期刊文献+
共找到140篇文章
< 1 2 7 >
每页显示 20 50 100
Noise properties of multi-combination information in x-ray grating-based phase-contrast imaging
1
作者 Wali Faiz 李冀Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province,College of Physics and Optoelectronic Engineering,Shenzhen University +4 位作者 高昆 吴朝 雷耀虎 黄建衡 朱佩平 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第1期329-335,共7页
Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction meth... Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction method to perform practical applications.In this work,noise properties of multi-combination information of newly established information extraction method,so-called angular signal radiography method,are investigated to provide guidelines for targeted and specific applications.The results show that how multi-combination of images can be used in targeted practical applications to obtain a high-quality image in terms of signal-to-noise ratio.Our conclusions can also hold true for upcoming targeted practical applications such as biomedical imaging,non-destructive imaging,and materials science. 展开更多
关键词 grating-based phase-contrast imaging signal-to-noise ratio REFRACTION SCATTERING
下载PDF
自主研发高分辨盆腔专用线圈在3.0 T磁共振设备成像价值的评估
2
作者 王晓 郑福玲 +8 位作者 陆晓平 李娟 张鹏 刘梦超 金川 张宏宇 王天娇 王沄 薛华丹 《磁共振成像》 CAS CSCD 北大核心 2024年第1期158-162,178,共6页
目的探讨自主研发的16通道高分辨盆腔专用线圈(16C)在3.0 T盆腔MRI中的应用价值。材料和方法前瞻性招募35例行盆腔MRI的患者,分别用16C线圈和32通道的体部线圈(32C)采集相同的轴位和矢状位T2WI序列。比较相同序列图像中第三骶椎、子宫... 目的探讨自主研发的16通道高分辨盆腔专用线圈(16C)在3.0 T盆腔MRI中的应用价值。材料和方法前瞻性招募35例行盆腔MRI的患者,分别用16C线圈和32通道的体部线圈(32C)采集相同的轴位和矢状位T2WI序列。比较相同序列图像中第三骶椎、子宫肌层、前列腺外周带、直肠壁和闭孔内肌的信噪比(signal to noise ratio,SNR)及对比噪声比(contrast to noise ratio,CNR)。由两位诊断医师各自对两组图像质量和直肠轴位图像直肠壁分层结构的显示度进行主观评分。结果两组线圈相同序列的T2WI矢状位第三骶椎、子宫肌层、前列腺外周带和轴位闭孔内肌的SNR差异具有统计学意义(P<0.05),矢状位第三骶椎、子宫肌层和轴位直肠壁对肌肉的CNR差异具有统计学意义(P<0.05),16C组高于32C组。两组线圈相同序列的T2WI图像质量主观评价差异具有统计学意义(P<0.05),16C组图像质量更优。在轴位T2WI直肠壁分层结构的显示度评价方面两组图像差异具有统计学意义(P<0.05),16C组更优。结论16C线圈在3.0 T磁共振设备上成像质量更好,更有利于盆腔疾病的诊断。 展开更多
关键词 磁共振成像 线圈 信噪比 对比噪声比 图像质量
下载PDF
基于图像形态学的焊缝区域提取与对比度提升技术
3
作者 刘欢 刘骁佳 +3 位作者 赵耀邦 王宁 罗志强 危荃 《中国材料进展》 CAS CSCD 北大核心 2024年第2期175-180,共6页
铝板焊接后可使用X射线进行焊缝内部缺陷检测,由于X射线成像存在噪声多、对比度低、焊缝区域边缘模糊、焊缝区域与背景区域灰度分布较为相似等问题,使用传统边缘检测方法效果欠佳。提出了一种自动提取焊缝区域并提高其对比度的方法,通... 铝板焊接后可使用X射线进行焊缝内部缺陷检测,由于X射线成像存在噪声多、对比度低、焊缝区域边缘模糊、焊缝区域与背景区域灰度分布较为相似等问题,使用传统边缘检测方法效果欠佳。提出了一种自动提取焊缝区域并提高其对比度的方法,通过去噪处理、边缘检测、形态学操作等步骤,最终确定焊缝区域位置,并对焊缝区域内像素值进行线性变换,提高了焊缝区域的对比度。实验结果表明,该方法针对大批量的铝板X射线图片,都能够自动提高焊缝区域的对比度,具有良好的鲁棒性和准确性。 展开更多
关键词 图像处理 X射线 焊缝区域 梯度 对比度
下载PDF
内耳钆增强磁共振3D CUBE FLAIR序列PPI及HYDROPS图像在诊断内淋巴积水中的价值
4
作者 王子坤 冯晶晶 +5 位作者 吴杰 叶玉芳 陈英敏 时媛 吴晶 孙利强 《磁共振成像》 CAS CSCD 北大核心 2024年第3期151-157,176,共8页
目的 探讨经静脉注射钆对比剂行内耳增强磁共振三维快速液体衰减反转恢复序列(three-dimensional fluid attenuated inversion recovery with CUBE,3D CUBE FLAIR)阳性内淋巴影像(positive perilymph image,PPI)及HYDROPS (HYbriD of re... 目的 探讨经静脉注射钆对比剂行内耳增强磁共振三维快速液体衰减反转恢复序列(three-dimensional fluid attenuated inversion recovery with CUBE,3D CUBE FLAIR)阳性内淋巴影像(positive perilymph image,PPI)及HYDROPS (HYbriD of reversed image of positive endolymph signal and native image of positive perilymph signal)图像在内淋巴积水(endolymphatic hydrops,EH)中的诊断价值。材料与方法 回顾性分析患侧EH、对侧无EH患者资料及MRI图像22例。应用Image J软件在所获图像上勾画感兴趣区,测量同一图像上患侧及健侧的耳蜗底周与同侧小脑白质区信号强度比(signal intensity ratio,SIR)、同一侧前庭外淋巴与内淋巴间隙SIR;对PPI及HYDROPS图像上患侧耳蜗积水数量及前庭积水边界清晰程度评分。评估两种图像对患侧血-迷路屏障(blood-labyrinth barrier,BLB)通透性改变的显示情况、同侧前庭在两种图像上的成像效果、评估两种图像对耳蜗EH敏感性及前庭EH边界的显示情况。结果 PPI图像中患侧及健侧的耳蜗底周与同侧小脑白质区SIR之间的差异具有统计学意义(P<0.001);HYDROPS图像中患侧及健侧耳蜗底周与同侧小脑白质区SIR之间的差异具有统计学意义(P<0.001)。PPI图像及HYDROPS图像上的患侧前庭外淋巴与内淋巴间隙SIR之间的差异具有统计学意义(P<0.001);PPI图像及HYDROPS图像上的健侧前庭外淋巴与内淋巴SIR间隙之间的差异具有统计学意义(P<0.001)。PPI图像及HYDROPS图像诊断耳蜗EH的敏感性之间的差异具有统计学意义(P=0.030)。PPI图像及HYDROPS图像患侧前庭内淋巴间隙边界清晰程度评分之间的差异具有统计学意义(P<0.001)。结论 内耳钆增强磁共振3D CUBE FLAIR序列PPI及HYDROPS图像综合应用,有利于评估患侧BLB通透性、积水部位以及前庭EH边界的显示。 展开更多
关键词 内淋巴积水 耳蜗 前庭 血-迷路屏障 通透性 钆对比剂 信号强度比 磁共振成像
下载PDF
三维多回波聚合梯度回波序列在腰骶丛成像中的初步应用
5
作者 李运运 彭传勇 +2 位作者 吴宗山 徐启兰 陈琪 《分子影像学杂志》 2024年第4期403-406,共4页
目的 探讨3D多回波聚合梯度回波序列(3D GEMEC)在腰骶丛神经成像中的应用价值。方法 回顾性分析2022年8~9月六安市人民医院以腰腿疼为主诉的32例住院患者的影像学资料,男15例,女17例,年龄28~78(60.1±15.8)岁。在不同1.5T平台上分... 目的 探讨3D多回波聚合梯度回波序列(3D GEMEC)在腰骶丛神经成像中的应用价值。方法 回顾性分析2022年8~9月六安市人民医院以腰腿疼为主诉的32例住院患者的影像学资料,男15例,女17例,年龄28~78(60.1±15.8)岁。在不同1.5T平台上分别完成腰骶丛3D GEMEC序列和三维T2加权快速梯度回波(3D T2 FFE)序列,比较两种序列腰骶丛神经的信噪比、对比噪声比和主观显示效果。结果 3D GEMEC序列腰骶丛神经的信噪比、对比噪声比以及主观显示效果与3D T2 FFE序列的差异均无统计学意义(P=0.250、0.146、0.083)。结论 3D GEMEC序列可以清晰地显示腰骶丛神经的解剖结构并抑制背景信号,在腰骶丛神经病变的诊断方面具有一定的临床应用前景。 展开更多
关键词 腰骶丛神经 磁共振成像技术 3D多回波聚合梯度回波序列 信噪比 对比噪声比
下载PDF
磁共振AIR-魔毯线圈在胸椎结核扫描中的应用价值
6
作者 徐冬 王玉群 +1 位作者 孙萌萌 侯代伦 《医学影像学杂志》 2024年第6期118-120,共3页
目的探讨联合应用AIR-魔毯线圈磁共振成像(MRI)对胸椎结核扫描图像信噪比(signal to noise ratio,SNR)、对比噪声比(contrast to noise ratio,CNR)和脂肪抑制成像效果的价值。方法选取我院80例经手术病理证实为胸椎结核患者,按1:1随机... 目的探讨联合应用AIR-魔毯线圈磁共振成像(MRI)对胸椎结核扫描图像信噪比(signal to noise ratio,SNR)、对比噪声比(contrast to noise ratio,CNR)和脂肪抑制成像效果的价值。方法选取我院80例经手术病理证实为胸椎结核患者,按1:1随机分为两组,应用常规线圈(脊柱相控阵线圈,头颈联合线圈)、常规线圈联合AIR魔毯线圈对两组患者分别进行扫描。扫描序列包括胸椎矢状位T_(2)WI,T_(1)WI,T_(2)FLEX,进一步测量、比较SNR,CNR及脂肪抑制效果,分析MRI多序列诊断胸腰椎结核的准确率、特异度和灵敏度。结果常规线圈联合AIR-魔毯线圈扫描组,胸椎矢状位图像的SNR、CNR及压脂效果优于常规线圈组。结论联合应用AIR-魔毯线圈的图像SNR、CNR得到提高,脂肪抑制效果稳定良好。 展开更多
关键词 胸椎结核 磁共振成像 AIR-魔毯线圈 信噪比 对比噪声比
下载PDF
不同对比剂流速对肝癌患者CT增强扫描图像的影响
7
作者 卢铮 《医疗装备》 2024年第12期13-15,19,共4页
目的 探讨不同对比剂流速对肝癌患者CT增强扫描图像的影响。方法 选取2019年1月至2022年12月于医院收治的156例肝癌患者为研究对象,根据随机数字表法分为试验组与对照组,每组78例。所有患者均行CT增强扫描,碘海醇注射液剂量为100 ml,试... 目的 探讨不同对比剂流速对肝癌患者CT增强扫描图像的影响。方法 选取2019年1月至2022年12月于医院收治的156例肝癌患者为研究对象,根据随机数字表法分为试验组与对照组,每组78例。所有患者均行CT增强扫描,碘海醇注射液剂量为100 ml,试验组对比剂流速为2.0~2.5 ml/s,对照组对比剂流速为3.5~4.0 ml/s,记录两组不良反应发生情况、影像学特征、辐射剂量与图像质量。结果 试验组不良反应发生率低于对照组(P <0.05);所有患者图像均能显示4~6级肝血管分支;两组图像质量评分比较,差异无统计学意义(P>0.05)。试验组图像信噪比和对比噪声比低于对照组(P<0.05);两组剂量长度乘积与有效剂量比较,差异无统计学意义(P>0.05)。两组动脉期、门脉期、平衡期的病灶检出率比较,差异无统计学意义(P>0.05)。结论 CT增强扫描中对比剂流速降低不会影响图像质量及病灶检出率,且不增加辐射剂量,但可降低不良反应发生率、图像信噪比和对比噪声比。 展开更多
关键词 CT增强扫描 对比剂流速 图像质量 不良反应 辐射剂量
下载PDF
Enhancement of microvessel in laser speckle image using gaussian kernel template
8
作者 Yameng Zhang Yuemei Zhao +2 位作者 Weitao Li Zhiyu Qian Lidong Xing 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2019年第2期54-63,共10页
Laser speckle contrast imaging(LSCI)is an optical imaging method,which can monitor microvascularflow variation directly without addition of any ectogenous dye.All the existing laser speckle contrast analysis(LASCA)met... Laser speckle contrast imaging(LSCI)is an optical imaging method,which can monitor microvascularflow variation directly without addition of any ectogenous dye.All the existing laser speckle contrast analysis(LASCA)methods are a combination of spatial and temporal statistics.In this study,we have proposed a new method,Gaussian kernel laser speckle contrast analysis(gLASCA),which processes the raw images primarily with the Gaussian kernel operator along the spatial direction of bloodflow.We explored the properties of gLASCA in the simulation and animal cerebral ischemia perfusion model.Compared with the other existing speckle processing methods based on spatial,temporal,spatial-temporal or anisotropic linear structure;the present gLASCA method has a high spatial-temporal resolution to respond the change of velocity especially in microvasculature.Besides,the gLASCA method obtains approximately 10.2%and 7.1%higher contrast-to-noise ratio(CNR)over the anisotropic linear method(aLASCA)in the simulation and experiment models.For these advantages,gLASCA could be a better method for local microvascular laser speckle imaging in terms of cerebral ischemia reperfusion,spreading depression and brain injury diseases. 展开更多
关键词 Brain vasculature bloodflow contrast imaging linear operator contrast-to-noise ratio
下载PDF
光梭径向采集技术在屏气配合欠佳状态下肝脏动态增强扫描中的应用价值 被引量:3
9
作者 邓和平 张宇 +6 位作者 杨学刚 卢予婕 王丹 董晓蕾 何雅坤 陈佳 王闽 《放射学实践》 CSCD 北大核心 2023年第5期631-635,共5页
目的:探讨光梭径向采集(uCSR)技术在屏气配合欠佳患者进行肝脏动态增强扫描中的应用价值。方法:搜集35例无法配合屏气检查的患者作为研究对象,在自由呼吸状态下采用uCSR序列进行肝脏动态增强扫描,该序列扫描结束后立即进行3D-VIBE序列... 目的:探讨光梭径向采集(uCSR)技术在屏气配合欠佳患者进行肝脏动态增强扫描中的应用价值。方法:搜集35例无法配合屏气检查的患者作为研究对象,在自由呼吸状态下采用uCSR序列进行肝脏动态增强扫描,该序列扫描结束后立即进行3D-VIBE序列扫描。由两位高年资医师采用5分法分别对uCSR重建的各期相准确性、uCSR序列延迟期与3D-VIBE序列延迟期总体图像质量及呼吸运动伪影抑制效果进行评分。由两位高年资技师对uCSR序列延迟期和3D-VIBE序列延迟期图像进行信噪比(SNR)及对比噪声比(CNR)值测量。结果:两位医师对uCSR重建的各期相准确性评分均高于4.0分(分别为4.86±0.355、4.83±0.382),表明uCSR序列能获得准确的肝脏动态增强扫描期相。对3D-VIBE序列和uCSR序列扫描的延迟期图像进行总体质量评分,结果显示uCSR图像明显优于3D-VIBE(Z=-5.241,P=0.000)。对3D-VIBE序列与uCSR序列延迟期图像的呼吸运动伪影抑制效果进行评分,结果显示uCSR图像更优(Z=-5.279,P=0.000)。对两组图像质量进行客观评价,结果显示3D-VIBE图像的SNR稍优于uCSR(Z=-2.359,P=0.018),CNR差异无统计学意义(Z=-1.753,P=0.08)。结论:对于屏气配合欠佳的患者进行肝脏动态增强扫描时,uCSR序列可以获得良好的图像,具有一定临床应用价值。 展开更多
关键词 磁共振成像 动态增强 信噪比 对比噪声比 压缩感知
下载PDF
深度学习重建法提高磁共振高分辨海马冠状位图像质量的比较研究 被引量:2
10
作者 杨晶 李琼阁 +3 位作者 吴涛 齐志刚 赵澄 卢洁 《磁共振成像》 CAS CSCD 北大核心 2023年第5期21-24,30,共5页
目的 探讨深度学习重建(deep learning reconstruction,DLR)在提高高分辨率T2液体衰减反转恢复(fluid-attenuated inversion-recovery,FLAIR)序列海马冠状位MRI图像质量中的作用。材料与方法前瞻性纳入36例神经系统疾病患者,进行高分辨... 目的 探讨深度学习重建(deep learning reconstruction,DLR)在提高高分辨率T2液体衰减反转恢复(fluid-attenuated inversion-recovery,FLAIR)序列海马冠状位MRI图像质量中的作用。材料与方法前瞻性纳入36例神经系统疾病患者,进行高分辨率海马T2-FLAIR冠状位扫描,并对图像进行DLR,对原始重建(origin reconstruction,OR)图像和DLR图像的噪声、伪影、海马结构辨识度、病灶可识别度和诊断接受度进行主观评价,测量并计算两组图像的信噪比、对比噪声比和双侧海马信号强度差值。结果DLR的T2-FLAIR海马冠状位图像噪声、海马结构辨识度、病灶可识别度和诊断接受评分均高于OR T2-FLAIR海马冠状位(P<0.001),伪影评分差异无统计学意义(Z=-1.730;P=0.084);DLR T2-FLAIR海马冠状位图像的信噪比和对比噪声比均明显高于OR T2-FLAIR海马冠状位(t=-13.061;P<0.001和t=-16.224;P<0.001);两组图像双侧海马信号差值差异无统计学意义(t=-0.290;P=0.977)。结论 DLR不延长扫描时间就可以明显提高高分辨T2-FLAIR海马冠状位图像的海马结构和小病灶的清晰度,降低噪声,为临床诊断提供高质量图像。 展开更多
关键词 海马 深度学习重建法 癫痫 信噪比 对比噪声比 磁共振成像
下载PDF
Application of Dual-Energy Computed Tomography for Breast Cancer Diagnosis
11
作者 Yukiko Okamura Nobuko Yoshizawa +1 位作者 Masaru Yamaguchi Ikuo Kashiwakura 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第4期288-297,共11页
The present study aimed to investigate the possibility of using dual-energy computed tomography (CT) before therapy to discriminate between normal breast tissue and tumor tissue in patients with breast cancer, without... The present study aimed to investigate the possibility of using dual-energy computed tomography (CT) before therapy to discriminate between normal breast tissue and tumor tissue in patients with breast cancer, without the need to use a contrast medium. The following patient data were extracted by interview and from the hospital’s radiology information system: height, weight, age, menstrual cycle, CT images of normal tissue and tumors with or without contrast medium, and the histopathological diagnosis of the aspiration biopsy. The median age of the 43 participants was 56 years (range, 30 - 80 years). The CT values were evaluated using a clinical analytical program based on the three-material decomposition technique. Breast cancer was classified into ductal carcinoma in situ, invasive ductal carcinoma, invasive lobular carcinoma, fibromatosis-like metaplastic carcinoma, and apocrine carcinoma. In all conditions, regardless of contrast medium, the CT values of tumor tissues were higher than those of normal breast tissue, indicating the effectiveness of dual-energy CT (DE-CT) in the diagnosis of breast cancer. By contrast, DE-CT showed limited potential for distinguishing ductal carcinoma in situ from invasive ductal carcinoma. There have only been a few reports regarding CT examination of breast cancer, and it is expected this study encourage the development of DE-CT imaging to improve tumor detection in patients with breast cancer. 展开更多
关键词 Breast Cancer dual-energy CT CT Value contrast Medium Oncological imaging Ductal Carcinoma in Situ Invasive Ductal Carcinoma
下载PDF
磁共振成像三种增强序列对骨和软组织病变增强效果的比较研究 被引量:1
12
作者 方昕 韦超 +3 位作者 李信响 曹锋 陈东 董江宁 《中国医学装备》 2023年第2期24-29,共6页
目的:比较研究磁共振成像(MRI)系统的T1快速自旋回波(T1FSE)序列、T1三点法非对称回波水脂分离成像(T1IDEAL)序列及T1容积加速肝脏采集(T1LAVA-Flex)序列3种增强序列成像在骨和软组织病变中的增强效能,以提高四肢软组织MRI增强的质量和... 目的:比较研究磁共振成像(MRI)系统的T1快速自旋回波(T1FSE)序列、T1三点法非对称回波水脂分离成像(T1IDEAL)序列及T1容积加速肝脏采集(T1LAVA-Flex)序列3种增强序列成像在骨和软组织病变中的增强效能,以提高四肢软组织MRI增强的质量和效率。方法:选取在医院就诊的31例行骨盆及下肢软组织MRI检查的患者,按照随机数表法将每例患者在平扫的基础上同时予以T_(1) FSE、T_(1) IDEA和LAVA-Flex增强序列检查的结果分别纳入T_(1) FSE组、T_(1) IDEA组和LAVA-Flex组,比较3组图像的信噪比(SNR)、对比噪声比(CNR)、背景信号的标准差(SD)、病灶边缘的清晰度及伪影评分。采用单因素方差分析方法和LSD两两比较的方法比较3组序列的增强效能,并进行图像清晰度及伪影评分比较。结果:3组中的31例患者T1FSE、T1IDEAL和T1LAVA-Flex序列增强图像的SNR、CNR和SD比较,T1IDEAL组SNR、CNR和SD最佳,其余依次为T1FSE组、T1LAVA-Flex组,3组SNR、CNR和SD的比较差异有统计学意义(F=59.759,F=5.362,F=109.33;P<0.05)。T1FSE组和T1IDEAL组图像显示病灶边缘清晰度均优于T1LAVA-Flex组,差异有统计学意义(χ^(2)=7.939,χ^(2)=5.429;P<0.05);但伪影T1IDEAL组和T1LAVA-Flex组高于T1FSE组,3组比较差异有统计学意义(χ^(2)=5.905,P<0.05)。结论:T1IDEAL增强序列成像在骨与软组织病变中具有最高的SNR、CNR和清晰度,以及较少的伪影,可作为骨及软组织病变增强扫描的首选序列,T1 FSE可以做为基本的增强序列,T_(1) LAVA-Flex增强序列可降低增强扫描的时间。 展开更多
关键词 骨与软组织 磁共振成像(MRI) 增强扫描 信噪比(SNR) 对比噪声比(CNR)
下载PDF
光梭径向采集与T1-quick3D序列肝动脉期图像质量的对比研究
13
作者 邓和平 张宇 +3 位作者 卢予婕 董晓蕾 王闽 杨学刚 《影像诊断与介入放射学》 2023年第3期211-215,共5页
目的探讨光梭径向采集技术(uCSR)对于肝脏动脉期图像质量的影响。方法回顾性分析142例行肝脏动态增强扫描者的动脉期图像,其中79例采用uCSR序列进行动态增强扫描,63例采用T1三维容积内插值法屏气检查(T1-quick3D)序列进行动态增强扫描,... 目的探讨光梭径向采集技术(uCSR)对于肝脏动脉期图像质量的影响。方法回顾性分析142例行肝脏动态增强扫描者的动脉期图像,其中79例采用uCSR序列进行动态增强扫描,63例采用T1三维容积内插值法屏气检查(T1-quick3D)序列进行动态增强扫描,由两名医师采用5分法对两组动脉期图像进行评分,评分内容包括动脉期期相准确性、动脉期图像总体质量及图像伪影情况,由两名技师对动脉期图像进行测值并计算信号噪声比(SNR)及对比噪声比(CNR)。结果两名医师及两名技师对图像质量的各项评价的一致性较好或很好。动脉期期相准确性评分结果显示uCSR组[5(5,5)]优于T1-quick3D组[5(4,5)](P=0.001);总体图像质量评分结果显示uCSR组[4(4,5)]与T1-quick3D组[4(4,5)]一致,两组具有统计学差异(P=0.047);图像伪影评分结果显示uCSR组[4(4,5)]图像伪影较T1-quick3D组[5(4,5)]明显(P=0.003);T1-quick3D组的SNR值(285.40±46.430)及CNR值(107.64±34.900)均高于uCSR组的SNR值(205.41±48.147)及CNR值(95.98±34.542)。结论uCSR的图像质量(SNR、CNR及图像伪影)劣于T1-quick3D序列,但uCSR能获得更准确的动脉期图像。 展开更多
关键词 磁共振成像 动态增强 动脉期 信号噪声比 对比噪声比
下载PDF
基于粗糙集的微小缺陷图像对比度增强算法
14
作者 唐爱平 杨丽 《控制工程》 CSCD 北大核心 2023年第5期881-885,共5页
设计了一种微小缺陷图像对比度增强算法。采用粗糙集理论将图像划分为不同类别,同一类别中像素间为不可分辨关系。并依据图像灰度值和噪声属性进一步将图像划分为子图,在子图中得到图像的明暗区域。对图像不同区域进行直方图均衡变换和... 设计了一种微小缺陷图像对比度增强算法。采用粗糙集理论将图像划分为不同类别,同一类别中像素间为不可分辨关系。并依据图像灰度值和噪声属性进一步将图像划分为子图,在子图中得到图像的明暗区域。对图像不同区域进行直方图均衡变换和直方图指数变换处理,处理后即可增强图像的对比度。仿真实验表明,处理后可突出显示图像中的微小细节,图像不同区域之间的划分效果更加明显,可以有效提升图像的对比度和视觉效果。 展开更多
关键词 粗糙集理论 图像对比度 不可分辨关系 信噪比 最大类间方差法
下载PDF
基于深度学习重建技术改善前列腺T2WI图像质量的研究 被引量:4
15
作者 可赞 李亮 +5 位作者 宋鑫洋 文之 高宇凡 刘薇音 权光南 查云飞 《磁共振成像》 CAS CSCD 北大核心 2023年第5期41-47,共7页
目的 探讨基于深度学习重建(deep learning-based reconstruction, DLR)技术对前列腺T2WI图像质量及诊断置信度的影响。材料与方法 回顾性分析78例行前列腺磁共振检查患者的影像资料,扫描序列包括传统T2WI(conventional T2WI, T2WI_C)... 目的 探讨基于深度学习重建(deep learning-based reconstruction, DLR)技术对前列腺T2WI图像质量及诊断置信度的影响。材料与方法 回顾性分析78例行前列腺磁共振检查患者的影像资料,扫描序列包括传统T2WI(conventional T2WI, T2WI_C)及基于DLR技术的T2WI(T2WI_(DL)),二者扫描参数及时间相同。对所有患者的T2WI_C及T2WI_(DL)图像进行主观评价、客观评价及诊断置信度评价。主观评价及诊断置信度评价由两名具有不同影像诊断经验(3年、7年)的医师(阅片者1、阅片者2)依据Likert Scale评分法进行双盲评价(5分:优,1分:极差),并采用Wilcoxon秩和检验及Kappa统计法评估两位阅片者间评分的差异性及一致性;T2WI图像质量评价指标包括:前列腺包膜清晰度、病灶对比度及边缘锐利度、解剖细节的显示、盆腔肌肉及骨骼的清晰度及整体图像质量;T2WI诊断置信度评价指标包括:病灶位置及形态识别、病灶良恶性的初步判断。分别记录两位阅片者浏览每一组图像及作出初步诊断的用时,采用配对t检验进行统计学分析。客观评价包括测量T2WI_C及T2WI_(DL)图像前列腺病灶的信噪比(signal-to-noise ratio, SNR)及对比噪声比(contrast-to-noise ratio, CNR),使用配对t检验和Mann-Whitney U检验进行统计学分析。结果 本研究78例患者年龄(67.1±9.9)岁。基于主观评分标准,两名阅片者T2WI_C图像的总评分分别为(3.4±0.7)、(3.0±0.8)分,T2WI_(DL)图像的总评分分别为(4.6±0.6)、(4.3±0.7)分;两名阅片者对T2WI_(DL)图像评分一致性为0.6~0.8,在解剖细节及整体图像质量方面,两名阅片者间评分差异有统计学意义(P<0.05)。诊断置信度评价方面,两名阅片者总评分和用时分别为T2WI_C图像:(3.8±0.4)分、(3.7±0.5)分和(36.6±12.6)s、(25.0±5.7) s;T2WI_(DL)图像:(4.8±0.3)分、(4.8±0.4)分和(28.6±11.0) s、(20.6±5.4) s;差异均具有统计学意义(P<0.01)。基于客观评价,T2WI_(DL)图像的SNR及CNR均高于T2WI_C图像,差异具有统计学意义(P<0.05);其中良、恶性病灶T2WI_C和T2WI_(DL)的SNR分别为(12.4±2.4)、(10.1±1.8)和(28.7±8.1)、(27.7±5.4),差异均有统计学意义(P<0.01);良、恶性病灶有无DL的CNR差异均无统计学意义(P>0.05)。结论 T2WI_(DL)图像主观评分高、病灶对比度明显、SNR及CNR均高于传统T2WI_C图像,且诊断医师对T2WI_(DL)图像诊断信心更足、诊断用时更少。故相同扫描时间内,基于DLR技术有助于提高前列腺T2WI图像质量,为临床诊疗提供了更为精准的影像学依据。 展开更多
关键词 前列腺 前列腺癌 深度学习 磁共振成像 图像质量 信噪比 对比噪声比
下载PDF
深度学习重建在改善磁共振神经黑色素图像质量中的价值研究 被引量:2
16
作者 于阳 赵澄 +2 位作者 齐志刚 吴涛 卢洁 《磁共振成像》 CAS CSCD 北大核心 2023年第5期11-15,共5页
目的 探讨深度学习重建(deep learning reconstruction, DL Recon)在改善神经黑色素MRI序列图像质量中的价值。材料与方法 前瞻性纳入2022年5月10日至2022年5月31日首都医科大学宣武医院正常志愿者30例,并对每位志愿者进行DL Recon 2D... 目的 探讨深度学习重建(deep learning reconstruction, DL Recon)在改善神经黑色素MRI序列图像质量中的价值。材料与方法 前瞻性纳入2022年5月10日至2022年5月31日首都医科大学宣武医院正常志愿者30例,并对每位志愿者进行DL Recon 2D快速自旋回波(fast spin echo, FSE)T1WI序列及临床传统2D FSE T1WI扫描,并保存DL Recon 2D FSE T1WI原始图像(即未施加DL Recon的图像),扫描结束后对3组图像进行主客观评价,主观评价采用“五分法”分别对图像均匀度、锐利度、伪影、图像整体质量进行评分,结果采用四分位间距M (P25, P75)进行统计描述;客观评价从中脑黑质(substantia nigra, SN)、蓝斑(locus ceruleus, LC)的信噪比(signal to noise ratio, SNR)以及上述区域与周边组织的对比噪声比(contrast noise ratio, CNR)进行评价,采用方差分析对结果进行统计学分析。结果 DL Recon 2D FSE T1WI图像、原始图像及临床传统2D FSE T1WI图像均匀度的主观评分分别为4(4,5)、4(4,5)、4(4,5)(Z=1.31,P>0.05);锐利度评分为4(4,5)、3(3,4)、3(3,4)(Z=2.57,P<0.001);伪影评分为3(3,4)、4(4,5)、4(4,5)(Z=3.43,P<0.001);图像整体质量评分为4(4,5),3(2,3),3(3,4)(Z=2.77,P<0.001)。在对3组图像的主观评分中,图像均匀度之间的差异无统计学意义,锐利度、伪影和图像整体质量评分差异具有统计学意义(P<0.05);DL Recon 2D FSE T1WI图像、原始图像及临床传统2D FSE T1WI图像客观评价结果为:SNRSN 250.38±9.02、66.19±7.32、110.91±10.10,SNRLC 220.41±12.02、 50.26±5.89、 90.38±11.70;CNRSN25.30±3.42、 7.87±1.12、 8.01±1.38;CNRLC30.17±2.23、 10.54±2.08、11.11±1.89。DL Recon 2D FSE T1W1组在显示SN和LC方面的SNR、CNR值均高于原始图像和传统2D FSE T1WI组,且差异有统计学意义(P<0.001)。结论 DL Recon 2D FSE T1WI序列通过采用原始K空间数据深度学习降噪算法,在保证空间分辨率的情况下,改善原始序列图像SNR及CNR,并且可大幅度缩短扫描时间,有望成为神经黑色素MRI的常规检查手段。 展开更多
关键词 黑质 蓝斑 信噪比 对比噪声比 深度学习重建 磁共振成像
下载PDF
压缩感知技术对乳腺T1高分辨率各向同性容积激发序列的成像影响及序列优化 被引量:1
17
作者 宁宁 梁泓冰 +8 位作者 张丽娜 张楠 田佳禾 宋清伟 吴祺 王卓 李远飞 赵思奇 杨洁 《磁共振成像》 CAS CSCD 北大核心 2023年第10期116-121,131,共7页
目的 探讨压缩感知(compressed sense,CS)技术对乳腺T1高分辨率各向同性容积激发序列(enhanced-T1 high resolution isotropic volume excitation,e-THRIVE)图像质量及扫描时间的影响,并优化乳腺e-THRIVE序列。材料与方法 前瞻性纳入行... 目的 探讨压缩感知(compressed sense,CS)技术对乳腺T1高分辨率各向同性容积激发序列(enhanced-T1 high resolution isotropic volume excitation,e-THRIVE)图像质量及扫描时间的影响,并优化乳腺e-THRIVE序列。材料与方法 前瞻性纳入行乳腺MRI检查的43名乳腺患者(时间-信号强度曲线均为平台型),采用3.0 T MRI设备在e-THRIVE序列的基础上,采用不同加速因子(acceleration factor,AF)[敏感度编码(sensitivity encoding,SENSE)技术AF=4,CS AF=4,CS AF=5,CS AF=6,CS AF=7]对患者行乳腺MRI增强扫描。本研究在注射对比剂后的e-THRIVE序列上进行。由两位观察者对图像进行主观评价和客观测量。计算图像信噪比(signal to noise ratio,SNR)和对比噪声比(contrast to noise ratio,CNR)以及相对对比度(relative contrast,RC)。采用Friedman检验对客观评分及主观评价进行组间比较,若差异有统计学意义(P<0.05),进行后续多重比较。结果 两位观察者客观评分及主观评分一致性良好,不同AF图像间SNR腺体、CNR腺体、SNR病灶、CNR病灶及主观评分差异有统计学意义(P<0.05);不同AF图像间RC腺体-病灶、RC病灶-肌肉和RC腺体-肌肉差异无统计学意义(P>0.05)。两两比较结果表明SENSE AF=4、CS AF=4和CS AF=5图像的SNR腺体、CNR腺体、SNR病灶、CNR病灶及主观评分均大于CS AF=6和CS AF=7(P<0.05)。结论 综合考虑扫描时间和图像质量,乳腺e-THRIVE序列推荐选择AF=5的CS序列,较常规扫描并行采集缩短26.7%的扫描时间。 展开更多
关键词 乳腺 乳腺癌 乳腺纤维腺瘤 动态增强 压缩感知 信噪比 对比噪声比 磁共振成像
下载PDF
基于暗通道技术的核电用不锈钢环焊缝DR图像质量优化 被引量:1
18
作者 朱秀森 高鸿波 +4 位作者 胡茂春 吕成澍 张士晶 王战 胡坦能 《无损检测》 CAS 2023年第4期27-32,86,共7页
为提高曝光不足的小径管环焊缝缺陷数字射线成像(DR)检测识别度,以完成核电站压力容器的安全性监测,将导向滤波和暗通道去雾理论相结合,对低剂量下的小径管环焊缝DR图像进行图像增强,通过客观评价指标对图像质量进行评价,并与自适应直... 为提高曝光不足的小径管环焊缝缺陷数字射线成像(DR)检测识别度,以完成核电站压力容器的安全性监测,将导向滤波和暗通道去雾理论相结合,对低剂量下的小径管环焊缝DR图像进行图像增强,通过客观评价指标对图像质量进行评价,并与自适应直方图均衡化(AHE)和限制对比度自适应直方图均衡化(CLAHE)图像增强方法进行对比。结果表明,暗通道图像增强技术对图像质量的改善效果更好,图像对比度噪声比提高了31.5%,信噪比提高了约1.5倍,缺陷轮廓更清晰。 展开更多
关键词 数字射线 图像增强 暗通道 对比度噪声比 信噪比
下载PDF
快速智能磁共振技术在颈椎磁共振扫描中的应用价值
19
作者 徐敏 吴瑜 +3 位作者 刘键 王荣品 徐睿 曾宪春 《磁共振成像》 CAS CSCD 北大核心 2023年第10期111-115,共5页
目的 探讨快速智能磁共振(intelligent quick magnetic resonance,IQMR)技术在颈椎MRI中的临床应用价值。材料与方法 本研究回顾性分析临床疑颈椎病变患者临床资料50例,纳入颈椎T2WI常规图像、IQMR原始图像及IQMR重建图像。采用ANOVA检... 目的 探讨快速智能磁共振(intelligent quick magnetic resonance,IQMR)技术在颈椎MRI中的临床应用价值。材料与方法 本研究回顾性分析临床疑颈椎病变患者临床资料50例,纳入颈椎T2WI常规图像、IQMR原始图像及IQMR重建图像。采用ANOVA检验比较三组图像的客观评分[感兴趣区域信号强度(signal strength,SI)、平均背景噪声(standard deviation,SD)、信噪比(signal-to-noise ratio,SNR)、对比噪声比(contrast-to-noise ratio,CNR)]之间的差异,采用多样本秩和(Kruskal-Wallis H)检验评价主观评分之间的差异性,并比较三组图像的病灶检出情况与扫描时间。结果 IQMR颈椎矢状位T2WI序列扫描平均时间约1 min 17 s,与常规MRI相比时间缩短约57%;与原始图像相比,经过IQMR重建所得图像的SD背景下降21%,SNR提升28%,CNR提升30%;与常规图像相比,经过IQMR重建所得图像SD下降43%,SNR提升50%、CNR提升68%;三组图像之间SI脊髓差异无统计学意义;三组图像之间SI脑脊液差异具有统计学意义(P<0.05),且常规图像SI脑脊液低于IQMR原始图像及IQMR重建图像。结 论IQMR技术在颈椎MRI中能降低SD、提高SNR及CNR,从而提高图像质量,因此IQMR技术能够在保证图像质量的情况下,缩短扫描时间、提高颈椎MRI的扫描效率。 展开更多
关键词 颈椎 信噪比 对比噪声比 快速智能磁共振技术 磁共振成像
下载PDF
深度学习重建技术在膀胱癌MRI临床应用中的可行性研究 被引量:3
20
作者 张馨心 王绎忱 +4 位作者 王思聪 李敏 胡满仓 陈雁 赵心明 《磁共振成像》 CAS CSCD 北大核心 2023年第5期36-40,共5页
目的 探讨深度学习重建(deep learning reconstruction, DLR)技术对膀胱癌MRI图像质量及扫描时间的影响。材料与方法 前瞻性纳入病理诊断为膀胱癌的初诊患者分别行膀胱MRI常规快速自旋回波(fast-spin echo, FSE)-T2WI和DLR快速FSE-T2WI... 目的 探讨深度学习重建(deep learning reconstruction, DLR)技术对膀胱癌MRI图像质量及扫描时间的影响。材料与方法 前瞻性纳入病理诊断为膀胱癌的初诊患者分别行膀胱MRI常规快速自旋回波(fast-spin echo, FSE)-T2WI和DLR快速FSE-T2WI扫描,并保存未使用DLR的原始快速FSE-T2WI。由2名放射科医师分别对三组T2WI(常规FSE-T2WI、快速FSE-T2WI和DLR快速FSE-T2WI)的整体图像质量和图像伪影进行图像质量主观评价(5分标准)。由1名放射科医师测量病变的信噪比(signal-to-noise ratio, SNR)和病变与髂腰肌的对比噪声比(contrast-to-noise ratio, CNR)。对正态分布和非正态分布的数据分别进行单因素方差分析和Friedman检验,比较分析三组T2WI的主观评分和客观指标的差异。采用Weighted-Kappa检验比较组间及组内主观评分一致性。结果 本研究共纳入32例膀胱癌患者,年龄39~93(65±11)岁。缩短扫描时间的快速FSE-T2WI的整体图像质量、伪影评分、SNR(63.2±25.5 vs. 94.7±40.8,P<0.05)、CNR(40.0±19.0vs. 59.6±29.8,P<0.05)均显著低于常规FSE-T2WI;应用DLR显著提高快速FSE-T2WI的整体图像质量、伪影评分、SNR(256.7±102.9 vs. 63.2±25.5,P<0.05)、CNR(168.0±77.3 vs. 40.0±19.0,P<0.05);DLR快速FSE-T2WI的整体图像质量评分及SNR(256.7±102.9 vs. 94.7±40.8,P<0.05)和CNR(168.0±77.3 vs. 59.6±29.8,P<0.05)显著高于常规FSE-T2WI。结论 DLR可以缩短图像扫描时间,并在定量和定性方面提高图像质量,使膀胱癌患者更快完成MRI检查成为可能。 展开更多
关键词 膀胱癌 深度学习重建 磁共振成像 信噪比 对比噪声比
下载PDF
上一页 1 2 7 下一页 到第