Bottomless electromagnetic cold crucible is a new apparatus for continuous melting and directional solidification;however,improving its power efficiency and optimizing the configuration are important for experiment an...Bottomless electromagnetic cold crucible is a new apparatus for continuous melting and directional solidification;however,improving its power efficiency and optimizing the configuration are important for experiment and production.In this study,a 3-D finite element (FE) method based on experimental verification was applied to calculate the magnetic flux density (Bz).The effects of the power parameters and the induction coil on the magnetic field distribution in the cold crucible were investigated.The results show that higher current intensity and lower frequency are beneficial to the increase of Bz at both the segment midpoint and the slit location.The induction coil with racetrack section can induce greater Bz,and a larger gap between the induction coil and the shield ring increases Bz.The mechanism for this effect is also discussed.展开更多
This paper describes a conceptual design study for the circuit configuration of the Error Field Correction Coil (EFCC) power supply (PS) to maximize the expected performance with reasonable cost in JT-60SA. The EF...This paper describes a conceptual design study for the circuit configuration of the Error Field Correction Coil (EFCC) power supply (PS) to maximize the expected performance with reasonable cost in JT-60SA. The EFCC consists of eighteen sector coils installed inside the vacuum vessel, six in the toroidal direction and three in the poloidal direction, each one rated for 30 kA-turn. As a result, star point connection is proposed for each group of six EFCC coils installed cyclically in the toroidal direction for decoupling with poloidal field coils. In addition~ a six phase inverter which is capable of controlling each phase current was chosen as PS topology to ensure higher flexibility of operation with reasonable cost.展开更多
The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying ...The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying a rather high current but also a large nuclear heating and irradiation owing to the plasma operation. All the severe operating conditions, including the structure stress intensity and the stability of the structure, largely limit the maximum allowable current density. But in order to contain a very high dense plasma, it is hoped that the fusion power plant system can operate with a much high maximum magnetic field BT ≥12 T-15 T in the center post. A new method is presented in this paper to improve the maximum magnetic field up to 17 T and to investigate the possibility of the normal conducting center post to be used in the future fusion tokamak power plant.展开更多
Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and e...Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic.展开更多
在无线电能传输(wireless power transfer,WPT)系统中,偏移是不可避免的,偏移会引起系统参数的变化从而影响系统的传输性能。基于S-S和P-S补偿拓扑,提出一种具有抗偏移特性的双耦合SP-S补偿的紧凑型WPT系统。该系统采用两个同轴布置、...在无线电能传输(wireless power transfer,WPT)系统中,偏移是不可避免的,偏移会引起系统参数的变化从而影响系统的传输性能。基于S-S和P-S补偿拓扑,提出一种具有抗偏移特性的双耦合SP-S补偿的紧凑型WPT系统。该系统采用两个同轴布置、相互解耦的圆角方形线圈作为能量的发射线圈,其与单一方形接收线圈均有耦合,提升了X方向和Y方向的抗偏移容忍度。通过谐振参数配置使接收线圈在偏移的过程中,一个线圈回路的输出增加,另一个线圈回路输出减少,从而使系统输出随接收线圈位置偏移波动平缓。提出方形解耦线圈结构参数的设计方法,并分析发射端并联补偿电容对输出抗偏移性能的影响。最后,搭建实验平台验证该方法的有效性与系统的抗偏移能力。展开更多
基金financially supported by the National Basic Research Program of China (Grant No.2011CB605504)
文摘Bottomless electromagnetic cold crucible is a new apparatus for continuous melting and directional solidification;however,improving its power efficiency and optimizing the configuration are important for experiment and production.In this study,a 3-D finite element (FE) method based on experimental verification was applied to calculate the magnetic flux density (Bz).The effects of the power parameters and the induction coil on the magnetic field distribution in the cold crucible were investigated.The results show that higher current intensity and lower frequency are beneficial to the increase of Bz at both the segment midpoint and the slit location.The induction coil with racetrack section can induce greater Bz,and a larger gap between the induction coil and the shield ring increases Bz.The mechanism for this effect is also discussed.
基金supported within the framework of the "Broader Approach Internationals Agreement"
文摘This paper describes a conceptual design study for the circuit configuration of the Error Field Correction Coil (EFCC) power supply (PS) to maximize the expected performance with reasonable cost in JT-60SA. The EFCC consists of eighteen sector coils installed inside the vacuum vessel, six in the toroidal direction and three in the poloidal direction, each one rated for 30 kA-turn. As a result, star point connection is proposed for each group of six EFCC coils installed cyclically in the toroidal direction for decoupling with poloidal field coils. In addition~ a six phase inverter which is capable of controlling each phase current was chosen as PS topology to ensure higher flexibility of operation with reasonable cost.
基金The project supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) Nuclear Researchers Exchange Program of Japan
文摘The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying a rather high current but also a large nuclear heating and irradiation owing to the plasma operation. All the severe operating conditions, including the structure stress intensity and the stability of the structure, largely limit the maximum allowable current density. But in order to contain a very high dense plasma, it is hoped that the fusion power plant system can operate with a much high maximum magnetic field BT ≥12 T-15 T in the center post. A new method is presented in this paper to improve the maximum magnetic field up to 17 T and to investigate the possibility of the normal conducting center post to be used in the future fusion tokamak power plant.
文摘Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic.
文摘在无线电能传输(wireless power transfer,WPT)系统中,偏移是不可避免的,偏移会引起系统参数的变化从而影响系统的传输性能。基于S-S和P-S补偿拓扑,提出一种具有抗偏移特性的双耦合SP-S补偿的紧凑型WPT系统。该系统采用两个同轴布置、相互解耦的圆角方形线圈作为能量的发射线圈,其与单一方形接收线圈均有耦合,提升了X方向和Y方向的抗偏移容忍度。通过谐振参数配置使接收线圈在偏移的过程中,一个线圈回路的输出增加,另一个线圈回路输出减少,从而使系统输出随接收线圈位置偏移波动平缓。提出方形解耦线圈结构参数的设计方法,并分析发射端并联补偿电容对输出抗偏移性能的影响。最后,搭建实验平台验证该方法的有效性与系统的抗偏移能力。