BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with lon...BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with long-term follow-up is required to validate these initial findings.AIM To review the literature on the outcomes of distal radius hemiarthroplasty with available implants to assess its viability as a treatment option.METHODS A comprehensive review of the literature was conducted using electronic databases,including PubMed,Medline,and Scopus.The search terms employed were"distal radius fracture","hemiarthroplasty","wrist arthroplasty",and related terminology.The search was restricted to articles published in English from 1980 until June 2023.Inclusion criteria encompassed cases or case series of DRF treated with hemiarthroplasty,providing clinical or radiographic outcomes,and published in peer-reviewed journals.RESULTS A total of 2508 articles from PubMed and 883 from Scopus were identified initially.Following screening and removal of duplicates,13 articles met the inclusion criteria.These articles,predominantly clinical retrospective studies,provided insights into hemiarthroplasty outcomes,including functional improvements and complications.Hemiarthroplasty was a treatment option for complex DRF,particularly those cases with severe comminution,intraarticular involvement,or severe osteoporosis.Functional outcomes demonstrated improvements in pain relief,wrist mobility,and grip strength,with variability across studies.Complications included implant loosening,infection,nerve injury,and stiffness,with varying incidence rates influenced by surgical techniques and implant choice.Long-term outcomes were inadequately documented,warranting further research.CONCLUSION Hemiarthroplasty is a promising treatment for irreparable DRF in the elderly.Long-term outcomes and complications require further study.展开更多
BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal...BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal clavicle fractures treated utilizing an anterior inferior plate with a single screw placed in the distal,in anticipation of providing a better surgical approach to distal clavicle fracture treatment.Two patients were admitted to the hospital after trauma with a diagnosis of distal clavicle fracture,and were admitted to the hospital for internal fixation of clavicle fracture by incision and reduction,with good postoperative functional recovery.CONCLUSION With solid postoperative fixation and satisfactory prognostic functional recovery,this technique has been shown to be simple,easy to perform and effective.展开更多
BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixati...BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixation is the treatment of choice among orthopaedics.Conventional plates allow stability of the fracture if bone quality is present.Locking plates might offer an advantage for the treatment of lateral malleolar fracture in patients with comminution,severe instability,distal fractures,or osteoporotic bone.Our hospital introduced a new locking plate for fracture of the distal fibula.AIM To evaluate locking plates in terms of outcomes and complications in young and elderly patients.METHODS We retrospectively reviewed a total of 67 patients treated for displaced distal fibula fractures.Demographic data,number of comorbidities,use of inter fragmentary screw,complication,time of fracture healing,partial or full weight bearing,and reoperation were recorded for all patients.Clinical outcome was assessed by the American Orthopedic Foot and Ankle Society clinical scoring system.Radiographs were obtained at 4,8,12,16,20,and 24 wk until radiographic union was obtained.RESULTS All patients displayed complete bony union on radiographic assessment,and no patients developed any serious complications.We observed two superficial infections,one delayed wound healing,and two plate intolerances.Significant differences were observed between the two age groups in terms of radiographic healing(11.9 wk in younger patients vs 13.7 wk in older patients;P=0.011)and in the American Orthopedic Foot and Ankle Society score at 6 mo after surgery(88.2 in younger patients vs 86.0 in older patients;P=0.001)and at 12 mo after surgery(92.6 in younger patients vs 90.0 in older patients;P=0.000).CONCLUSION Locking plates provide a stable and rigid fixation in multifragmentary and comminuted fractures or in the presence of poor bone quality.展开更多
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ...Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.展开更多
Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element ana...Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.展开更多
Objective:To investigate the effect of manual reduction with traditional small splints fixation for distal radius fractures in older patients in the emergency department.Methods:Older patients(aged at least 60 years)w...Objective:To investigate the effect of manual reduction with traditional small splints fixation for distal radius fractures in older patients in the emergency department.Methods:Older patients(aged at least 60 years)with distal radius fractures were enrolled in this study.The patients were randomly divided into the treatment group and the control group.The treatment group was treated with manual reduction and small splints fixation.The control group was treated with manual reduction and resin plaster fixation.Before treatment,after reduction,and 3 months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length were recorded.Before treatment and 3 months after treatment,the Cooney wrist joint scores were recorded.The time of fracture healing and related adverse events during the treatment were recorded.Results:Before treatment and after reduction,there were no statistically significant differences between the two groups in palmar tilt angle,ulnar deviation angle,or radial length(P>0.05).Three months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length of the treatment group were better than those of the control group(P<0.05).The Cooney wrist scores of the treatment group was significantly higher than that of the control group three months after the treatment(P<0.05).The time of fracture healing of the treatment group was shorter than that of the control group,but the difference was no statistically significant(P>0.05).Conclusions:Compared with resin plaster fixation,traditional small splints fixation for distal radius fractures in older patients have the advantages of less loss of fracture reduction and faster functional recovery.Besides,the method is simple and low cost thus,it needs to be promoted.展开更多
AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ...AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ± 18 years) who had X-ray(CR) and computed tomography(CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex(PQC) was measured using lateral views(CR) and sagittal reconstructions(CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign(PQS) was defined as a PQC > 8.0 mm(female) or > 9.0 mm(male). Frykman classification was utilized to assess the severity of fractures.RESULTS Forty-four/89 patients(49%) had a distal radius fracture(Frykman Ⅰ n = 3, Ⅱ n = 0, Ⅲ n = 10, Ⅳ n = 5, Ⅴ n = 2, Ⅵ n = 2, Ⅶ n = 9, Ⅷ n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views(CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions(CT), resulting in a significant correlation coefficientof 0.795. A positive PQS at CR was present in 21/44 patients(48%) with distal radius fracture and in 2/45 patients(4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures.CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.展开更多
The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters fol...The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after I week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P = 0.001), supination, (P = 0.047) and extension (P = 0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at I year. The plating group had a greater occurrence of wound infection (P = 0.043), tendonitis, (P = 0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the "gross motor" category (walking upstairs, bending over, walking 500 yards; P = 0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after I year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries.展开更多
BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower lim...BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower limb fracture surgery.LEDVT and PTE after upper extremity fracture surgery are very rare.PTE is one of the most common clinical causes of sudden death.Venous thromboembolism includes PTE and DVT.We experienced one case of LEDVT and PTE after distal ulna and radius fracture surgery.The purpose of our report is to raise awareness for orthopedic surgeons that PTE can occur after distal ulna and radius fracture surgery,and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.CASE SUMMARY We report a 51-year-old Chinese male who had severe fractures of the left distal ulna,radius and little finger after a motorcycle accident.The patient underwent external fixation,open reduction and internal fixation.On the third post-operative day,computed tomographic pulmonary angiography showed PTE.Doppler ultrasonography showed thrombus formation in the bilateral posterior tibial veins.After a period of anticoagulation therapy,on the 25th d after the PTE,computed tomographic pulmonary angiography showed that thrombus in both sides of the pulmonary artery disappeared.Furthermore,about 4 mo after the PTE,thrombosis in the deep veins of the lower limbs disappeared.About 1 year after the surgery,X-rays showed good fracture healing,and the function of the wrist joint recovered well.CONCLUSION Though rare,PTE can occur after distal ulna and radius fracture surgery and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.展开更多
<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Wheth...<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Whether anesthesia type affects patient outcomes is unclear. </span><span>This study retrospectively compared patient satisfaction between GA and NB after surgery. </span><b><span>Methods: </span></b><span>This was a historical cohort study of 80 (34 GA and 46 NB) patients who underwent volar plate fixation of distal radius fractures. Propensity score analysis was used to generate a set of matched cases (NB) and controls (GA), yielding 14 matched patient-pairs. The simplified patient satisfaction scale was compared for primary outcomes. Secondary outcomes were anesthesia and surgery duration, hospital stay length, adverse events, postoperative analgesic requirement, and wrist range of motion (ROM) 2 weeks and 3 months postoperatively.</span><span> </span><b><span>Results:</span></b><span> After propensity score matching, patients in almost all cases in both groups were “Satisfied” (effect size: 0.1, p</span><span> </span><span>=</span><span> </span><span>0.572), indicating little significant difference. Significant differences in adverse events and postoperative analgesic use observed before matching disappeared after matching. Anesthesia duration and hospital stay length were significantly shorter in the NB group (effect size: </span><span>-</span><span>1.27 and </span><span>-</span><span>0.77, p</span><span> </span><span>=</span><span> </span><span>0.00074 and p</span><span> </span><span>=</span><span> </span><span>0.0388, respectively), as was surgery duration (effect size: </span><span>-</span><span>0.84, p</span><span> </span><span>=</span><span> </span><span>0.0122) after matching. Similar to before matching, wrist ROM significantly improved in the NB group (effect size: 1.11, p</span><span> </span><span>=</span><span> </span><span>0.0279) in the early postoperative period, but the difference disappeared at 3 months postoperatively.</span><span> </span><b><span>Conclusions:</span></b><span> Patient satisfaction between distal radius fracture surgery under GA and NB was similar. Nerve block could help shorten hospital stay length and surgery duration and improve postoperative functional recovery.</span>展开更多
BACKGROUND Coronal shear fractures of the distal humerus are rare injuries and are technically challenging to manage.Open reduction and internal fixation(ORIF)has become the preferred treatment because it provides ana...BACKGROUND Coronal shear fractures of the distal humerus are rare injuries and are technically challenging to manage.Open reduction and internal fixation(ORIF)has become the preferred treatment because it provides anatomical reduction,stable internal fixation,and early motion,but the optimal surgical approach remains controversial.CASE SUMMARY We report three cases of coronal shear fractures of the distal humerus treated successfully by ORIF via a novel surgical approach,in which lateral epicondyle osteotomy was performed based on the extended lateral approach.We named the novel surgical approach the lateral epicondyle osteotomy approach.All patients underwent surgical treatment and were discharged successfully.All patients had excellent functional results according to the Mayo elbow performance score.The average range of motion was 118°in flexion/extension and 172°in pronation/supination.Only case 2 had a complication,which was implant prolapse.CONCLUSION We demonstrated that the lateral epicondyle osteotomy approach in ORIF is effective and safe for coronal shear fractures of the distal humerus.展开更多
BACKGROUND Ulnar nerve injury subsequent to a fracture of the distal radius is extremely rare compared to median nerve injury.Treatment of ulnar nerve injury after closed distal radial fracture is controversial.Reason...BACKGROUND Ulnar nerve injury subsequent to a fracture of the distal radius is extremely rare compared to median nerve injury.Treatment of ulnar nerve injury after closed distal radial fracture is controversial.Reasonable surgical planning and careful postoperative management can improve the prognosis of patients.CASE SUMMARY We report two cases of ulnar nerve injury subsequent to fracture of the distal radius.Both patients were admitted to hospital.Both patients had persistent ulnar nerve compression syndromes.The first patient achieved rapid recovery by early nerve decompression surgery,while the second patient had no recovery at 2-3 mo after injury and had more severe symptoms.At 10 wk after injury,the second patient agreed to nerve decompression surgery.The second patient finally achieved a successful outcome after nerve decompression and neurolysis,although she still has residual symptoms.CONCLUSION For patients with ulnar nerve compression syndrome related to acute wrist fracture,if symptoms persist and signs of recovery are not observed,early release is necessary to prevent permanent neurological damage.展开更多
BACKGROUND Surgical treatment of complex fractures of the distal femur in the elderly is controversial.Osteoporosis and pre-existent osteoarthritis are common comorbidities in the elderly which add to the need for ear...BACKGROUND Surgical treatment of complex fractures of the distal femur in the elderly is controversial.Osteoporosis and pre-existent osteoarthritis are common comorbidities in the elderly which add to the need for early walking and rapid restoration of function and also pose significant obstacles to achievement of satisfactory results with standard fixation techniques.Recently,several authors have suggested that primary arthroplasty could be a viable alternative option to standard fixation techniques in selected patients with complex distal femur fractures.AIM To present our experience with 11 cases of distal femur fractures treated with knee arthroplasty and large femoral resection in a population of patients over the age of 85.METHODS Data from 11 consecutive patients(10 females,1 male)presenting with acute intra-articular supracondylar or intercondylar distal femur fractures and with pre-existent primary osteoarthritis who were treated with primary knee arthroplasty were recorded.We collected standard demographic data,comorbidities and patient reported outcomes including Visual Analogical Scale(VAS),Oxford Knee Score(OKS)and Barthel’s Index.Post-operative joint range of motion(ROM)and standard radiographic data were also collected.RESULTS At a mean follow-up of 23.2 mo,all of the implants were well-positioned and osteointegrated.Furthermore,all the patients were alive and walking either independently or with walking aids.There was a marked improvement in pain(VAS 4.5 postop vs 1.9 at the last follow-up),OKS score(29.5 postop vs 36.81 at the last follow-up),ROM(96.2°postop vs 102°at the last follow-up)and restoration of pre-injury ambulatory status(average Barthel Index 77.3).The radiographic evaluations showed good restoration of the articular geometry.No deaths and no complications were recorded.CONCLUSION In conclusion,we believe that knee megaprosthesis in the case of complex fractures of the distal femur is a valid surgical choice.This is particularly true in elderly patients with severe osteoporosis and pre-existing osteoarthritis.It is important to note that this surgery should be performed by surgeons with proven experience in prosthetic hip and knee surgery and that a scrupulous selection of the cases is completed.展开更多
Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,...Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,VIP and Wanfang,were searched for the original study.Literature was screened according to the inclusion and exclusion criteria,and the methodological quality of the included studies was evaluated by Cochrane risk bias assessment tool.The software Revman 5.4 was used for data analysis.Results:A total of 19 studies were included in the study.The clinical effective rate of the plate group[RR=0.96,95%CI(0.93,0.99),P=0.007],Radial inclination[MD=-1.85,95%CI(-2.93,-0.77),P=0.0008],Ulnar inclination[MD=-2.49,95%CI(-3.95,-1.04),P=0.0007],relative height of radius[MD=-1.63,95%CI(-2.40,-0.86),P<0.0001]were better than those in small splints group.There was no significant difference in fracture healing time[MD=-4.39,95%CI(-9.07,0.28),P=0.07]and complications[RR=1.57,95%CI(0.98,2.52),P=0.06]between the two groups.In terms of treatment cost[MD=-2.83,95%CI(-3.37,-2.30),P<0.00001],the small splint group was better than the plate treatment group.Conclusion:Compared with small splints therapy,plate internal fixation has advantages in clinical effective rate and imaging scores.There is no significant difference in fracture healing time and complications between the two groups.In terms of treatment cost,small splint therapy is better than plate therapy.Clinical treatment should be selected and formulated according to the individual situation,demands and clinical practice of patients.展开更多
BACKGROUND Distal radius fractures(DRFs)are a common challenge in orthopaedic trauma care,yet for those fractures that are treated nonoperatively,strong evidence to guide cast treatment is still lacking.AIM To compare...BACKGROUND Distal radius fractures(DRFs)are a common challenge in orthopaedic trauma care,yet for those fractures that are treated nonoperatively,strong evidence to guide cast treatment is still lacking.AIM To compare the efficacy of below elbow cast(BEC)and above elbow cast(AEC)in maintaining reduction of manipulated DRFs.METHODS We conducted a prospective,monocentric,randomized,parallel-group,open label,blinded,noninferiority trial comparing the efficacy of BEC and AEC in the nonoperative treatment of DRFs.Two hundred and eighty patients>18 years of age diagnosed with DRFs were successfully randomized and included for analysis over a 3-year period.Noninferiority thresholds were defined as a 2 mm difference for radial length(RL),a 3°difference for radial inclination(RI),and volar tilt(VT).The trial is registered at Clinicaltrials.gov(NCT03468023).RESULTS One hundred and forty-three patients were treated with BEC,and 137 were treated with AEC.The mean time of immobilization was 33 d.The mean loss of RL,RI,and VT was 1.59 mm,2.83°,and 4.11°for BEC and 1.63 mm,2.54°,and VT loss were respectively 0.04 mm(95%CI:-0.36-0.44),-0.29°(95%CI:-1.03-0.45),and 0.59°(95%CI:-1.39-2.57),and they were all below the prefixed noninferiority thresholds.The rate of loss of reduction was similar.CONCLUSION BEC performs as well as AEC in maintaining the reduction of a manipulated DRF.Being more comfortable to patients,BEC may be preferable for nonoperative treatment of DRFs.展开更多
Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic...Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.展开更多
Distal radius fractures are common and while historically most have been treated nonoperatively the frequency with which distal radius fractures are treated surgically is increasing. Criteria for considering surgical ...Distal radius fractures are common and while historically most have been treated nonoperatively the frequency with which distal radius fractures are treated surgically is increasing. Criteria for considering surgical treatment are often based on radiographic appearance of the fracture. Less often discussed is patient preference: what do patients want. We investigated responses of a general population when presented with various treatment options following a hypothetical distal radius fracture. Many respondents chose nonoperative treatment even when told that surgery might result in a better outcome. This information can help during the shared decision-making process when discussing treatment options with a patient who presents with a distal radius fracture.展开更多
To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture usin...To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab.展开更多
BACKGROUND Neonatal distal humeral physeal fractures are rare and difficult to diagnose.Thus,missed diagnoses and delayed healing are possible.Few studies have reported surgical treatment,because a callus may develop ...BACKGROUND Neonatal distal humeral physeal fractures are rare and difficult to diagnose.Thus,missed diagnoses and delayed healing are possible.Few studies have reported surgical treatment,because a callus may develop at the fracture site 5 d after the fracture,resulting in difficult reduction,and reduction of the limb may cause further physeal injury.Other surgical challenges include the provision of adequate anesthesia and complexity of the operation.However,without appropriate reduction and fixation,a varus elbow deformity may develop.Manual reduction and percutaneous pin fixation are ideal treatment options.CASE SUMMARY A 4-day-old neonate with left elbow pain accompanied by limited movement for 4 d was admitted,and diagnosed with delayed physeal fracture of the distal humerus based on physical examination,ultrasonography,and magnetic resonance imaging.The patient was treated by manual reduction combined with percutaneous pin fixation under arthrography.Postoperatively,the reduction was successful.The upper limbs could have been lifted and the fingers could have been moved freely on the second day after the operation.CONCLUSION The techniques of manual reduction and percutaneous pin fixation,to treat neonatal distal humeral physeal fractures,are safe and reliable.展开更多
Background L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation.Repair of the PQ muscle was always reco...Background L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation.Repair of the PQ muscle was always recommended at the end of operation for some instructive reasons.But repair of PQ is not satisfied because of poor quality of muscle and fascial tissues which may cause pain or impede forearm pronation and supination for post-operative scarring around PQ.Inserting the locking palmar plate to pass under the pronator quadratus muscle and the locking screws are inserted through miniincisions in pronator quadratus in some patients with distal radius fractures is a reasonable technique which can preserve the pronator quadratus.The purpose of this study was to evaluate and compare the clinical effects after volar plating of the distal radius fractures while preserving the pronator quadratus and pronator quadratus repair.Methods Between September 2010 and April 2012,65 patients (42 males and 23 females; aged 20-68 years and a mean age of 42.5 years) with distal radius fracture underwent open reduction and internal fixation using the volar locking palmar plates (Depuy or Smith companies).The patients were classified as 23A-2 through 23C-3 according to the Orthopaedic Trauma Association (OTA) classifications.All surgeries were completed by the same trained team.The volar locking palmar plates of distal radius performed with preserving pronator quadratus group involved 30 patients including 19 males and 11 females and performed with pronator quadratus repair group involved 35 patients including 23 males and 12 females.We compared the two groups for wrist pain,forearm range of motion,grip strength,pedoperative complications and wrist functional recovery score.Results The minimum follow-up for the whole cohort was one year.The differences between the two groups were significant with regard to wrist pain,forearm range of motion,grip strength and wrist function at 1,2,and 6 weeks postoperatively,but insignificant at 6 and 12 months postoperatively.No significant differences were found in the pedoperative complications and radiographs postoperatively.Conclusions Preservation of the pronator quadratus muscle is a satisfactory method for the treatment of majority of the fractures of the distal radius with volar locking palmar plates,as this technique can yield better early wrist function and shorten the rehabilitation.展开更多
文摘BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with long-term follow-up is required to validate these initial findings.AIM To review the literature on the outcomes of distal radius hemiarthroplasty with available implants to assess its viability as a treatment option.METHODS A comprehensive review of the literature was conducted using electronic databases,including PubMed,Medline,and Scopus.The search terms employed were"distal radius fracture","hemiarthroplasty","wrist arthroplasty",and related terminology.The search was restricted to articles published in English from 1980 until June 2023.Inclusion criteria encompassed cases or case series of DRF treated with hemiarthroplasty,providing clinical or radiographic outcomes,and published in peer-reviewed journals.RESULTS A total of 2508 articles from PubMed and 883 from Scopus were identified initially.Following screening and removal of duplicates,13 articles met the inclusion criteria.These articles,predominantly clinical retrospective studies,provided insights into hemiarthroplasty outcomes,including functional improvements and complications.Hemiarthroplasty was a treatment option for complex DRF,particularly those cases with severe comminution,intraarticular involvement,or severe osteoporosis.Functional outcomes demonstrated improvements in pain relief,wrist mobility,and grip strength,with variability across studies.Complications included implant loosening,infection,nerve injury,and stiffness,with varying incidence rates influenced by surgical techniques and implant choice.Long-term outcomes were inadequately documented,warranting further research.CONCLUSION Hemiarthroplasty is a promising treatment for irreparable DRF in the elderly.Long-term outcomes and complications require further study.
基金Supported by Science Foundation Project of Baotou Medical College,No.BYJJ-YF-2018006.
文摘BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal clavicle fractures treated utilizing an anterior inferior plate with a single screw placed in the distal,in anticipation of providing a better surgical approach to distal clavicle fracture treatment.Two patients were admitted to the hospital after trauma with a diagnosis of distal clavicle fracture,and were admitted to the hospital for internal fixation of clavicle fracture by incision and reduction,with good postoperative functional recovery.CONCLUSION With solid postoperative fixation and satisfactory prognostic functional recovery,this technique has been shown to be simple,easy to perform and effective.
文摘BACKGROUND Ankle fractures are common injuries in the young and elderly populations.To prevent post-traumatic arthritis,an anatomic reconstruction of the ankle structure is mandatory.Open reduction and internal fixation is the treatment of choice among orthopaedics.Conventional plates allow stability of the fracture if bone quality is present.Locking plates might offer an advantage for the treatment of lateral malleolar fracture in patients with comminution,severe instability,distal fractures,or osteoporotic bone.Our hospital introduced a new locking plate for fracture of the distal fibula.AIM To evaluate locking plates in terms of outcomes and complications in young and elderly patients.METHODS We retrospectively reviewed a total of 67 patients treated for displaced distal fibula fractures.Demographic data,number of comorbidities,use of inter fragmentary screw,complication,time of fracture healing,partial or full weight bearing,and reoperation were recorded for all patients.Clinical outcome was assessed by the American Orthopedic Foot and Ankle Society clinical scoring system.Radiographs were obtained at 4,8,12,16,20,and 24 wk until radiographic union was obtained.RESULTS All patients displayed complete bony union on radiographic assessment,and no patients developed any serious complications.We observed two superficial infections,one delayed wound healing,and two plate intolerances.Significant differences were observed between the two age groups in terms of radiographic healing(11.9 wk in younger patients vs 13.7 wk in older patients;P=0.011)and in the American Orthopedic Foot and Ankle Society score at 6 mo after surgery(88.2 in younger patients vs 86.0 in older patients;P=0.001)and at 12 mo after surgery(92.6 in younger patients vs 90.0 in older patients;P=0.000).CONCLUSION Locking plates provide a stable and rigid fixation in multifragmentary and comminuted fractures or in the presence of poor bone quality.
基金2022 Key Specialty Construction Project of Traditional Chinese Medicine:Traditional Chinese Orthopedics and Traumatology Department (No.962042)2020 Regional Traditional Chinese Medicine (Orthopedics and Traumatology)Diagnosis and Treatment Center (Jin Wei Zhong[2020]No.5)。
文摘Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.
文摘Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.
基金supported by scientific research project of China National Medicine Association(2019KYXM-Z199-35).
文摘Objective:To investigate the effect of manual reduction with traditional small splints fixation for distal radius fractures in older patients in the emergency department.Methods:Older patients(aged at least 60 years)with distal radius fractures were enrolled in this study.The patients were randomly divided into the treatment group and the control group.The treatment group was treated with manual reduction and small splints fixation.The control group was treated with manual reduction and resin plaster fixation.Before treatment,after reduction,and 3 months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length were recorded.Before treatment and 3 months after treatment,the Cooney wrist joint scores were recorded.The time of fracture healing and related adverse events during the treatment were recorded.Results:Before treatment and after reduction,there were no statistically significant differences between the two groups in palmar tilt angle,ulnar deviation angle,or radial length(P>0.05).Three months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length of the treatment group were better than those of the control group(P<0.05).The Cooney wrist scores of the treatment group was significantly higher than that of the control group three months after the treatment(P<0.05).The time of fracture healing of the treatment group was shorter than that of the control group,but the difference was no statistically significant(P>0.05).Conclusions:Compared with resin plaster fixation,traditional small splints fixation for distal radius fractures in older patients have the advantages of less loss of fracture reduction and faster functional recovery.Besides,the method is simple and low cost thus,it needs to be promoted.
文摘AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ± 18 years) who had X-ray(CR) and computed tomography(CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex(PQC) was measured using lateral views(CR) and sagittal reconstructions(CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign(PQS) was defined as a PQC > 8.0 mm(female) or > 9.0 mm(male). Frykman classification was utilized to assess the severity of fractures.RESULTS Forty-four/89 patients(49%) had a distal radius fracture(Frykman Ⅰ n = 3, Ⅱ n = 0, Ⅲ n = 10, Ⅳ n = 5, Ⅴ n = 2, Ⅵ n = 2, Ⅶ n = 9, Ⅷ n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views(CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions(CT), resulting in a significant correlation coefficientof 0.795. A positive PQS at CR was present in 21/44 patients(48%) with distal radius fracture and in 2/45 patients(4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures.CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.
基金supported by National Natural Science Foundation of China Grant 81560350
文摘The purpose of this study was to compare the functional outcomes, psychological impact, and complication rates associated with external fixation and volar or dorsal plating in relation to the functional parameters following treatment of intra-articular fractures of the distal radius (IFDR) in patients older than 65 years. We hypothesized that using volar or dorsal plating would improve functional outcomes, but that it would be associated with more complications and equivalent functional outcomes when compared with the external fixation group. A total of 123 consecutive patients suffering from IFDR were recruited into the study. The patients were measured for clinical, radiological, and psychosocial functioning outcomes and were followed up after I week and 3, 6 and 12 months. After 3 months, the plating group had better pronation (P = 0.001), supination, (P = 0.047) and extension (P = 0.043) scores. These differences were somewhat attenuated by 6 months and disappeared at I year. The plating group had a greater occurrence of wound infection (P = 0.043), tendonitis, (P = 0.024) and additional surgery compared with the external fixation group. The only TNO-AZL Adult Quality of Life scores in the plating group that were lower than those in the external fixation group were in the "gross motor" category (walking upstairs, bending over, walking 500 yards; P = 0.023). Internal fixation was more advantageous than external fixation in the early rehabilitation period; after I year the outcomes were similar. The plating group showed significantly higher levels of wound infection and tendonitis and had a greater need for additional surgeries.
基金Shanghai Fengxian District Osteoarthropathy Clinical Diagnosis and Treatment Center,China,No.fxlczlzx-a-201704.
文摘BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower limb fracture surgery.LEDVT and PTE after upper extremity fracture surgery are very rare.PTE is one of the most common clinical causes of sudden death.Venous thromboembolism includes PTE and DVT.We experienced one case of LEDVT and PTE after distal ulna and radius fracture surgery.The purpose of our report is to raise awareness for orthopedic surgeons that PTE can occur after distal ulna and radius fracture surgery,and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.CASE SUMMARY We report a 51-year-old Chinese male who had severe fractures of the left distal ulna,radius and little finger after a motorcycle accident.The patient underwent external fixation,open reduction and internal fixation.On the third post-operative day,computed tomographic pulmonary angiography showed PTE.Doppler ultrasonography showed thrombus formation in the bilateral posterior tibial veins.After a period of anticoagulation therapy,on the 25th d after the PTE,computed tomographic pulmonary angiography showed that thrombus in both sides of the pulmonary artery disappeared.Furthermore,about 4 mo after the PTE,thrombosis in the deep veins of the lower limbs disappeared.About 1 year after the surgery,X-rays showed good fracture healing,and the function of the wrist joint recovered well.CONCLUSION Though rare,PTE can occur after distal ulna and radius fracture surgery and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.
文摘<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Whether anesthesia type affects patient outcomes is unclear. </span><span>This study retrospectively compared patient satisfaction between GA and NB after surgery. </span><b><span>Methods: </span></b><span>This was a historical cohort study of 80 (34 GA and 46 NB) patients who underwent volar plate fixation of distal radius fractures. Propensity score analysis was used to generate a set of matched cases (NB) and controls (GA), yielding 14 matched patient-pairs. The simplified patient satisfaction scale was compared for primary outcomes. Secondary outcomes were anesthesia and surgery duration, hospital stay length, adverse events, postoperative analgesic requirement, and wrist range of motion (ROM) 2 weeks and 3 months postoperatively.</span><span> </span><b><span>Results:</span></b><span> After propensity score matching, patients in almost all cases in both groups were “Satisfied” (effect size: 0.1, p</span><span> </span><span>=</span><span> </span><span>0.572), indicating little significant difference. Significant differences in adverse events and postoperative analgesic use observed before matching disappeared after matching. Anesthesia duration and hospital stay length were significantly shorter in the NB group (effect size: </span><span>-</span><span>1.27 and </span><span>-</span><span>0.77, p</span><span> </span><span>=</span><span> </span><span>0.00074 and p</span><span> </span><span>=</span><span> </span><span>0.0388, respectively), as was surgery duration (effect size: </span><span>-</span><span>0.84, p</span><span> </span><span>=</span><span> </span><span>0.0122) after matching. Similar to before matching, wrist ROM significantly improved in the NB group (effect size: 1.11, p</span><span> </span><span>=</span><span> </span><span>0.0279) in the early postoperative period, but the difference disappeared at 3 months postoperatively.</span><span> </span><b><span>Conclusions:</span></b><span> Patient satisfaction between distal radius fracture surgery under GA and NB was similar. Nerve block could help shorten hospital stay length and surgery duration and improve postoperative functional recovery.</span>
文摘BACKGROUND Coronal shear fractures of the distal humerus are rare injuries and are technically challenging to manage.Open reduction and internal fixation(ORIF)has become the preferred treatment because it provides anatomical reduction,stable internal fixation,and early motion,but the optimal surgical approach remains controversial.CASE SUMMARY We report three cases of coronal shear fractures of the distal humerus treated successfully by ORIF via a novel surgical approach,in which lateral epicondyle osteotomy was performed based on the extended lateral approach.We named the novel surgical approach the lateral epicondyle osteotomy approach.All patients underwent surgical treatment and were discharged successfully.All patients had excellent functional results according to the Mayo elbow performance score.The average range of motion was 118°in flexion/extension and 172°in pronation/supination.Only case 2 had a complication,which was implant prolapse.CONCLUSION We demonstrated that the lateral epicondyle osteotomy approach in ORIF is effective and safe for coronal shear fractures of the distal humerus.
文摘BACKGROUND Ulnar nerve injury subsequent to a fracture of the distal radius is extremely rare compared to median nerve injury.Treatment of ulnar nerve injury after closed distal radial fracture is controversial.Reasonable surgical planning and careful postoperative management can improve the prognosis of patients.CASE SUMMARY We report two cases of ulnar nerve injury subsequent to fracture of the distal radius.Both patients were admitted to hospital.Both patients had persistent ulnar nerve compression syndromes.The first patient achieved rapid recovery by early nerve decompression surgery,while the second patient had no recovery at 2-3 mo after injury and had more severe symptoms.At 10 wk after injury,the second patient agreed to nerve decompression surgery.The second patient finally achieved a successful outcome after nerve decompression and neurolysis,although she still has residual symptoms.CONCLUSION For patients with ulnar nerve compression syndrome related to acute wrist fracture,if symptoms persist and signs of recovery are not observed,early release is necessary to prevent permanent neurological damage.
文摘BACKGROUND Surgical treatment of complex fractures of the distal femur in the elderly is controversial.Osteoporosis and pre-existent osteoarthritis are common comorbidities in the elderly which add to the need for early walking and rapid restoration of function and also pose significant obstacles to achievement of satisfactory results with standard fixation techniques.Recently,several authors have suggested that primary arthroplasty could be a viable alternative option to standard fixation techniques in selected patients with complex distal femur fractures.AIM To present our experience with 11 cases of distal femur fractures treated with knee arthroplasty and large femoral resection in a population of patients over the age of 85.METHODS Data from 11 consecutive patients(10 females,1 male)presenting with acute intra-articular supracondylar or intercondylar distal femur fractures and with pre-existent primary osteoarthritis who were treated with primary knee arthroplasty were recorded.We collected standard demographic data,comorbidities and patient reported outcomes including Visual Analogical Scale(VAS),Oxford Knee Score(OKS)and Barthel’s Index.Post-operative joint range of motion(ROM)and standard radiographic data were also collected.RESULTS At a mean follow-up of 23.2 mo,all of the implants were well-positioned and osteointegrated.Furthermore,all the patients were alive and walking either independently or with walking aids.There was a marked improvement in pain(VAS 4.5 postop vs 1.9 at the last follow-up),OKS score(29.5 postop vs 36.81 at the last follow-up),ROM(96.2°postop vs 102°at the last follow-up)and restoration of pre-injury ambulatory status(average Barthel Index 77.3).The radiographic evaluations showed good restoration of the articular geometry.No deaths and no complications were recorded.CONCLUSION In conclusion,we believe that knee megaprosthesis in the case of complex fractures of the distal femur is a valid surgical choice.This is particularly true in elderly patients with severe osteoporosis and pre-existing osteoarthritis.It is important to note that this surgery should be performed by surgeons with proven experience in prosthetic hip and knee surgery and that a scrupulous selection of the cases is completed.
基金Special Project for Seedling Cultivation funded by Special Fund of Chinese Central Government for Basic Scientific Research Operations in Commonweal Research Institutes(No.ZZ11-084)。
文摘Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,VIP and Wanfang,were searched for the original study.Literature was screened according to the inclusion and exclusion criteria,and the methodological quality of the included studies was evaluated by Cochrane risk bias assessment tool.The software Revman 5.4 was used for data analysis.Results:A total of 19 studies were included in the study.The clinical effective rate of the plate group[RR=0.96,95%CI(0.93,0.99),P=0.007],Radial inclination[MD=-1.85,95%CI(-2.93,-0.77),P=0.0008],Ulnar inclination[MD=-2.49,95%CI(-3.95,-1.04),P=0.0007],relative height of radius[MD=-1.63,95%CI(-2.40,-0.86),P<0.0001]were better than those in small splints group.There was no significant difference in fracture healing time[MD=-4.39,95%CI(-9.07,0.28),P=0.07]and complications[RR=1.57,95%CI(0.98,2.52),P=0.06]between the two groups.In terms of treatment cost[MD=-2.83,95%CI(-3.37,-2.30),P<0.00001],the small splint group was better than the plate treatment group.Conclusion:Compared with small splints therapy,plate internal fixation has advantages in clinical effective rate and imaging scores.There is no significant difference in fracture healing time and complications between the two groups.In terms of treatment cost,small splint therapy is better than plate therapy.Clinical treatment should be selected and formulated according to the individual situation,demands and clinical practice of patients.
文摘BACKGROUND Distal radius fractures(DRFs)are a common challenge in orthopaedic trauma care,yet for those fractures that are treated nonoperatively,strong evidence to guide cast treatment is still lacking.AIM To compare the efficacy of below elbow cast(BEC)and above elbow cast(AEC)in maintaining reduction of manipulated DRFs.METHODS We conducted a prospective,monocentric,randomized,parallel-group,open label,blinded,noninferiority trial comparing the efficacy of BEC and AEC in the nonoperative treatment of DRFs.Two hundred and eighty patients>18 years of age diagnosed with DRFs were successfully randomized and included for analysis over a 3-year period.Noninferiority thresholds were defined as a 2 mm difference for radial length(RL),a 3°difference for radial inclination(RI),and volar tilt(VT).The trial is registered at Clinicaltrials.gov(NCT03468023).RESULTS One hundred and forty-three patients were treated with BEC,and 137 were treated with AEC.The mean time of immobilization was 33 d.The mean loss of RL,RI,and VT was 1.59 mm,2.83°,and 4.11°for BEC and 1.63 mm,2.54°,and VT loss were respectively 0.04 mm(95%CI:-0.36-0.44),-0.29°(95%CI:-1.03-0.45),and 0.59°(95%CI:-1.39-2.57),and they were all below the prefixed noninferiority thresholds.The rate of loss of reduction was similar.CONCLUSION BEC performs as well as AEC in maintaining the reduction of a manipulated DRF.Being more comfortable to patients,BEC may be preferable for nonoperative treatment of DRFs.
文摘Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.
文摘Distal radius fractures are common and while historically most have been treated nonoperatively the frequency with which distal radius fractures are treated surgically is increasing. Criteria for considering surgical treatment are often based on radiographic appearance of the fracture. Less often discussed is patient preference: what do patients want. We investigated responses of a general population when presented with various treatment options following a hypothetical distal radius fracture. Many respondents chose nonoperative treatment even when told that surgery might result in a better outcome. This information can help during the shared decision-making process when discussing treatment options with a patient who presents with a distal radius fracture.
文摘To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab.
文摘BACKGROUND Neonatal distal humeral physeal fractures are rare and difficult to diagnose.Thus,missed diagnoses and delayed healing are possible.Few studies have reported surgical treatment,because a callus may develop at the fracture site 5 d after the fracture,resulting in difficult reduction,and reduction of the limb may cause further physeal injury.Other surgical challenges include the provision of adequate anesthesia and complexity of the operation.However,without appropriate reduction and fixation,a varus elbow deformity may develop.Manual reduction and percutaneous pin fixation are ideal treatment options.CASE SUMMARY A 4-day-old neonate with left elbow pain accompanied by limited movement for 4 d was admitted,and diagnosed with delayed physeal fracture of the distal humerus based on physical examination,ultrasonography,and magnetic resonance imaging.The patient was treated by manual reduction combined with percutaneous pin fixation under arthrography.Postoperatively,the reduction was successful.The upper limbs could have been lifted and the fingers could have been moved freely on the second day after the operation.CONCLUSION The techniques of manual reduction and percutaneous pin fixation,to treat neonatal distal humeral physeal fractures,are safe and reliable.
文摘Background L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation.Repair of the PQ muscle was always recommended at the end of operation for some instructive reasons.But repair of PQ is not satisfied because of poor quality of muscle and fascial tissues which may cause pain or impede forearm pronation and supination for post-operative scarring around PQ.Inserting the locking palmar plate to pass under the pronator quadratus muscle and the locking screws are inserted through miniincisions in pronator quadratus in some patients with distal radius fractures is a reasonable technique which can preserve the pronator quadratus.The purpose of this study was to evaluate and compare the clinical effects after volar plating of the distal radius fractures while preserving the pronator quadratus and pronator quadratus repair.Methods Between September 2010 and April 2012,65 patients (42 males and 23 females; aged 20-68 years and a mean age of 42.5 years) with distal radius fracture underwent open reduction and internal fixation using the volar locking palmar plates (Depuy or Smith companies).The patients were classified as 23A-2 through 23C-3 according to the Orthopaedic Trauma Association (OTA) classifications.All surgeries were completed by the same trained team.The volar locking palmar plates of distal radius performed with preserving pronator quadratus group involved 30 patients including 19 males and 11 females and performed with pronator quadratus repair group involved 35 patients including 23 males and 12 females.We compared the two groups for wrist pain,forearm range of motion,grip strength,pedoperative complications and wrist functional recovery score.Results The minimum follow-up for the whole cohort was one year.The differences between the two groups were significant with regard to wrist pain,forearm range of motion,grip strength and wrist function at 1,2,and 6 weeks postoperatively,but insignificant at 6 and 12 months postoperatively.No significant differences were found in the pedoperative complications and radiographs postoperatively.Conclusions Preservation of the pronator quadratus muscle is a satisfactory method for the treatment of majority of the fractures of the distal radius with volar locking palmar plates,as this technique can yield better early wrist function and shorten the rehabilitation.