期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Fabric Wetting and Wicking Measurement Based on Dynamic Image Acquisition and Processing 被引量:1
1
作者 张瑞云 潘宁 姜福青 《Journal of Donghua University(English Edition)》 EI CAS 2010年第4期544-550,共7页
After a brief review of existing methods for fabric wetting and wicking measurement,a new numerical approach based on dynamic image acquisition and analysis was proposed to study the liquid wetting and wicking propert... After a brief review of existing methods for fabric wetting and wicking measurement,a new numerical approach based on dynamic image acquisition and analysis was proposed to study the liquid wetting and wicking properties of woven fabrics.A measuring system was first developed to record on-site the images of liquid ascending in fabrics for a certain period of time.The hardware and software platforms and the experimental methods were described,and the image processing and analysis as well as other related algorithms were discussed in detail.The liquid front curves and rising rates in wetting and wicking were eventually obtained towards different fabrics.From liquid wicking curves,relationship between liquid ascending height and liquid ascending time agrees well with the Washburn theory.The data comparison between the numerical measurement and the traditional test proves the reliability of the numerical results. 展开更多
关键词 wetting and wicking image processing woven fabric image dynamic acquisition
下载PDF
Performance analysis of fast GPS signal acquisition based on PMF and Window FFT 被引量:4
2
作者 李传军 杨树兴 季镇 《Journal of Beijing Institute of Technology》 EI CAS 2012年第3期291-297,共7页
Combining the advantages of partial matched filter(PMF) and fast Fourier transform(FFT),an improved fast acquisition method for GPS C/A code is proposed.According to PMF-FFT acquisition architecture,the greater th... Combining the advantages of partial matched filter(PMF) and fast Fourier transform(FFT),an improved fast acquisition method for GPS C/A code is proposed.According to PMF-FFT acquisition architecture,the greater the number of PMF will bring out the more slowly amplitude decreasing of the amplitude-frequency response,the smaller scale of the corresponding PMF,and the larger computation of the FFT.In order to compensate the frequency spectrum attenuation caused by spectrum leakage and fence effect,adding window function to PMF-FFT is presented.Through comparing the influences to the acquisition performance based on rectangular,Hamming,Blackman and Rife-Vincent(Ⅲ) window functions,an improved Rife-Vincent Ⅲ windowing algorithm is recommended for the fast acquisition based on PMF-FFT. 展开更多
关键词 fast acquisition PMF FFT window function high dynamic receiver
下载PDF
Perioperative Evaluation of Cerebral Blood Flow Using ^123I-labeled N-isopropyl-p-iodoamphetamine Single-Photon Emission Computed Tomography without Blood Sampling in Patients Who Underwent Carotid Artery Stenting
3
作者 Naoki Matsumoto Rei Enatsu +5 位作者 Yasuzumi Matsui Hiroyuki Ikeda Norikazu Yamana Masashi Oda Masaaki Saiki Osamu Narumi 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第13期1616-1618,共3页
The evaluation of regional cerebral vascular reserve (rCVR) with single-photon emission computed tomography (SPECT) is useful for predicting cerebral hyperperfusion following carotid artery stenting (CAS) and ca... The evaluation of regional cerebral vascular reserve (rCVR) with single-photon emission computed tomography (SPECT) is useful for predicting cerebral hyperperfusion following carotid artery stenting (CAS) and carotidendarterectomy (CEA). 展开更多
关键词 Carotid Artery Stenosis Carotid Artery Stenting N-isopropyl-p-iodoamphetamine-Rest and True Acetazolamide Images Estimated Method Using dynamic acquisition Single-Photon Emission Computed Tomography
原文传递
Numerical and experimental research on different inlet configurations of high speed centrifugal compressor 被引量:9
4
作者 LI Du YANG Ce +2 位作者 ZHOU Mi ZHU ZhiFu WANG Hang 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第1期174-181,共8页
Three different inlet configurations,including a original straight pipe and two bend pipes with different axial length,for a high speed low mass flow centrifugal compressor were modeled with whole blade passages and s... Three different inlet configurations,including a original straight pipe and two bend pipes with different axial length,for a high speed low mass flow centrifugal compressor were modeled with whole blade passages and simulated unsteadily by 3D viscous Navier-Stokes equations.The performance disparities of compressor stage were tested and verified by experiments in which dynamic pressure data acquisition of internal flow field was performed.As the result shows,the choke point decreases to lower mass flow rate due to the distortion caused by bend-pipe inlet and is aggravated as the rotation speed increases.The distortion effect spreads circumferentially in impeller and makes the flow structure varied.The longer axial distance bent inlet leads to larger radial distortion and heavy blockage at mid-span under large mass flow mainly causes compressor choke margin nar-rowed.Bend pipe distortion brings an impact up to diffuser on unsteady pressure pulsation caused by blades sweep and the impact appears more powerful when it is closer to volute tongue. 展开更多
关键词 centrifugal compressor inlet distortion numerical simulation dynamic data acquisition
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部