期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Clinical and functional comparison of dynamic hip screws and intramedullary nails for treating proximal femur metastases in older individuals 被引量:2
1
作者 Hua Gao Xiaodong Bai +5 位作者 Wentao Chen Yadong Li Liang Zhao Changgui Liu Zhenyu Liu Baojun Wang 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2020年第3期395-402,共8页
Objective:To compare the outcomes of dynamic hip screws(DHS)and intramedullary nailing(IMN)in the treatment of extra-capsular metastatic carcinoma of the proximal femur.Methods:A retrospective case analysis method was... Objective:To compare the outcomes of dynamic hip screws(DHS)and intramedullary nailing(IMN)in the treatment of extra-capsular metastatic carcinoma of the proximal femur.Methods:A retrospective case analysis method was used to examine data of patients with proximal metastatic cancer of the femur who were treated with internal fixation in Department of Orthopaedics,Beijing Friendship Hospital,from January 2007 to December 2018.Blood loss,postoperative pain,functional score,length of stay,and survival rates were compared,and postoperative complications were assessed.Results:Complete follow-up data were available for 33 patients.The mean follow-up period was 12.2±3.6(range:9-32)months and the average age was 72.3±4.7(range:59-83)years old.There were 20 females and 13 males.Twenty-three patients had undergone IMN and 10 DHS,according to bone defects and the patient’s overall condition.The median survival time was 10 months in the IMN group and 11 months in the DHS group.Duration of surgery(t=-7.366,P<0.001)and length of hospital stay(t=-3.509,P<0.001)differed significantly between the two groups.There was one case of breakage of internal fixation in the IMN group.Conclusions:There was no significant difference between DHS and IMN in terms of surgical efficacy.IMN and DHS were different in terms of surgical time and hospital stay.However,due to the limited number of cases in this study,multi-factor analysis has not been performed and needs to be further verified in future analysis.When developing a surgical plan,it is recommended to consider the patient’s condition and the surgeon’s experience. 展开更多
关键词 Proximal femur bone metastatic cancer dynamic hip screw(DHS) intramedullary nail(IMN) bone cements
下载PDF
Watson-Jones Anatomical Approach for Open Reduction and Internal Fixation of Proximal Femoral Fractures without Image Intensifier in a Low-Resource Setting
2
作者 Loïc Fonkoue Gaspary Fodjeu +6 位作者 Kennedy Olivier Muluem Olivier Ngongang Theophile Nana Marie Ange Ngo Yamben DésiréAkaba Urich Tambekou Daniel Eone Handy 《Open Journal of Orthopedics》 2024年第4期173-186,共14页
Introduction: Standard procedures for surgical fixation of proximal femoral fractures (PFF) require an image intensifier which in developing countries remains a luxury. We hypothesized that, with a well-codified techn... Introduction: Standard procedures for surgical fixation of proximal femoral fractures (PFF) require an image intensifier which in developing countries remains a luxury. We hypothesized that, with a well-codified technique, the Watson Jones approach (WJA) without image intensifier nor traction table, can allow open reduction and internal fixation (ORIF) of PFF using Dynamic hip screw (DHS), with satisfactory outcome. Patients and methods: Forty one consecutive patients (mean age 59.5 ± 21.6 years, 61% males) who were followed in a Teaching Hospital for PFF treated by ORIF using the WJA and DHS from January 2016 to December 2020 were reassessed. The outcome measures were the quality of the reduction, the positioning of the implants, the tip-apex distance (TAD), the rate and delay of consolidation, the functional results using Postel Merle d’Aubigné (PMA) score, the rate of surgical site infection (SSI) and the overall mortality. Logistic regression was used to determine factors associated with mechanical failure. Results: The mean follow-up period was 33.8 ± 15.0 months. Fracture reduction was good in 31 (75.6%) cases and acceptable in 8(19.5%) cases. Implant position was fair to good in 37 (90.2%) patients. The mean TAD was 26.1 ± 3.9 mm. Three patients developed SSI. Consolidation was achieved in 38 (92.6%) patients. The functional results were good to excellent in 80.5% of patients. The overall mortality rate was 7.3%. There were an association between mechanical failure and osteoporosis (p = 0.04), fracture reduction (p = 0.003), and TAD (p = 0.025). In multivariate logistic regression, no independent factors were predictive of mechanical failure. Conclusion: This study shows that ORIF using DHS for PFF via the Watson-Jones approach without an image intensifier can give satisfactory anatomical and functional outcomes in low-resource settings. It provides and validates a reliable and reproducible technique that deserves to be diffused to surgeons in austere areas over the world. 展开更多
关键词 Proximal Femoral Fracture Watson-Jones Approach dynamic hip Screw Low Resource Setting
下载PDF
Comparison of extramedullary and intramedullary devices for treatment of subtrochanteric femoral fractures at tertiary level center 被引量:2
3
作者 Sanjay Yadav Shivendra Sinha Edwin Luther Naresh Chander Arora Manish Prasad Rohit Varma 《Chinese Journal of Traumatology》 CAS CSCD 2014年第3期141-145,共5页
Objective: The treatment of subtrochanteric fractures is challenging and treatment modalities and implants are constantly evolving. This study attempts to revisit and compare extramedullary vs. intramedullary devices... Objective: The treatment of subtrochanteric fractures is challenging and treatment modalities and implants are constantly evolving. This study attempts to revisit and compare extramedullary vs. intramedullary devices in relatively young population. Methods: Thirty patients with subtrochanteric fractures were enrolled and treated with extramedullary or intramedullary devices and follow-up continued one year for clinico-radiological assessment. Results: The mean age of patients was 37,53 years. Most were males between 21-40 years. The dominant mode of injury was traffic accidents (66%). Fractures were classified according to Russell-Taylor classification. Forty percent were Russell-Taylor type IA, 37% type IB and 23% type IIA. Average time to surgery was 3.6 days from the time of admission to hospital. Mean duration of surgery was 45 minutes for intramedullary device (group A) and 105 minutes for extramedullary device (group B). Average blood loss was 100 ml in group A and 200 ml in group B. Mean duration of radiation exposure was 130 seconds and 140 seconds for groups A and B, while average duration of hospital stay was 12 days and 16 days respectively. Excellent results were seen in 47% of cases in group A and 33% of cases in group B. Conclusion: Intramedullary device is a reliable implant for subtrochanteric fractures. It has high rates of union with minimal soft-tissue damage. Intramedullary fixation has biological and biomechanical advantages, but surgery is technically demanding. Gradual learning and patience is needed to make this method truly rewarding. 展开更多
关键词 Subtrochanteric fractures INTRAMEDULLARY dynamic hip screw
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部