A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filte...A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations.展开更多
Monitoring and classifying disturbed forests can provide information support for not only sustainable forest management but also global carbon sequestration assessments.In this study,we propose an autoencoder-based mo...Monitoring and classifying disturbed forests can provide information support for not only sustainable forest management but also global carbon sequestration assessments.In this study,we propose an autoencoder-based model for forest disturbance detection,which considers disturbances as anomalous events in forest temporal trajectories.The autoencoder network is established and trained to reconstruct intact forest trajectories.Then,the disturbance detection threshold is derived by Tukey’s method based on the reconstruction error of the intact forest trajectory.The assessment result shows that the model using the NBR time series performs better than the NDVIbased model,with an overall accuracy of 90.3%.The omission and commission errors of disturbed forest are 7%and 12%,respectively.Additionally,the trained NBR-based model is implemented in two test areas,with overall accuracies of 87.2%and 86.1%,indicating the robustness and scalability of the model.Moreover,comparing three common methods,the proposed model performs better,especially for intact forest detection accuracy.This study provides a novel and robust approach with acceptable accuracy for forest disturbance detection,enabling forest disturbance to be identified in regions with limited disturbance reference data.展开更多
A flow measurement system consisting of an optical fiber Fabry–Perot(F-P) sensor and an elbow tube is proposed and demonstrated to realize flow measurements and eliminate thermal disturbance.Two F-P sensors are sym...A flow measurement system consisting of an optical fiber Fabry–Perot(F-P) sensor and an elbow tube is proposed and demonstrated to realize flow measurements and eliminate thermal disturbance.Two F-P sensors are symmetrically mounted on the inner-wall surface of the elbow of 90° in order to eliminate the effect of thermal disturbance to the flow measurement accuracy.Experimental results show that the absolute phase difference is the square root of the fluid flow.It is consistent with the theoretical analysis,which proves that the flow measurement method can measure flow and eliminate the influence of thermal disturbance simultaneously.展开更多
基金Project supported by the Innovation Program of Education Commission of Shanghai Municipality (Grant No.10YZ19)the Shanghai Leading Academic Discipline Project (Grant No.S30108)the Shanghai Key Laboratory of Specialty Fiber Optics and Optical Access Networks (Grant No.SKLSFO200903)
文摘A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations.
基金funded by the National Natural Science Foundation of China under Grant 41871223the China Scholarship Council(CSC)(No.201806400048)for doctoral scholarship support.
文摘Monitoring and classifying disturbed forests can provide information support for not only sustainable forest management but also global carbon sequestration assessments.In this study,we propose an autoencoder-based model for forest disturbance detection,which considers disturbances as anomalous events in forest temporal trajectories.The autoencoder network is established and trained to reconstruct intact forest trajectories.Then,the disturbance detection threshold is derived by Tukey’s method based on the reconstruction error of the intact forest trajectory.The assessment result shows that the model using the NBR time series performs better than the NDVIbased model,with an overall accuracy of 90.3%.The omission and commission errors of disturbed forest are 7%and 12%,respectively.Additionally,the trained NBR-based model is implemented in two test areas,with overall accuracies of 87.2%and 86.1%,indicating the robustness and scalability of the model.Moreover,comparing three common methods,the proposed model performs better,especially for intact forest detection accuracy.This study provides a novel and robust approach with acceptable accuracy for forest disturbance detection,enabling forest disturbance to be identified in regions with limited disturbance reference data.
基金supported by the National Instrumentation Program of China(No.2013YQ030915)the National Natural Science Foundation of China(Nos.61675152,61227011,61378043,61475114,61505139,and 61505138)+2 种基金the open project of Key Laboratory of Micro Opto-electro Mechanical System Technology,Tianjin University,Ministry of Education(No.MOMST2016-3)the Shenzhen Science and Technology Research Project(No.JCYJ20120831153904083)the SEM Soft Science Research and Development Project of Ministry of Housing and Urban-Rural Development of China(No.2016-K4-087)
文摘A flow measurement system consisting of an optical fiber Fabry–Perot(F-P) sensor and an elbow tube is proposed and demonstrated to realize flow measurements and eliminate thermal disturbance.Two F-P sensors are symmetrically mounted on the inner-wall surface of the elbow of 90° in order to eliminate the effect of thermal disturbance to the flow measurement accuracy.Experimental results show that the absolute phase difference is the square root of the fluid flow.It is consistent with the theoretical analysis,which proves that the flow measurement method can measure flow and eliminate the influence of thermal disturbance simultaneously.