期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
New Method of Total Ionizing Dose Compact Modeling in Partially Depleted Silicon-on-Insulator MOSFETs 被引量:4
1
作者 黄建强 何伟伟 +3 位作者 陈静 罗杰馨 吕凯 柴展 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第9期82-85,共4页
On the basis of a detailed discussion of the development of total ionizing dose (TID) effect model, a new commercial-model-independent TID modeling approach for partially depleted silicon-on-insulator metal-oxide- s... On the basis of a detailed discussion of the development of total ionizing dose (TID) effect model, a new commercial-model-independent TID modeling approach for partially depleted silicon-on-insulator metal-oxide- semiconductor field effect transistors is developed. An exponential approximation is proposed to simplify the trap charge calculation. Irradiation experiments with 60Co gamma rays for IO and core devices are performed to validate the simulation results. An excellent agreement of measurement with the simulation results is observed. 展开更多
关键词 of New method of Total Ionizing Dose Compact Modeling in Partially Depleted Silicon-on-Insulator MOSFETs for SOI TID in is IO NMOS on
下载PDF
Development of A Reference Dose for BDE-47,99,and 209 Using Benchmark Dose Methods
2
作者 LI Lu Xi CHEN Li +5 位作者 CAO Dan CHEN Bing Heng ZHAO Yan MENG Xiang Zhou XIE Chang Ming ZHANG Yun Hui 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第9期733-739,共7页
Eleven recently completed toxicological studies were critically reviewed to identify toxicologically significant endpoints and dose-response information. Dose-response data were compiled and entered into the USEPA's ... Eleven recently completed toxicological studies were critically reviewed to identify toxicologically significant endpoints and dose-response information. Dose-response data were compiled and entered into the USEPA's benchmark dose software (BMDS) for calculation of a benchmark dose (BMD) and a benchmark dose low (BMDL). After assessing 91 endpoints across the nine studies, a total of 23 of these endpoints were identified for BMD modeling, and BMDL estimates corresponding to various dose-response models were compiled for these separate endpoints. Thyroid, neurobehavior and reproductive endpoints for BDE-47, -99, -209 were quantitatively evaluated. According to methods and feature of each study, different uncertainty factor (UF) value was decided and subsequently reference doses (RfDs) were proposed. Consistent with USEPA, the lowest BMDLs of 2.10, 81.77, and 1698 I^g/kg were used to develop RfDs for BDE-47, -99, and -209, respectively. RfDs for BDE-99 and BDE-209 were comparable to EPA results, and however, RfD of BDE-47 was much lower than that of EPA, which may result from that reproductive/developmental proves to be more sensitive than neurobehavior for BDE-47 and the principal study uses very-low-dose exposure. 展开更多
关键词 BDE Development of A Reference Dose for BDE-47 99 and 209 Using Benchmark Dose methods
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部