As the switching frequency in DC/DC converter increases, original ‘hard-switch’ working mode is not compatible. Another problem is the reliability, which is puzzled in single-ended forward, push-pull or bridge-like ...As the switching frequency in DC/DC converter increases, original ‘hard-switch’ working mode is not compatible. Another problem is the reliability, which is puzzled in single-ended forward, push-pull or bridge-like structures. In this paper, a new dual-ZCS (zero current switches) forward topology is proposed. The operating principle of soft-switch is analyzed, showing the relationship between voltage and current in time domain. Then how to calculate the key parameters of resonant network is . Finally, a prototype ZCS SMPS is implemented and tested. The results consisted with the analyzing results well, and illustrated the advantages of the proposed structure.展开更多
文摘As the switching frequency in DC/DC converter increases, original ‘hard-switch’ working mode is not compatible. Another problem is the reliability, which is puzzled in single-ended forward, push-pull or bridge-like structures. In this paper, a new dual-ZCS (zero current switches) forward topology is proposed. The operating principle of soft-switch is analyzed, showing the relationship between voltage and current in time domain. Then how to calculate the key parameters of resonant network is . Finally, a prototype ZCS SMPS is implemented and tested. The results consisted with the analyzing results well, and illustrated the advantages of the proposed structure.