The magnitude of dynamic load produced by high-speed trains depends on many factors,of which train speed is the most critical one.However,it is quite difficult to determine the effect of train speed on dynamic load us...The magnitude of dynamic load produced by high-speed trains depends on many factors,of which train speed is the most critical one.However,it is quite difficult to determine the effect of train speed on dynamic load using the theoretical methods due to the complexity of the interaction between vehicle and track-subgrade.Thus large-scale model test has gradually become an important approach for studying dynamic responses of ballastless track-subgrade of high-speed railway.In this study,a full-scale model of ballastless track-subgrade was constructed in accordance with the design and construction standards for Shanghai-Nanjing intercity high-speed railway line firstly.Then,the dynamic strain of slab and the dynamic earth pressure of subgrade were measured by conducting single wheel axle excitation test.In addition,the relationship between the dynamic load magnification factor(DLF) and the train speed was obtained.Finally,the DLF of track-subgrade under different train speeds was proposed,similar to that given by German Railway Standard.展开更多
为研究多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)抑制桥梁单阶涡振的性能,建立桥梁结构-MTMD系统竖弯涡振广义单自由度动力方程,以某大跨度悬索桥为背景进行MTMD减振控制效果和参数优化分析。采用数值方法求解动力方程,获...为研究多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)抑制桥梁单阶涡振的性能,建立桥梁结构-MTMD系统竖弯涡振广义单自由度动力方程,以某大跨度悬索桥为背景进行MTMD减振控制效果和参数优化分析。采用数值方法求解动力方程,获得系统在简谐涡激力下达到稳态谐振时结构的动力放大系数和MTMD对结构的附加模态阻尼比,并与单一频率调谐质量阻尼器(Single Tuned Mass Damper,STMD)的减振控制效果进行对比,然后以附加模态阻尼比为目标对MTMD进行参数优化。结果表明:MTMD比最优参数STMD拥有更宽的控制频带和更好的减振效果,经优化后的MTMD减振性能优于最优参数STMD。实际应用MTMD时,应选择较大广义质量、5~7种频率规格,并根据二者找到无量纲频率范围和各TMD阻尼比的惟一最优取值。展开更多
A newnumerical method based on vector form intrinsic finite element(VFIFE) is proposed to simulate the integral lifting process of steel structures. First, in order to verify the validity of the VFIFE method, taking...A newnumerical method based on vector form intrinsic finite element(VFIFE) is proposed to simulate the integral lifting process of steel structures. First, in order to verify the validity of the VFIFE method, taking the steel gallery between the integrated building and the attached building of Nanjing M obile Communication Buildings for example, the static analysis was carried out and the corresponding results were compared with the results achieved by the traditional finite element method. Then, according to the characteristics of dynamic construction of steel structure integral lifting, the tension cable element was employed to simulate the behavior of dynamic construction. The VFIFE method avoids the iterative solution of the stiffness matrix and the singularity problems. Therefore, it is simple to simulate the complete process of steel structure lifting construction.Finally, by using the VFIFE, the displacement and internal force time history curves of the steel structures under different lifting speeds are obtained. The results show that the lifting speed has influence on the lifting force, the internal force, and the displacement of the structure. In the case of normal lifting speed, the dynamic magnification factor of 1. 5 is safe and reasonable for practical application.展开更多
基金the National Natural Science Foundation of China(51225804,U1234204,51222803,51178418)for the financial supports
文摘The magnitude of dynamic load produced by high-speed trains depends on many factors,of which train speed is the most critical one.However,it is quite difficult to determine the effect of train speed on dynamic load using the theoretical methods due to the complexity of the interaction between vehicle and track-subgrade.Thus large-scale model test has gradually become an important approach for studying dynamic responses of ballastless track-subgrade of high-speed railway.In this study,a full-scale model of ballastless track-subgrade was constructed in accordance with the design and construction standards for Shanghai-Nanjing intercity high-speed railway line firstly.Then,the dynamic strain of slab and the dynamic earth pressure of subgrade were measured by conducting single wheel axle excitation test.In addition,the relationship between the dynamic load magnification factor(DLF) and the train speed was obtained.Finally,the DLF of track-subgrade under different train speeds was proposed,similar to that given by German Railway Standard.
文摘为研究多重调谐质量阻尼器(Multiple Tuned Mass Damper,MTMD)抑制桥梁单阶涡振的性能,建立桥梁结构-MTMD系统竖弯涡振广义单自由度动力方程,以某大跨度悬索桥为背景进行MTMD减振控制效果和参数优化分析。采用数值方法求解动力方程,获得系统在简谐涡激力下达到稳态谐振时结构的动力放大系数和MTMD对结构的附加模态阻尼比,并与单一频率调谐质量阻尼器(Single Tuned Mass Damper,STMD)的减振控制效果进行对比,然后以附加模态阻尼比为目标对MTMD进行参数优化。结果表明:MTMD比最优参数STMD拥有更宽的控制频带和更好的减振效果,经优化后的MTMD减振性能优于最优参数STMD。实际应用MTMD时,应选择较大广义质量、5~7种频率规格,并根据二者找到无量纲频率范围和各TMD阻尼比的惟一最优取值。
基金The National Natural Science Foundation of China(No.51308105)
文摘A newnumerical method based on vector form intrinsic finite element(VFIFE) is proposed to simulate the integral lifting process of steel structures. First, in order to verify the validity of the VFIFE method, taking the steel gallery between the integrated building and the attached building of Nanjing M obile Communication Buildings for example, the static analysis was carried out and the corresponding results were compared with the results achieved by the traditional finite element method. Then, according to the characteristics of dynamic construction of steel structure integral lifting, the tension cable element was employed to simulate the behavior of dynamic construction. The VFIFE method avoids the iterative solution of the stiffness matrix and the singularity problems. Therefore, it is simple to simulate the complete process of steel structure lifting construction.Finally, by using the VFIFE, the displacement and internal force time history curves of the steel structures under different lifting speeds are obtained. The results show that the lifting speed has influence on the lifting force, the internal force, and the displacement of the structure. In the case of normal lifting speed, the dynamic magnification factor of 1. 5 is safe and reasonable for practical application.