Research on static characteristic of double redundance double nozzle flapper valve based on AMESim
1
作者 孙亚南 LIANG Qiuhui +2 位作者 WANG Wentao YANG Guang ZHANG Wei 《High Technology Letters》 EI CAS 2024年第2期164-169,共6页
The feedback spring rod of the armature assembly is cancelled in the double redundance double nozzle flapper valve(DRDNFV),and the difficulty of valve core displacement control is increased.Therefore,this paper intend... The feedback spring rod of the armature assembly is cancelled in the double redundance double nozzle flapper valve(DRDNFV),and the difficulty of valve core displacement control is increased.Therefore,this paper intends to study the static characteristic of DRDNFV through the AMESet and AMESim simulation.It is explored under the circumstance of the fixed orifices being clogged and experimentally verified on the test bench.The results show that the pressure gain increases and the flow gain decreases with the increasing clogged degree of the fixed orifices on both sides.The zero bias increases synchronously with the increasing clogged degree of the unilateral fixed orifice.The experimental results are basically consistent with the theoretical curves and the theoretical correctness of the simulation model is effectively verified.The results can provide the theoretical reference for design,debugging,maintenance and fault diagnosis of DRDNFV. 展开更多
关键词 double redundance double nozzle flapper valve(DRDNFV) AMESet torquemotor armature assembly fault diagnosis
下载PDF
Numerical Simulation and Experimental Study of Heat-fluid-solid Coupling of Double Flapper-nozzle Servo Valve 被引量:18
2
作者 ZHAO Jianhua ZHOU Songlin +1 位作者 LU Xianghui GAO Dianrong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第5期1030-1038,共9页
The double flapper-nozzle servo valve is widely used to launch and guide the equipment. Due to the large instantaneous flow rate of servo valve working under specific operating conditions, the temperature of servo val... The double flapper-nozzle servo valve is widely used to launch and guide the equipment. Due to the large instantaneous flow rate of servo valve working under specific operating conditions, the temperature of servo valve would reach 120℃ and the valve core and valve sleeve deform in a short amount of time. So the control precision of servo valve significantly decreases and the clamping stagnation phenomenon of valve core appears. In order to solve the problem of degraded control accuracy and clamping stagnation of servo valve under large temperature difference circumstance, the numerical simulation of heat-fluid-solid coupling by using finite element method is done. The simulation result shows that zero position leakage of servo valve is basically impacted by oil temperature and change of fit clearance. The clamping stagnation is caused by warpage-deformation and fit clearance reduction of the valve core and valve sleeve. The distribution roles of the temperature and thermal-deformation of shell, valve core and valve sleeve and the pressure, velocity and temperature field of flow channel are also analyzed. Zero position leakage and electromagnet's current when valve core moves in full-stroke are tested using Electro-hydraulic Servo-valve Characteristic Test-bed of an aerospace sciences and technology corporation. The experimental results show that the change law of experimental current at different oil temperatures is roughly identical to simulation current. The current curve of the electromagnet is smooth when oil temperature is below 80℃, but the amplitude of current significantly increases and the hairy appears when oil temperature is above 80℃. The current becomes smooth again after the warped valve core and valve sleeve are reground. It indicates that clamping stagnation is caused by warpage-deformation and fit clearance reduction of valve core and valve sleeve. This paper simulates and tests the heat-fluid-solid coupling of double flapper-nozzle servo valve, and the obtained results provide the reference value for the design of double flapper-nozzle force feedback servo valve. 展开更多
关键词 double flapper-nozzle servo valve heat-fluid-solid coupling numerical simulation warpage-deformation clamping stagnation zero position leakage
下载PDF
Research on valve core’s clamping stagnation of double flapper-nozzle servo valve 被引量:1
3
作者 Zhao Jianhua Zhang Bin +3 位作者 Chen Tao Wang Qiang Zhou Songlin Gao Dianrong 《High Technology Letters》 EI CAS 2019年第1期65-73,共9页
Due to great changing of instantaneous temperature of hydraulic oil of double flapper-nozzle servo valve, thermal deformation between valve core and valve sleeve may result in catching phenomenon of valve core, and th... Due to great changing of instantaneous temperature of hydraulic oil of double flapper-nozzle servo valve, thermal deformation between valve core and valve sleeve may result in catching phenomenon of valve core, and then the reliability of servo valve could be affected seriously. The work focuses on a particular model of double flapper-nozzle servo valve and establishes three dimension couple models of liquid-solid-thermal under extreme operating condition. The transmission route and dissipative mechanism of heat is revealed and thermal deformation behavior of valve core and valve sleeve is researched. A change law of the key fit clearance under the effect of thermal expansion and warp deformation is explored, the source of catching phenomenon of valve core is identified, and then preventive measure and improvement can be proposed. In order to verify the correctness of theoretical analysis, the moving smoothness of deformed valve core and reground valve core under the circumstance of high-temperature hydraulic oil on electrohydraulic servo valve static characteristics test table is compared and tested. The results show that as oil temperature rises, relative deformations between valve core and valve sleeve in different direction at a same cross-section are not equal, and then the key fit clearance is less than the initial value. Relative deformations in the same direction at different axial position are not equal, the deformations of middle and two ends are maximum and minimum values respectively, and then warp deformation of valve core occurs. When oil temperature is higher, the relative deformations between valve core and valve sleeve is larger, the moving smoothness of valve core gets worse, and the catching phenomenon of valve core occurs. Axial deformation of valve sleeve and valve core at different axial position is different, and the opening coefficient and stability of servo valve could be affected, especially the operation circumstance of small opening. The study can provide some guidance for designing double nozzle flapper servo valves. 展开更多
关键词 double flapper-nozzle servo valve flow-solid-thermal coupling numerical simulation catching phenomenon thermal deformation mechanism smooth movement
下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Congenital Double Orifice Mitral Valve
4
作者 吕清 卢晓芳 +7 位作者 谢明星 王新房 王静 杨亚利 袁莉 贺林 刘夏天 付曼丽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第5期625-628,共4页
The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiograp... The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV. 展开更多
关键词 double orifice mitral valve echocardiography real-time three-dimensional