Application of Stand-off Double-Pulse Laser-Induced Breakdown Spectroscopy in Elemental Analysis of Magnesium Alloy 被引量:2
1
作者 齐立峰 孙兰香 +3 位作者 辛勇 丛智博 李洋 于海斌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期676-681,共6页
In this study, a stand-off and collinear double pulse laser-induced breakdown spectroscopy (DP LIBS) system was designed, and the magnesium alloy samples at a distance of 2.5 m away from the LIBS system were measure... In this study, a stand-off and collinear double pulse laser-induced breakdown spectroscopy (DP LIBS) system was designed, and the magnesium alloy samples at a distance of 2.5 m away from the LIBS system were measured. The effect of inter-pulse delay on spectra was studied, and the signal enhancement was observed compared to the single pulse LIBS (SP LIBS). The morphology of the ablated crater on the sample indicated a higher efficiency of surface pretreatment in DP LIBS. The calibration curves of Ytterbium (Y) and Zirconium (Zr) were investigated. The square of the correlation coefficient of the calibration curve of element Y reached up to 0.9998. 展开更多
关键词 laser-induced breakdown spectroscopy stand-off double-pulse magnesiumalloy
下载PDF
Heavy Metal Detection in Soils by Laser Induced Breakdown Spectroscopy Using Hemispherical Spatial Confinement 被引量:6
2
作者 孟德硕 赵南京 +5 位作者 马明俊 王寅 胡丽 余洋 方丽 刘文清 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期632-637,共6页
Spatial confinement has great potential for Laser Induced Breakdown Spectroscopy (LIBS) instruments after it has been proven that it has the ability to enhance the LIBS signal strength and repeatability. In order to... Spatial confinement has great potential for Laser Induced Breakdown Spectroscopy (LIBS) instruments after it has been proven that it has the ability to enhance the LIBS signal strength and repeatability. In order to achieve in-situ measurement of heavy metals in farmland soils by LIBS, a hemispherical spatial confinement device is designed and used to collect plasma spectra, in which the optical fibers directly collect the breakdown spectroscopy of the soil samples. This device could effectively increase the stability of the spectrum intensity of soil. It also has other advantages, such as ease of installation, and its small and compact size. The relationship between the spectrum intensity and the laser pulse energy is studied for this device. It is found that the breakdown threshold is 160 cm-2, and when the laser fluence increases to 250 J/cm2, the spectrum intensity reaches its maximum. Four different kinds of laser pulse energy were set up and in each case the limits of detection of Cd, Cu, Ni, Pb and Zn were calculated. The results show that when the laser pulse fluence was 2.12 GW/cm2, we obtained the smallest limits of detection of these heavy metals, which are all under 10 mg/kg. This device can satisfy the needs of heavy metal in-situ detection, and in the next step it will be integrated into a portable LIBS instrument. 展开更多
关键词 laser induced breakdown spectroscopy hemispherical spatial confinement laser fiuence limit of detection
下载PDF
Improvement of quantitative analysis of molybdenum element using PLS-based approaches for laser-induced breakdown spectroscopy in various pressure environments 被引量:3
3
作者 Jiamin LIU Ding WU +4 位作者 Cailong FU Ran HAI Xiao YU Liying SUN Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期140-147,共8页
An experimental setup has been designed and realized in order to optimize the characteristics of laser-induced breakdown spectroscopy system working in various pressure environments. An approach combined the normaliza... An experimental setup has been designed and realized in order to optimize the characteristics of laser-induced breakdown spectroscopy system working in various pressure environments. An approach combined the normalization methods with the partial least squares(PLS) method are developed for quantitative analysis of molybdenum(Mo) element in the multi-component alloy,which is the first wall material in the Experimental Advanced Superconducting Tokamak. In this study, the different spectral normalization methods(total spectral area normalization,background normalization, and reference line normalization) are investigated for reducing the uncertainty and improving the accuracy of spectral measurement. The results indicates that the approach of PLS based on inter-element interference is significantly better than the conventional PLS methods as well as the univariate linear methods in the various pressure for molybdenum element analysis. 展开更多
关键词 laser induced breakdown spectroscopy MOLYBDENUM VACUUM NORMALIZATION partial least SQUARES method quantitative analysis
下载PDF
Spectral Enhancement of Laser-Induced Breakdown Spectroscopy in External Magnetic Field 被引量:4
4
作者 李丞 高勋 +2 位作者 李奇 宋超 林景全 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期919-922,共4页
In this paper the spectral enhancement of laser-induced breakdown spectroscopy (LIBS) for copper plasma in the presence of a magnetic field is investigated and the temporal- and spatial-resolved plasma emission spec... In this paper the spectral enhancement of laser-induced breakdown spectroscopy (LIBS) for copper plasma in the presence of a magnetic field is investigated and the temporal- and spatial-resolved plasma emission spectra are analyzed. Experimental results show that the copper plasma atomic and ion spectra have been enhanced in the presence of the external magnetic field. In addition, the Cu I 521.82 nm spectral intensity evolution with delay time appears to have a double peak around the delay time of 2 μs, but that of Cu II 507.57 nm has a sharp decrease because of the electron-atom three body recombination process. The plasma temperature with magnetic confinement is lower than that of the case in the absence of magnetic fields. Finally, the spectral enhancement mechanisms of laser induced breakdown spectroscopy with magnetic confinement are analyzed. 展开更多
关键词 laser induced breakdown spectroscopy spectral enhancement magnetic confinement
下载PDF
Detection of heavy metals in water samples by laser-induced breakdown spectroscopy combined with annular groove graphite flakes 被引量:6
5
作者 Li FANG Nanjing ZHAO +5 位作者 Mingjun MA Deshuo MENG Yao JIA Xingjiu HUANG Wenqing LIU Jianguo LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期16-22,共7页
The use of laser-induced breakdown spectroscopy(LIBS) for the analysis of heavy metals in water samples is investigated. Some factors such as splashing, surface ripples, extinction of emitted intensity, and a shorter ... The use of laser-induced breakdown spectroscopy(LIBS) for the analysis of heavy metals in water samples is investigated. Some factors such as splashing, surface ripples, extinction of emitted intensity, and a shorter plasma lifetime will influence the results if the water sample is directly measured. In order to avoid these disadvantages and the ‘coffee-ring effect', hydrophilic graphite flakes with annular grooves were used for the first time to enrich and concentrate heavy metals in water samples before being analyzed by LIBS. The proposed method and procedure have been evaluated to concentrate and analyze cadmium, chromium, copper, nickel, lead,and zinc in a water sample. The correlation coefficients were all above 0.99. The detection limits of 0.029, 0.087, 0.012, 0.083, 0.125, and 0.049 mgl^(-1) for Cd, Cr, Cu, Ni, Pb, and Zn,respectively, were obtained in samples prepared in a laboratory. With this structure, the heavy metals homogeneously distribute in the annular groove and the relative standard deviations are all below 6%. This method is very convenient and suitable for online in situ analysis of heavy metals. 展开更多
关键词 laser-induced breakdown spectroscopy quantitative analysis heavy metals GRAPHITE FLAKE
下载PDF
Signal processing for real-time identification of similar metals by laser-induced breakdown spectroscopy 被引量:6
6
作者 Sungho SHIN Youngmin MOON +3 位作者 Jaepil LEE Hyemin JANG Euiseok HWANG Sungho JEONG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期84-91,共8页
Laser-induced breakdown spectroscopy(LIBS) is regarded as a promising technique for realtime sorting of scrap metals due to its capability of fast multi-elemental and in-air analysis. This work reports a method for si... Laser-induced breakdown spectroscopy(LIBS) is regarded as a promising technique for realtime sorting of scrap metals due to its capability of fast multi-elemental and in-air analysis. This work reports a method for signal processing which ensures high accuracy and high speed during similar metal sorting by LIBS. Similar metals such as aluminum alloys or stainless steel are characterized by nearly the same constituent elements with slight variations in elemental concentration depending on metal type. In the proposed method, the original data matrix is substantially reduced for fast processing by selecting new input variables(spectral lines) using the information for the constituent elements of similar metals. Specifically, principal component analysis(PCA) of full-spectra LIBS data was performed and then, based on the loading plots, the input variables of greater significance were selected in the order of higher weights for each constituent element. The results for the classification test with aluminum alloy, copper alloy,stainless steel and cast steel showed that the classification accuracy of the proposed method was nearly the same as that of full-spectra PCA, but the computation time was reduced by a factor of 20 or more. The results demonstrated that incorporating the information for constituent elements can significantly accelerate classification speed without loss of accuracy. 展开更多
关键词 laser-induced breakdown spectroscopy classification similar metal REDUCED number of SPECTRAL LINES
下载PDF
Analysis of Pulverized Coal by Laser-Induced Breakdown Spectroscopy 被引量:8
7
作者 余亮英 陆继东 +3 位作者 陈文 吴戈 沈凯 冯伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期3041-3044,共4页
Laser-induced breakdown spectroscopy (LIBS) has been used to detect atomic species in various enviromnents. The quantitative analysis (C, H, O, N and S) of representative coal samples are being carried out with LI... Laser-induced breakdown spectroscopy (LIBS) has been used to detect atomic species in various enviromnents. The quantitative analysis (C, H, O, N and S) of representative coal samples are being carried out with LIBS, and the effects of particle size are analyzed. A powerful pulse Nd:YAG laser is focused on the coal sample at atmosphere pressure, and the emission spectra from laser-induced plasmas are measured by time-resolved spectroscopy, and the intensity of analyzed spectral lines is obtained through observing the laser plasma with a delay time of 0.4 #s. The experimental results show that the slope of calibration curve is nearly 1 when the concentration of the analyzed element is relatively low, and the slope of curve is nearly 0.5 when the concentration of C is higher than other elements. In addition, using the calibration-free model without self-absorption effect, the results show that the decreasing of particle size leads to an increase of the plasma temperature. 展开更多
关键词 laser-induced breakdown spectroscopy element analysis SELF-ABSORPTION delay time
下载PDF
Laser Induced Breakdown Spectroscopy for Comparative Quantitative Analysis of Betel Leaves from Pakistan 被引量:1
8
作者 I Rehan K Rehan +1 位作者 S Sultana R Muhammad 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2018年第10期3295-3302,共8页
Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean ... Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean Optics,Inc)having the optical resolution of 0.06 nm was used to record the emission spectra from 220 to 720 nm.Elements like Al,Ba,Ca,Cr,Cu,P,Fe,K,Mg,Mn,Na,P,S,Sr,and Zn were found to present in the samples.The relative abundances of the observed elements were calculated through standard calibration curve method,integrated intensity ratio method,and weight percentage LIBS approach.LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of Inductively Coupled plasma-optical emission spectroscopy(ICP-OES).Limit of detection(LOD)of the LIBS system was also estimated for heavy metals.The experience gain through this work implies that LIBS could be highly applicable for testing the quality and purity of food products. 展开更多
关键词 laser induced breakdown spectroscopy(LIBS) Spectral analysis inductively coupled plasma-optical emission SPECTROMETRY Limit of detection(LOD)
下载PDF
A rapid classification method of aluminum alloy based on laser-induced breakdown spectroscopy and random forest algorithm 被引量:6
9
作者 Liuyang ZHAN Xiaohong MA +4 位作者 Weiqi FANG Rui WANG Zesheng LIU Yang SONG Huafeng ZHAO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期148-154,共7页
As an important non-ferrous metal structural material most used in industry and production,aluminum(Al) alloy shows its great value in the national economy and industrial manufacturing.How to classify Al alloy rapidly... As an important non-ferrous metal structural material most used in industry and production,aluminum(Al) alloy shows its great value in the national economy and industrial manufacturing.How to classify Al alloy rapidly and accurately is a significant, popular and meaningful task.Classification methods based on laser-induced breakdown spectroscopy(LIBS) have been reported in recent years. Although LIBS is an advanced detection technology, it is necessary to combine it with some algorithm to reach the goal of rapid and accurate classification. As an important machine learning method, the random forest(RF) algorithm plays a great role in pattern recognition and material classification. This paper introduces a rapid classification method of Al alloy based on LIBS and the RF algorithm. The results show that the best accuracy that can be reached using this method to classify Al alloy samples is 98.59%, the average of which is 98.45%. It also reveals through the relationship laws that the accuracy varies with the number of trees in the RF and the size of the training sample set in the RF. According to the laws, researchers can find out the optimized parameters in the RF algorithm in order to achieve,as expected, a good result. These results prove that LIBS with the RF algorithm can exactly classify Al alloy effectively, precisely and rapidly with high accuracy, which obviously has significant practical value. 展开更多
关键词 laser-induced breakdown spectroscopy(LIBS) RANDOM forest(RF) aluminum(Al)alloy classification
下载PDF
A comparison of single shot nanosecond and femtosecond polarization-resolved laser-induced breakdown spectroscopy of Al 被引量:4
10
作者 Nakimana Agnes 陶海岩 +3 位作者 郝作强 孙长凯 高勋 林景全 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第1期273-277,共5页
Aluminum samples have been analyzed by femtosecond polarization-resolved laser-induced breakdown spectroscopy (fs-PRLIBS). We compare the obtained spectra with those obtained from nanosecond PRLIBS (ns-PRLIBS). Th... Aluminum samples have been analyzed by femtosecond polarization-resolved laser-induced breakdown spectroscopy (fs-PRLIBS). We compare the obtained spectra with those obtained from nanosecond PRLIBS (ns-PRLIBS). The main specific features of fs-PRLIBS are that a lower plasma temperature leads to a low level of continuum and no species are detected from the ambient gas. Furthermore, signals obtained by fs-PRLIBS show a higher stability than those of ns-PRLIBS. However, more elements are detected in the ns-PRLIBS spectra. 展开更多
关键词 polarization-resolved laser-induced breakdown spectroscopy femtosecond laser nanosecond laser SHIELDING
下载PDF
Effect of parameter setting and spectral normalization approach on study of matrix effect by laser induced breakdown spectroscopy of Ag–Zn binary composites 被引量:1
11
作者 Harse SATTAR Liying SUN +3 位作者 Muhammad IMRAN Ran HAI Ding WU Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期155-166,共12页
The complex nature of laser-material interaction causes non-stoichiometric ablation of alloy samples.This is attributed to matrix effect, which reduces analyzing capability. To address this issue, the analytical perfo... The complex nature of laser-material interaction causes non-stoichiometric ablation of alloy samples.This is attributed to matrix effect, which reduces analyzing capability. To address this issue, the analytical performance of three different normalization methods, namely normalization with background, internal normalization and three point smoothing techniques at different parameter settings is studied for quantification of Ag and Zn by Laser induced breakdown spectroscopy(LIBS).The LIBS spectra of five known concentration of silver zinc binary composites have been investigated at various laser irradiances(LIs). Calibration curves for both Ag(I) line(4d^(10)5s^2S_(1/2)→4d^(10)5p^2P_(1/2) at 338.28 nm) and Zn(I) line(4s5s^3S_1→4s4p^3P_2 at 481.053 nm) have been determined at LI of 5.86?×?10^(10)W cm^(-2). Slopes of these calibration curves provide the valuation of matrix effect in the Ag–Zn composites. With careful sample preparation and normalization after smoothing at optimum parameter setting(OPS), the minimization of sample matrix effect has been successfully achieved. A good linearity has been obtained in Ag and Zn calibration curve at OPS when normalized the whole area of spectrum after smoothing and the obtained coefficients of determination values were R^2?=?0.995 and 0.998 closer to 1. The results of matrix effect have been further verified by analysis of plasma parameters. Both plasma parameters showed no change with varying concentration at OPS. However, at high concentration of Ag, the observed significant changes in both plasma parameters at common parameter setting PS-1 and PS-2 were the gesture of matrix effect. In our case, the better analytical results were obtained at smoothing function with optimized parameter setting that indicates it is more efficient than normalization with background and internal normalization method. 展开更多
关键词 Ag–Zn COMPOSITES laser induced breakdown spectroscopy optimum parameter setting SELF-ABSORPTION matrix EFFECT
下载PDF
Simultaneous Measurements of Coal Ash Composition by Laser-induced Breakdown Spectroscopy in Different Optical Collection 被引量:4
12
作者 YAO Shunchun LU Jidong DONG Meirong ZHENG Jianping LI Jun ZHANG Bo 《中国电机工程学报》 EI CSCD 北大核心 2013年第11期I0008-I0008,10,共1页
针对燃煤组分分布不均匀的特性,研究不同收光模式对激光诱导击穿光谱技术同步测量灰成分的影响。选用具有不同灰成分含量梯度的燃煤样品作为检测对象,对比分析同向收光和侧向收光下灰成分组成元素谱线信号探测的强度和稳定性及SiO2、A... 针对燃煤组分分布不均匀的特性,研究不同收光模式对激光诱导击穿光谱技术同步测量灰成分的影响。选用具有不同灰成分含量梯度的燃煤样品作为检测对象,对比分析同向收光和侧向收光下灰成分组成元素谱线信号探测的强度和稳定性及SiO2、Al2O3、Fe2O3、CaO、MgO和TiO2含量定量分析的精确度。研究结果表明,相同实验条件下同向收光模式的光谱信号稳定性和定量分析精确度更好,检验样品中各灰成分的预测值和参考值之间的拟合度均在0.986以上。而侧向收光模式下探测到的光谱信号强度更强,光谱探测下限可以达到190nm。 展开更多
关键词 激光诱导 光谱仪 粉煤灰 同时测量 击穿 眼镜 组成 安全经济运行
下载PDF
Quantitative analysis of C, Si, Mn, Ni, Cr and Cu in low-alloy steel under ambient conditions via laser-induced breakdown spectroscopy 被引量:5
13
作者 Dan LUO Ying LIU +3 位作者 Xiangyu LI Zhenyang ZHAO Shigong WANG Yong ZHANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第7期152-158,共7页
A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors,... A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors, such as laser pulse energy, repetition rate and argon flow rate, that influence laser-induced breakdown spectroscopy (LIBS) analytical performance are investigated in detail. Under the optimal experiment conditions, the relative standard deviations for C, Si, Mn, Ni, Cr and Cu are 3.3%-8.9%, 0.9%-2.8%, 1.2%-4.1%, 1.7%-3.0%, 1.1%-3.4% and 2.5%-8.5%, respectively, with the corresponding relative errors of 1.1%-7.9%, 1.0%-6.3%, 0.4%-3.9%, 1.5%-6.3%, 1.2%-4.0% and 1.2%-6.4%. Compared with the results of the traditional spark discharge optical emission spectrometry technique, the analytical performance of LIBS is just a little inferior due to the less stable laser-induced plasma and smaller amount of ablated sample by the laser. However, the precision, detection limits and accuracy of LIBS obtained in our present work were sufficient to meet the requirements for process analysis. These technical performances of higher stability of output energy and longer service life for DPSSL, in comparison to the Q-switch laser pumped by xeon lamp, qualify it well for the real time online analysis for different industrial applications. 展开更多
关键词 laser-induced breakdown spectroscopy (LIBS) diode-pumped solid-state laser(DPSSL) optical emission spectrometry laser-induced plasma
下载PDF
Laser-induced breakdown spectroscopy applied to the characterization of rock by support vector machine combined with principal component analysis 被引量:6
14
作者 杨洪星 付洪波 +3 位作者 王华东 贾军伟 Markus W Sigrist 董凤忠 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期290-295,共6页
Laser-induced breakdown spectroscopy(LIBS) is a versatile tool for both qualitative and quantitative analysis.In this paper,LIBS combined with principal component analysis(PCA) and support vector machine(SVM) is... Laser-induced breakdown spectroscopy(LIBS) is a versatile tool for both qualitative and quantitative analysis.In this paper,LIBS combined with principal component analysis(PCA) and support vector machine(SVM) is applied to rock analysis.Fourteen emission lines including Fe,Mg,Ca,Al,Si,and Ti are selected as analysis lines.A good accuracy(91.38% for the real rock) is achieved by using SVM to analyze the spectroscopic peak area data which are processed by PCA.It can not only reduce the noise and dimensionality which contributes to improving the efficiency of the program,but also solve the problem of linear inseparability by combining PCA and SVM.By this method,the ability of LIBS to classify rock is validated. 展开更多
关键词 laser-induced breakdown spectroscopy(LIBS) principal component analysis(PCA) support vector machine(SVM) lithology identification
下载PDF
Study of pressure effects on ocean in-situ detection using laser-induced breakdown spectroscopy 被引量:3
15
作者 Jinjia GUO Nan LI +1 位作者 Jiaojian SONG Ronger ZHENG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期182-187,共6页
Laser-induced breakdown spectroscopy(LIBS) has attracted extensive attention as a new technique for in-situ marine application. In this work, the influence of deep-sea high pressure environment on LIBS signals was inv... Laser-induced breakdown spectroscopy(LIBS) has attracted extensive attention as a new technique for in-situ marine application. In this work, the influence of deep-sea high pressure environment on LIBS signals was investigated by using a compact LIBS-sea system developed by Ocean University of China for the in-situ chemical analysis of seawater. The results from the field measurements show that the liquid pressure has a significant effect on the LIBS signals. Higher peak intensity and larger line broadening were obtained as the pressure increases. By comparing the variations of the temperature and salinity with the LIBS signals, a weak correlation between them can be observed. Under high pressure conditions, the optimal laser energy was higher than that in air environment. When the laser energy exceeded 17 mJ, the effect of laser energy on the signal intensity weakened. The signal intensity decreases gradually at larger delays. The obtained results verified the feasibility of the LIBS technique for the deep-sea in-situ detection, and we hope this technology can contribute to surveying more deep-sea environments such as the hydrothermal vent regions. 展开更多
关键词 laser-induced breakdown spectroscopy DEEP-SEA IN-SITU detection pressure effect plasma EMISSION
下载PDF
Improved Measurement Performance of Inorganic Elements in Coal by Laser-Induced Breakdown Spectroscopy Coupled with Internal Standardization 被引量:3
16
作者 姚顺春 徐嘉隆 +1 位作者 白凯杰 陆继东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期938-943,共6页
Laser-induced breakdown spectroscopy was employed to determine the inorganic elements in coal. To improve the measurement's accuracy and precision, a new internal standardization scheme, which we named changed intern... Laser-induced breakdown spectroscopy was employed to determine the inorganic elements in coal. To improve the measurement's accuracy and precision, a new internal standardization scheme, which we named changed internal standardization, was compared with the traditional internal standardization and no internal standardization for the analysis of inorganic elements. The new internal standardization scheme used the atomic line of carbon at 247.86 nm and the molecular band of CN at 388.34 nm and C2 at 516.32 nm to normalize the lines of inorganic elements that were distributed in the same spectral channel. The performance of the utilization of the new internal standardization scheme was evaluated using a set of coal samples, including twenty calibration samples and five validation samples. The results show that the coefficients of determination R2 and the slope of calibration models coupled with changed internal standard- ization are better than that of the calibration models coupled with fixed internal standardization and no internal standardization. Moreover, the measurement accuracy and reproducibility of changed internal standardization for the analysis of five validation samples also yielded further improvement. The results that we obtained suggest that changed internal standardization could compensate for the matrix effects, as well as the influence of the difference in the spectral response of the light collection system. 展开更多
关键词 laser-induced breakdown spectroscopy COAL internal standardization inorganic elements
下载PDF
Determination of Iron in Water Solution by Time-Resolved Femtosecond Laser-Induced Breakdown Spectroscopy 被引量:3
17
作者 Sergey S.GOLIK Alexey A.ILYIN +3 位作者 Michael Yu.BABIY Yulia S.BIRYUKOVA Vladimir V.LISITSA Oleg A.BUKIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期975-978,共4页
The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphi... The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection. 展开更多
关键词 femtosecond laser-induced breakdown spectroscopy LIBS femtosecond plasma IRON analysis of water atomic emission spectroscopy limit of detection
下载PDF
Cluster analysis of polymers using laser-induced breakdown spectroscopy with K-means 被引量:4
18
作者 Yangmin GUO Yun TANG +4 位作者 Yu DU Shisong TANG Lianbo GUO Xiangyou LI Yongfeng LU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第6期99-103,共5页
Laser-induced breakdown spectroscopy(LIBS) combined with K-means algorithm was employed to automatically differentiate industrial polymers under atmospheric conditions.The unsupervised learning algorithm K-means wer... Laser-induced breakdown spectroscopy(LIBS) combined with K-means algorithm was employed to automatically differentiate industrial polymers under atmospheric conditions.The unsupervised learning algorithm K-means were utilized for the clustering of LIBS dataset measured from twenty kinds of industrial polymers.To prevent the interference from metallic elements,three atomic emission lines(C I 247.86 nm,H I 656.3 nm,and O I 777.3 nm) and one molecular line C–N(0,0) 388.3 nm were used.The cluster analysis results were obtained through an iterative process.The Davies–Bouldin index was employed to determine the initial number of clusters.The average relative standard deviation values of characteristic spectral lines were used as the iterative criterion.With the proposed approach,the classification accuracy for twenty kinds of industrial polymers achieved 99.6%.The results demonstrated that this approach has great potential for industrial polymers recycling by LIBS. 展开更多
关键词 laser-induced breakdown spectroscopy polymers K-means
下载PDF
Quantitative Analysis of Cr in Milk Powder by Laser Induced Breakdown Spectroscopy( LIBS) 被引量:1
19
作者 Gangmeng GONG Jun YANG 《Agricultural Biotechnology》 CAS 2015年第6期66-69,共4页
At present, heavy metal pollution in food occurs frequently, which requires a novel method for rapid detection. Laser induced breakdown spectroscopy (LIBS) is a new technique for rapid and environmental friendly det... At present, heavy metal pollution in food occurs frequently, which requires a novel method for rapid detection. Laser induced breakdown spectroscopy (LIBS) is a new technique for rapid and environmental friendly detection, but it lacks high sensitivity and stability which restrict its development. In this study, Cr-polluted infant milk powder was used as experimental material to explore the feasibility of the application of LIBS technique in food safety detection. Aiming at improving the precision and accuracy of Cr detection by LIBS technique, LIBS spectra of samples were collected by a spectrometer with an intensified charge-cou- pled device (ICCD) using three gratings with different resolutions to comprehensively compare and analyze the stability, sensitivity and quantitative analysis accura- cy of LIBS detection. The results showed that average relative standard deviation (RSD) of LIBS spectral intensity was below 10%, indicating good stability. LIBS signals were collected by three gratings for quantitative analysis, and the results demonstrated that the linear correlation coefficient R2 of fitting curves was 0. 248 87, 0.903 12 and 0.992 81, respectively; the relative errors between actual and predicted concentrations were 38.23%, 8.84% and 7.43%, respectively, indicating that gratings with higher resolutions could lead to higher linear correlation coefficient and better detection accuracy. According to the results, high-resolu- tion spectrometer could significantly improve the accuracy of LIBS detection of Cr concentration in milk powder, suggesting that it is feasible to detect heavy metals in food by LIBS technique with the improvement of core device performance. 展开更多
关键词 laser induced breakdown spectroscopy Milk powder Spectral resolution CR
下载PDF
Rock and Soil Classification Using PLS-DA and SVM Combined with a Laser-Induced Breakdown Spectroscopy Library 被引量:6
20
作者 杨光 乔淑君 +2 位作者 陈鹏飞 丁宇 田地 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期656-663,共8页
Laser-induced breakdown spectroscopy (LIBS) has become a powerful technology in geological applications. The correct identification of rocks and soils is critical to many geological projects. In this study, LIBS dat... Laser-induced breakdown spectroscopy (LIBS) has become a powerful technology in geological applications. The correct identification of rocks and soils is critical to many geological projects. In this study, LIBS database software with a user-friendly and intuitive interface is developed based on Windows, consisting of a database module and a sample identification module. The database module includes a basic database containing LIBS persistent lines for elements and a dedicated geological database containing LIBS emission lines for several rock and soil reference standards. The module allows easy use of the data. A sample identification module based on partial least squares discriminant analysis (PLS-DA) or support vector machine (SVM) algorithms enables users to classify groups of unknown spectra. The developed system was used to classify rock and soil data sets in a dedicated database and the results demonstrate that the system is capable of fast and accurate classification of rocks and soils, and is thus useful for the detection of geological materials. 展开更多
关键词 laser-induced breakdown spectroscopy spectral database geomaterial clas-sification partial least squares discriminant analysis (PLS-DA) support vector machine(SVM)