For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of th...For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.展开更多
The sparse distribution characteristics of renewable energy resources can lead to there being tens of kilometers of transmission lines between a grid-connected inverter and the actual grid.Accurate analysis of the sta...The sparse distribution characteristics of renewable energy resources can lead to there being tens of kilometers of transmission lines between a grid-connected inverter and the actual grid.Accurate analysis of the stability of such gridconnected inverter systems currently involves using a complex hyperbolic function to shaped model of the transmission line circuit.This has proved to be problematic,so,drawing upon the distribution parameter characteristics of transmission lines,this paper looks at how to use impedance-based stability criteria to assess the stability of multi-paralleled grid-connected inverters.First,the topology of multi-paralleled inverters connected to the grid via transmission lines is established,using each transmission line terminal as a grid connection point.Each grid-connected system is taken to be equivalent to a small-signal circuit model of the“current source-grid”.Euler’s formula and the Nyquist stability criterion are combined to assess the stability of the associated grid-connected current transfer functions and evaluate the stability of the grid-connected current.Finally,a simulation analysis circuit is constructed to verify whether power line intervention will cause stability problems in the grid-connected system.Overall,it is found that long-distance transmission lines are more likely to cause unstable output of the grid-connected current.It is also found that the number of grid-connected inverters,the short-circuit ratio(SCR),the distorted grid and the inverter parameters can all have a significant impact on the stability of the grid-connected current.展开更多
Precise fault location plays an important role in the reliability of modern power systems.With the in-creasing penetration of renewable energy sources,the power system experiences a decrease in system inertia and alte...Precise fault location plays an important role in the reliability of modern power systems.With the in-creasing penetration of renewable energy sources,the power system experiences a decrease in system inertia and alterations in steady-state characteristics following a fault occurrence.Most existing single-ended phasor domain methods assume a certain impedance of the remote-end system or consistent current phases at both ends.These problems present challenges to the applicability of con-ventional phasor-domain location methods.This paper presents a novel single-ended time domain fault location method for single-phase-to-ground faults,one which fully considers the distributed parameters of the line model.The fitting of transient signals in the time domain is real-ized to extract the instantaneous amplitude and phase.Then,to eliminate the error caused by assumptions of lumped series resistance in the Bergeron model,an im-proved numerical derivation is presented for the distrib-uted parameter line model.The instantaneous symmet-rical components are extracted for decoupling and inverse transformation of three-phase recording data.Based on the above,the equation of instantaneous phase constraint is established to effectively identify the fault location.The proposed location method reduces the negative effects of fault resistance and the uncertainty of remote end pa-rameters when relying on one-terminal data for localiza-tion.Additionally,the proposed fault analysis methods have the ability to adapt to transient processes in power systems.Through comparisons with existing methods in three different systems,the fault position is correctly identified within an error of 1%.Also,the results are not affected by sampling rates,data windows,fault inception angles,and load conditions. Index Terms—Fault location,distributed parameter line model,transient signal,renewable energy,instantaneous phase.展开更多
文摘For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.
文摘The sparse distribution characteristics of renewable energy resources can lead to there being tens of kilometers of transmission lines between a grid-connected inverter and the actual grid.Accurate analysis of the stability of such gridconnected inverter systems currently involves using a complex hyperbolic function to shaped model of the transmission line circuit.This has proved to be problematic,so,drawing upon the distribution parameter characteristics of transmission lines,this paper looks at how to use impedance-based stability criteria to assess the stability of multi-paralleled grid-connected inverters.First,the topology of multi-paralleled inverters connected to the grid via transmission lines is established,using each transmission line terminal as a grid connection point.Each grid-connected system is taken to be equivalent to a small-signal circuit model of the“current source-grid”.Euler’s formula and the Nyquist stability criterion are combined to assess the stability of the associated grid-connected current transfer functions and evaluate the stability of the grid-connected current.Finally,a simulation analysis circuit is constructed to verify whether power line intervention will cause stability problems in the grid-connected system.Overall,it is found that long-distance transmission lines are more likely to cause unstable output of the grid-connected current.It is also found that the number of grid-connected inverters,the short-circuit ratio(SCR),the distorted grid and the inverter parameters can all have a significant impact on the stability of the grid-connected current.
文摘Precise fault location plays an important role in the reliability of modern power systems.With the in-creasing penetration of renewable energy sources,the power system experiences a decrease in system inertia and alterations in steady-state characteristics following a fault occurrence.Most existing single-ended phasor domain methods assume a certain impedance of the remote-end system or consistent current phases at both ends.These problems present challenges to the applicability of con-ventional phasor-domain location methods.This paper presents a novel single-ended time domain fault location method for single-phase-to-ground faults,one which fully considers the distributed parameters of the line model.The fitting of transient signals in the time domain is real-ized to extract the instantaneous amplitude and phase.Then,to eliminate the error caused by assumptions of lumped series resistance in the Bergeron model,an im-proved numerical derivation is presented for the distrib-uted parameter line model.The instantaneous symmet-rical components are extracted for decoupling and inverse transformation of three-phase recording data.Based on the above,the equation of instantaneous phase constraint is established to effectively identify the fault location.The proposed location method reduces the negative effects of fault resistance and the uncertainty of remote end pa-rameters when relying on one-terminal data for localiza-tion.Additionally,the proposed fault analysis methods have the ability to adapt to transient processes in power systems.Through comparisons with existing methods in three different systems,the fault position is correctly identified within an error of 1%.Also,the results are not affected by sampling rates,data windows,fault inception angles,and load conditions. Index Terms—Fault location,distributed parameter line model,transient signal,renewable energy,instantaneous phase.