期刊文献+
共找到72篇文章
< 1 2 4 >
每页显示 20 50 100
Analytical Model and Topology Optimization of Doubly-fed Induction Generator
1
作者 Lu Sun Haoyu Kang +4 位作者 Jin Wang Zequan Li Jianjun Liu Yiming Ma Libing Zhou 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期162-169,共8页
As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and ... As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method. 展开更多
关键词 doubly-fed induction generators Accurate subdomain model Surrogate-assisted Transfer learning
下载PDF
Modeling and small-signal stability analysis of doubly-fed induction generator integrated system 被引量:1
2
作者 Tianming Gu Puyu Wang +3 位作者 Dingyuan Liu Ao Sun Dejian Yang Gangui Yan 《Global Energy Interconnection》 EI CSCD 2023年第4期438-449,共12页
Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the w... Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC. 展开更多
关键词 doubly-fed induction generator(DFIG) Maximum power point tracking DICHOTOMY Small-signal stability
下载PDF
Robust Position Observer for Sensorless Direct Voltage Control of Stand-Alone Ship Shaft Brushless Doubly-Fed Induction Generators 被引量:4
3
作者 Mohamed G.Hussien Yi Liu Wei Xu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期363-376,共14页
The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser... The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes. 展开更多
关键词 Brushless doubly-fed induction generator(BDFIG) direct voltage control(DVC) PW voltage-oriented vector control rotor position observer ship shaft applications.
下载PDF
Parameter Deviation Effect Study of the Power Generation Unit on a Doubly-Fed Induction Machine-based Shipboard Propulsion System 被引量:2
4
作者 Kai Ni Yihua Hu Chun Gan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期339-348,共10页
To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a syn... To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS. 展开更多
关键词 shipboard propulsion system partially power decoupled doubly-fed induction machine synchronous generator parameter deviation
下载PDF
A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
5
作者 沈阳武 柯德平 +3 位作者 孙元章 Daniel Kirschen 王轶申 胡元朝 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt... A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. 展开更多
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support
下载PDF
Step-Loading Characteristics of Gas Engine Cogeneration System Using Doubly-Fed Induction Generator in Stand-Alone Operation
6
作者 Tetsuji Daido Yushi Miura +1 位作者 Toshifumi Ise Yuki Sato 《Journal of Energy and Power Engineering》 2014年第3期530-542,共13页
Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supp... Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading. 展开更多
关键词 Step load change doubly-fed induction generator gas engine cogeneration system stand-alone operation.
下载PDF
Application of fuzzy logic control algorithm as stator power controller of a grid-connected doubly-fed induction generator 被引量:1
7
作者 Ridha CHEIKH Arezki MENACER +1 位作者 Said DRID Mourad TIAR 《Frontiers in Energy》 SCIE CSCD 2013年第1期49-55,共7页
This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems. The DFIG structure control has a six diode rectifier and a PWM IGBT conve... This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems. The DFIG structure control has a six diode rectifier and a PWM IGBT converter in order to control the power outputs of the DFIG driven by wind turbine. So, to supply commercially the electrical power to the grid without any problems related to power quality, the active and reactive powers (Ps, Qs) at the stator side of the DFIG are strictly controlled at a required level, which, in this paper, is realized with an optimized fuzzy logic controller based on the grid flux oriented control, which gives an optimal operation of the DFIG in sub-synchronous region, and the control of the stator power flow with the possibility of keeping stator power factor at a unity. 展开更多
关键词 doubly-fed induction generator (DFIG) vector control fuzzy logic controller optimization power factor unity active and reactive power
原文传递
Doubly-fed induction generator drive based WECS using fuzzy logic controller 被引量:1
8
作者 Abdelhak DIDA Djilani BEN ATTOUS 《Frontiers in Energy》 SCIE CSCD 2015年第3期272-281,共10页
The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The cont... The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The control of the rotor-side converter is realized by stator flux oriented control, whereas the control of the grid-side converter is performed by a control strategy based on grid voltage orientation to maintain the DC-link voltage stability. An intelligent fuzzy inference system is proposed as an alternative of the conventional proportional and integral (PI) controller to overcome any disturbance, such as fast wind speed variation, short grid voltage fault, parameter variations and so on. Five fuzzy logic controllers are used in the rotor side converter (RSC) for maximum power point tracking (MPPT) algorithm, active and reactive power control loops, and another two fuzzy logic controllers for direct and quadratic rotor currents components control loops. The performances have been tested on 1.5 MW doubly-fed induction generator (DFIG) in a Matlab/Simulink software environment. 展开更多
关键词 fuzzy logic wind turbine vector control doubly-fed induction generator (DFIG)
原文传递
Modern Control Strategies of Doubly-Fed Induction Generator Based Wind Turbine System 被引量:2
9
作者 Dao Zhou Yipeng Song Frede Blaabjerg 《Chinese Journal of Electrical Engineering》 2016年第1期13-23,共11页
A doubly-fed induction generator(DFIG)based configuration is still preferred by wind turbine manufacturers due to the cost-effective power converter and independent control of the active power and reactive power.To co... A doubly-fed induction generator(DFIG)based configuration is still preferred by wind turbine manufacturers due to the cost-effective power converter and independent control of the active power and reactive power.To cope with stricter grid codes(e.g.reactive power compensation,low voltage ride-through operation,as well as steady and safe operation during long-term distorted grid),control strategies are continuously evolving.This paper starts with a control strategy using the combined reactive power compensation from both the back-to-back power converters for their optimized lifetime distribution under normal grid conditions.Afterwards,an advanced demagnetizing control is proposed to keep the minimum thermal stress of the rotor-side converter in the case of the short-term grid fault.A modularized control strategy of the DFIG system under unbalanced and distorted grid voltage is discussed,with the control targets of the smooth active and reactive power or the balanced and sinusoidal current of the rotor-side converter and the grid-side converte。Finally,a bandwidth based repetitive controller is evaluated to improve the DFIG system's robustness against grid frequency deviation. 展开更多
关键词 doubly-fed induction generator reactive power low voltage ride-through unbalanced and distorted grid.
原文传递
Analysis on Effect of Parameters of Different Wind Generator on Power Grid Transient Stability
10
作者 Zhi-wei Wen Li Ding Shi-en He 《Energy and Power Engineering》 2013年第4期363-367,共5页
To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different... To analyze the factors which affecting transient stability of power system, the dynamic model of doubly-fed induction generator and direct-drive PM synchronous generator has been built using PSCAD. Impact of different wind farm integration on grid typically in China has been presented. The influence of the variations of transient reactance, negative sequence reactance and rotary inertia on critical clearing time of power system transient stability is analyzed by time-domain simulation. Mixture operation of DFIG and PMSG to optimize the stability of system has been analyzed firstly. The digital simulation results show that doubly-fed induction wind turbines is a better choice to meet the requirement of system instability due to large wind farm integration in comparison with direct-drive PM synchronous wind turbines. With a rather large rotary inertia, the proper ratio of direct-drive PM synchronous wind turbines used in wind farm could be comprehensive planning by optimized the stability of system. Analysis of this paper should be provided as academic reference for improving design of wind farm system. 展开更多
关键词 Wind FARM doubly-fed induction generator DIRECT-DRIVE PM SYNCHRONOUS generator Parameter
下载PDF
Coordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms
11
作者 B. Bak-Jensen T.A. Kawady M.H. Abdel-Rahman 《Journal of Energy and Power Engineering》 2010年第4期20-29,共10页
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capa... Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaafarana, Egypt. The simulation results show the influence of the FRT capability on the protective relaying coordination in wind farms, showing that the FRT may work in situations where is were expected not to work, and then disabling the over-current protection, which should have worked in this situation. 展开更多
关键词 Wind farms protection dynamic modeling MATLAB-SIMULINK FUSE doubly-fed induction generators
下载PDF
大规模风电接入场景下的失步振荡中心定位方法
12
作者 李振兴 崔丹阳 +2 位作者 胡聪 朱益 翁汉琍 《电力系统保护与控制》 EI CSCD 北大核心 2024年第14期1-12,共12页
振荡中心的准确定位是失步保护正确动作的基础,大规模风电并网导致系统阻抗参数发生变化,使得传统基于阻抗轨迹的失步定位方法的适应性严重下降。针对该问题,提出基于节点频差的失步振荡中心定位方法。首先分析大规模风电并网对系统总... 振荡中心的准确定位是失步保护正确动作的基础,大规模风电并网导致系统阻抗参数发生变化,使得传统基于阻抗轨迹的失步定位方法的适应性严重下降。针对该问题,提出基于节点频差的失步振荡中心定位方法。首先分析大规模风电并网对系统总阻抗的影响。进一步根据发电机功角,计算其曼哈顿距离相似度并构建启动判据。最后,通过移动平均法对广域测量频率进行平滑处理,提出基于节点频差的失步振荡中心定位方法。仿真验证表明,所提基于节点频差的失步振荡中心定位方法受噪声影响较小,不受风电渗透率的影响,能够准确定位失步振荡中心位置。 展开更多
关键词 双馈风机 风电渗透率 等效阻抗 同步机组失步 节点电压频差 振荡中心定位
下载PDF
A Long-Range Generalized Predictive Control Algorithm for a DFIG Based Wind Energy System 被引量:1
13
作者 J.S.Solis-Chaves Lucas L.Rodrigues +1 位作者 C.M.Rocha-Osorio Alfeu J.Sguarezi Filho 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第5期1209-1219,共11页
This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations t... This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based. This controller uses the state space equations that consider the rotor current and voltage as state and control variables, to execute the predictive control action. Therefore, the model of the plant must be transformed into two discrete transference functions, by means of an auto-regressive moving average model, in order to attain a discrete and decoupled controller, which makes it possible to treat it as two independent single-input single-output systems instead of a magnetic coupled multiple-input multiple-output system. For achieving that, a direct power control strategy is used, based on the past and future rotor currents and voltages estimation. The algorithm evaluates the rotor current predictors for a defined prediction horizon and computes the new rotor voltages that must be injected to controlling the stator active and reactive powers. To evaluate the controller performance, some simulations were made using Matlab/Simulink. Experimental tests were carried out with a small-scale prototype assuming normal operating conditions with constant and variable wind speed profiles. Finally, some conclusions respect to the dynamic performance of this new controller are summarized. 展开更多
关键词 Direct power CONTROL doubly-fed induction generator flux oriented CONTROL generalized PREDICTIVE CONTROL LONG-RANGE PREDICTIVE CONTROL wind energy systems
下载PDF
A novel control strategy of a variable-speed doubly-fed-induction-generator-based wind energy conversion system
14
作者 Shibani Prasad Mohapatra Pradipta Kishore Dash 《Clean Energy》 EI 2024年第1期153-170,共18页
This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction g... This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction generator-based variable-speed wind turbine by controlling the rotor current. In the first step, a maximum power point tracking technique is used to extract the maximum power from theturbine. Then a stator-flux-oriented vector control strategy is employed to control the rotor-side current. Subsequently, a grid voltagevector-oriented control strategy is used to control the grid-side system of the grid-connected generator. Considering the nonlinearityand parameter uncertainty of the system, an active disturbance rejection controller with a sliding-mode-based extended-state observeris developed for the above-mentioned control strategies. Furthermore, the stability of the controller is tested and the performance of thecontroller is compared with the classical proportional-integral controller based on disturbance rejection, robustness and tracking capability in a highly non-linear wind speed variation scenario. Modelling, control and comparison are conducted in the MATLAB®/Simulink®environment. Finally, a real-time hardware set-up is presented using the dSPACE ds-1104 R&D processing board to validate the controlscheme. From the result of the experiments, it is seen that the proposed controller takes 10-15 control cycles to settle to its steady-statevalues, depending on the control loop, whereas the conventional proportional-integral controller takes 60-75 control cycles. As a result,the settling time for the proposed control scheme is shorter than that of the proportional-integral controller. 展开更多
关键词 doubly-fed induction generator variable-speed wind turbine vector control active disturbance rejection controller stability analysis
原文传递
Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault 被引量:4
15
作者 Botong Li Dingchuan Zheng +3 位作者 Bin Li Xinru Jiao Qiteng Hong Liang Ji 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第2期321-335,共15页
Given the“carbon neutralization and carbon peak”policy,enhancing the low voltage ride-through(LVRT)capability of wind farms has become a current demand to ensure the safe and stable operation of power systems in the... Given the“carbon neutralization and carbon peak”policy,enhancing the low voltage ride-through(LVRT)capability of wind farms has become a current demand to ensure the safe and stable operation of power systems in the context of a possible severe threat of large-scale disconnection caused by wind farms.Currently,research on the LVRT of wind farms mainly focuses on suppressing rotor current and providing reactive current support,while the impact of active current output on LVRT performance has not been thoroughly discussed.This paper studies and reveals the relation-ship between the limit of reactive current output and the depth of voltage drop during LVRT for doubly-fed induction generator(DFIG)based wind farms.Specifically,the reactive current output limit of the grid-side converter is inde-pendent of the depth of voltage drop,and its limit is the maximum current allowed by the converter,while the reac-tive current output limit of the DFIG stator is a linear function of the depth of voltage drop.An optimized scheme for allocating reactive current among the STATCOM,DFIG stator,and grid-side converter is proposed.The scheme maximizes the output of active current while satisfying the standard requirements for reactive current output.Com-pared to traditional schemes,the proposed LVRT optimization strategy can output more active power during the LVRT period,effectively suppressing the rate of rotor speed increase,and improving the LVRT performance and fault recov-ery capability of wind farms.Simulation results verify the effectiveness of the proposed scheme. 展开更多
关键词 doubly-fed induction generator(DFIG) Low voltage ride-through(LVRT) Transient characteristics Reactive current output capacity Maximum active power
原文传递
基于撬棒并联动态电阻的自适应双馈风力发电机低电压穿越 被引量:38
16
作者 张曼 姜惠兰 《电工技术学报》 EI CSCD 北大核心 2014年第2期271-278,共8页
当电网故障引起电压跌落时,为防止大装机容量风电场的风机脱网,双馈风力发电机(DFIG)多采用Crowbar电路来实现低电压穿越(LVRT)。传统Crowbar电路采用固定阻值的电阻,很难兼顾对转子电流和直流母线电压的抑制以及对Crowbar的投入工作时... 当电网故障引起电压跌落时,为防止大装机容量风电场的风机脱网,双馈风力发电机(DFIG)多采用Crowbar电路来实现低电压穿越(LVRT)。传统Crowbar电路采用固定阻值的电阻,很难兼顾对转子电流和直流母线电压的抑制以及对Crowbar的投入工作时间的控制。针对传统Crowbar的不足提出了一种基于Crowbar并联动态电阻的双馈风力发电机低电压穿越方案,制定了该方案的自适应控制策略以及其阻值的整定方法。仿真分析不同跌落深度下所提方案的LVRT特性,并与改变IGBT的导通脉宽的变电阻Crowbar方案进行了比较,结果表明带并联动态电阻Crowbar方案的LVRT效果较好,不仅兼顾了对转子过电流和直流母线过电压的抑制,而且在电压深度跌落时可缩短Crowbar的投入时间,有利于系统电压的恢复。 展开更多
关键词 撬棒 并联动态电阻(PDR) 自适应控制 低电压穿越 双馈风力发电机(DFIG) parallel dynamic resistor(PDR) low voltage ride-through (LVRT) doubly-fed induction generator(DFIG)
下载PDF
风电场内风电机组连锁脱网机理与低电压穿越能力研究 被引量:14
17
作者 向昌明 范立新 +2 位作者 蒋一泉 顾天畏 顾伟 《电力自动化设备》 EI CSCD 北大核心 2013年第12期91-97,共7页
在江苏地区各风电场相关参数及低电压穿越能力测试数据的基础上,在DIgSILENT中对基于双馈风电机组的大规模风电场进行建模,可详细描述风电场内各风机低电压穿越的动态特性。在不同的电压跌落场景下,对风电场内部各风电机组的不同故障反... 在江苏地区各风电场相关参数及低电压穿越能力测试数据的基础上,在DIgSILENT中对基于双馈风电机组的大规模风电场进行建模,可详细描述风电场内各风机低电压穿越的动态特性。在不同的电压跌落场景下,对风电场内部各风电机组的不同故障反应特性进行比较分析,确定整个风电场的低电压穿越能力并得出规律性结论。通过严重故障仿真得到风电场内部风机的脱网时序分布,分析了风机之间交互影响机理与连锁脱网的详细过程。最后,提出适当提高撬棒保护整定值、网侧变换器灵活运行和采用SVC等装置进行动态无功补偿可以提高风电场低电压穿越能力。 展开更多
关键词 风电场 建模 双馈机组 低电压穿越 撬棒保护 DIGSILENT
下载PDF
基于最优控制策略的双馈水轮发电机组稳定性分析 被引量:9
18
作者 李辉 杨顺昌 《水力发电学报》 EI CSCD 北大核心 2005年第1期83-87,共5页
为了分析可调速双馈水轮发电机组的静态稳定性 ,针对变速恒频双馈发电机的运行特点以及水轮机的刚性水击模型 ,本文推导了可调速双馈水轮发电机组的小扰动线性数学模型。以最优控制理论为基础 ,应用最小误差激励法比较了不同状态变量的... 为了分析可调速双馈水轮发电机组的静态稳定性 ,针对变速恒频双馈发电机的运行特点以及水轮机的刚性水击模型 ,本文推导了可调速双馈水轮发电机组的小扰动线性数学模型。以最优控制理论为基础 ,应用最小误差激励法比较了不同状态变量的线性反馈控制的系统稳定性和静、动态性能指标。分析结果表明 ,选择机组的有功功率、无功功率、转速和导叶开度的反馈控制具有较好的系统静态稳定性和控制效果。最后 ,以上述状态变量的反馈控制为实例 ,详细分析了系统参数变化对双馈水轮发电机组静态稳定性的影响。 展开更多
关键词 电机电工 双馈发电机 水轮发电机组 静稳定性 最优控制策略
下载PDF
双馈风电场送出线路重合闸时间计算方法 被引量:3
19
作者 徐岩 鲁振威 王慧 《华北电力大学学报(自然科学版)》 CAS 北大核心 2017年第5期10-17,共8页
由于投资成本等原因,现场存在一些双馈风电场送出线路没有安装线路电压互感器,或者电压互感器因断线等故障退出运行时,线路自动重合闸方式受限,一般设置为延时重合闸,重合闸时间往往根据经验整定,缺乏理论依据。电压越限是双馈风机和风... 由于投资成本等原因,现场存在一些双馈风电场送出线路没有安装线路电压互感器,或者电压互感器因断线等故障退出运行时,线路自动重合闸方式受限,一般设置为延时重合闸,重合闸时间往往根据经验整定,缺乏理论依据。电压越限是双馈风机和风电场内无功补偿设备脱网的重要原因,并且过电压会对设备造成很大伤害。首先理论分析了送出线路瞬时故障后双馈风机定子电压的变化过程,然后结合双馈风机保护模型提出了双馈风电场送出线路重合闸时间计算方法,最后在DIg SILENT/Power Factory中搭建双馈风电场并网仿真模型,通过不同故障条件下的仿真验证了理论分析的正确性,同时表明所提方法是有效的。 展开更多
关键词 重合闸时间 送出线路 风电场 双馈风电机组 定子电压
下载PDF
改进型PR控制器应用于双馈风力发电系统 被引量:4
20
作者 曾进辉 孙志峰 +1 位作者 雷敏 兰征 《电力电子技术》 CSCD 北大核心 2019年第2期87-90,共4页
此处提出将改进型比例谐振(PR)控制器应用于双馈感应风力发电(DFIG)系统电流环控制的并网控制策略,无需引入与电路参数有关的交叉耦合项且减小了坐标变换带来的控制复杂性,可实现对电流的稳态无静差追踪及单位功率因数控制,提高了系统... 此处提出将改进型比例谐振(PR)控制器应用于双馈感应风力发电(DFIG)系统电流环控制的并网控制策略,无需引入与电路参数有关的交叉耦合项且减小了坐标变换带来的控制复杂性,可实现对电流的稳态无静差追踪及单位功率因数控制,提高了系统的鲁棒性。最后将PR控制器数字化应用于11 kW DFIG实验平台,实验结果表明所提控制策略应用于DFIG系统具有优良的动态性能且能够有效抑制谐波。 展开更多
关键词 双馈感应风力发电 比例谐振 单位功率因数
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部