期刊文献+
共找到1,278篇文章
< 1 2 64 >
每页显示 20 50 100
The Changes of Left Ventricular Form and Function After Closure of Moderate-to Large-sized Patent Ductus Arteriosus Using Domestic-made Occluder
1
作者 莫剑梅 伍伟锋 +4 位作者 刘唐威 黄凯 郭盛兰 张炳东 吴棘 《South China Journal of Cardiology》 CAS 2005年第2期106-108,共3页
Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underw... Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underwent procedure successfuly using the domestic-made occluder. The mean PDA minimal (pulmonary end) diameter by aortography was 8.01±2.47 mm (range 4 to 15.5mm). All patients underwent transthoracic echocardiography (TTE) study before the procedure and the following 48 hours, 3 months after procedure. Results All patients had been implanted the domestic-made occluders successfully with no haematolysis, infective endocarditis, recanalization and other complications. At 3 months, mean LVED was decreased to 50.05±6.55 mm, compared to the pre-procedure (55.67 ±8.48 mm), P 〈 0.01. After 48 hours of the procedure, mean LVEDD and LVESD decreased significantly (156.22± 51.40 mL vs. 121.28±35.73ml, 57.16±32.07 mL vs. 45.88±15.97 mL), P〈 0.05. At 3 months, LVEDD decreased to 110.93 ±15.08ml, LVSV reached 73.50± 9.19 mL, compared to the pre-procedure, P 〈 0.01. LVESD decreased to 37.43±10.44 mL at 3 months, P〈 0.05. Conclusions Closuring of moderate- to largesized PDA using domestic-made occluder is effective and safe. After procedure, left ventricular form and function improved. 展开更多
关键词 Patent ductus arteriosus Heart catheterization occluder device
下载PDF
Left atrial appendage occluder detachment treated with transthoracic ultrasound combined with digital subtraction angiography guided catcher:A case report
2
作者 Kai Yu Yun-Hua Mei 《World Journal of Clinical Cases》 SCIE 2024年第6期1157-1162,共6页
BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innova... BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innovatively used ultrasound guidance combined with digital subtraction angiography(DSA)to completely remove the occluder,accumulating some experience.CASE SUMMARY The patient underwent left atrial appendage occlusion surgery in our hospital due to atrial fibrillation.After the surgery,the occluder fell off and became free in the left ventricle,which is very dangerous.We innovatively used ultrasound guidance,combined with DSA,and interventional surgery to successfully capture the free occluder using a catcher,completely remove it,and then re implant a new left atrial appendage occluder.After the surgery,the patient recovered very well.CONCLUSION The size selection of the occluder is slightly conservative,and the shape of the left atrial appendage opening is irregular. 展开更多
关键词 Left atrial appendage occluder DETACHMENT Ultrasound combined with digital subtraction angiography Interventional operation Successfully captured Case report
下载PDF
Welding of shape memory alloy to stainless steel for medical occluder 被引量:3
3
作者 吕世雄 杨仲林 董红刚 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2013年第1期156-160,共5页
Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld... Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld was welded to a stainless steel pipe with laser spot welding process.The microstructure of the welds was examined with an optical microscope and the elemental distribution in the welds was measured by electron probe microanalysis(EPMA).The results show that TiC compounds dispersively distribute in the NiTi SMA TIG weld.However,the amount of TiC compounds greatly decreases around the fusion boundary of the laser spot weld between the NiTi SMA and stainless steel.Mutual diffusion between NiTi shape memory alloy and stainless steel happen within a short distance near the fusion boundary,and intermetallic compounds such as Ni3Ti+(Fe,Ni)Ti appear around the fusion boundary. 展开更多
关键词 medical occluder NiTi alloy shape memory alloy stainless steel laser spot welding dissimilar metal joining Ni3Ti (Fe Ni)Ti
下载PDF
Safety of an improved patent ductus arteriosus occluder for transcatheter closure of perimembranous ventricular septal defects with abnormally attached tricuspid chordae tendineae 被引量:2
4
作者 Lu He Ya-Juan Du +1 位作者 Ge-Sheng Cheng Yu-Shun Zhang 《World Journal of Clinical Cases》 SCIE 2019年第5期562-571,共10页
BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid r... BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid regurgitation(TR),associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable.AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus(PDA) occluder.METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed.RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted. 展开更多
关键词 Ventricular SEPTAL defect TRANSCATHETER PATENT ductus arteriosus occlude TRICUSPID REGURGITATION Chordae tendineae
下载PDF
Safety and efficacy of amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up 被引量:1
5
作者 Muhammad Dilawar Zaheer Ahmad 《World Journal of Cardiovascular Diseases》 2013年第2期228-233,共6页
Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventric... Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventricular septal defects with tunnel shape aneurysm closure using the Amplatzer duct occluder. Materials and Methods: From May 2006-December 2012, we used Amplatzer duct occluder in seven ventricular septal defect patients here atHamad General Hospital,Doha,Qatar. There were 4 male and 3 female patients with an age range of 4 - 32 years with a median of 8 years and weight range of 16 - 63 kgwith a median of33 kg. In this group, 6 were perimembranous and 1 muscular and all these ventricular septal defects had a tunnel shape aneurysm. Transesophageal echocardiographic diameter ranged from 4 - 8 mmand Qp/Qs was 1 - 1.6. Angiographically, the diameter on the left ventricular side measured 3.5 - 10 mmand on right ventricular side 2.4?- 5 mm. 8/6 mmAmplatzer duct occluder was used to close these ventricular septal defects. Results: There were no major complications and immediately after the procedure there was no residual shunt in any of these patients and all the patients remained in normal sinus rhythm. One patient was expatriate and no further follow up was available. The rest of the 6 patients had 1 - 80 months with a median of 54 months follow up and none of these patients had any residual shunt and all remained in normal sinus rhythm. Two patients developed trivial aortic valve regurgitation immediate post procedure, one remained unchanged and the 2nd has progressed to mild at this latest follow up. Conclusion: Amplatzer duct occluder is feasible and a safe device for percutaneous closure of selective tunnel shape aneurysmal perimembranous and muscular ventricular septal defects. 展开更多
关键词 VENTRICULAR SEPTAL Defect AMPLATZER DUCT occluder ANEURYSM
下载PDF
Completed atrioventricular block induced by atrial septal defect occluder unfolding:A case report 被引量:1
6
作者 Chuan He Yang Zhou +2 位作者 Si-Si Tang Li-Hong Luo Kun Feng 《World Journal of Clinical Cases》 SCIE 2020年第22期5715-5721,共7页
BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial se... BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial septal defects(ASDs).CASE SUMMARY A 30-year-old female patient was diagnosed with ASD by transthoracic echocardiography(TTE)1 year ago.The electrocardiogram showed a heart rate of 88 beats per minute,normal sinus rhythm,and no change in the ST-T wave.After admission,TTE showed an atrial septal defect with a left-to-right shunt,aortic root short-axis section with an ASD diameter of 8 mm,a parasternal four-chamber section with an ASD diameter of 9 mm,and subxiphoid biatrial section with a diameter of 13 mm.Percutaneous occlusion was proposed.The intraoperative TTE scan showed that the atrial septal defect was oval in shape,was located near the root of the aorta,and had a maximum diameter of 13 mm.A 10-F sheath was placed in the right femoral vein,and a 0.035°hard guidewire was used to establish the transport track between the left pulmonary vein and the inferior vena cava.A shape-memory alloy atrial septal occluder with a waist diameter of 20 mm was placed successfully and located correctly.TTE showed that the double disk unfolded well and that the clamping of the atrial septum was smooth.Immediately after the disc was revealed,electrocardiograph monitoring showed that the ST interval of the inferior leads was prolonged,the P waves and QRS waves were separated,a junctional escape rhythm maintained the heart rate,and the blood pressure began to decrease.After removing the occluder,the elevation in the ST segment returned to normal immediately,and the sinus rhythm returned to average approximately 10 min later.After consulting the patient’s family,we finally decided to withdraw from the operation.CONCLUSION Compression of the small coronary artery,which provides an alternative blood supply to the atrioventricular nodule during the operation,leads to the emergence of a complete atrioventricular block. 展开更多
关键词 Completed atrioventricular block Atrial septal defect occluder Atrial septal defect Transthoracic echocardiography Case report
下载PDF
Occlusion of atrial septal defect utilizing occluder devise via minimally invasive right chest approach
7
作者 励峰 李伟 +5 位作者 康宁 龚宝生 吴东进 徐方杰 邱兆昆 吴卫华 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2011年第3期343-345,共3页
Objective To evaluate atrial septal defect(ASD) occlusion employing a small right anterior thoracotomy approach. Methods A total of 21 patients with ASD underwent general anesthesia and 2-3 cm incision was made in the... Objective To evaluate atrial septal defect(ASD) occlusion employing a small right anterior thoracotomy approach. Methods A total of 21 patients with ASD underwent general anesthesia and 2-3 cm incision was made in the fourth right intercostal space.Utilizing transesophageal or transthoracic echocardiography,the occluder was released using a monotube unit. Results All patients were occluded successfully.No patient required open surgery utilizing extracorporeal circulation.There were no major complications and no evidence of residual atrial shunt. Conclusion ASD occlusion via a minimal surgical incision is safe,less invasive,and has excellent outcomes. 展开更多
关键词 minimally invasive atrial septal defect occluder device
下载PDF
Safety and Efficacy of Biodegradable Patent Foramen Ovale Occluder in Patients with Migraine:A Clinical Trial
8
作者 Xingbang Li Xuan Zheng +10 位作者 Bowen Jin Yunyan Li Yongyu Shao Xiaoxian Deng Dingyang Li Shanshan Li Hongmei Zhou Jie Zhang Xianya Zhang Qunshan Shen Gangcheng Zhang 《Congenital Heart Disease》 SCIE 2023年第3期373-385,共13页
Background:Transcatheter closure of patent foramen ovale(PFO)has been widely accepted as a highly effective way to treat high-risk PFO-related diseases.However,traditional non-degradable occluders made of metal alloys... Background:Transcatheter closure of patent foramen ovale(PFO)has been widely accepted as a highly effective way to treat high-risk PFO-related diseases.However,traditional non-degradable occluders made of metal alloys will permanently exist in the body,resulting in thrombosis,valve damage,hemolysis,arrhythmia,or other complications.The biodegradable PFO occluder developed by Shanghai Mallow Medical Instrument Co.,Ltd.,China can be fully absorbed and degrade into nontoxic ingredients,reducing postoperative complications.Objectives:To study the safety and efficacy of biodegradable PFO occluders in treating PFO.Methods:This single-center clinical trial collected 30 patients treated with a biodegradable PFO occluder.The follow-up period lasted 12 months to analyze the echocardiographic characteristics and headache relief through HIT-6 scores.Results:The immediate success rate was 100%,with no intraoperative severe occlusion-related complications.The contrast transcranial Doppler(cTCD)at 12 months showed that all patients’right-to-left shunts(RLS)were grade I or 0 with no serious postoperative complications,indicating the overall success rate was 100%.The biodegradable PFO occluder mostly degraded six months after the occlusion.Conclusion:PFO closure with a Mallow biodegradable occluder is safe and effective and has no severe complications. 展开更多
关键词 Patent foramen ovale biodegradable occluder transcatheter closure MIGRAINE COMPLICATIONS
下载PDF
Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Amplatzer Duct Occluder II
9
作者 Hongxiao Sun Gang Luo +2 位作者 Zhanhui Du Zhixian Ji Silin Pan 《Congenital Heart Disease》 SCIE 2021年第2期151-157,共7页
Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had... Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had attempted transcatheter closure using ADO II,seven of patients were used antegrade approach and six of them were used retrograde approach.Results:There were 8 males and 5 females,age from 1 to 7 years,weight from 10.5 to 31.0 kg,and VSD size from 2.0 to 4.0 mm.Procedure was successful in all cases with the outer diameter of the occluders ranging from 4 to 6 mm.No aortic,tricuspid regurgitation or residual shunt was found in the immediate ultrasound assessment.No arrhythmia was observed in the Holter monitoring 3 days after the intervention.Discharge echocardiography indicated complete shunt closure.No evidence of occluder prolapse,malignant arrhythmia,or intensed valve regurgitation was seen on a median follow-up of 18 months(range,6 to 36 months).Conclusions:Based on our experience,ADO II showed good efficacy in the early and middle stages of pediatric pmVSD closures. 展开更多
关键词 Ventricular septal defect transcatheter closure Amplatzer duct occluder CHILDREN
下载PDF
Transcatheter Closure of a Right Pulmonary Artery to Left Atrium Fistula Using a Ventricular Septal Defect Occluder
10
作者 Diqi Zhu Xiaohong Gu +1 位作者 Jie Shen Fen Li 《Congenital Heart Disease》 SCIE 2021年第2期147-150,共4页
Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen sat... Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen saturation of 70%at admission.The echocardiogram indicated an abnormal color flow Doppler in the LA and she underwent standard cardiac catheterization.The angiography of pulmonary artery revealed a 7.4 mm×7.6 mm fistula between the RPA and LA and achieved successful closure using ventricular septal defect occlusion.Conclusion:The fistula between pulmonary artery and left atrium is an extremely rare but treatable congenital defect.It should be considered in differential diagnosis of cyanosis in children. 展开更多
关键词 Transcatheter closure FISTULA ventricular septal defect occlude central cyanosis
下载PDF
Building Core Competence of Domestic-Made Mobile Phone
11
作者 Meng Biao (Mobile Phones Division of ZTE Corporation,Shanghai 200233,China) 《ZTE Communications》 2003年第1期52-53,共2页
Chinese domestic mobile phone producerssnatched 30% market share in 2002.Some medias described it as“the firstyear of a reign”which showed the highexpectation from domestic mobile phone in-dustry. The inarguable fac... Chinese domestic mobile phone producerssnatched 30% market share in 2002.Some medias described it as“the firstyear of a reign”which showed the highexpectation from domestic mobile phone in-dustry. The inarguable fact behind the boom isthat most domestic mobile phone manufactur-ers put too more efforts on the brand and mar-ket strategy without any breakthrough in their 展开更多
关键词 Building Core Competence of domestic-made Mobile Phone HAVE as on ZTE of CORE
下载PDF
TRANSCATHETER CLOSURE OF LARGE SECUNDUM ATRIAL SEPTAL DEFECTS WITH AMPLATZER~ SEPTAL OCCLUDER
12
作者 杨震坤 Aubry Pierre +1 位作者 Eric Brochet Jean-Michel Juliard 《Medical Bulletin of Shanghai Jiaotong University》 CAS 2010年第1期40-46,共7页
Objective To evaluate the safety and feasibility of transcatheter closure of large secundum atrial septal defects(ASDs)with Amplatzer~ septal occluder(ASO).Methods A total of 26 patients(age 16 to 67 years,median 43... Objective To evaluate the safety and feasibility of transcatheter closure of large secundum atrial septal defects(ASDs)with Amplatzer~ septal occluder(ASO).Methods A total of 26 patients(age 16 to 67 years,median 43 years;body weight 52 to 102 kg,median 67 kg)with large ASDs underwent an attempted transcatheter closure using ASO.Large ASD was defined as those with a balloon-stretched diameter of ≥30 mm.Another 81 patients with small-to-moderate ASD during same period who underwent closure served as controls.Results In patients with large ASDs,the ASD dimension means were(22.1±3.2)mm(range from 16 to 30 mm)and(23.8±2.6)mm(range from 18 to 31mm)assessed by transesophageal echocardiography(TEE)and transthoracic echocardiography(TTE),respectively.The mean balloon-stretched diameter of the ASD was(31.9±2.1)mm(range from 30 to 37mm).The size of device was(32.0±1.9)mm(range from 30 to 36mm).The transcatheter procedure was successful in all patients(100%).Seventeen deployments were performed using the conventional left atrium approach,and remaining 9 patients required the right upper pulmonary vein approach.Immediately after deployment,TEE revealed that complete closure rate was 73%.Procedure-related complications were recorded in 3 patients(12%),including device embolization in one patient,pericardial effusion in one patient,and large hematoma at puncture site in one patient.During follow-up,the complete closure rate increased to 88% at 24h after procedure and 100% at 6 months.The procedural success rates,immediate TEE results and TTE results at 24h and 6 months after procedure,were not significantly different between patients with large ASDs and those with small-to-moderate ASDs.Conclusion Transcatheter closure of large ASDs using ASO is technical feasible and relatively safe.Proper care selection and specific technique modification such as the right upper pulmonary vein approach is vital for the implantation success. 展开更多
关键词 atrial septal defect transcatheter closure Amplatzer septal occluder
下载PDF
Effectiveness and Safety of Transcatheter Closure of Various Ventricular Septal Defects Using Second-Generation Amplatzer Duct Occluders
13
作者 Jianming Wang Qiguang Wang +3 位作者 Xiaotang Sheng Jingsong Geng Jiawang Xiao Xianyang Zhu 《Congenital Heart Disease》 SCIE 2023年第2期183-195,共13页
Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to ... Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients. 展开更多
关键词 Ventricular septal defects Amplatzer Duct occluder II long-term follow-up transcatheter closure
下载PDF
Isolated Major Aortopulmonary Collateral Artery Causing Heart Failure: Transcatheter Occlusion of Mapcas Using Amplatzer Vascular Plugs and Amplatzer Piccolo Occluders
14
作者 Vakhtang Khelashvili Iuri Fkhkadze +1 位作者 Tengiz Shiryaev Omar Gogia 《World Journal of Cardiovascular Diseases》 2023年第11期701-709,共9页
Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmon... Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmonary blood flow. MAPCAs are often associated with cyanotic congenital heart disease with decreased pulmonary blood flow. Isolated MAPCAs are rare in patients without congenital heart disease with structurally normal hearts. Sometimes, isolated congenital MAPCAs can occur without any lung disease. Isolated MAPCAs represent the occurrence of collaterals in the absence of underlying heart disease, which commonly presents as heart failure, recurrent respiratory tract infection, and pulmonary artery hypertension. We report a rare case of congestive heart failure in a 6-year-old patient with dual arterial supply to an otherwise normal right lung, with a normal bronchial tree, and a structurally normal heart. The patient was successfully managed by the closure of collaterals by Amplatzer vascular plugs II (AVPII) and Amplatzer Piccolo Occluders. 展开更多
关键词 Isolated Major Aortopulmonary Collateral Artery Amplatzer Vascular Plugs Amplatzer Piccolo occluder Mapcas Transcatheter Closure
下载PDF
Clinical Study on Amplatzer Occluder Device to CloseVentricular Septal Defect
15
作者 籍振国 刘刚 刘坤申 《South China Journal of Cardiology》 CAS 2005年第2期109-112,121,共5页
Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 wit... Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 with muscular VSD aged 2.5 -28 years old, were successfully closed with Amplatzer oeeluder device by the pereutaneous guidwire through femoral artery-VSD-femoral vein route under the guidance of fluoroscopy, ventrieulography and transthoracic echocardiography (TIE). The diameters of the VSDs were 2.3-15.7 (6.90±2.76)mm by left ventriculography. Results The success rate of transcatheter closure of VSD with Amplatzer devices was 96%(137/143). Minimal residual amount of shunts were found in one patient, although the shunts was decreased one month after the procedure. There were one patient who had respiratory arrest during the procedure, 7 patients(5%)had conduction disturbance, 3 patients had complete left bundle branch block, 2 patients had complete right bundle branch block, 1 patient had Ⅰ degree atrial-ventricular block and 1 patient had Ⅲ degree atr/al-ventricular block during hospitalization. The diameters of the occluder ranged from 4 to 23 (9.13±3.31)mm and were symmetrical in 122 patients and asymmetrical in 15 patients. Conclusions Transcatheter closure of the perimembranous ventrieular septal defect using Amplatzer VSD occluder device is an efficient method for patients with the perimembranous VSD. The operation is simple with a high success rate and a good effect. 展开更多
关键词 Congenital heart disease Ventricular septal defect Perimembranous Amplatzer occluder
下载PDF
Very large aortic pseudoaneurysm repair using a septal occluder
16
作者 Paulo R.A.Caramori Ricardo Lasevitch +5 位作者 Mauricio L.Suksteris Ricardo M.Pianta Joao B.Petracco Fabiano Ramos Fabio M.Velho Felipe S.Torres 《Discussion of Clinical Cases》 2021年第2期14-17,共4页
A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous interven... A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous intervention with stenting of the graft followed by closure of the pseudoaneurysm using an atrial septal defect occluder was successfully carried out. 展开更多
关键词 Ascending aorta PSEUDOANEURYSM Percutaneous repair Septal occluder
下载PDF
Occludin蛋白调控机制及临床意义的研究进展 被引量:18
17
作者 张宇飞 嵇武 黎介寿 《肠外与肠内营养》 CAS 北大核心 2010年第3期175-178,共4页
Occludin蛋白是紧密连接上的主要蛋白质之一,其功能状态与多种疾病的发生、发展密切相关。Oc-cludin蛋白在疾病中的作用及调控机制已成为研究热点。以下主要就近年来对occludin蛋白的调控和临床意义的进展作一综述。
关键词 occludIN蛋白 紧密连接 信号转导 蛋白调控机制
下载PDF
Duct-Occlud封堵器和Cook可控弹簧栓子治疗动脉导管未闭的对比研究 被引量:3
18
作者 张庆桥 蒋世良 +6 位作者 黄连军 赵世华 徐仲英 凌坚 郑宏 谢若兰 戴汝平 《中国介入心脏病学杂志》 2004年第1期3-5,共3页
目的 对比研究Duct Occlud封堵器和Cook可控弹簧栓子治疗直径≤ 4mm动脉导管未闭 (PDA)的疗效。方法  1996年 4月至 2 0 0 2年 8月 ,4 2例直径 <2mm和 2 9例直径 2~ 4mm的PDA患者施行了Duct Occlud封堵器 (2 5例 )和Cook可控弹簧... 目的 对比研究Duct Occlud封堵器和Cook可控弹簧栓子治疗直径≤ 4mm动脉导管未闭 (PDA)的疗效。方法  1996年 4月至 2 0 0 2年 8月 ,4 2例直径 <2mm和 2 9例直径 2~ 4mm的PDA患者施行了Duct Occlud封堵器 (2 5例 )和Cook可控弹簧栓子 (4 6例 )封堵术。结果  (1)直径 <2mm的PDA行Duct Occlud封堵器和Cook可控弹簧栓子封堵后 10min、2 4h和 12个月残余分流率显著小于直径 2~ 4mm的PDA(分别为 4 8%与 6 2 0 % ,0与 37 9% ,0与 13 8% ;P均 <0 0 5 )。 (2 )Duct Oc clud封堵器治疗直径 2~ 4mm的PDA后 10min ,2 4h ,1和 12个月残余分流率显著高于Cook可控弹簧栓子组 (分别为 94 4 %与 9 1% ,6 1 1%与 0 ,4 4 4 %与 0 ,33 3%与 0 ;P均 <0 0 5 ) ,其中Duct Occlud封堵器脱落至腹主动脉远端 1例 ,向左肺动脉内凸出 4例 ;2例直径 2~ 4mm的PDA患者置入 2枚Cook可控弹簧栓子。结论 Duct Occlud封堵器和Cook可控弹簧栓子均是治疗直径 <2mmPDA的安全有效方法 ;Cook可控弹簧栓子封堵直径 2~ 4mm的PDA近、中期疗效优于Duct Occlud封堵器 ,但部分患者需置入 2枚栓子。 展开更多
关键词 Duct-occlud 封堵器 Cook型 可控弹簧栓子 动脉导管未闭 经导管封堵术 介入治疗
下载PDF
新生大鼠缺氧缺血性脑损伤ZO-1和occludin的动态变化研究 被引量:3
19
作者 孙晔珣 初桂兰 《中国现代医学杂志》 CAS CSCD 北大核心 2010年第21期3210-3213,共4页
目的探讨紧密连接蛋白ZO-1和occludin在缺氧缺血性脑损伤(HIBD)中的变化及意义。方法 36只新生7日龄SD大鼠,随机分为假手术对照组、HIBD3、6、24、48及72 h组,每组大鼠6只建立HIBD模型。观察处死时每只新生大鼠脑组织的大体形态变化,同... 目的探讨紧密连接蛋白ZO-1和occludin在缺氧缺血性脑损伤(HIBD)中的变化及意义。方法 36只新生7日龄SD大鼠,随机分为假手术对照组、HIBD3、6、24、48及72 h组,每组大鼠6只建立HIBD模型。观察处死时每只新生大鼠脑组织的大体形态变化,同时采用Real-time Q-PCR方法测定大鼠脑组织ZO-1 mRNA和occludin mRNA表达。结果①对照组大鼠ZO-1mRNA表达较高。在HIBD 3 h组,其表达开始降低,24 h表达达到最低点,此后逐渐升高,72 h仍维持较低水平。与对照组相比,各组均有统计学意义(P<0.05);对照组大鼠occludin mRNA表达较高。在HIBD 3 h组,其表达开始降低,24 h表达下降到最低点,此后逐渐升高,72 h仍维持在较低水平。与对照组相比各组均有统计学意义(P<0.05);②新生大鼠HIBD后24~48 h脑水肿明显。结论脑缺氧缺血时发生脑水肿,可能与ZO-1和occludin的表达减少有关。 展开更多
关键词 缺氧缺血 新生大鼠 紧密连接蛋白-1 occludIN蛋白
下载PDF
Management of an occluded biliary metallic stent 被引量:6
20
作者 Wiriyaporn Ridtitid Rungsun Rerknimitr 《World Journal of Gastrointestinal Endoscopy》 CAS 2012年第5期157-161,共5页
In patients with a malignant biliary obstruction who require biliary drainage,a self-expandable metallic stent(SEMS) provides longer patency duration than a plastic stent(PS).Nevertheless,a stent occlusion by tumor in... In patients with a malignant biliary obstruction who require biliary drainage,a self-expandable metallic stent(SEMS) provides longer patency duration than a plastic stent(PS).Nevertheless,a stent occlusion by tumor ingrowth,tumor overgrowth and biliary sludge may develop.There are several methods to manage occluded SEMS.Endoscopic management is the preferred treatment,whereas percutaneous intervention is an alternative approach.Endoscopic treatment involves mechanical cleaning with a balloon and a second stent insertion as stent-in-stent with either PS or SEMS.Technical feasibility,patient survival and cost-effectiveness are important factors that determine the method of re-drainage and stent selection. 展开更多
关键词 occluded BILIARY METALLIC STENT Re-drainage COST EFFECTIVENESS
下载PDF
上一页 1 2 64 下一页 到第
使用帮助 返回顶部