期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Quantum fluctuations of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling 被引量:12
1
作者 徐兴磊 李洪奇 王继锁 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2462-2470,共9页
Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is propo... Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is proposed. The quantum fluctuations of charge and current of each loop in a squeezed vacuum state are studied in the thermal excitation case. It is shown that the fluctuations not only depend on circuit inherent parameters, but also rely on excitation quantum number and squeezing parameter. Moreover, due to the finite environmental temperature and damped resistance, the fluctuations increase with the temperature rising, and decay with time. 展开更多
关键词 mesoscopic double resonance RLC circuit linear transformation thermal excitation state quantum fluctuation
下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
2
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
下载PDF
STRONG EMBEDDINGS OF PLANAR GRAPHS ON HIGHER SURFACES
3
作者 刘同印 刘彦佩 《Acta Mathematica Scientia》 SCIE CSCD 2002年第4期542-548,共7页
In this paper, the authors discuss the upper bound for the genus of strong embeddings for 3-connected planar graphs on higher surfaces. It is shown that the problem of determining the upper bound for the strong embedd... In this paper, the authors discuss the upper bound for the genus of strong embeddings for 3-connected planar graphs on higher surfaces. It is shown that the problem of determining the upper bound for the strong embedding of 3-connected planar near-triangulations on higher non-orientable surfaces is NP-hard. As a corollary, a theorem of Richter, Seymour and Siran about the strong embedding of 3-connected planar graphs is generalized to orientable surface. 展开更多
关键词 surface NP-HARD circuit double cover strong embedding
下载PDF
Transverse wakefield calculated by the double circuit model
4
作者 杨雄斌 侯汨 《Chinese Physics C》 SCIE CAS CSCD 2015年第3期53-57,共5页
X-band accelerators for multi-bunches are a new way to produce high luminosity and energy efficiency bunches. The smaller the size and the more bunches, the more severe is the wakefield in the X-band accelerators, unl... X-band accelerators for multi-bunches are a new way to produce high luminosity and energy efficiency bunches. The smaller the size and the more bunches, the more severe is the wakefield in the X-band accelerators, unless some means of strongly suppressing the transverse wakefield is adopted in the design of the accelerating structure. Here, the derivation of the wakefield function of the double circuit model and its application to the designed accelerator structure have been demonstrated. 展开更多
关键词 transverse wakefield X-band accelerators multi-bunches double circuit model wakefield calculation
原文传递
上一页 1 下一页 到第