Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bon...Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bone;and 4) Osteotomy execution time. Materials and Methods: This article examines the heat produced by drills during osteotomy, focusing on the effect of the following factors: drilling technique;volume of autologous bone harvested;drilling time;implant primary stability;and the percentage of osseointegrated implants after primary healing. Discussion: The four factors mentioned above are analyzed based on the data obtained for sequential, biological, and One Drill milling techniques. Conclusions: 1) One Drill is the fastest technique for performing the osteotomy;2) All techniques stay within the biological temperature range of living bone, with the lowest increase in temperature achieved using One Drill with irrigation;3) The bone harvested showed no statistically significant differences between biological milling and the One Drill technique, both far superior to the sequential technique;and 4) There is no statistically significant difference in the number of osseointegrated implants among the three techniques analyzed.展开更多
Geothermal resources is one of the most practical and competitive new energy at present,and there is abundant geothermal resources in the new coastal region.The article get the three following conclusion through the g...Geothermal resources is one of the most practical and competitive new energy at present,and there is abundant geothermal resources in the new coastal region.The article get the three following conclusion through the geothermal geological condition by the drilling strata and the condition of the reducing test:stratigraphic division is done by the analysis of formation lithology and the drilling aging;the water yield is higher than 100m3/h,the flow temperature is 67℃--71℃;the average geothermal gradient of the overlying strata is 3.08℃--3.33℃/100 m.展开更多
文摘Background: Four factors determine the quality of an implantology kit: 1) Heat generated by the drills;2) Morphology of the osteotomy according to the diameter of the implant;3) Efficiency of collecting autologous bone;and 4) Osteotomy execution time. Materials and Methods: This article examines the heat produced by drills during osteotomy, focusing on the effect of the following factors: drilling technique;volume of autologous bone harvested;drilling time;implant primary stability;and the percentage of osseointegrated implants after primary healing. Discussion: The four factors mentioned above are analyzed based on the data obtained for sequential, biological, and One Drill milling techniques. Conclusions: 1) One Drill is the fastest technique for performing the osteotomy;2) All techniques stay within the biological temperature range of living bone, with the lowest increase in temperature achieved using One Drill with irrigation;3) The bone harvested showed no statistically significant differences between biological milling and the One Drill technique, both far superior to the sequential technique;and 4) There is no statistically significant difference in the number of osseointegrated implants among the three techniques analyzed.
文摘Geothermal resources is one of the most practical and competitive new energy at present,and there is abundant geothermal resources in the new coastal region.The article get the three following conclusion through the geothermal geological condition by the drilling strata and the condition of the reducing test:stratigraphic division is done by the analysis of formation lithology and the drilling aging;the water yield is higher than 100m3/h,the flow temperature is 67℃--71℃;the average geothermal gradient of the overlying strata is 3.08℃--3.33℃/100 m.