期刊文献+
共找到141篇文章
< 1 2 8 >
每页显示 20 50 100
Comparison between Double Crystals X-ray Diffraction and Micro-Raman Measurement on Composition Determination of High Ge Content Si_(1-x)Ge_(x) Layer Epitaxied on Si Substrate 被引量:1
1
作者 Lei ZHAO Yuhua ZUO Buwen CHENG Jinzhong YU Qiming WANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2006年第5期651-654,共4页
It is important to acquire the composition of Si1-xGex layer, especially that with high Ge content, epitaxied on Si substrate. Two nondestructive examination methods, double crystals X-ray diffraction (DCXRD) and mi... It is important to acquire the composition of Si1-xGex layer, especially that with high Ge content, epitaxied on Si substrate. Two nondestructive examination methods, double crystals X-ray diffraction (DCXRD) and micro-Raman measurement, were introduced comparatively to determine x value in Si1-xGex layer, which show that while the two methods are consistent with each other when x is low, the results obtained from double crystals X-ray diffraction are not credible due to the large strain relaxation occurring in Si1-xGex layers when Ge content is higher than about 20%. Micro-Raman measurement is more appropriate for determining high Ge content than DCXRD. 展开更多
关键词 Si1-xGex Ge content Composition determination double crystals x-ray diffraction (DCXRD) Micro-Raman measurement
下载PDF
Wood Moisture Content Measurement by X-Ray Exposure Method
2
作者 尚德库 《Journal of Forestry Research》 SCIE CAS CSCD 1997年第1期54-58,共5页
Although quite a numer of papers can be found up to now dealing with the subject of the measurement ofwood density by using the X-ray exposure methods, direet scanning or radiographic photography, the following two as... Although quite a numer of papers can be found up to now dealing with the subject of the measurement ofwood density by using the X-ray exposure methods, direet scanning or radiographic photography, the following two aspects,which are very important from both theorctical and engineering application points of view, have not yet been properly handled. One is that the elementary analyses or the experimental measurement on the mass attenuation coefficients were notspecified in regard to spectnun energv distridutions [1]. In this connection, the ambiguities in the specification of the coeffiecients and in turn for thc results among studies arise when only one of the two parameters, namely wave length and applied voltage, of detining the energy spectrum of X-ray is given. The oher is that the relationships between the relative intensity and the sample thickness as well the wood moisture content [2], which are the critical factors for the design and theselection of X-ray apparatus, were not sufficiently examined. In addition, the knowledge of the measurelnent of woodmiosture content by using the direct X-ray scanning method is also almost unavaible now. In the study, the direct X-rayscanning method of measuring wood moisture content was at first investigated theoretically with respect to the relationshipbetween the mass attenuation coefficients of wood (beech, Fagus Sylvatica) and the maximum spectrum energy of X-ray.Secondly, the dependence of the relative intensity on the sample thickness and on the wood moisture content was analysed.The main advantage of the method is on-site nondestructive measuring of wood moisture content in the processes such asdrying, impregnation and unsteady mass diffusion. Specifically for the application in the area of biomechanics, the methodcan also bc used for understanding the water pathway within wood, for example, the water around the knots and the relation between the stress distribution and the local moisture content of wood. 展开更多
关键词 Mass attenuation coefficient Maximum spectrum energy Moisture content Relative intensity Sample thickness x-ray exposure
下载PDF
Analysis of Coronary Angiography Video Interpolation Methods to Reduce X-ray Exposure Frequency Based on Deep Learning
3
作者 Xiao-lei Yin Dong-xue Liang +4 位作者 Lu Wang Jing Qiu Zhi-yun Yang Jian-zeng Dong Zhao-yuan Ma 《Cardiovascular Innovations and Applications》 2021年第3期17-24,共8页
Cardiac coronary angiography is a major technique that assists physicians during interventional heart surgery.Under X-ray irradiation,the physician injects a contrast agent through a catheter and determines the corona... Cardiac coronary angiography is a major technique that assists physicians during interventional heart surgery.Under X-ray irradiation,the physician injects a contrast agent through a catheter and determines the coronary arteries’state in real time.However,to obtain a more accurate state of the coronary arteries,physicians need to increase the fre-quency and intensity of X-ray exposure,which will inevitably increase the potential for harm to both the patient and the surgeon.In the work reported here,we use advanced deep learning algorithms to fi nd a method of frame interpola-tion for coronary angiography videos that reduces the frequency of X-ray exposure by reducing the frame rate of the coronary angiography video,thereby reducing X-ray-induced damage to physicians.We established a new coronary angiography image group dataset containing 95,039 groups of images extracted from 31 videos.Each group includes three consecutive images,which are used to train the video interpolation network model.We apply six popular frame interpolation methods to this dataset to confi rm that the video frame interpolation technology can reduce the video frame rate and reduce exposure of physicians to X-rays. 展开更多
关键词 coronary angiography video interpolation deep learning x-ray exposure frequency
下载PDF
Effect of N-doping-derived solvent adsorption on electrochemical double layer structure and performance of porous carbon
4
作者 Zhe-Fan Wang Cheng Tang +6 位作者 Qian Sun Ya-Lu Han Zhi-Jian Wang Lijing Xie Shou-Chun Zhang Fang-Yuan Su Cheng-Meng Chen 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第5期120-127,I0004,共9页
N-doped porous carbon has been extensively investigated for broad electrochemical applications.The performance is significantly impacted by the electrochemical double layer(EDL),which is material dependent and hard to... N-doped porous carbon has been extensively investigated for broad electrochemical applications.The performance is significantly impacted by the electrochemical double layer(EDL),which is material dependent and hard to characterize.Limited understanding of doping-derived EDL structure hinders insight into the structure-performance relations and the rational design of high-performance materials.Thus,we analyzed the mass and chemical composition variation of EDL within electrochemical operation by electrochemical quartz crystal microbalance,in-situ X-ray photoelectron spectroscopy,and time-offlight secondary ion mass spectrometry.We found that N-doping triggers specifically adsorbed propylene carbonate solvent in the inner Helmholtz plane(IHP),which prevents ion rearrangement and enhances the migration of cations.However,this specific adsorption accelerated solvent decomposition,rendering rapid performance degradation in practical devices.This work reveals that the surface chemistry of electrodes can cause specific adsorption of solvents and change the EDL structure,which complements the classical EDL theory and provide guidance for practical applications. 展开更多
关键词 Carbon materials Electrochemical double layer Electrochemical quartz crystal microbalance In-situ x-ray photoelectron spectroscopy N-DOPING
下载PDF
Transient infiltration tests in pyroclastic soils with double porosity
5
作者 Ciro SEPE Domenico CALCATERRA +6 位作者 Emilia DAMIANO Diego DI MARTIRE Roberto GRECO Lucia PAPPALARDO Massimo RAMONDINI Enza VITALE Giacomo RUSSO 《Journal of Mountain Science》 SCIE CSCD 2023年第11期3327-3342,共16页
Fallout volcanic deposits of SommaVesuvius(Campania,southern Italy),characterized by the presence of layers with contrasting textural and hydraulic properties,are frequently affected by shallow landslides during rainw... Fallout volcanic deposits of SommaVesuvius(Campania,southern Italy),characterized by the presence of layers with contrasting textural and hydraulic properties,are frequently affected by shallow landslides during rainwater infiltration.The soils of the stratigraphic sequence present intraparticle pores,originated by the gases escaped during magma decompression in the volcanic conduit,thus are characterized by double porosity(i.e.,intraparticle and interparticle pores),which is expected to affect their hydraulic behaviour,and to play a key role in rainwater infiltration through layered deposits.To understand the effect of double porosity on the hydraulic behaviour of the involved soils,controlled experiments have been carried out in an infiltration column.The experimental apparatus is provided with newly designed non-invasive Time Domain Reflectometry(TDR)probes,not buried in the investigated soil layers so as to minimize disturbance to the flow,allowing water content measurement during vertical flow processes.Specifically,transient flow experiments are carried out through reconstituted specimens of black scoriae and grey pumices,both loose pyroclastic granular soils from fallout deposits of Somma-Vesuvius,featuring double porosity with different pore size distributions,that were estimated by X-ray tomography and Mercury Intrusion Porosimetry.The experimental results highlight the effects of the double porosity and clearly indicate the different behaviour of the two soils during wetting and drying processes,mainly related to the different dimensions of intraparticle pores. 展开更多
关键词 double porosity soil Non-invasive TDR probes Vesiculated soil particles Pyroclastic soils x-ray tomography Mercury intrusion porosimetry
下载PDF
Identification and comparison of the local physicochemical structures of transition metal-based layered double hydroxides for high performance electrochemical oxygen evolution reactions
6
作者 Min Sung Kim Bipin Lamichhane +5 位作者 Ju-Hyeon Lee Jin-Gyu Bae Jeong Yeon Heo Hyeon Jeong Lee Shyam Kattel Ji Hoon Lee 《Journal of Energy Chemistry》 SCIE EI CSCD 2023年第12期89-97,I0004,共10页
Layered double hydroxides(LDHs) have attracted considerable attention as a cost effective alternative to the precious iridium-and ruthenium-based electrocatalysts for an oxygen evolution reaction(OER),a bottleneck of ... Layered double hydroxides(LDHs) have attracted considerable attention as a cost effective alternative to the precious iridium-and ruthenium-based electrocatalysts for an oxygen evolution reaction(OER),a bottleneck of water electrolysis for sustainable hydrogen production.Despite their excellent OER performance,the structural and electronic properties of LDHs,particularly during the OER process,remain to be poorly understood.In this study,a series of LDH catalysts is investigated through in situ X-ray absorption fine structure analyses and density functional theory(DFT) calculations.Our experimental results reveal that the LDH catalyst with equal amounts of Ni and Fe(NF-LDH) exhibits the highest OER activity and catalytic life span when compared with its counterparts having equal amounts of Ni and Co(NC-LDH)and Ni only(Ni-LDH).The NF-LDH shows a markedly enhanced OER kinetics compared to the NC-LDH and the Ni-LDH,as proven by the lower overpotentials of 180,240,and 310 mV,respectively,and the Tafel slopes of 35.1,43.4,and 62.7 mV dec^(-1),respectively.The DFT calculations demonstrate that the lowest overpotential of the NF-LDH is associated with the active sites located at the edge planes of NF-LDH in contrast to those located at the basal planes of Ni-LDH and NC-LDH.The current study pinpoints the active sites on various LDHs and presents strategies for optimizing the OER performance of the LDH catalysts. 展开更多
关键词 Layered double hydroxides Oxygen evolution reaction In situ x-ray analyses Density functional theory Catalytic active sites
下载PDF
Jahn–Teller Effect, Crystal Structure and High Temperature Raman Spectroscopy Studies of Ba<sub>2-x</sub>Sr<sub>x</sub>CuWO<sub>6</sub>(0 &le;x&le;2) Double Perovskite Oxide.
7
作者 Amine Ezzahi Abdellah Elmchaouri 《Advances in Materials Physics and Chemistry》 2014年第4期61-74,共14页
The following article has been retracted due to the investigation of complaints received against it. The Editorial Board found that there are conflicts of interests among the authors. The scientific community takes a ... The following article has been retracted due to the investigation of complaints received against it. The Editorial Board found that there are conflicts of interests among the authors. The scientific community takes a very strong view on this matter, and the Advances in Materials Physics and Chemistry treats all unethical behaviors seriously. This paper published in Vol. 4 No. 4 61-74, 2014 has been removed from this site. Title: Jahn–Teller Effect, Crystal Structure and High Temperature Raman Spectroscopy Studies of Ba2-xSrxCuWO6 (0 ≤ x≤ 2) Double Perovskite Oxide. Authors: Amine Ezzahi, Abdellah 展开更多
关键词 Jahn–Teller Rietveld x-ray Diffraction double Perovskites BaSrCuWO6.
下载PDF
低频脉冲磁场慢性暴露对健康成年股四头肌收缩力及形态的影响
8
作者 王选强 张文洋 +5 位作者 李阳 孔维签 李伟 王乐 厉中山 白石 《中国组织工程研究》 CAS 北大核心 2025年第8期1634-1642,共9页
背景:目前已有关于低频脉冲磁场对骨骼肌结构形态影响研究发现了骨骼肌质量变化,但对接受慢性暴露后的形态变化未见相关研究。目的:观察低频脉冲磁场慢性暴露对腿部股四头肌最大自主收缩力与形态指标的影响,为使用该技术作为肌肉功能改... 背景:目前已有关于低频脉冲磁场对骨骼肌结构形态影响研究发现了骨骼肌质量变化,但对接受慢性暴露后的形态变化未见相关研究。目的:观察低频脉冲磁场慢性暴露对腿部股四头肌最大自主收缩力与形态指标的影响,为使用该技术作为肌肉功能改善策略提供组织形态变化的参考依据。方法:招募普通健康受试者70名,随机分为接受磁场刺激的试验组与进行假治疗的对照组,每组35名,试验时长共计4周,试验组受试者每隔48 h进行1次15 min的低频脉冲磁刺激干预,对照组进行假治疗,干预间隔与时长与试验组一致,干预4周后观察不同组别受试者股四头肌最大自主收缩力值变化,利用B型超声影像作为评估手段,观察肌肉厚度、肌肉横截面积及羽状角指标的变化。结果与结论:①经过4周的低频脉冲磁场慢性暴露,68名受试者完成试验,试验组受试者股四头肌最大自主收缩力测试值显著增长(P=0.000),提升幅度显著高于对照组(P=0.008);②试验组受试者的肌肉形态3项指标均显著高于试验前测(P=0.000),而对照组肌肉厚度指标呈显著性下降(P=0.020),羽状角无显著性变化,横截面积显著性提升(P=0.000);③组间对比发现,试验组关于肌肉形态的肌肉厚度(P=0.012)、羽状角(P=0.003)及横截面积(P=0.049)3项指标均显著高于对照组;④上述数据证实,健康成年受试者经过4周的低频脉冲磁场慢性暴露,股四头肌的最大自主收缩力显著提升,同时观察到试验组的肌肉厚度、横截面积及羽状角3项肌肉形态指标的显著增长,对使用该技术作为肌肉改善的运动替代与医疗策略提供了肌组织形态改善的支持依据。 展开更多
关键词 低频脉冲磁场 慢性暴露 瞬时感受器电位通道1 TRPC1 骨骼肌形态结构 最大自主收缩力 肌骨超声 肌肉厚度 肌肉横截面积 羽状角 双盲试验
下载PDF
Knowledge of radiation exposure associated with common trauma imaging modalities among orthopaedic surgeons,emergency medicine physicians,and general surgeons in the United States
9
作者 Fady Y.Hijji Andrew D.Schneider +4 位作者 Matthew D.Thomas Joseph G.Lyons Daniel D.Bohl Jennifer L.Jerele Michael J.Prayson 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2023年第4期294-301,共8页
BACKGROUND:Few contemporary studies have assessed physicians’knowledge of radiation exposure associated with common imaging studies,especially in trauma care.The purpose of this study was to assess the knowledge of p... BACKGROUND:Few contemporary studies have assessed physicians’knowledge of radiation exposure associated with common imaging studies,especially in trauma care.The purpose of this study was to assess the knowledge of physicians involved in caring for trauma patients regarding the effective radiation doses of musculoskeletal(MSK)imaging studies routinely utilized in the trauma setting.METHODS:An electronic survey was distributed to United States orthopaedic surgery,general surgery,and emergency medicine(EM)residency programs.Participants were asked to estimate the radiation dose for common imaging modalities of the pelvis,lumbar spine,and lower extremity,in terms of chest X-ray(CXR)equivalents.Physician estimates were compared to the true effective radiation doses.Additionally,participants were asked to report the frequency of discussing radiation risk with patients.RESULTS:A total of 218 physicians completed the survey;102(46.8%)were EM physicians,88(40.4%)wereorthopaedicsurgeons,and28(12.8%)weregeneralsurgeons.Physicians underestimated the effective radiation doses of nearly all imaging modalities,most notably for pelvic computed tomaography(CT)(median 50 CXR estimation vs.162 CXR actual)and lumbar CT(median 50 CXR estimation vs.638 CXR actual).There was no difference between physician specialties regarding estimation accuracy(P=0.133).Physicians who regularly discussed radiation risks with patients more accurately estimated radiation exposure(P=0.007).CONCLUSION:The knowledge among orthopaedic and general surgeons and EM physicians regarding the radiation exposure associated with common MSK trauma imaging is lacking.Further investigation with larger scale studies is warranted,and additional education in this area may improve care. 展开更多
关键词 Radiation dosage Radiation exposure Radiation protection x-ray Emergency department
下载PDF
A Derived Exposure Chart for Computed Radiography in a Negroid Population
10
作者 Thomas Adejoh Odira C. Ewuzie +2 位作者 Joshua K. Ogbonna Stanley O. Nwefuru Nnamdi C. Onuegbu 《Health》 CAS 2016年第10期953-958,共6页
Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiograp... Background: Computed radiography has a wider exposure latitude when compared with film-screen imaging system. Consequently, the risk of dose creep is high. A conscientious effort is there-fore, needed by the radiographer to keep exposure as low as reasonably achievable. Objective: To derive a computed radiography exposure chart for a negroid population using AGFA photostimulable phosphor plates and a GE static X-ray machine. Materials and Method: A static X-ray machine, a digitizer, and photostimulable phosphor plates were used for the X-ray examination. Chest examinations were done at a Focus-Film-Distance (FFD) of 150 - 180 cm while all other examinations were conducted at 90 - 100 cm FFD. The range of exposure factors (kVp, mA and mAs) used by radiog-raphers in the centre was noted and the 90th percentile calculated. Over a three-month period, the patients were examined with the 90th percentile of tube potential (kVp) while keeping other factors constant. The kVp was gradually decreased and halted if radiologists and radiographers uncon-nected with the work expressed misgivings about the quality of the image. A similar procedure was adopted for the tube current (mA). The threshold adopted as low as reasonably achievable was the factor preceding the point of observation by other personnel. Metrics for central tendency from the statistical packages for social sciences, version 17.0 was used to analyze the data. Results: 335 subjects of both gender aged 0 - 92 years were examined by the researchers. Adult exposure factors used by the radiographers (and those derived by the researchers) had a range of 45 - 130 kVp (62 - 94 kVp), 63 - 320 mA (100 - 250 mA) and 4.0 - 25.0 mAs (5.0 - 20.0 mAs) respectively. Pediatric chest (and researchers-derived) factors were 50 - 75 kVp (52 - 65 kVp), 50 - 250 mA (100 - 220 mA) and 3.20 - 10.0 mAs (3.2 - 6.5 mAs) respectively. Conclusion: Upper threshold of adult (and paediatric) exposure factors in computed radiography with comparable equipment and accessories should not exceed 94 kVp (65 kVp), 250 mA (220 mA) and 20.0 mAs (6.5 mAs) respectively. The derived exposure chart is also adequate to address motion unsharpness in chest examinations. 展开更多
关键词 Computed Radiography exposurE RADIOGRAPHER kVp Tube Current x-ray
下载PDF
BODY SURFACE EXPOSURE DISTRIBUTION OF EXAMINEES RECEIVED UPPER G.I.T.X-RAY EXAMINATION
11
作者 冯定华 程祺钧 《Nuclear Science and Techniques》 SCIE CAS CSCD 1995年第1期51-53,共3页
A special cloth for keeping LiF(Mg,Cu,P)TL dosimetry elements is worn by examinees. The exposures of 128 examinees .received upper G.I.T (gastro-intestinal tram) X-ray examination are measured. The reference point of ... A special cloth for keeping LiF(Mg,Cu,P)TL dosimetry elements is worn by examinees. The exposures of 128 examinees .received upper G.I.T (gastro-intestinal tram) X-ray examination are measured. The reference point of the maximum body surface exposure given is at the middle of stomach. The average of this point is (4.97±1.94) × 10-4C.kg-1 person-1 examination-1 and (1.33±0.28)×10-4C.kg-1.min-1. 展开更多
关键词 Upper G.I.T. x-ray examination Body surface exposure Radiation dose distribution Reference point of maximum surface exposure
下载PDF
The Transcriptional Response of Arabidopsis thaliana L. Genes AtKu70, AtRAD51 and AtRadl to X-Ray Radiation
12
作者 Sergey Litvinov Namik Rashydov 《Journal of Agricultural Science and Technology(A)》 2017年第1期52-60,共9页
The study of influence of the fractionated and acute ionizing radiation on plants revealed that it is able to induce genomic instability. The hypothesis that transcription rate of several evolutionary conserved DNA re... The study of influence of the fractionated and acute ionizing radiation on plants revealed that it is able to induce genomic instability. The hypothesis that transcription rate of several evolutionary conserved DNA repair genes AtKu 70, AtRAD51 and AtRadl, which keeps genome stability in cells of model plant Arabidopsis thaliana, changes differently depending on dose and mode of ionizing radiation exposure had been tested. Gel electrophoresis-based reverse transcription polymerase chain reaction (RT-PCR) method was used for quantifying mRNA transcription levels. The data demonstrated that mode and dose of irradiation affect transcription rate of the genes AtKuTO, AtRAD51 and AtRadI. The fractionated and acute X-ray irradiation may result in adaptive response through the induction of key DNA double-strand break (DSB) repair genes AtKu70 and AtRAD51, as well as in genome instability through transcriptional activation of error-prone AtRadl-mediated DNA DSB repair combined with decreased expression of AtRAD51. In plants at doses within the range of 3-9 Gy, an adaptive influence is prevailed, but at doses of 12-21 Gy an error-prone repair of double-strand DNA damage is activated. Fractionation of dose has a significant effect on the transcription of the genes AtKuTO, AtRAD51 and AtRadl only at doses of 15 Gy and 21 Gy. Acute dose of 15 Gy activates error-prone AtRadl-mediated DSB repair and repressed both AtRAD51-dependent and AtKu70-dependent repair pathways, while fractionated irradiation at the same total dose induces more accurate homologous recombination and canonical non-homologous end joining of the DNA strands. In case of A. thaliana exposed to X-rays at dose 21 Gy, the situation is going reversed because of strong induction of the all three genome caretaker genes in leaves of acutely irradiated plants in contrast to the plants under fractionated exposure. 展开更多
关键词 x-ray exposure DNA repair gene expression transcription rate genome instability.
下载PDF
Role of contrast-enhanced serial/spot abdominal X-rays in perioperative follow-up of patients undergoing abdominal surgery:An observational clinical study
13
作者 Osman Nuri Dilek Arif Atay +2 位作者 Orgun Gunes Furkan Karahan Şebnem Karasu 《World Journal of Radiology》 2023年第6期191-200,共10页
BACKGROUND Many imaging methods such as ultrasonography,computed tomography(CT),magnetic resonance imaging,and endoscopy are used to identify the problems or complications that occur in the perioperative period and to... BACKGROUND Many imaging methods such as ultrasonography,computed tomography(CT),magnetic resonance imaging,and endoscopy are used to identify the problems or complications that occur in the perioperative period and to determine the appropriate therapeutic approach.Specialists at surgical clinics and intensive care units sometimes need diagnostic procedures that can give quick results or reveal unexpected results.In particular,rapid on-site evaluation of patients followed under intensive care conditions has several advantages.AIM To determine the problems developing in patients in the perioperative period by contrast-enhanced abdominal X-ray(CE-AXR),revealing their current status or defining the effectiveness of CE-AXR.METHODS The files of the patients who underwent hepatopancreatobiliary or upper gastrointestinal surgery,whose CE-AXR film was taken,were reviewed retrospectively.Abdominal X-ray radiographs taken after ingestion of a watersoluble contrast agent(iohexol,300 mg,50 cc vial)and its application in a drain,nasogastric tube,or stent were evaluated.The contribution of the data obtained in patients who underwent CE-AXR to the diagnosis,follow-up,and treatment processes and the effectiveness of the application were investigated.RESULTS CE-AXR was applied to 131 patients in our clinic,most of whom underwent hepatopancreatobiliary or upper gastrointestinal surgery.It was determined that the data obtained from CE-AXR films taken in 98(74.8%)of the patients contributed to the diagnosis,treatment,and follow-up expectations and positively affected the clinical processes.CONCLUSION CE-AXR is a simple procedure that can be applied anywhere,especially in intensive care patients and at bedside,with a portable X-ray device.The simplicity of the procedure,less radiation exposure for the patients,less time wastage,reduction in the CT and endoscopy procedure burden and costs,quick results,rapid assessment of the situation,and enabling the monitoring of processes with repetitive procedures are important advantages.X-rays taken will be useful in terms of being a reference value during the follow-up period of the patient and determining the situation in medicolegal processes. 展开更多
关键词 Abdominal x-rays Contrast medium Diagnosis COMPLICATION Leakage Radiation exposure
下载PDF
Laser Produced Plasma X-Ray Sources for Nanoscale Resolution Contact Microscopy: A Candidate in Cancerous Stem Cells Imaging
14
作者 Yas Al-Hadeethi A. Al-Mujtabi Fahd M. Al-Marzouki 《Advances in Molecular Imaging》 2017年第4期67-77,共11页
Plasma X-ray sources for biological microscopy have been produced by focusing single shots from Nd:glass laser onto carbon rod targets at irradiances between 1 × 1013 W&sdot;cm&minus;2 and 3 × 1013 W... Plasma X-ray sources for biological microscopy have been produced by focusing single shots from Nd:glass laser onto carbon rod targets at irradiances between 1 × 1013 W&sdot;cm&minus;2 and 3 × 1013 W&sdot;cm&minus;2 to expose test objects. The optimum parameters needed for obtaining high accurate information on the samples under test namely: the minimum energies and irradiances at a range of angles between the incoming laser beam and the normal to the resist, the depth of exposure of the photoresist as a function of incident laser energy (and irradiance) were concluded in this work. 展开更多
关键词 LASER PLASMAS CONTACT MICROSCOPY LASER Ablation Water Window x-rays PMMA PHOTORESIST Mass Ablation Rate exposure Depth
下载PDF
Wide dynamic range CMOS image sensor with in-pixel double-exposure and synthesis
15
作者 李斌桥 孙忠岩 徐江涛 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2010年第5期73-77,共5页
A wide-dynamic-range CMOS image sensor(CIS) based on synthesis of a long-time and a short-time exposure signal in the floating diffusion(FD) of a five-transistor active pixel is proposed.With optimized pixel opera... A wide-dynamic-range CMOS image sensor(CIS) based on synthesis of a long-time and a short-time exposure signal in the floating diffusion(FD) of a five-transistor active pixel is proposed.With optimized pixel operation,the response curve is compressed and a wide dynamic range image is obtained.A prototype wide-dynamic-range CMOS image sensor was developed with a 0.18μm CIS process.With the double exposure time 2.4 ms and 70 ns,the dynamic range of the proposed sensor is 80 dB with 30 frames per second(fps).The proposed CMOS image sensor meets the demands of applications in security surveillance systems. 展开更多
关键词 CMOS image sensor double exposure dynamic range five-transistor active pixel
原文传递
Double junction photodiode for X-ray CMOS sensor IC
16
作者 许超群 孙颖 +1 位作者 韩雁 朱大中 《Journal of Semiconductors》 EI CAS CSCD 2014年第7期84-89,共6页
A CMOS compatible P+/Nwell/Psub double junction photodiode pixel was proposed, which can effi- ciently detect fluorescence from CsI(T1) scintillation in an X-ray sensor. Photoelectric and spectral responses of P+/... A CMOS compatible P+/Nwell/Psub double junction photodiode pixel was proposed, which can effi- ciently detect fluorescence from CsI(T1) scintillation in an X-ray sensor. Photoelectric and spectral responses of P+/Nwell, NweE1/Psub and P+/Nwell/Psub photodiodes were analyzed and modeled. Simulation results show P+/Nweu/Psub photodiode has larger photocurrent than P+/Nwetl photodiode and Nweu/Psub photodiode, and its spectral response is more in accordance with CsI(T1) fluorescence spectrum. Improved P+/Nweu/Psub photodiode detecting CsI(T1) fluorescence was designed in CSMC 0.5 #m CMOS process, CTIA (capacitive transimpedance amplifier) architecture was used to readout photocurrent signal. CMOS X-ray sensor IC prototype contains 8 × 8 pixel array and pixel pitch is 100 × 100 μm2. Testing results show the dark current of the improved P+/Nwell/Psub photodiode (6.5 pA) is less than that of P+/Nwell and P+/Nwell/Psub photodiodes (13 pA and 11 pA respectively). The sen- sitivity of P+/Nwell/Psub photodiode is about 20 pA/lux under white LED. The spectrum response of P+/Nwell/Psub photodiode ranges from 400 nm to 800 nm with a peak at 532 nm, which is in accordance with the fluorescence spectrum of Csl(T1) in an indirect X-ray sensor. Preliminary testing results show the sensitivity of X-ray sensor IC under Cu target X-ray is about 0.21 V.m^2/W or 5097e-/pixel @ 8.05 keV considering the pixel size, integration time and average energy of X-ray photons. 展开更多
关键词 double junction photodiode indirect x-ray sensor CMOS x-ray sensor IC fluorescence detection
原文传递
用全息二次曝光法分析岩石侧向受压形变规律 被引量:5
17
作者 谢锦平 刘冬梅 +2 位作者 黄文勇 董太源 龚永胜 《激光杂志》 CAS CSCD 北大核心 2002年第1期61-62,共2页
本文阐述了岩石侧向受压情况下二次曝光全息干涉条纹的形成原理 ,分析了干涉条纹分布与岩石形变的关系 ,指出当出现密集的纵向干涉条纹时 。
关键词 二次曝光法 干涉条纹 光程差 岩石侧向受压形变规律 全息光学
下载PDF
可分离双参考光两次曝光全息法测机械变形方向 被引量:3
18
作者 李冠成 于艳春 +2 位作者 冯颖 刘小廷 蔡静 《机械工程学报》 EI CAS CSCD 北大核心 2005年第10期235-238,共4页
提出用可分离双参考光两次曝光全息测量物体变形方向的方法,设计的光络系统用两个平面反射镜将一束扩展激光束分成两束参考光和一束物光,藉此记录物体变形下的可分离双参考光两次曝光全息干涉图。这种干涉图含有物体变形的数值和方向的... 提出用可分离双参考光两次曝光全息测量物体变形方向的方法,设计的光络系统用两个平面反射镜将一束扩展激光束分成两束参考光和一束物光,藉此记录物体变形下的可分离双参考光两次曝光全息干涉图。这种干涉图含有物体变形的数值和方向的两种信息,从理论上对此作了分析,叙述了测量物体变形方向的方法,给出了试验结果。 展开更多
关键词 可分离双参考光两次曝光全息法 机械变形方向 测量
下载PDF
复杂旋转回流PIV速度整场实验研究 被引量:9
19
作者 刘应征 陈汉平 《水动力学研究与进展(A辑)》 CSCD 北大核心 2003年第5期601-606,共6页
 复杂旋转回流流动的实验测量研究中,最受关注的是子午面上的速度分布,流动的复杂性对实验测量提出了较高要求,如测点数目多,对流场干扰限制严等。本文从PIV(粒子图象速度场测量)速度场测量技术的工作原理出发,分析了复杂旋转流动子午...  复杂旋转回流流动的实验测量研究中,最受关注的是子午面上的速度分布,流动的复杂性对实验测量提出了较高要求,如测点数目多,对流场干扰限制严等。本文从PIV(粒子图象速度场测量)速度场测量技术的工作原理出发,分析了复杂旋转流动子午面上速度场测量中的双曝光时间间隔,示踪粒子的选取问题,得到了封闭圆柱空腔内旋转流动子午面上速度分布PIV实验测量速度场。实验测量结果可以清楚地观测到随着雷诺数的逐步增加,旋转流动流态的变化以及旋涡破裂现象的出现、发展以及消失的过程。 展开更多
关键词 复杂旋转回流 PIV 速度整场 实验研究 流体力学 流动复杂性 旋涡流动
下载PDF
光纤布拉格光栅反射谱旁瓣的抑制 被引量:8
20
作者 刘伟平 杜戈 +4 位作者 黄君凯 钟雨乐 易清明 廖常俊 刘颂豪 《激光与红外》 CAS CSCD 北大核心 2001年第3期180-183,共4页
计算分析了光纤布拉格 (Bragg)光栅中折射率变化分布 ,折射率变化直流分量对反射旁瓣 (Sidelobes)的影响 ;采用二次曝光技术 ,用高斯光束和均匀相位模板刻制出反射旁瓣受到有效抑制的光纤布拉格光栅 。
关键词 光纤布拉格光栅 反射旁瓣抑制 反射谱
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部