Based on the method of compound and additional conditions under the conditions of the equal temperature rise and the equal potential drop (P.D.) of resistance, the application of design software of dry-type air-core r...Based on the method of compound and additional conditions under the conditions of the equal temperature rise and the equal potential drop (P.D.) of resistance, the application of design software of dry-type air-core reactor is introduced in this thesis. The analytical methods of the inductance are also given. This approach is proved entirely feasible in theory through the simplification with Bartky transformation, and is able to quickly and accurately calculate reactor inductance. This paper presents the analytical methods of the loss of dry-type air-core reactor as well.展开更多
This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a f...This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a fault occurs far away from the measurement site, the measured impedance might not be directly proportional to the fault distance, and the protection domain of distance protection will be decreased. The detailed theory inferred and proven in this paper reveals that this phenomenon is widespread in EHV transmission lines. The results indicate that the protection domain error is greatly reduced by the application of the shunt reactor. Overall, simulation results show that the proposed method is effective for impedance relay, considering different characteristics, different lengths of lines, and compensation degrees.展开更多
The high frequency transient recovery voltage caused by usually switching operation of the circuit breakers, used on shunt reactor switching, have become a noticeable problem recently. For extension the service life t...The high frequency transient recovery voltage caused by usually switching operation of the circuit breakers, used on shunt reactor switching, have become a noticeable problem recently. For extension the service life time and normal operation of the circuit breakers, a well modified maintenance strategy is proposed. The field testing and experimental measurement showed the maintenance strategy proposed had been proved effectively and adopted in Taiwan Power Company.展开更多
文摘Based on the method of compound and additional conditions under the conditions of the equal temperature rise and the equal potential drop (P.D.) of resistance, the application of design software of dry-type air-core reactor is introduced in this thesis. The analytical methods of the inductance are also given. This approach is proved entirely feasible in theory through the simplification with Bartky transformation, and is able to quickly and accurately calculate reactor inductance. This paper presents the analytical methods of the loss of dry-type air-core reactor as well.
文摘This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a fault occurs far away from the measurement site, the measured impedance might not be directly proportional to the fault distance, and the protection domain of distance protection will be decreased. The detailed theory inferred and proven in this paper reveals that this phenomenon is widespread in EHV transmission lines. The results indicate that the protection domain error is greatly reduced by the application of the shunt reactor. Overall, simulation results show that the proposed method is effective for impedance relay, considering different characteristics, different lengths of lines, and compensation degrees.
文摘The high frequency transient recovery voltage caused by usually switching operation of the circuit breakers, used on shunt reactor switching, have become a noticeable problem recently. For extension the service life time and normal operation of the circuit breakers, a well modified maintenance strategy is proposed. The field testing and experimental measurement showed the maintenance strategy proposed had been proved effectively and adopted in Taiwan Power Company.