Intelligent distribution automation system (IDAS) was developed based on distribution automation system that was installed in all distribution offices of Korea. IDAS was designed the combined system with the functio...Intelligent distribution automation system (IDAS) was developed based on distribution automation system that was installed in all distribution offices of Korea. IDAS was designed the combined system with the function of supervisory control and data acquisition (SCADA) and distribution automation system (DAS) for network operation from substation to high voltage customer, and it has been installed in Vietnam, China and Indonesia. This paper explains the project scope, system configuration, and the function of each sy stem.展开更多
Advanced Metering Infrastructure(AMI)forms an important part in Smart Grids.Routing the data effectively from smart meters to the Edge/Fog node requires an efficient routing protocol.Routing Protocol for Low Power Los...Advanced Metering Infrastructure(AMI)forms an important part in Smart Grids.Routing the data effectively from smart meters to the Edge/Fog node requires an efficient routing protocol.Routing Protocol for Low Power Lossy Area Network(RPL)is a standard routing protocol for IPv6 over Low Power Personal Area Network(6LoWPAN).In a Power Distribution system all the smart meters together form 6LoWPAN network.They communicate with the fog router,which acts as the 6LoWPAN gateway.ContikiRPL was evaluated using Cooja Network simulator for a power distribution network topology.The nodes which were far away from the fog node gave low Packet Delivery Ratio(PDR)and large End to End delay.This paper proposes an aggregation RPL scheme by modifying the existing Contiki RPL.The smart meter nodes communicate to the aggregator,which communicates to the fog node.The results show that the aggregation scheme has 35.6%increase in PDR,lesser hop count and 13.24%decrease in End to End delay on an average compared to existing RPL.展开更多
A future smart grid must fulfill the vision of the Energy Internet in which millions of people produce their own energy from renewables in their homes, offices, and factories and share it with each other. Electric veh...A future smart grid must fulfill the vision of the Energy Internet in which millions of people produce their own energy from renewables in their homes, offices, and factories and share it with each other. Electric vehicles and local energy storage will be widely deployed. Internet technology will be utilized to transform the power grid into an energysharing inter-grid. To prepare for the future, a smart grid with intelligent periphery, or smart GRIP, is proposed. The building blocks of GRIP architecture are called clusters and include an energy-management system (EMS)-controlled transmission grid in the core and distribution grids, micro-grids, and smart buildings and homes on the periphery; all of which are hierarchically structured. The layered architecture of GRIP allows a seamless transition from the present to the future and plug-and-play interoperability. The basic functions of a cluster consist of (1) dispatch, (2) smoothing, and (3) mitigation. A risk-limiting dispatch methodology is presented; a new device, called the electric spring, is developed for smoothing out fluctuations in periphery clusters; and means to mitigate failures are discussed.展开更多
The new reality of smart distribution systems with use of generation sources of small and medium sizes brings new challenges for the operation of these systems. The complexity and the large number of nodes requires us...The new reality of smart distribution systems with use of generation sources of small and medium sizes brings new challenges for the operation of these systems. The complexity and the large number of nodes requires use of methods which can reduce the processing time of algorithms such as power flow, allowing its use in real time. This paper presents a known methodology for calculating the power flow in three phases using backward/forward sweep method, and also considering other network elements such as voltage regulators, shunt capacitors and sources of dispersed generation of types PV (active power and voltage) and PQ (active and reactive power). After that, new elements are introduced that allow the parallelization of this algorithm and an adequate distribution of work between the available processors. The algorithm was implemented using a multi-tiered architecture; the processing times were measured in many network configurations and compared with the same algorithm in the serial version.展开更多
The CIM (common information model) is an abstract information model that can be used to model an electrical network and various equipments used on the network. By using a common model, utilities and vendors can redu...The CIM (common information model) is an abstract information model that can be used to model an electrical network and various equipments used on the network. By using a common model, utilities and vendors can reduce their integration costs, which should allow more resources to be applied toward increased functionality for managing and optimizing the electrical system. As a part of smart grid, the SPG (smart power grid) was built on Jeju Island. The SPG consists of IDAS (intelligent distribution automation system), substation automation system, intelligent transmission system, and active telemetrics system. To integrate these systems which have different operating systems and platforms CIM standard was used. But IDAS has many functions and advanced algorithms not defined in CIM. In this paper, the authors introduce how to develop and extend the CIM model for managing the IDAS.展开更多
An adjacent table-based simplified model of distribution networks containing medium voltage buses of a substation is established.Identification of bus outage and the condition to start fast restoration procedure are d...An adjacent table-based simplified model of distribution networks containing medium voltage buses of a substation is established.Identification of bus outage and the condition to start fast restoration procedure are discussed.A complex load shading parameter is set up to describe various load shading schemes.The imaginary part of the load shading parameter describes the states of switches of load shading schemes while the real part is the corresponding amount of shaded load.A new concept of independent tripping operation is also put forward.The procedure to search the operation with the least amount of shaded load for a feeder and a connected domain are detailed.The procedure for fast restoration of a large area breakdown of the whole distribution network under emergency states is dealt with using a typical grid distribution network as an example.Results of analysis show that the direct load shading scheme under the most balanced topology is not always the optimal scheme.The proposed method can obtain the optimal operating mode with the least amount of shaded load thus showing its feasibility.展开更多
With the rapid development of local generation and demand response,the active distribution network(ADN),which aggregates and manages miscellaneous distributed resources,has moved from theory to practice.Secure and opt...With the rapid development of local generation and demand response,the active distribution network(ADN),which aggregates and manages miscellaneous distributed resources,has moved from theory to practice.Secure and optimal operations now require an advanced situation awareness(SA)system so that operators are aware of operation states and potential risks.Current solutions in distribution supervisory control and data acquisition(DSCADA)as well as the distribution automation system(DAS)generally are not able to meet the technology requirements of SA.In this paper,the authors’participation in the project of developing an SA system as the basic component of a practical active distribution management system(ADMS)deployed in Beijing,China,is presented.This paper reviews the ADN’s development roadmap by illustrating the changes that are made in elements,topology,structure,and control scheme.Taking into consideration these hardware changes,a systematic framework is proposed for the main components and the functional hierarchy of an SA system for the ADN.The SA system’s implementation bottlenecks are also presented,including,but not limited to issues in big data platform,distribution forecasting,and security evaluation.Potential technology solutions are also provided.展开更多
文摘Intelligent distribution automation system (IDAS) was developed based on distribution automation system that was installed in all distribution offices of Korea. IDAS was designed the combined system with the function of supervisory control and data acquisition (SCADA) and distribution automation system (DAS) for network operation from substation to high voltage customer, and it has been installed in Vietnam, China and Indonesia. This paper explains the project scope, system configuration, and the function of each sy stem.
基金National Funding from the FCT- Fundacao Para a Ciencia e a Tecnologia through the UID/ EEA/50008/2019 Project by Brazilian National Council for Scientific and Technological Development via Grant No. 309335/2017-5
文摘Advanced Metering Infrastructure(AMI)forms an important part in Smart Grids.Routing the data effectively from smart meters to the Edge/Fog node requires an efficient routing protocol.Routing Protocol for Low Power Lossy Area Network(RPL)is a standard routing protocol for IPv6 over Low Power Personal Area Network(6LoWPAN).In a Power Distribution system all the smart meters together form 6LoWPAN network.They communicate with the fog router,which acts as the 6LoWPAN gateway.ContikiRPL was evaluated using Cooja Network simulator for a power distribution network topology.The nodes which were far away from the fog node gave low Packet Delivery Ratio(PDR)and large End to End delay.This paper proposes an aggregation RPL scheme by modifying the existing Contiki RPL.The smart meter nodes communicate to the aggregator,which communicates to the fog node.The results show that the aggregation scheme has 35.6%increase in PDR,lesser hop count and 13.24%decrease in End to End delay on an average compared to existing RPL.
基金sponsored by National Key Basic Research Program of China (973 Program) (2012CB215102) for WuUS National Science Foundation Award (1135872) for VaraiyaHong Kong RGC Theme-based Research Project (T23-701/14-N) for Hui
文摘A future smart grid must fulfill the vision of the Energy Internet in which millions of people produce their own energy from renewables in their homes, offices, and factories and share it with each other. Electric vehicles and local energy storage will be widely deployed. Internet technology will be utilized to transform the power grid into an energysharing inter-grid. To prepare for the future, a smart grid with intelligent periphery, or smart GRIP, is proposed. The building blocks of GRIP architecture are called clusters and include an energy-management system (EMS)-controlled transmission grid in the core and distribution grids, micro-grids, and smart buildings and homes on the periphery; all of which are hierarchically structured. The layered architecture of GRIP allows a seamless transition from the present to the future and plug-and-play interoperability. The basic functions of a cluster consist of (1) dispatch, (2) smoothing, and (3) mitigation. A risk-limiting dispatch methodology is presented; a new device, called the electric spring, is developed for smoothing out fluctuations in periphery clusters; and means to mitigate failures are discussed.
文摘The new reality of smart distribution systems with use of generation sources of small and medium sizes brings new challenges for the operation of these systems. The complexity and the large number of nodes requires use of methods which can reduce the processing time of algorithms such as power flow, allowing its use in real time. This paper presents a known methodology for calculating the power flow in three phases using backward/forward sweep method, and also considering other network elements such as voltage regulators, shunt capacitors and sources of dispersed generation of types PV (active power and voltage) and PQ (active and reactive power). After that, new elements are introduced that allow the parallelization of this algorithm and an adequate distribution of work between the available processors. The algorithm was implemented using a multi-tiered architecture; the processing times were measured in many network configurations and compared with the same algorithm in the serial version.
文摘The CIM (common information model) is an abstract information model that can be used to model an electrical network and various equipments used on the network. By using a common model, utilities and vendors can reduce their integration costs, which should allow more resources to be applied toward increased functionality for managing and optimizing the electrical system. As a part of smart grid, the SPG (smart power grid) was built on Jeju Island. The SPG consists of IDAS (intelligent distribution automation system), substation automation system, intelligent transmission system, and active telemetrics system. To integrate these systems which have different operating systems and platforms CIM standard was used. But IDAS has many functions and advanced algorithms not defined in CIM. In this paper, the authors introduce how to develop and extend the CIM model for managing the IDAS.
文摘An adjacent table-based simplified model of distribution networks containing medium voltage buses of a substation is established.Identification of bus outage and the condition to start fast restoration procedure are discussed.A complex load shading parameter is set up to describe various load shading schemes.The imaginary part of the load shading parameter describes the states of switches of load shading schemes while the real part is the corresponding amount of shaded load.A new concept of independent tripping operation is also put forward.The procedure to search the operation with the least amount of shaded load for a feeder and a connected domain are detailed.The procedure for fast restoration of a large area breakdown of the whole distribution network under emergency states is dealt with using a typical grid distribution network as an example.Results of analysis show that the direct load shading scheme under the most balanced topology is not always the optimal scheme.The proposed method can obtain the optimal operating mode with the least amount of shaded load thus showing its feasibility.
基金supported by National High-Technology Research and Development Program(“863”Program)of China(2014AA051901)International S&T Cooperation Program of China(2014DFG62670)+1 种基金National Natural Science Foundation of China(51261130472,51577096)China Postdoctoral Science Foundation(2015M580097).
文摘With the rapid development of local generation and demand response,the active distribution network(ADN),which aggregates and manages miscellaneous distributed resources,has moved from theory to practice.Secure and optimal operations now require an advanced situation awareness(SA)system so that operators are aware of operation states and potential risks.Current solutions in distribution supervisory control and data acquisition(DSCADA)as well as the distribution automation system(DAS)generally are not able to meet the technology requirements of SA.In this paper,the authors’participation in the project of developing an SA system as the basic component of a practical active distribution management system(ADMS)deployed in Beijing,China,is presented.This paper reviews the ADN’s development roadmap by illustrating the changes that are made in elements,topology,structure,and control scheme.Taking into consideration these hardware changes,a systematic framework is proposed for the main components and the functional hierarchy of an SA system for the ADN.The SA system’s implementation bottlenecks are also presented,including,but not limited to issues in big data platform,distribution forecasting,and security evaluation.Potential technology solutions are also provided.