This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design ...This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application.展开更多
In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection sho...In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.展开更多
In this paper, simulation and implementation way for practical control of Single Inverter Microgrid (SIMG) is presented. This system is equipped by solar system, wind energy conversion system (WECS), and microturbine ...In this paper, simulation and implementation way for practical control of Single Inverter Microgrid (SIMG) is presented. This system is equipped by solar system, wind energy conversion system (WECS), and microturbine system. Each DG’s has controlled independently. This is a kind of decentralize control because each DG’s has difference controller. Control of Microgrid (MG) during both grid tie and islanding modes is presented. Solar system and WECS are modeled based on santerno products. This system is compared with three inverter MGs with Centralize control strategy. Controlled signals show that SIMG is more reliable and economical. THD is improved and strategy is simplified for SIMG.展开更多
文摘This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application.
文摘In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink.
文摘In this paper, simulation and implementation way for practical control of Single Inverter Microgrid (SIMG) is presented. This system is equipped by solar system, wind energy conversion system (WECS), and microturbine system. Each DG’s has controlled independently. This is a kind of decentralize control because each DG’s has difference controller. Control of Microgrid (MG) during both grid tie and islanding modes is presented. Solar system and WECS are modeled based on santerno products. This system is compared with three inverter MGs with Centralize control strategy. Controlled signals show that SIMG is more reliable and economical. THD is improved and strategy is simplified for SIMG.