期刊文献+
共找到369篇文章
< 1 2 19 >
每页显示 20 50 100
Analytical Model and Topology Optimization of Doubly-fed Induction Generator
1
作者 Lu Sun Haoyu Kang +4 位作者 Jin Wang Zequan Li Jianjun Liu Yiming Ma Libing Zhou 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期162-169,共8页
As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and ... As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method. 展开更多
关键词 doubly-fed induction generators Accurate subdomain model Surrogate-assisted Transfer learning
下载PDF
Modeling and small-signal stability analysis of doubly-fed induction generator integrated system 被引量:1
2
作者 Tianming Gu Puyu Wang +3 位作者 Dingyuan Liu Ao Sun Dejian Yang Gangui Yan 《Global Energy Interconnection》 EI CSCD 2023年第4期438-449,共12页
Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the w... Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC. 展开更多
关键词 doubly-fed induction generator(DFIG) Maximum power point tracking DICHOTOMY Small-signal stability
下载PDF
Robust Position Observer for Sensorless Direct Voltage Control of Stand-Alone Ship Shaft Brushless Doubly-Fed Induction Generators 被引量:4
3
作者 Mohamed G.Hussien Yi Liu Wei Xu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期363-376,共14页
The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser... The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes. 展开更多
关键词 Brushless doubly-fed induction generator(BDFIG) direct voltage control(DVC) PW voltage-oriented vector control rotor position observer ship shaft applications.
下载PDF
A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
4
作者 沈阳武 柯德平 +3 位作者 孙元章 Daniel Kirschen 王轶申 胡元朝 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt... A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. 展开更多
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support
下载PDF
Step-Loading Characteristics of Gas Engine Cogeneration System Using Doubly-Fed Induction Generator in Stand-Alone Operation
5
作者 Tetsuji Daido Yushi Miura +1 位作者 Toshifumi Ise Yuki Sato 《Journal of Energy and Power Engineering》 2014年第3期530-542,共13页
Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supp... Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading. 展开更多
关键词 Step load change doubly-fed induction generator gas engine cogeneration system stand-alone operation.
下载PDF
Parameter Deviation Effect Study of the Power Generation Unit on a Doubly-Fed Induction Machine-based Shipboard Propulsion System 被引量:2
6
作者 Kai Ni Yihua Hu Chun Gan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期339-348,共10页
To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a syn... To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS. 展开更多
关键词 shipboard propulsion system partially power decoupled doubly-fed induction machine synchronous generator parameter deviation
下载PDF
A novel control strategy of a variable-speed doubly-fed-induction-generator-based wind energy conversion system
7
作者 Shibani Prasad Mohapatra Pradipta Kishore Dash 《Clean Energy》 EI CSCD 2024年第1期153-170,共18页
This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction g... This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction generator-based variable-speed wind turbine by controlling the rotor current. In the first step, a maximum power point tracking technique is used to extract the maximum power from theturbine. Then a stator-flux-oriented vector control strategy is employed to control the rotor-side current. Subsequently, a grid voltagevector-oriented control strategy is used to control the grid-side system of the grid-connected generator. Considering the nonlinearityand parameter uncertainty of the system, an active disturbance rejection controller with a sliding-mode-based extended-state observeris developed for the above-mentioned control strategies. Furthermore, the stability of the controller is tested and the performance of thecontroller is compared with the classical proportional-integral controller based on disturbance rejection, robustness and tracking capability in a highly non-linear wind speed variation scenario. Modelling, control and comparison are conducted in the MATLAB®/Simulink®environment. Finally, a real-time hardware set-up is presented using the dSPACE ds-1104 R&D processing board to validate the controlscheme. From the result of the experiments, it is seen that the proposed controller takes 10-15 control cycles to settle to its steady-statevalues, depending on the control loop, whereas the conventional proportional-integral controller takes 60-75 control cycles. As a result,the settling time for the proposed control scheme is shorter than that of the proportional-integral controller. 展开更多
关键词 doubly-fed induction generator variable-speed wind turbine vector control active disturbance rejection controller stability analysis
原文传递
A Reliable and Accurate Calculation of Excitation Capacitance Value for an Induction Generator Based on Interval Computation Technique
8
作者 Rajesh Kumar Thakur Vivek Agarwal Paluri S. V. Nataraj 《International Journal of Automation and computing》 EI 2011年第4期429-436,共8页
A squirrel cage induction generator (SCIG) offers many advantages for wind energy conversion systems but suffers from poor voltage regulation under varying operating conditions. The value of excitation capacitance ... A squirrel cage induction generator (SCIG) offers many advantages for wind energy conversion systems but suffers from poor voltage regulation under varying operating conditions. The value of excitation capacitance (C exct ) is very crucial for the selfexcitation and voltage build-up as well as voltage regulation in SCIG. Precise calculation of the value of C exct is, therefore, of considerable practical importance. Most of the existing calculation methods make use of the steady-state model of the SCIG in conjunction with some numerical iterative method to determine the minimum value of C exct . But this results in over estimation, leading to poor transient dynamics. This paper presents a novel method, which can precisely calculate the value of C exct by taking into account the behavior of the magnetizing inductance during saturation. Interval analysis has been used to solve the equations. In the proposed method, a range of magnetizing inductance values in the saturation region are included in the calculation of C exct , required for the self-excitation of a 3-φ induction generator. Mathematical analysis to derive the basic equation and application of interval method is presented. The method also yields the magnetizing inductance value in the saturation region which corresponds to an optimum C exct(min) value. The proposed method is experimentally tested for a 1.1 kW induction generator and has shown improved results. 展开更多
关键词 d-q model hull consistency induction generator interval analysis interval arithmetic optimization range of interval realpaver SELF-EXCITATION transients.
下载PDF
Modeling of Slab Induction Heating in Hot Rolling by FEM
9
作者 Ruibin Mei Changsheng Li +2 位作者 Xianghua Liu Bao Li Bin Han 《Engineering(科研)》 2011年第4期364-370,共7页
FEM (Finite Element Method) has been widely used to solve temperature in hot rolling. The heat gen-erating rate of electromagnetic field has been discussed in order to improve the efficiency and accuracy in the soluti... FEM (Finite Element Method) has been widely used to solve temperature in hot rolling. The heat gen-erating rate of electromagnetic field has been discussed in order to improve the efficiency and accuracy in the solution of induction heating. A new heat generating rate model was proposed and derived from the calculated results by FEM software in consideration of work frequency, source current density, and the air gap between induction coil and slab. The calculated distribution of heat generating rate in the skin depth by the model is satisfying and reliable compared with that of FEM software. Then, the mathematic model of the heat generating rate model is considered as the density of heat reservoir to solve the temperature in induction heating. Moreover, the temperature evolution of slab in induction heating from a hot rolling plant has been solved by the developed FE code and the calculated temperature has a good agreement with the measured value. Therefore, the heat generating rate model is suitable and efficiency to solve the temperature in induction heating by FEM. 展开更多
关键词 FEM induction Heating Heat generATING Rate model Hot ROLLING Temperature
下载PDF
Application of fuzzy logic control algorithm as stator power controller of a grid-connected doubly-fed induction generator 被引量:1
10
作者 Ridha CHEIKH Arezki MENACER +1 位作者 Said DRID Mourad TIAR 《Frontiers in Energy》 SCIE CSCD 2013年第1期49-55,共7页
This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems. The DFIG structure control has a six diode rectifier and a PWM IGBT conve... This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems. The DFIG structure control has a six diode rectifier and a PWM IGBT converter in order to control the power outputs of the DFIG driven by wind turbine. So, to supply commercially the electrical power to the grid without any problems related to power quality, the active and reactive powers (Ps, Qs) at the stator side of the DFIG are strictly controlled at a required level, which, in this paper, is realized with an optimized fuzzy logic controller based on the grid flux oriented control, which gives an optimal operation of the DFIG in sub-synchronous region, and the control of the stator power flow with the possibility of keeping stator power factor at a unity. 展开更多
关键词 doubly-fed induction generator (DFIG) vector control fuzzy logic controller optimization power factor unity active and reactive power
原文传递
Doubly-fed induction generator drive based WECS using fuzzy logic controller 被引量:1
11
作者 Abdelhak DIDA Djilani BEN ATTOUS 《Frontiers in Energy》 SCIE CSCD 2015年第3期272-281,共10页
The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The cont... The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The control of the rotor-side converter is realized by stator flux oriented control, whereas the control of the grid-side converter is performed by a control strategy based on grid voltage orientation to maintain the DC-link voltage stability. An intelligent fuzzy inference system is proposed as an alternative of the conventional proportional and integral (PI) controller to overcome any disturbance, such as fast wind speed variation, short grid voltage fault, parameter variations and so on. Five fuzzy logic controllers are used in the rotor side converter (RSC) for maximum power point tracking (MPPT) algorithm, active and reactive power control loops, and another two fuzzy logic controllers for direct and quadratic rotor currents components control loops. The performances have been tested on 1.5 MW doubly-fed induction generator (DFIG) in a Matlab/Simulink software environment. 展开更多
关键词 fuzzy logic wind turbine vector control doubly-fed induction generator (DFIG)
原文传递
Modern Control Strategies of Doubly-Fed Induction Generator Based Wind Turbine System 被引量:2
12
作者 Dao Zhou Yipeng Song Frede Blaabjerg 《Chinese Journal of Electrical Engineering》 2016年第1期13-23,共11页
A doubly-fed induction generator(DFIG)based configuration is still preferred by wind turbine manufacturers due to the cost-effective power converter and independent control of the active power and reactive power.To co... A doubly-fed induction generator(DFIG)based configuration is still preferred by wind turbine manufacturers due to the cost-effective power converter and independent control of the active power and reactive power.To cope with stricter grid codes(e.g.reactive power compensation,low voltage ride-through operation,as well as steady and safe operation during long-term distorted grid),control strategies are continuously evolving.This paper starts with a control strategy using the combined reactive power compensation from both the back-to-back power converters for their optimized lifetime distribution under normal grid conditions.Afterwards,an advanced demagnetizing control is proposed to keep the minimum thermal stress of the rotor-side converter in the case of the short-term grid fault.A modularized control strategy of the DFIG system under unbalanced and distorted grid voltage is discussed,with the control targets of the smooth active and reactive power or the balanced and sinusoidal current of the rotor-side converter and the grid-side converte。Finally,a bandwidth based repetitive controller is evaluated to improve the DFIG system's robustness against grid frequency deviation. 展开更多
关键词 doubly-fed induction generator reactive power low voltage ride-through unbalanced and distorted grid.
原文传递
Thermoelectric Energy Conversion of a Drinking Bird by Disk-Magnet Electromagnetic Induction 被引量:3
13
作者 Hiroshi Uechi Schun T. Uechi 《World Journal of Engineering and Technology》 2020年第2期204-216,共13页
We discuss a thermoelectric energy generation (TEG) technique by employing a thermomechanical model of a drinking bird (DB). The motion of a drinking bird is produced by the entropy-flow explained by the second law of... We discuss a thermoelectric energy generation (TEG) technique by employing a thermomechanical model of a drinking bird (DB). The motion of a drinking bird is produced by the entropy-flow explained by the second law of thermodynamics, which is one of the fundamental laws of heat engines. We propose a disk-magnet electromagnetic induction (DM-EMI) employed to the motion of a drinking bird. The generalization of DM-EMI to heat engines for?mechanoelectric?energy conversions and properties of extracted electric powers are specifically discussed. The electric power of DM-EMI has a limited power generation characteristic to a mechanical rotation produced by heat engines, but it will be very useful for practical applications to wind turbines, coal-fired and nuclear power plant for?mechanoelectric?energy conversions. The DM-EMI will contribute to environmental problems to maintain clean and susceptible energy as one of?energy?harvesting technologies. 展开更多
关键词 Mechanoelectric Energy generation (MEG) THERMOMECHANICAL model of a DRINKING BIRD (DB) Disk-Magnet Electromagnetic induction (DM-EMI)
下载PDF
Analysis on Effect of Parameters of Different Wind Generator on Power Grid Transient Stability
14
作者 Zhi-wei Wen Li Ding Shi-en He 《Energy and Power Engineering》 2013年第4期363-367,共5页
To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different... To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different wind farm integration on grid typically in China has been presented. The influence of the variations of transient reactance, negative sequence reactance and rotary inertia on critical clearing time of power system transient stability is analyzed by time-domain simulation. Mixture operation of DFIG and PMSG to optimize the stability of system has been analyzed firstly. The digital simulation results show that doubly-fed induction wind turbines is a better choice to meet the requirement of system instability due to large wind farm integration in comparison with direct-drive PM synchronous wind turbines. With a rather large rotary inertia, the proper ratio of direct-drive PM synchronous wind turbines used in wind farm could be comprehensive planning by optimized the stability of system. Analysis of this paper should be provided as academic reference for improving design of wind farm system. 展开更多
关键词 Wind FARM doubly-fed induction generator DIRECT-DRIVE PM SYNCHRONOUS generator Parameter
下载PDF
Coordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms
15
作者 B. Bak-Jensen T.A. Kawady M.H. Abdel-Rahman 《Journal of Energy and Power Engineering》 2010年第4期20-29,共10页
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capa... Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation. 展开更多
关键词 Wind farms protection dynamic modeling MATLAB-SIMULINK FUSE doubly-fed induction generators
下载PDF
计及低电压穿越及故障全过程动态的双馈风电场等值方法 被引量:1
16
作者 周海强 崔晓丹 +3 位作者 许剑冰 曹博源 高超 陈志昊 《电力系统自动化》 EI CSCD 北大核心 2024年第6期216-225,共10页
在分析双馈感应发电机(DFIG)故障各阶段动态的基础上,提出了一种计及低电压穿越控制的双馈风电场等值方法。首先,讨论了低电压穿越控制策略,给出了含双馈风电场的电力系统故障稳态潮流计算方法。在考虑电压暂态过程的条件下,分析了外部... 在分析双馈感应发电机(DFIG)故障各阶段动态的基础上,提出了一种计及低电压穿越控制的双馈风电场等值方法。首先,讨论了低电压穿越控制策略,给出了含双馈风电场的电力系统故障稳态潮流计算方法。在考虑电压暂态过程的条件下,分析了外部系统短路故障后DFIG转子电流的变化机理,指出电压跌落深度及风电功率是影响短路电流的主要因素,可根据动作分界线判断撬棒是否动作。然后,根据初始风速及撬棒状态将风电场中的DFIG分为3群,并对等值DFIG及集电网络进行聚合。为提高等值模型在恢复阶段的精度,根据故障稳态电压对双馈风电场功率恢复曲线进行预估,并在此基础上对等值DFIG恢复速率进行分段修正。最后,对含双馈风电场的算例系统进行了等值计算。仿真结果表明,等值模型较好地保持了原系统在故障各阶段的动态,在保持较高精度的前提下有效简化了系统,提高了计算速度。 展开更多
关键词 双馈感应发电机 风电场 低电压穿越 电力潮流 撬棒 动态等值 等值模型 功率恢复
下载PDF
基于传递函数分析的双馈风力发电系统动态建模方法研究
17
作者 夏越 张鸿飞 +4 位作者 陈颖 杜松怀 苏娟 刘露 沈沉 《中国电机工程学报》 EI CSCD 北大核心 2024年第12期4759-4774,I0013,共17页
以双馈风力发电系统(doubly-fed induction generator based wind energy conversion system,DFIG-based WECS)为例,利用小信号分析法推导出由风机、双质量块传动链构成的动力与传动系统通用传递函数方程。动力与传动系统传递函数的零... 以双馈风力发电系统(doubly-fed induction generator based wind energy conversion system,DFIG-based WECS)为例,利用小信号分析法推导出由风机、双质量块传动链构成的动力与传动系统通用传递函数方程。动力与传动系统传递函数的零极点位置、稳定性与系统参数及系统运行工作点相关。该传递函数可进一步分解为扭转分量和非扭转分量。传动链参数仅对扭转分量造成影响。在此基础上,建立了考虑动力传动、电机、变流器、控制等环节的风力发电系统传递函数模型。模型综合了各环节参数,可直观反映系统参数对系统响应的影响,有助于深入了解系统动态行为。算例及时域仿真结果证明了所提出传递函数模型的准确性和高效性,可为系统参数设计研究提供理论依据。 展开更多
关键词 传递函数 双馈风力发电系统(DFIG-based WECS) 小信号分析 动力传动系统模型
下载PDF
适应并离网模式切换的DFIG电磁暂态仿真建模
18
作者 于光耀 杨帮宇 +3 位作者 李振斌 崇志强 李惠玲 黄丽妍 《电网与清洁能源》 CSCD 北大核心 2024年第2期95-102,共8页
目前,常用的商业仿真软件中的双馈式感应发电机(double-fed Induction Generator,DFIG)模型通常不支持离网运行模式,难以实现风力发电系统由离网到并网的全过程电磁暂态仿真,对电力系统仿真分析工作带来极大不便。研究适应并离网模式切... 目前,常用的商业仿真软件中的双馈式感应发电机(double-fed Induction Generator,DFIG)模型通常不支持离网运行模式,难以实现风力发电系统由离网到并网的全过程电磁暂态仿真,对电力系统仿真分析工作带来极大不便。研究适应并离网模式切换的DFIG电磁暂态仿真建模方法。基于模块化思想分别对风力机、异步电机、变流器以及断路器进行建模,在系统组装形成DFIG风力发电系统电磁暂态仿真模型。提出了适应并离网模式切换的DFIG受控源等效电路模型和离散时间域实现方法,通过设计状态变量矩阵元素的截取和扩充算法实现了模型在并离网模式下的无缝衔接。在MATLAB/Simulink中搭建DFIG发电系统模型对所提方法和模型进行验证,仿真结果表明,所提建模方法能够很好地支持DFIG离网运行模式,实现DFIG由离网到并网的全过程电磁暂态仿真。 展开更多
关键词 双馈式感应发电机(DFIG) 并离网切换 电磁暂态仿真 建模方法
下载PDF
Phase–amplitude model for doubly fed induction generators 被引量:3
19
作者 Hua HUANG Ping JU +3 位作者 Xueping PAN Yuqing JIN Xiaoming YUAN Yuan GAO 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第2期369-379,共11页
The doubly fed induction generator(DFIG) is major type of wind turbine generator used in grid-connected wind farms. Practical models of DFIG have been built to study the influence of wind power generation on power sys... The doubly fed induction generator(DFIG) is major type of wind turbine generator used in grid-connected wind farms. Practical models of DFIG have been built to study the influence of wind power generation on power system dynamics. However, most existing practical models of the DFIG are based on rectangular coordinates,in which frequency variation is neglected. In this paper, a phase-amplitude(P-A) model is proposed for a DFIG based on phase and amplitude of the internal voltage. The model structure is much like that of the synchronous generator, and the rotor voltage can manipulate both the amplitude and the phase of the internal voltage.Comparisons have been made between the new P-A model of the DFIG and the synchronous generator model,as well as the asynchronous motor model.The contributions of the new P-A model of the DFIG are discussed and it is demonstrated that the proposed model has better ability in describing power system dynamic phenomena such as voltage dynamics and structural dynamics. Simulation results and a field test validate these contributions. 展开更多
关键词 DOUBLY fed induction generator(DFIG) model Internal VOLTAGE VOLTAGE DYNAMICS Frequency DYNAMICS
原文传递
计及风力发电机转速安全约束的DFIG一次调频模型预测控制策略
20
作者 周涛 张锋杨 +2 位作者 徐妍 王亚伦 纪子洋 《南京理工大学学报》 CAS CSCD 北大核心 2024年第2期155-164,共10页
针对传统方法控制双馈感应发电机(DFIG)的调频效果过于依赖参数整定的问题,该文提出了一种基于模型预测控制(MPC),计及转速安全约束的风力发电机参与一次调频控制策略。该方法结合风力发电机动力学模型与频率响应模型建立预测模型,通过... 针对传统方法控制双馈感应发电机(DFIG)的调频效果过于依赖参数整定的问题,该文提出了一种基于模型预测控制(MPC),计及转速安全约束的风力发电机参与一次调频控制策略。该方法结合风力发电机动力学模型与频率响应模型建立预测模型,通过线性回归方法变参考值将风力发电机转速的稳定性纳入考虑。相较于虚拟惯性控制等方法将系统频率偏差与转子动能直接关联,该文方法通过建立全新的预测模型,实时统筹考虑整个系统的状态信息,无需反复调整参数,在考虑转速安全性的同时兼顾全局性能。最后,通过实际算例分析验证了该文调频策略的有效性以及相对现有方法的优越性。 展开更多
关键词 双馈感应发电机 一次调频 频率响应模型 模型预测控制 转子动能控制 虚拟惯性控制 转速安全 线性回归
下载PDF
上一页 1 2 19 下一页 到第
使用帮助 返回顶部