An adaptive dwell scheduling algorithm for phased array radar(PAR)is proposed in this paper.The concept of online dynamic template is introduced,based on which a general pulse interleaving technique for PAR is put for...An adaptive dwell scheduling algorithm for phased array radar(PAR)is proposed in this paper.The concept of online dynamic template is introduced,based on which a general pulse interleaving technique for PAR is put forward.The pulse interleaving condition of the novel pulse interleaving is more intuitive and general.The traditional adaptive dwell scheduling algorithm combined with the general novel pulse interleaving technique results in the online adaptive dwell scheduling based on dynamic template for PAR is given.The proposed algorithm is suitable for radar tasks with multiple pulse repetition intervals(PRIs),which can be utilized in the actual radar system.For the purpose of further improving the scheduling efficiency,an efficient version is proposed.Simulation results demonstrate the effectiveness of the proposed algorithm and the efficient one.The proposed efficient algorithm can improve the time utilization ratio(TUR)by 9%,the hit value ratio(HVR)by 3.5%,and reduce the task drop ratio(TDR)by 6%in comparison with existing dwell scheduling algorithms considering pulse interleaving in PAR and the proposed efficient one.展开更多
In this paper,dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates.The el...In this paper,dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates.The electrode prepared using a large applied current density showed an increased internal electroactive area and a significantly improved electrochemical performance.The analytical utility of the prepared dendritic Bi film electrodes for the determination of Pb(Ⅱ)and Cd(Ⅱ)in the range of 5–50 μg·L^(-1)were presented in combination with square wave stripping voltammetry in model solution.Compared with non-porous Bi film electrode,the dendritic Bi film electrode exhibited higher sensitivity and lower detection limit.The prepared Bi film electrode with dendritic structure was also successfully applied to real water sample analysis.展开更多
基金This work was supported by the National Natural Science Froundation of China(61032010).
文摘An adaptive dwell scheduling algorithm for phased array radar(PAR)is proposed in this paper.The concept of online dynamic template is introduced,based on which a general pulse interleaving technique for PAR is put forward.The pulse interleaving condition of the novel pulse interleaving is more intuitive and general.The traditional adaptive dwell scheduling algorithm combined with the general novel pulse interleaving technique results in the online adaptive dwell scheduling based on dynamic template for PAR is given.The proposed algorithm is suitable for radar tasks with multiple pulse repetition intervals(PRIs),which can be utilized in the actual radar system.For the purpose of further improving the scheduling efficiency,an efficient version is proposed.Simulation results demonstrate the effectiveness of the proposed algorithm and the efficient one.The proposed efficient algorithm can improve the time utilization ratio(TUR)by 9%,the hit value ratio(HVR)by 3.5%,and reduce the task drop ratio(TDR)by 6%in comparison with existing dwell scheduling algorithms considering pulse interleaving in PAR and the proposed efficient one.
基金Supported by the National Natural Science Foundation of China(51472073,51201058)
文摘In this paper,dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates.The electrode prepared using a large applied current density showed an increased internal electroactive area and a significantly improved electrochemical performance.The analytical utility of the prepared dendritic Bi film electrodes for the determination of Pb(Ⅱ)and Cd(Ⅱ)in the range of 5–50 μg·L^(-1)were presented in combination with square wave stripping voltammetry in model solution.Compared with non-porous Bi film electrode,the dendritic Bi film electrode exhibited higher sensitivity and lower detection limit.The prepared Bi film electrode with dendritic structure was also successfully applied to real water sample analysis.