Energy Saving Model and Calculation Example of Three Cooling Schemes for Data Center in Hot Summer and Cold Winter Area
1
作者 Feihu Chen Xinli Zhou Shuguang Liao 《Journal of Power and Energy Engineering》 2021年第12期1-20,共20页
In order to achieve the goal of “carbon peak” in 2030 and “carbon neutralization” in 2060, the task of energy conservation has risen to the national strategic level, and its work is urgent. It focuses on energy sa... In order to achieve the goal of “carbon peak” in 2030 and “carbon neutralization” in 2060, the task of energy conservation has risen to the national strategic level, and its work is urgent. It focuses on energy saving and energy consumption in data center, 5G network and other fields. The gravity heat pipe double cycle air conditioning is a kind of room air conditioning which uses natural cooling source with high efficiency. According to the outdoor meteorological parameters of ten typical cities in China, the calculation model of unit hybrid refrigeration mode is established by using integral method. A simplified algorithm for statistical summation is proposed. Then it compares with the same type of refrigerant pump air conditioner, water-cooled chiller and natural cooling plate. The results show that the annual operation time of gravity heat pipe double cycle air conditioner is 50.8% longer than that of refrigerant pump air conditioner. Then the calculation model is verified by the annual actual operation data of a data center in Changsha. The results show that the double cycle air conditioner with gravity heat pipe can save about 34% energy compared with the chiller. The accuracy of the calculation model is 17.5%, which meets the engineering accuracy requirements. The application of gravity heat pipe double cycle air conditioning in hot summer and cold winter area is a scheme worthy of popularization and application. 展开更多
关键词 Gravity Heat Pipe double cycle Refrigerant Pump Natural Cooling Inte-gral Method Simplified Algorithm for Statistical Summation Energy Sav-ing Rate
下载PDF
Double Ramification Cycles with Orbifold Targets
2
作者 Bo Hui CHEN Cheng Yong DU Rui WANG 《Acta Mathematica Sinica,English Series》 SCIE CSCD 2022年第8期1333-1376,共44页
In this paper,we consider double ramification cycles with orbifold targets.An explicit formula for double ramification cycles with orbifold targets,which is parallel to and generalizes the one known for the smooth cas... In this paper,we consider double ramification cycles with orbifold targets.An explicit formula for double ramification cycles with orbifold targets,which is parallel to and generalizes the one known for the smooth case,is provided.Some applications for orbifold Gromov–Witten theory are also included. 展开更多
关键词 Root of orbifold line bundles polynomiality double ramification cycle absolute/relative orbifold Gromov–Witten theory
原文传递
Energy-Saving Optimization Study on 700℃ Double Reheat Advanced Ultra-Supercritical Coal-Fired Power Generation System
3
作者 WANG Jing DUAN Liqiang +3 位作者 YANG Jinfu YANG Ming JING Yutian TIAN Liguo 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第1期30-43,共14页
700°C double reheat advanced ultra-supercritical power generation technology is one of the most important development directions for the efficient and clean utilization of coal.To solve the great exergy loss prob... 700°C double reheat advanced ultra-supercritical power generation technology is one of the most important development directions for the efficient and clean utilization of coal.To solve the great exergy loss problem caused by the high superheat degrees of regenerative steam extractions in 700°C double reheat advanced ultra-supercritical power generation system,two optimization systems are proposed in this paper.System 1 is integrated with the back pressure extraction steam turbine,and system 2 is simultaneously integrated with both the outside steam cooler and back pressure extraction steam turbine.The system performance models are built by the Ebsilon Professional software.The performances of optimized systems are analyzed by the unit consumption method.The off-design performances of optimization systems are analyzed.The results show that:the standard power generation coal consumption rates of optimization systems 1 and 2 are decreased by 1.88 g·(kW·h)^(–1),2.97 g·(kW·h)^(–1)compared with that of the 700°C reference system;the average superheat degrees of regenerative steam extractions of optimized systems 1 and 2 are decreased by 122.2°C,140.7°C(100%turbine heat acceptance condition),respectively.The comparison results also show that the performance of the optimized system 2 is better than those of the optimized system 1 and the 700°C reference system.The power generation standard coal consumption rate and the power generation efficiency of the optimized system 2 are about 232.08 g·(kW·h)^(–1)and 52.96%(100%turbine heat acceptance condition),respectively. 展开更多
关键词 700℃ advanced ultra-supercritical(A-USC) double reheat cycle extraction steam superheat degree unit consumption method system optimization
原文传递
Numerical analysis for the matching of the core driven compression system in a double bypass engine 被引量:1
4
作者 ZHANG Xin LIU Bao-jie 《航空动力学报》 EI CAS CSCD 北大核心 2011年第5期1066-1076,共11页
The numerical analysis for the matching of the core driven compression system in a double bypass variable cycle engine was presented in this paper.The system consists of a one-stage-core driven fan stage(CDFS),an inne... The numerical analysis for the matching of the core driven compression system in a double bypass variable cycle engine was presented in this paper.The system consists of a one-stage-core driven fan stage(CDFS),an inner bypass duct and a five-stage high pressure compressor(HPC),providing two basic operating modes: the single bypass mode and the double bypass mode.Variable vanes are necessary to realize the mode switch of the system.The correct matching in the double bypass mode requires a proper combination of the mass flow,total pressure ratio and blade speed.The work capacity of the system decreases in the double bypass mode and the pressure ratio tends to decrease more for the CDFS and the front stages of the HPC.The overall system efficiency is higher in the double bypass mode.The radial distributions of aerodynamic parameters are similar in different modes.The notable redistribution of mass flow downstream the CDFS in the single bypass mode leads to strong radial flows and additional mixing losses.The absolute flow angles into the inner bypass increase for the inner span and decrease for the outer span when the system is switched from the single bypass mode to the double bypass mode. 展开更多
关键词 numerical analysis aerodynamic double bypass variable cycle engine core driven compression system core driven fan stage operating mode
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部