC)Radon Detector.The sensitivity of the new PIC system is evaluated at 6.06 counts per minute for 1 Bq/L when a 500 mL water sample volume is used.A robust logarithmic correlation between sample volumes,ranging from 250 mL to 5000 mL,and system sensitivity obtained in this study strongly suggests that this approach is suitable for measuring radon concentration levels in various natural waters.Compared to the currently available methods for measuring radon in grab samples,the PIC system is cheaper,easier to operate and does not require extra accessories(e.g.,drying tubes etc.)to maintain stable measurements throughout the counting procedure.
基金supported by National Hi-tech Research and Development Program of China(863 Program,Grant Nos. 2006AA09A204-1,2006AA09Z222-1,2009AA09A20401-1)
文摘The issues of how to quickly collect seawater samples and of how to make sure that those samples truly reflect the in-situ information on gas composition and concentration have therefore become a hot but difficult topic in the field of ocean technology.Most conventional seawater samplers only focus on collecting seawater itself,but take little consideration on gas preservation.A set of new oceanographic tools are presented for ocean resource exploration such as hydrothermal sulfide and gas hydrate,and for investigations on the processes and mechanisms of marine physical,chemical and biological evolutions.A gas-tight deep-sea water sampling system(GTWSS) is designed for the collection of deep-sea geochemical samples.This set of tools mainly consists of a conductivity temperature depth profiler(CTD),release devices and gas-tight deep-sea water samplers(GTWS).The GTWS is able to hold the gases in deep-sea water samples tightly,providing in-situ information on gas contents in the seawater samples and can be deployed on a routine wire-deployed CTD sampler for multi-layer discrete sampling of gas-tight seawater.Sea trials are performed successfully in 2008 and 2009,on a research vessel named HaiYang Si Hao in South China Sea,with the deepest trial depth 3 930 m.GTWSS is capable of quickly sampling 12 discrete gas-tight seawater samples(8.3 L per sample) during its single deployment.The head space method is employed to separate the gases from the seawater samples immediately after recovery of the seawater samples on the vessel.Field geochemical analysis is carried out by gaseous hydrocarbon sensors and an infrared gas analyzer.Results show that the concentrations of CH4 and CO2 in the seawater sampled by GTWSS are higher than those sampled by general non-gas-tight water samplers,thus confirming the gas tightness of GTWSS.Seawater samples can be collected quickly by using GTWSS,and GTWSS can keep the samples' integrity quite well.
文摘In this paper, the evaluation of discretely sampled Asian options was considered by numerically solving the associated partial differential equations with the Legendre spectral method. Double average options were discussed as examples. The problem is a parabolic one on a finite domain whose equation degenerates into ordinary differential equations on the boundaries. A fully discrete scheme was established by using the Legendre spectral method in space and the Crank-Nicolson finite difference scheme in time. The stability and convergence of the scheme were analyzed. Numerical results show that the method can keep the spectral accuracy in space for such degenerate problems.
基金funding from the Royal Commission for the Exhibition of 1851provided as part of grant EP/1006761/1 from the Engineering and Physical Sciences Research Council
文摘This paper shows that for DEM simulations of triaxial tests using samples with a grading that is repre- sentative of a real soil, the sample size significantly influences the observed material response. Four DEM samples with identical initial states were produced: three cylindrical samples bounded by rigid wails and one bounded by a cubical periodic cell, When subjected to triaxial loading, the samples with rigid boundaries were more dilative, stiffer and reached a higher peak stress ratio than the sample enclosed by periodic boundaries. For the rigid-wall samples, dilatancy increased and stiffness decreased with increasing sample size, The periodic sample was effectively homogeneous, The void ratio increased and the contact density decreased close to the rigid walls, This heterogeneity reduced with increasing sample size. The positions of the critical state lines (CSLs) of the overall response in e-log p' space were sensitive to the sample size, although no difference was observed between their slopes. The critical states of the interior regions of the rigid-wall-bounded samples approached that of the homogeneous periodic sample with increasing sample size. The ultimate strength of the material at the critical state is independent of sample size.
文摘The representative elementary volume (REV) for three-dimensional polydisperse granular packings was determined using discrete element method simulations. Granular mixtures of various sizes and particle size distributions were poured into a cuboid chamber and subjected to uniaxial compression, Findings showed that the minimum REV for porosity was larger compared with the REV for parameters such as coordination number, effective elastic modulus, and pressure ratio. The minimum REV for porosity and other parameters was found to equal 15,10, and 5 times the average grain diameter, respectively. A study of the influence of sample size on energy dissipation in random packing of spheres has also confirmed that the REV size is about 15 times the average grain diameter. The heterogeneity of systems was found to have no effect on the REV for the parameters of interest for the narrow range of coefficient of uniformity analyzed in this paper. As the REV approach is commonly applied in both experimental and numerical studies, determining minimum REV size for polydisperse granular packings remains a crucial issue.