期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Parameter Design of Current Double Closed Loop for T-Type Three-Level Grid-Connected Inverter
1
作者 Tiankui Sun Mingming Shi +3 位作者 Xiaolong Xiao Ping He Yu Ji Zhiyuan Yuan 《Energy Engineering》 EI 2023年第7期1621-1636,共16页
To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control a... To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control and the failure to eliminate the influence of the LCL filter on the grid-connected current by using current PI control alone,a current double closed loop PI current tracking control is proposed.Through the theoretical analysis of the grid-connected inverter control principle,the grid-connected inverter control model is designed,and the transfer functionmodel of each control link is deduced,and the current loop PI regulator is designed at last.The simulation results show that the control strategy is feasible. 展开更多
关键词 T-type inverter active damping current double closed loop
下载PDF
Starting Control of Free Piston Stirling Linear Generator System Based on FOC
2
作者 Qiaoling Yang Kechun Zhang +2 位作者 Shenghui Guo Boliang Song Xiaoyu Zhang 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第2期195-200,共6页
Aiming at the problem of poor system dynamic performance caused by low parameter matching in the coordinated control of Stirling engine and linear generator in the starting stage control of free piston Stirling linear... Aiming at the problem of poor system dynamic performance caused by low parameter matching in the coordinated control of Stirling engine and linear generator in the starting stage control of free piston Stirling linear generator system,a joint control method of free piston Stirling permanent magnet synchronous linear generator system based on field orientation control is proposed,based on the theoretical derivation of the mathematical model of the system and the principle of controller parameters setting,the simulation experiments of the system starting stage under several Stirling engine working conditions are carried out under simulation.The experimental results show that the stability and rapidity of the system are improved,and the dynamic response speed of generator parameters under different working conditions is accelerated,what fully verifies the correctness and effectiveness of the method.It provides an effective way to improve the control performance of the system and stabilize the power generation operation. 展开更多
关键词 Parameter setting Field orientation control double closed loop Permanent magnet synchronous linear generator
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部